Headquarters III Corps, Fort Hood Directorate of Public Works (DPW)
Attachment 1
SPECIFICATIONS
Appendix A
Wdzƭȅ 1м, 201н
Directorate of Public Works Engineering Division
US Army, III Corps 4612 Engineer Dr.
Fort Hood, TX 76544
APPENDIX “A” TABLE OF CONTENTS
SECTION 1 - GENERAL
PAGE NUMBER DESCRIPTION
101‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Sample Submittal Register 102‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Form 4025, Transmittal Sheet 104‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Contract Project Schedule Form 106‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Contract Bi-Weekly Progress Report Form 107 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Refrigeration Equipment Service Log 108 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Refrigeration Recovery Form 111 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Emissions Inventory Sheet 115 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Contractor Hazardous Materials Log 117 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Landfill permit 118 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Customer Service Inspection Certificate
(CSI)
120 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Coordination for Land Excavation (Dig permit) 122 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Landscaping on Fort Hood 133 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Accident Investigation Report 137 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Sample Contractor Quality Control Report 139 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Preparatory Phase Checklist 142 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Initial Phase Checklist 144 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Operation and Maintenance Instructions
Receipt 145 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Fort Hood Key SOP
SECTION 2 – NEC
201 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐NEC Installation Guidelines (Formally DOIM)
SECTION 3 – AW
301 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐American Water Design Guide
S U
B M
IT
TA
L
FO
R M
,J an
P R
E V
IO
U
S E
D
IT
IO
N
IS
O
B S
O
LE
TE
P
A G
E
O F
P
A G
E S
JO
C
M as te r S pe ci fic at io ns
.0
S
D -0
P re co ns tru ct io n S ub m itt al s 3.
P ro je ct S ch ed ul e
SU
B
M
IT
TA
L
R
EG
IS
TE
R C
O N
TR
A
C T
N O
TI
TL
E A
N D
L O
C A
TI
O
N C
O N
TR
A
C
TO
R
C O
N
TR
A C
TO
R
S
C H
E D
U
LE
D A
TE
S
C O
N
TR
A C
TO
R
A C
TI
O
N A
P P
R O
V
IN
G A
U
TH
O R
IT
Y
A C T I V I T Y N O
T R A N S M I T T A L N O
S P E C S E C T
D E
S C
R
IP
TI
O
N
IT
E
M S
U B
M
IT
TE
D
P A R A G R A P H
C L A S S I F I C A T I O N
G O V T O R A / E R E V W R S
U B
M
IT
A P
P R
O V
A L
N E
E D
E D
B Y
M A
TE
R
IA
L
N E
E D
E D
B Y
A C T I O N C O D E
D A
TE
O
F A
C
TI
O N
D A
TE
F
W D
TO
A
P P
R A
U
TH
D A
TE
R
C D
FR
O
M C
O N
TR
D A
TE
F
W D
TO
O
TH
E
R R
E V
IE
W
E R
D A
TE
R
C D
FR
O
M O
TH
R
E V
IE
W
E R
A C T I O N C O D E
D A
TE
O
F A
C
TI
O N
M A
IL
E
D
TO
C O
N
TR
D A
TE
R
C D
FR
M
A P
P R
A U
TH
R
E M
A R
K S
(a
(b
(c
(d
(e
(f) (g
(h
(i)
(j) (k
(l)
(m
(n
(o
(p
(q
(r
BOB.MILLENBACH
Typewritten Text ia
Feb 2011Feb 2011
Fort Hood Refrigerant Equipment Service Log DPW Maintenance Shop #________________
Certified Technician Name Equipment Maintenance/Service/Repair Make
Building Number or Location Model Number Date Leak Discovered / Unit Serviced Serial Number Does serviced unit contain more than 50 lbs. refrigerant? Yes / No Refrigerant Type
Equipment Duty Type? Location of Leak on Equipment Comfort Cooling Commercial Industr Unit Refrigerant Full Cl/Process harge Per Circuit 1 2 3
Service Order Number (SO#) Refrigerant Recovered (lbs.oz) Per Circuit 1 2 3 Recovered Refrigerant was: Re-used Taken to C.U.
Equipment Removal/Disposal Recovery Cylinder # Compressor Serial Number Vacuum Level Achieved (In Hg) Make Refrigerant Added (lbs.oz) Per Circuit 1 2 3 Model Number Refrigerant Added Cylinder # Serial Number Detailed Description of Repairs:
Refrigerant Type Vacuum Level Achieved (inches Hg) Amount of Refrigerant Added Amount of Refrigerant Recovered Cylinder # N tNotes:
Initial Leak Verification (Conducted after repair but before charging) Leak repaired ? Yes / No Date:
Method used for verification
New Equipment Installation If no, what action taken Make Follow-up Leak Verification (Conducted at normal operating capacity) Model Number Initial Leak repair effective ? Yes / No Date:
Serial Number Method used for verification Refrigerant Type If no, what action taken Amount of Refrigerant Added Amount of Refrigerant Recovered In compliance with the requirements of the Clean Air Act, Section 608, I certify that the refrigerant has been handled in accordance with U.S. EPA regulations at
40 CFR 82.156.
Refrigerant Charge per Circuit 1 2 3 4 Cylinder # Notes:
Signature of Certified Technician
Signature of Supervisor/Reviewer
Form Approved OMB No. 2060-0256
ENVIRONMENTAL PROTECTION AGENCY
REFRIGERANT RECOVERY OR RECYCLING DEVICE
ACQUISITION CERTIFICATION FORM
EPA regulations require establishments that service or dispose of refrigeration or air-conditioning equipment to certify that they have acquired recovery or recycling devices that meet EPA standards for such devices. To certify that you have acquired equipment, please complete this form according to the instructions and mail it to the appropriate EPA Regional Office. BOTH THE INSTRUCTIONS AND MAILING ADDRESSES CAN BE FOUND ON THE
REVERSE SIDE OF THIS FORM.
