Panel Schedule

BRANCH VA Load Load VA BRANCH NO POLES BKR A B C Type Type A B C BKR POLES NO.

1 1 20 1137 L E 9150 125 3 2

3 1 20 527 L E 9150 - - 4

5 1 20 806 L E 9150 - - 6

7 1 20 1130 L E 681 20 3 8

9 1 20 907 L E 681 - - 10

11 1 20 54 L E 681 - - 12

13 1 20 605 L E 681 20 3 14

15 1 20 - E 681 - - 16

17 1 20 - E 681 - - 18

19 1 20 - - 20 1 20

21 1 20 - - 20 1 22

23 1 20 - - 20 1 24

25 1 20 - - 20 1 26

27 1 20 - - 20 1 28

29 1 20 - - 20 1 30

31 1 20 - - 20 1 32

33 1 20 - - 20 1 34

35 1 20 - - 20 1 36

37 3 200 5690 7360 200 3 38

39 - - 5310 9360 - - 40

41 - - 5410 7360 - - 42

A B C SUM %

2872 1435 860 5167 7

0 0 0 0 0

10512 10512 10512 31536 41

13050 14670 12770 40490 52

0 0 0 0 0

26434 26617 24142 77193

26434 26617 24142 77193 100

34 34 31

TOTAL

LIGHTING [L]

RECEPTS [R]

EQUIP. [E]

OTHER

42 000 A ROOM 112

MAINS: MOUNTING:

MCB Surface 42

MAX. NO. OF CIRCUITS: MANUFACTURER:

NEUTRAL RATING: PANEL DESCRIPTION:

100% 400AMP POWER PANEL

PANEL A.I.C. RATING: LOCATION:

DP 208Y/120 3 4

PANEL NAME: VOLTAGE PHASE: WIRE:

EXTERIOR LIGHTING

ROOMS 109,110,111,112,113,114,115

ROOM 103,107

ROOM 101,102,104,105,106,117,118

SPARE

SPARE

ROOM 108

EXIT SIGNS

ROOM 103

SPARE

SPARE

SPARE

PANEL "PP1"

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

ACC-1

AHU#1

DESCRIPTION DESCRIPTION

AHU#2

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

DEMAND

ADDITIONAL

SPARE

PANEL "PP2"

Total

Panel Schedule

BRANCH VA Load Load VA BRANCH NO POLES BKR A B C Type Type A B C BKR POLES NO.

1 1 20 500 R - 20 1 2

3 1 20 860 R R 1000 20 1 4

5 1 20 1000 R R 1000 20 1 6

7 1 20 1000 R R 1000 20 1 8

9 1 20 1000 R R 1000 20 1 10

11 1 20 1000 R R 1000 20 1 12

13 1 20 1000 R R 1000 20 1 14

15 1 20 1000 R R 500 20 1 16

17 1 20 1000 R R 500 20 1 18

19 1 20 1000 R R 500 20 1 20

21 1 20 1000 R - 20 1 22

23 1 20 - - 20 1 24

25 1 20 500 R - 20 1 26

27 1 20 1000 R - 20 1 28

29 1 30 360 R - 20 1 30

31 1 20 360 R - 20 1 32

33 1 20 1000 R - 20 1 34

35 1 20 500 R - 20 1 36

37 1 20 1000 R - 20 1 38

39 1 20 1000 R - 20 1 40

41 1 20 1000 R - 20 1 42

A B C SUM %

0 0 0 0 0

7860 9360 7360 24580 100

0 0 0 0 0

0 0 0 0 0

0 0 0 0 0

7860 9360 7360 24580

7860 9360 7360 24580 100

32 38 30

TOTAL

LIGHTING [L]

RECEPTS [R]

EQUIP. [E]

OTHER

42 000 A ROOM 112

MAINS: MOUNTING:

MLO Surface 42

MAX. NO. OF CIRCUITS: MANUFACTURER:

NEUTRAL RATING: PANEL DESCRIPTION:

100% 225AMP POWER PANEL

PANEL A.I.C. RATING: LOCATION:

PP2 208Y/120 3 4

PANEL NAME: VOLTAGE PHASE: WIRE:

