Text version

REVISION

SHEET

SHEET REVISION RECORD

NEXT ASSY USED ON

APPLICATION

B

DWG NO.CAGE CODESIZE

SHEETSCALEDATE

APPROVED

REVIEWED

CHECKED

DRAWN

MATERIAL:

FRACTIONS DECIMALS ANGLES

TOLERANCES ON:

DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED:

PARTS LIST

NOTEDESCRIPTION

NOMENCLATURE OR

IDENTIFYING NO.

PART NO. OR

REQD

QTY

NO.

FIND

APPROVEDDATEDESCRIPTIONLTR

0NDM7

LETTERKENNY ARMY DEPOT

CHAMBERSBURG, PA. 17201

REV

REVISIONS

VIP

PANEL, VACUUM INSULATED, 14X13,

MOBILE INTEGRATED REMAINS

COLLECTION SYSTEM

891-11002

LEAD-FP-5126 -SAFETY

CATHY MARTIN

10 SEP 2018 1 : 8 1 OF 1

MIRCS-

C. MARTIN10 SEP 18RELEASED FOR PRODUCTION-

X.X 0.06

± X.XX 0.03

X.XXX 0.015

± 2°± 1/32

NOTES:

1. VACUUM INSULATED PANEL (VIP) THICKNESS SHALL BE 0.650"

+/-0.0625"

2. THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.020

BTU-INCH/FT2-HR-F PER ASTM C518

3. PANEL PERFORMANCE DEGRADATION SHALL NOT EXCEED 2.8%

PER YEAR

4. VIP SHALL BE RATED FOR TEMPERATURE EXPOSURE OF 200

DEGREES F MINIMUM.

14.000 +/-0.125

13.000 +/-0.125

DISTRIBUTION STATEMENT A

THIS DOCUMENT IS APPROVED FOR PUBLIC RELEASE: DISTRIBUTION IS UNLIMITED