PART 1: ESTABLISHMENT INFORMATION
Name of Establishment Street
(Area Code) Telephone Number City State Zip Code
Number of Service Vehicles Based at Establishment County
PART 2: REGULATORY CLASSIFICATION
Identify the type of work performed by the establishment. Check all boxes that apply.
9 Type A - Service small appliances 9 Type B - Service refrigeration or air-conditioning equipment other that small appliances 9 Type C- Dispose of small appliances 9 Type D - Dispose of refrigeration or air-conditioning equipment other than small appliances
PART 3: DEVICE IDENTIFICATION
Name of Device(s) Manufacturer Model Number Year Serial Number (if any) Check Box if Self-Contained
1. G
2. G
3. G
4. G
5. G
PART 4: CERTIFICATION SIGNATURE
I certify that the establishment in Part 1 has acquired the refrigerant recovery or recycling device(s) listed in Part 2, that the establishment is complying with Section 608 regulations, and that the information gives is true and correct.
Signature of Owner/Responsible Officer Date Name (Please Print) Title
INSTRUCTIONS
Part 1: Please provide the name, address, and telephone number of the establishment where the refrigerant recovery or recycling device(s) is (are) located. Please complete one form for each location.
State the number of vehicles based at this location that are used to transport technicians and equipment to and from service sites.
Part 2: Check the appropriate boxes for the type of work performed by technicians who are employees of the establishment. The term “small appliance” refers to any of the following products tat are fully manufactured, charged, and hermetically sealed in a factory with five pounds or less of refrigerant:
refrigerators, and freezers designed for home use, room air conditioners (including window air conditioners and packaged terminal air conditioners), packaged terminal heat pumps, dehumidifiers, under-the-counter ice makers, vending machines, and drinking water coolers.
Part 3: For each recovery or recycling device acquired, please list the name of the manufacturer of the device, and (if applicable) its model number and serial number.
If more that seven devices have been acquired, please fill out an additional form and attach it to this one. Recovery devices that are self-contained should be listed first and should be identified by checking the box in the last column on the right. Self-contained recovery equipment means refrigerant recovery or recycling equipment that is capable of removing te refrigerant from an appliance without the assistance of components contained in the appliance. On the other hand, system-dependent recovery equipment means refrigerant recovery equipment that requires the assistance of components contained in an appliance to remove the refrigerant from the appliance.
If the establishment has been listed as Type B and/or Type D in Part 2, then the first device listed in Part # must be a self-contained device and identifies as such by checking the box in the last column on the right.
If any of the devices are homemade, they should be identified by writing “homemade” in the column provided for listing the name of the device manufacturer. Type A or Type B establishments can use homemade devices manufactured before November 15, 1993. Type C or Type D establishments can use homemade manufactured anytime. If, however, a Type C or Type D establishment is using homemade equipment manufactured after November 15, 1993, then it must not use these devices for service jobs.
EPA REGIONAL OFFICES
Send your form to the EPA office listed under the state or territory in which the establishment is located.
