This modification amends a solicitation for an oil pump test stand. The Army seeks one test stand to meet minimum requirements for the Anniston Army Depot, including installation, training, and manuals. The stand must not exceed dimensions of 84 inches in width, 108 inches in depth, and 132 inches in height, though an additional 24 inches of width is allowed to accommodate electrical panels and computer interfaces. The modification provides additional details on available chilled water specifications, the configurable test sequencer functionality, and clarifies that no further questions will be answered at this time.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
See page tw o.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 29-Mar-2023
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W911KF23Q0017
X 9B. DATED (SEE ITEM 11)
27-Feb-2023
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
29-Mar-2023
CODE
ACC-ANAD
ANNISTON ARMY DEPOT
7 FRANKFORD AVENUE, BLDG 35
ANNISTON AL 36201-4199
W911KF 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W911KF23Q0017
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
AMENDMENT 3 NOTES
1. The purpose of this modification is to answer Industry Questions for W911KF-23-Q-0017; Oil Pump Test Stand:
2. The SOW states the test stand's dimensions cannot exceed 84" in width x 108" in depth x 132" in height. These dimensions seem to include only the main test stand and does not include the space required for the electrical panels/computer/operator interface. Will there be additional space available to accommodate the electrical panels/computer/operator interface?
-We are ok adding 24 inches in width to the machine,but would like to keep original dimension from SOW if possible.
3. The existing test stand has two (2) heat exchangers which are cooled by "facility chilled water"... can you provide the specifications of the available "facility chilled water" (flow, pressure, temp, etc)? How many gallons per minute of chilled water is available? How many gallons does the current test stand consume?
-Plan for water at 70 degrees Fahrenheit at 35 gallons per minute
4. Please provide additional detail on the functionality and configurable parameters of the sequencer cited in the SOW?
- The test sequencer is part of the test software. It allows the use and reuse of existing sequences, preprogrammed functions, defining of inputs and output unique to each occurrence of the function in the test sequence, and the logic required to determine when to begin and end execution of any step in the sequence. The purpose is to allow the modification of test procedures (sequences) for existing units under test (UUT) and create new tests for future UUTs without knowledge of the underlying programming language (i.e. LabVIEW, C#, etc.). The sequencer needs to provide a way to create and modify sequences. Typically, each sequence is stored in a file. This file is created and edited using a text editor or test software specific GUI integrated into the test software or both.
Here is an example that may or may not resemble the delivered test stand. An oil pump test stand might be delivered with a main sequences for each type and configuration of pumps tested.
Some of the preprogrammed functions in these sequences might be Operator Prompt, Set Oil Temperature, Set Pump Speed, Set Scavenge Pressure, Set Main Pressure, Set Oil Pressure, Capture Data Set, etc.
Test stand functions that apply regardless of the UUT under test should be set, controlled, and monitored outside of any test sequence. Some of these functions may include the default oil temperature, absolute limits such as limits on motor acceleration and speed and oil temperature, operation of automated guarding, submersion of pump into oil, etc, updating of gauges and status indicators.
A sequencer will be used during automatic testing only. During manual testing, the operator will provide control and sequencing that would otherwise be performed by the sequencer during automatic testing.
5. No further questions will be answered at this time.
W911KF23Q0017
SUMMARY OF CHANGES
(End of Summary of Changes)