ROOM 114

ROOM 114

ROOM 103

ROOM 103

ROOM 105

SPARE

ROOM 103

ROOM 103

ROOM 102,103

ROOM 116

ROOM 108

ROOM 117

ROOM 102

ROOM 104

ROOM 103

ROOM 103

ROOM 107 RECEPT

ROOM 103 RECEPT

ROOM 116

ROOM 117

SPARE

ROOM 105,108

ROOM 108

ROOM 108

DESCRIPTION DESCRIPTION

ROOM 108

ROOM 108

ROOM 108

ROOM 103 FLR BOXES

ROOM 103 FLR BOXES

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

DEMAND

ADDITIONAL

SPARE

SPARE

SPARE

SPAREROOM 105

ROOM 104,105

Total

Panel Schedule

BRANCH VA Load Load VA BRANCH NO POLES BKR A B C Type Type A B C BKR POLES NO.

1 1 20 720 R R 180 20 1 2

3 1 20 180 R E 150 20 3 4

5 1 20 180 R E 150 - - 6

7 1 20 540 R E 150 - - 8

9 1 20 1260 R E 300 20 3 10

11 1 20 1260 R E 300 - - 12

13 1 20 200 R E 300 - - 14

15 1 20 900 R R 900 20 1 16

17 1 20 1080 R R 180 20 1 18

19 1 20 1080 R E 162 20 1 20

21 1 20 1080 R 200 20 1 22

23 1 20 1080 R 200 20 1 24

25 1 20 1260 R 500 20 1 26

27 1 20 180 R 500 20 1 28

29 1 20 1080 R 500 20 1 30

31 1 20 - 500 20 1 32

33 1 20 - - 20 1 34

35 1 20 - - 20 1 36

37 1 20 1260 R - 20 1 38

39 1 20 360 R - 20 1 40

41 1 20 100 - 20 1 42

A B C SUM %

0 0 0 0 0

5240 4860 4860 14960 79

612 450 450 1512 8

1000 700 800 2500 13

0 0 0 0 0

6852 6010 6110 18972

6852 6010 6110 18972 100

36 32 32

TOTAL

LIGHTING [L]

RECEPTS [R]

EQUIP. [E]

OTHER

42 000 A ROOM 112

MAINS: MOUNTING:

MLO Surface 42

MAX. NO. OF CIRCUITS: MANUFACTURER:

NEUTRAL RATING: PANEL DESCRIPTION:

100% 225AMP POWER PANEL

PANEL A.I.C. RATING: LOCATION:

PP1 208Y/120 3 4

PANEL NAME: VOLTAGE PHASE: WIRE:

ROOM 112

ROOM 115

ROOM 115 REFRIGERATOR

ROOM 115

ROOM 105

ROOM 106

ROOM 103

ROOM 103

EWC

ROOM 116,117

COLD WATER PUMP

SPARE

SPARE

ROOM 108

ROOM 109,110,111

ROOM 108 VENDING

ROOM 108

SPARE

ROOM 102,117

ROOM 102,101,104

ROOM 115

HOT WATER PUMP

DESCRIPTION DESCRIPTION

ROOM 116

ROOM 108 VENDING

DDC CONTROL PNL

HEAT CABLE

HEAT CABLE

EF-1

EF-2

PA SYSTEM

BOILER

SPARE

DEMAND

ADDITIONAL

SPARE

SPARE

SPARE

SPAREROOM 112 WATER HEATER

EXTERIOR RECEPTACLES

Total

2009 Construction
01-G-001COVER TBI2
02-C-101BOR-TBI2
03-C-102SITE-TBI2
04-C-103DRAIN-TBI2
08-S-001NOTE-TBI2
010-A-001GEN-TBI2
011-A-101FLP-TBI2
012-A-102RFP-TBI2
013-A-103RCP-TBI2
014-A-201ELV-TBI2
015-A-301SEC-TBI2
016-A-401ELP-TBI2
017-A-501INT-TBI2
018-A-502EXT-TBI2
019-A-503EXT-TBI2
020-A-601SCH-TBI2
021-M-001L-TBI2
022-M-101FP-TBI2
023-M-102FP-TBI2
024-M-601SCH-TBI2
025-P-001GEN-TBI2
029-E-001LTG-TBI2
030-E-101PWR-TBI2
032-E-501DET-TBI2
033-E-502DET-TBI2
034-E-503DET-TBI2
035-E-504DET-TBI2
036-E-601OLINE-TBI2
037-E-602SCH-TBI2
038-F-101COMM-TBI2
039-F-102FLP-TBI2