Connecticut, Maine, Massachusetts, New Hampshire, Rhode Island, Vermont
CAA 608 Enforcement Contact: EPA Region I; Mail Code SEA; JFK Federal Building; One Congress Street, Suite 1100; Boston, MA 02114-2023
Arkansas, Louisiana, New Mexico, Oklahoma, Texas
CAA 608 Enforcement Contact: EPA Region VI; Mail Code 6EN-AA; 1445 Ross Ave., Suite 1200; Dallas, TX 75202
New York, New Jersey, Puerto Rico, Virgin Islands
CAA 608 Enforcement Contact: EPA Region II; Mail Code 2DECA-AC; 290 Broadway; New York, NY 10007-1866
Iowa, Kansas, Missouri, Nebraska
CAA 608 Enforcement Contact: EPA Region VII; Mail Code APCOARTD; 901 North Fifth Street; Kansas City, KS 66101
Delaware, District of Columbia, Maryland, Pennsylvania, Virginia, West Virginia
CAA 608 Enforcement Contact: EPA Region III-Wheeling Office; Mail Code 3AP12; 303 Methodist Building; 11th and Chapline Streets; Wheeling, WV 26003
Colorado, Montana, North Dakota, South Dakota, Utah, Wyoming
CAA 608 Enforcement Contact: EPA Region VIII; Mail Code 8ENF-T; 999 18th
Street, Suite 500; Denver, CO 80202
Alabama, Florida, Georgia, Kentucky, Mississippi, North Carolina, South Carolina, Tennessee
CAA 608 Enforcement Contact: EPA Region IV; Mail Code APT-AE; 61 Forsyth Street, SW; Atlanta, GA 30303-8960
American Samoa, Arizona, California, Guam, Hawaii, Nevada
CAA 608 Enforcement Contact: EPA Region IX; Mail Code AIR-5; 75 Hawthorne Street; San Francisco, CA 94105
Illinois, Indiana, Michigan, Minnesota, Ohio, Wisconsin
CAA 608 Enforcement Contact: EPA Region V; Mail Code AE-17J; 77 West Jackson Blvd.; Chicago, IL 60604
Alaska, Idaho, Oregon, Washington
CAA 608 Enforcement Contact: EPA Region X; Mail Code OAQ-107; 1200 Sixth Ave.; Seattle, WA 98101
BOB.MILLENBACH
Typewritten Text
Proposed Project Emissions Inventory Questionnaire for New Sources
DPW, ENV Air Emission Inventory Questionnaire Form-1, Rev date: 1Jun2012
Title V Operating Permit / New Source Review
Purpose: This form is used to capture detailed information about new air emission sources which have the potential to emit pollutants into the atmosphere. Information from this form will be used to address permit requirements such as new applications, notifications, amendments or revisions under Fort Hood’s Title V Air Operating Permit # O-01659. The form shall be completed as soon as required equipment data is known to allow sufficient time to prepare permit applications for new sources prior to startup. Reminder: Some types of emission sources (e.g. boilers, generators and tanks) may also require startup or initial notifications to the Environmental Protection Agency.
Indicate proposed emission source type and complete all applicable fields for each piece of equipment. Complete the questionnaire sheet for each emission source type in this facility. Forms must be returned to the DPW, Environmental Division, Air Quality Program, Bldg 4622, (254) 287-8714 or (254) 553-1581.
Requestor:____________________Date:___/___/_____Phone:________________Project#:_____________________________________
Building#:___________________________ Descriptive Name of Facility:___________________________________________
Location of Facility:______________________ UTM Coordinate: Zone: 14 Northing: Easting:
AUTHORIZATION FOR STARTUP
Authorized by: ____________________ Title: ______________________
Signature: ________________________ Date of Startup: ___/____/________
Received on ____/____/_____ Permitted by _______________________ (Permit By Rule or Permit)
AUTHORIZATION TO PROCEED WITH CHANGE
Authorized by: ____________________ Title: ______________________
Signature: ________________________ Date: ____/_____/_________
ENV Use Only
INTERNAL COMBUSTION UNITS (e.g. Generators, Test Cells, Covered by 30 TAC 106.511 and 30 TAC 106.512 ) Make Model Serial # Power Rating: Kw; Horsepower: HP Engine Type: 4SLB, 4SRB, 2SLB, Other (Circle one) Fuel Type: Natural Gas/Propane/Diesel; Integrated Fuel Tank Capacity: ____gallons Make Model Serial # Power Rating: Kw; Horsepower: HP Engine Type: 4SLB, 4SRB, 2SLB, Other (Circle one) Fuel Type: Natural Gas/Propane/Diesel; Integrated Fuel Tank Capacity: ____gallons Make Model Serial # Power Rating: Kw; Horsepower: HP Engine Type: 4SLB, 4SRB, 2SLB, Other (Circle one) Fuel Type: Natural Gas/Propane/Diesel; Integrated Fuel Tank Capacity: ____gallons
Separate Fuel Tank(s): YES / NO (circle one) Complete Separate Questionnaire for Each Tank
Seasonal Operating Percentage for This Emission Point:
Spring % Summer % Fall % Winter % Note: Total Must Equal 100% Normal Operating Schedule: Start Time hours/day days/week _____weeks/year __ Normal Operating Rate:____gallons or CuFT/yr
FUEL STORAGE TANKS (Covered by 30 TAC 106.473 , 30 TAC 106.478 and 30 TAC Chap 115) Make _______ Model ________________Serial#____________________ Tank Volume: _____gals; Tank Dimensions (ft): Diameter: ____Length:___ Height:______ Make _______ Model ________________Serial#____________________ Tank Volume: _____gals; Tank Dimensions (ft): Diameter: ____Length:___ Height:______ Make _______ Model ________________Serial#____________________ Tank Volume: _____gals; Tank Dimensions (ft): Diameter: ____Length:___ Height:______
Tank Type: Aboveground / Underground (circle one);
Vapor Control Equipped: YES / NO (circle one) Roof Type: Horizontal Fixed Roof / Vertical Fixed Roof / Internal Floating Roof / Pressure Tank External Floating Roof(circle one)
Seasonal Operating Percentage for This Emission Point:
Spring % Summer % Fall % Winter % Note: Total Must Equal 100% Normal Operating Schedule: Start Time hours/day days/week weeks/year Normal Operating Rate: gallons/year Maximum Operating Rate: gallons/hour
EXTERNAL COMBUSTION UNITS (e.g. Boilers & Heaters Covered by 30 TAC 106.102 or
30 TAC 106.183)
Fuel Type: Natural Gas / Diesel (circle one) Make: __ Model:__________Serial#:__________Input Rating:___ MMBTUH
Height of Stack: ___ ft ; Diameter of Stack:____ft; Stack Velocity: __ft / sec Make: __ Model:__________Serial#:__________Input Rating:___ MMBTUH Height of Stack: ___ ft ; Diameter of Stack:____ft; Stack Velocity: __ft / sec
Make: __ Model:__________Serial#:__________Input Rating:___ MMBTUH
Seasonal Operating Percentage for This Emission Point:
Spring % Summer % Fall % Winter % Note: Total Must Equal 100% Normal Operating Schedule: Start Time hours/day days/week _ _ _ _ _ weeks/year
Normal Operating Rate: ________ Cuft or gallons/year
FUEL DISPENSING UNITS (Covered by 30 TAC 106.412) Make:__________Model:_____________Serial#:___________________ Make:__________Model:_____________Serial#:___________________ Make:__________Model:_____________Serial#:___________________ Make:__________Model:_____________Serial#:___________________
Fuel Type: MUR / Diesel / JP-8 / Other (Circle one) Dispensing Type: Retail / Bulk (circle one) Vapor Control Equipped : YES / NO (circle one) Dispenser Pump rate: gallons/minute
Seasonal Operating Percentage for This Emission Point:
Spring % Summer % Fall % Winter % Note: Total Must Equal 100% Normal Operating Schedule: Start Time hours/day days/week weeks/year _______Normal Operating Rate:______gallons/year http://www.tceq.texas.gov/permitting/air/permitbyrule/subchapter-w/portable_power.html http://www.tceq.texas.gov/permitting/air/permitbyrule/subchapter-w/stationary_eng_turb.html http://info.sos.state.tx.us/pls/pub/readtac$ext.TacPage?sl=R&app=9&p_dir=&p_rloc=&p_tloc=&p_ploc=&pg=1&p_tac=&ti=30&pt=1&ch=106&rl=473 http://info.sos.state.tx.us/pls/pub/readtac$ext.TacPage?sl=R&app=9&p_dir=&p_rloc=&p_tloc=&p_ploc=&pg=1&p_tac=&ti=30&pt=1&ch=106&rl=478 http://info.sos.state.tx.us/pls/pub/readtac$ext.ViewTAC?tac_view=4&ti=30&pt=1&ch=115 http://www.tceq.texas.gov/permitting/air/permitbyrule/subchapter-c/comfort_heating.html http://www.tceq.state.tx.us/permitting/air/permitbyrule/subchapter-g/big_boilers.html http://info.sos.state.tx.us/pls/pub/readtac%24ext.TacPage?sl=R&app=9&p_dir&p_rloc&p_tloc&p_ploc&pg=1&p_tac&ti=30&pt=1&ch=106&rl=433 http://info.sos.state.tx.us/pls/pub/readtac%24ext.TacPage?sl=R&app=9&p_dir&p_rloc&p_tloc&p_ploc&pg=1&p_tac&ti=30&pt=1&ch=106&rl=433 http://info.sos.state.tx.us/pls/pub/readtac%24ext.TacPage?sl=R&app=9&p_dir&p_rloc&p_tloc&p_ploc&pg=1&p_tac&ti=30&pt=1&ch=106&rl=433 http://www.tceq.texas.gov/permitting/air/permitbyrule/subchapter-r/fuel_dispensing.html
SURFACE COATING OPERATIONS (Covered by 30 TAC 106.433 , 30 TAC 106.436 or
30 TAC 116.110)
Attach approved MSDS of each coating and solvent used in process Particulate Matter Control Efficiency of Booth: % Booth Air Flow Rate: scfm Transfer Efficiency of Paint Gun: % Number of Paint Guns:
Associated Heater: YES / NO (circle one) Complete Separate Questionnaire for Each Heater Associated Gun Cleaner: YES / NO (circle one) Complete Separate Questionnaire for Each Cleaner on degreaser section Seasonal Operating Percentage for This Emission Point:
Spring % Summer % Fall % Winter % Note: Total Must Equal 100% Normal Operating Schedule: Start Time hours/day________ days/week_______weeks/year______ Normal Operating Rate: ________gallons/year (each coating and solvent)
REFRIGERATION EQUIPMENT (e.g. Air Conditioning, Freezer) (Covered by 30 TAC 106.103)
Make _______ Model ________________Serial#____________________ No. of compressors:
Refrigerant Type: _____ Amount of Charge:____ lbs; Initial Charge Date:___/___/____
Make _______ Model ________________Serial#____________________ No. of compressors:
Refrigerant Type: _____ Amount of Charge:____ lbs; Initial Charge Date:___/___/____
Make _______ Model ________________Serial#____________________ No. of compressors:
Refrigerant Type: _____ Amount of Charge:____ lbs; Initial Charge Date:___/___/____
Make _______ Model ________________Serial#____________________ No. of compressors:
Refrigerant Type: _____ Amount of Charge:____ lbs; Initial Charge Date:___/___/____
WELDING OPERATIONS (Covered by 30 TAC 106.227)
Attach approved MSDS of each welding rod type used in process Make: __ Model:__________Serial#:_________________
Make: __ Model:__________Serial#:_________________
Make: __ Model:__________Serial#:_________________
Particulate Matter Control Efficiency of hood (if available): _______% Exhaust Fan Ventilation Rate :_ scfm Acetylene on hand:___lbs of gas Oxygen on hand:____lbs of gas
Seasonal Operating Percentage for This Emission Point:
Spring % Summer % Fall % Winter % Note: Total Must Equal 100% Normal Operating Schedule: Start Time hours/day days/week _ _ _ _ weeks/year____ Normal Operating Rate: # of rods/year
DEGREASERS (Covered by 30 TAC 106.454)
Attach MSDS of proposed degreaser solvent Degreaser Type: Parts Cleaner / Paint Gun Cleaner (circle one)
Make:___________Model:________________Serial #:________________
Make:___________Model:________________Serial #:________________
Make:___________Model:________________Serial #:________________
Make:___________Model:________________Serial #:________________
Seasonal Operating Percentage for This Emission Point:
Spring _____% Summer _____% Fall _____% Winter _____% Note: Total Must Equal 100%
Normal Operating Schedule: Start Time_____hours/day _____days/week _____weeks/year____ Normal Operating Rate: _______________gallons/year http://www.tceq.texas.gov/permitting/air/permitbyrule/subchapter-s/surface_coat_facility.html http://www.tceq.texas.gov/permitting/air/permitbyrule/subchapter-s/auto_body.html http://info.sos.state.tx.us/pls/pub/readtac$ext.TacPage?sl=T&app=9&p_dir=P&p_rloc=96499&p_tloc=&p_ploc=1&pg=9&p_tac=&ti=30&pt=1&ch=116&rl=110 http://info.sos.state.tx.us/pls/pub/readtac%24ext.TacPage?sl=R&app=9&p_dir&p_rloc&p_tloc&p_ploc&pg=1&p_tac&ti=30&pt=1&ch=116&rl=110 http://www.tceq.state.tx.us/assets/public/permitting/air/PermitsByRule/one_liners.pdf http://info.sos.state.tx.us/pls/pub/readtac%24ext.TacPage?sl=R&app=9&p_dir&p_rloc&p_tloc&p_ploc&pg=1&p_tac&ti=30&pt=1&ch=106&rl=436 http://www.tceq.texas.gov/permitting/air/permitbyrule/subchapter-i/soldering_brazing_welding.html http://info.sos.state.tx.us/pls/pub/readtac%24ext.TacPage?sl=R&app=9&p_dir&p_rloc&p_tloc&p_ploc&pg=1&p_tac&ti=30&pt=1&ch=106&rl=433 http://info.sos.state.tx.us/pls/pub/readtac%24ext.TacPage?sl=R&app=9&p_dir&p_rloc&p_tloc&p_ploc&pg=1&p_tac&ti=30&pt=1&ch=106&rl=433 http://info.sos.state.tx.us/pls/pub/readtac%24ext.TacPage?sl=R&app=9&p_dir&p_rloc&p_tloc&p_ploc&pg=1&p_tac&ti=30&pt=1&ch=106&rl=433 http://www.tceq.texas.gov/permitting/air/permitbyrule/subchapter-t/degrease_units.html
FIN, EPN and CIN determination comes from Emissions Inventory Guidelines
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
FIN # _________________ EPN #_________________ CIN #__________________
ENV Use Only http://www.tceq.texas.gov/airquality/point-source-ei/psei.html
PRIME COMPANY NAME: _______________________________ CONTRACT NO: _______________________
PROJECT TITLE/LOCATION: ___________________________________________________________________
Material Name Manufacturer MSDS State Number
Average Max Daily Daily
*Contractor(s) certifies that the hazardous material(s) removed from installation will be used/reused for its intended purpose.
Submitted By: Phone: Fax:_______ Date:
Printed Name
Contracting Officer Phone: Fax:_______ or Representative Page____of____
CONTRACTOR HAZARDOUS MATERIAL INVENTORY & CONSUMPTION LOG
(EPCRA/E.O. 13423)
(container size-quantity of) Storage Quantity Quantity (lbs/gals) used in CY [ ](i.e. Liquid, Solid, Gas)
Company Using Material Listed Above Company Representative's Signature
PRIME COMPANY NAME: _______________________________ CONTRACT NO: _______________________
PROJECT TITLE/LOCATION: ___________________________________________________________________
Material Name Manufacturer MSDS State Number
Average Max Daily Daily
Page____of____
(container size-quantity of) Storage Quantity Quantity (lbs/gals) used in CY [ ](i.e. Liquid, Solid, Gas)
Continuation Sheet
CONTRACTOR HAZARDOUS MATERIAL INVENTORY & CONSUMPTION LOG
(EPCRA/E.O. 13423)
LANDFILL PERMIT
DPW COR POC and telephone phone number: _______________________________________ Contract Name: ________________________________________________________________ Contract Number: _______________________________________________________________ Contract completion date or end of authorization date: __________________________________ Building or areas affected (i.e., Soldier's Development Center):
Prime Contractor's Name: ________________________________________________________ Contractor POC and phone (i.e. someone on site that can get immediate action):
Appendix D: Customer Service Inspection Certificate (30 TAC §290.47(d))
Customer Service Inspection Certificate Name of PWS _______________________________________PWS I.D.# ______________ Location of Service ______________________________________________________ Reason for Inspection:
New construction. __ Existing service where contaminant hazards are suspected __ Major renovation or expansion of distribution facilities __
I _____________________________, upon inspection of the private water distribution facilities connected to the aforementioned public water supply do hereby certify that, to the best of my knowledge:
(1) No direct connection between the Compliance Non-Compliance public drinking water supply and a potential source of contamination exists. Potential sources of contamination are isolated from the public water system by an air gap or an appropriate backflow prevention assembly in accordance with Commission regulations.
(2) No cross-connection between the public drinking water supply and a private water system exists. Where an actual air gap is not maintained between the public water supply and a private water supply, an approved reduced pressure-zone backflow prevention assembly is properly installed and a service agreement exists for annual inspection and testing by a certified backflow prevention assembly tester.
(3) No connection exists which would allow the return of water used for condensing, cooling or industrial processes back to the public water supply.
(4) No pipe or pipe fitting which contains more than 8.0% lead exists in private water distribution facilities installed on or after July 1, 1988.
(5) No solder or flux which contains more than 0.2% lead exists in private water distribution facilities installed on or after July 1, 1988.
I further certify that the following materials were used in the installation of the private water distribution facilities:
Service lines Lead __ Copper __ PVC __ Other __ �Solder Lead __ Lead Free __ Solvent Weld __ Other __
I recognize that this document shall become a permanent record of the aforementioned Public Water System and that I am legally responsible for the validity of the information I have provided.
Remarks:
Signature of Inspector
Registration Number
Title
Type of Registration
Date
FHT Form 200-X10, April 2004 (DPW) Replaces FHT Form 420-X10
COORDINATION FOR LAND EXCAVATION & WATER USE
(III Corps and FH Reg 200-1)
CONTROL NUMBER
TELEPHONE
NAME, RANK, TITLE, AND ORGANIZATION OF REQUESTER
PROJECTED DATES OF EXCAVATION OR WATER USE
PURPOSE AND DESCRIPTION OF EXCAVATION OR WATER USE (PROJECT NO./CONTRACT NO./TITLE, ETC.)
AREA OF LAND DISTURBANCE = _________ ACRES DPW Point Of Contact:_______________________________________ Note: Permit Expires After 30 Days of Approved Start Date
EXCAVATION
� I propose to dig at the locations depicted in the attached map, sketch, or overlay (For military operations, plot digging locations on transparent overlays that include two grid register marks using standard 1:50,000 topographic maps).
� I understand that the proposed digging or excavation is a requirement within the scope of work to be accomplished. I will not dig or excavate before receiving written approval from the Directorate of Public Works (DPW). I understand my responsibilities and obligations pursuant to safety, property damage, personal injury, and life-threatening hazards associated with digging in the vicinity of underground utilities (including utilities such as electrical cables and pipes containing natural gas, water, sewer, liquefied fuels, and refrigerants). Severe injuries, death, and extensive property damage may occur as a result of digging through underground utilities. I am responsible for damages caused to persons or property as a result of my fault or negligence. If the exact locations of underground utilities are unknown, I will perform whatever work is necessary to determine exact locations and avoid damaging utilities.
� Unless otherwise permitted, I will not excavate within 50 meters of streams, natural drains, roads, and tank trails. I will not dig or deposit excavated spoil within 10 meters of trees.
� If archaeological resources (arrowheads, charcoal, bones, etc.) are discovered during excavation, I or my representative will notify DPW, 287- 1092, and suspend disturbance of the finding until DPW issues guidance.
� Upon completion, I will restore the excavation site including backfilling, reshaping, and seeding to conform to surrounding topography.
� For construction activities that will result in land disturbance (clearing, grading or excavating) of one acre or more, or that are part of a larger common plan of development that will ultimately disturb one or more acres of land, I will comply with the provisions of the TPDES General Permit, TXR150000, to discharge storm water from construction sites, and I will coordinate with DPW-Environmental Division, 287-6499.
WATER USE
� I propose to take surface water from the location depicted in the attached map, sketch, or overlay. Include dates and amounts of proposed water use.
� I understand that the proposed water supply point is a requirement within the scope of work to be accomplished. I will not divert or draw any water before receiving written approval from the Directorate of Public Works (DPW).
� I understand that in addition to this permit, a Temporary Water Use Permit may be required from TCEQ, depending on the proposed water use.
SIGNATURE OF REQUESTER DATE
REVIEWED OR INSPECTED BY
(All blocks must be signed for Excavation permit. Natural Resources & Environmental Mgmt only for Water Use permit.)
NATURAL RESOURCES Sprint ELECTRIC GAS RANGE DIVISION
ENVIRONMENTAL MGMT CULTURAL RESOURCES DOIM TV CABLE WATER & SEWER
Approved under the following conditions Disapproved for the following reasons
APPROVED BY (Range Division for Training Activities, Range Safety for Live Fire Activities, DPW for all other Activities)
DATE
FHT Form 200-X10
DEP ARTMENT OF THE ARMY
HEADQUARTERS, U.S. ARMY GARRISON
BUILDING 1001 ROOM W321
FORT HOOD, TEXAS 76544-5000
REPLY TO
ATfENTION OF
MAY 1 O 200~AFZF-PW-ENV
MEMORANDUM FOR SEE DISTRIBUTION
SUBJECT: Memorandum of Instruction (MOl) Landscaping on Fort Hood
1. Purpose. To establish procedures which allow units and other Fort Hood areas to landscape with vegetation that is native to the Fort Hood region.
2. Applicability. This MOl applies to all units, Directorates, and Family Housing on Fort Hood.
3, Responsibilities
a. Draw plans of the landscape area to facilitate plant placement by type and height or growth characteristics and estimate cost.
b. Layout beds or planting sites on the ground
c. Obtain an approved excavation permit (FH 420-X10), d Plant and water,
e. Develop long-term maintenance schedule and apply.
4, POC for excavation permits is DPW, Services Division, 287 -9735.
FOR THE COMMANDER'
Encl
DISTRIBUTION:
IAW FH FORM 1853: A
Planting and Care of Trees and Shrubs
1. Locate and mark planting sites and apply for an approved excavation permit (FH 420-X10). A permit is required prior to any digging on Fort Hood and necessary to prevent damage to the underground utility systems.
2. Select the right plants for the right locations. Consider future plant size in relation to conflict with sidewalks, drives, buildings, streets, and overhead utility lines. See the Approved Plant List for guidance on plant heights.
3. Locate and dig holes so that the hole is two to three times the diameter of the container and no deeper than the container. Keep all original topsoil for backfilling. Be certain that hole has rough and uneven edges and is irregular in size, as this will encourage the new roots to spread and not become root-bound within the hole. Plant only as deep as the level of the dirt in the original pot; planting too deeply may kill the plant. See attached diagram.
4. Always handle plants by the container or the ball, never by the stems, as this will damage the plant. If the plant is root-bound, make two cuts across the bottom layer of roots and several cuts along the sides to loosen the roots.
5. Set the plant in the hole vertically and remove the container or the burlap and wire.
Backfill only with the original soil. Do not backfill with compost, peat moss, or other materials. Add one third of backfill soil at a time; tamp very lightly and use slow-running water to settle the soil and help secure the plant. Repeat this process until the hole is full and thoroughly watered.
6. It is recommended that you install a landscape fabric. Place fabric beneath edging such that it covers the entire surface of the bed. Use a fabric, which allows air and water to penetrate and restricts weeds, but do NOT use a solid plastic film.
7. If desired, you may install edging. Metal edging, installed 4 inches below the surface and 2 inches above, is preferred because it will help to keep grass from invading into the planting area. However, stone edging, installed no more than one high, may be installed around individual trees or around shrub beds.
8. Place a 3- to 4-inch-thick layer of mulch around all plants to keep them free of weeds and grass. Use only shredded hardwood mulch, hardwood chips, or cedar mulch. Do not use pine bark mulch. Do not use rock of any type instead of mulch. For planting beds, mulch the entire bed. For individual plantings of trees or shrubs, mulch 2 to 3 feet around the trunk in every direction.
9. For trees, do not use tree stakes or guy wires of any kind. These actually weaken trees. Also, do not wrap any material around the base of the trunk. These encourage problems with insects and diseases. Do not prune trees and shrubs at planting time. Do not paint trees. The only exception to the no staking rule is for very large (greater than 4 inch trunk) balled and burlapped trees. These trees may be staked for a period not to exceed 2 years; after which time, all stakes and guy wires must be removed.
10. Do not plant trees and shrubs without a commitment to care for them. Trees and shrubs will need to be watered when rainfall is not sufficient; a rain of at least 1 inch per week is sufficient. When rainfall is less than 1 inch, each tree and shrub will need to be watered once per week during the summer months and every other week during the fall, winter, and spring months for 1 to 2 years. A slow trickle of water from a water hose for one hour is the preferred method of watering. Sprinkling, especially during the summer months, is very wasteful. More water is lost to evaporation rather than soaking into the soil.
Plant List for Landscaping on Fort Hood
* indicates plants native to Fort Hood
Large Trees Big-tooth maple* Acer grandidentatum interesting leaves; grows 20-50 feet;
needs very little water; golden to red fall color
Bur oak* Quercus macrocarpa very large shade tree; grows 60-80 feet tall and 50 feet spread; needs deep, rich soil; very large leaves; large interesting acorns
Cedar elm* Ulmus crassifolia grows up to 70 feet; upright growth form that is good for narrow spaces; yellow-golden fall color
Chinkapin oak* Quercus muehlenbergii grows up to 50 feet; prefers deeper soil, but will grow in dry soil; large leaves;
yellow to brown fall color
Escarpment black cherry
Prunus serotina var.
eximia grows up to 25 feet; white flower clusters followed by small black cherries; yellow fall color; needs moist soil
Lacey oak Quercus laceyi (or Q. glaucoides) grows up to 20 feet; slow growth rate;
interesting blue-green leaf color; not susceptible to oak wilt
Monterrey oak, or Mexican white oak
Quercus polymorpha grows up to 40 feet; deciduous to evergreen; prefers well-drained soil; the young leaves are bronze in color; not susceptible to oak wilt
Pecan* Carya illinoenensis grows up to 90 feet; large shade tree;
needs deep, rich soil; birds and people eat the nuts
Plateau live oak* Quercus fusiformis (or Q. virginiana) grows up to 30 feet; evergreen; large shade tree; needs very little water;
susceptible to oak wilt
Texas white ash* (NOT Arizona ash, or Fan Tex ash)
Fraxinus texensis (NOT Fraxinus velutinus) grows 40-50 feet; grows fairly fast; yellow to orange fall color; needs very little water
Small Trees Blanco crabapple Pyrus ioensis var.
texana (Malus ioensis var.
texana) sun; grows up to 12 feet; pink flowers in the spring and interesting fruits in the fall
Carolina buckthorn* Rhamnus caroliniana (Frangula caroliniana) sun or shade; grows up to 15 feet; large glossy leaves; small purple fruits in late fall
Desert willow Chilopsis linearis sun or part shade; grows up to 15 feet;
large showy pink flowers; does not like to be over watered
Eve’s necklace* Sophora affinis sun or shade; grows up to 20 feet;
delicate pink flowers in spring; smooth green bark; interesting bead-like fruit
Mexican plum* Prunus mexicana sun or part shade; grows up to 20 feet;
one of the first to flower in the spring;
beautiful white, fragrant flowers;
interesting flaky bark
Prairie flame-leaf sumac*
Rhus lanceolata prefers full sun; grows 10-20 feet; small white flowers in the summer; birds will love the red berries; brilliant red color in the fall; will spread to become several small trees, needs room to expand
Rusty blackhaw viburnum*
Viburnum rufidulum sun or shade; grows 10-20 feet; large white flower clusters in spring; red fall color
Smoketree Cotinus obovatus sun or part shade; grows 12-20 feet;
prefers dry soil; interesting flowers/fruit, looks like smoke; orange fall color
Texas redbud* Cercis canadensis var.
texensis sun or part shade; grows 20-30 feet; one of the first to flower in spring; beautiful pink flowers
Tall Shrubs Deciduous holly* Ilex decidua sun or part shade; grows 12-20 feet;
deciduous; striking red berries on females in fall that persist into winter
Dwarf wax myrtle Myrica pusilla sun or part shade; evergreen; grows 8-12 feet; golden yellow flowers; small blue fruits are eaten by many different birds
Evergreen sumac* Rhus virens prefers full sun; thick evergreen foliage, but will turn bronze after a freeze; grows 4-12 feet tall and 6-8 feet wide; red berries in late fall; does not like to be over watered
Golden-ball lead tree
Leucaena retusa sun or part shade; prefers dry soil and does not like to be over watered; grows up to 12 feet; flowers are yellow puffs in spring, summer, and fall
False indigo* Amorpha fruticosa plant this one where your soil stays wet;
grows up to 12 feet; beautiful dark purple tiny flowers in spring
Mexican buckeye* Ungnadia speciosa sun or shade; grows 12-20 feet tall and 12-20 feet wide; pink flowers in early spring; brilliant yellow fall color;
interesting seed pods are left behind after the leaves fall
Prickly ash*, toothache tree, or tickle-tongue
Zanthoxylum hirsutum sun or part shade; grows up to 15 feet;
interesting fragrant foliage; has many sharp spines (do not plant this one too near sidewalks); swallowtail butterfly larvae use this plant
Silktassel Garrya ovata var.
lindheimeri (Garrya lindheimeri) evergreen; full sun; prefers dry soil; grows 3-12 feet; silvery-grey leaves
Texas mock orange Philadelphus texensis sun or part shade; grows up to 12 feet;
white flowers in late spring and early summer
Texas mountain laurel*, or Mescal bean
Sophora secundiflora sun or part shade; evergreen; grows 10- 20 feet; beautiful fragrant purple flowers;
seeds are poisonous if eaten; be patient with this plant, it grows very slowly
Texas pistache (not Chinese pistache)
Pistacia texana (not Pistacia chinensis) sun; evergreen; grows 12-30 feet tall and 15-20 feet wide; prefers dry soil; leaves are small and glossy
Wafer-ash*, or hop tree
Ptelea trifoliata sun or shade; grows 3-12 feet; interesting fragrant foliage and fruit; swallowtail butterfly larvae use this plant
Wax myrtle Myrica cerifera sun or part shade; evergreen; grows up to 15 feet; golden yellow flowers; small blue fruits are eaten by many different birds
Witch hazel Hamamelis virginiana prefers shade, but can take sun; grows up to 30 feet; golden yellow fall color;
interesting yellow flowers in the late fall after the leaves drop
Low Shrubs Agarita*, or agarito, or algaritas
Berberis trifoliolata sun or shade; evergreen; spiny leaves (do not plant this one too near sidewalks);
grows 3-6 feet tall and 3-6 feet wide; one of the first to flower in the spring;
fragrant yellow flowers followed by small red berries
Black dalea* Dalea frutescens sun; grows 1-3 feet tall and 3-4 feet wide;
very small, delicate leaves; purple flowers in the summer and fall
Butterfly bush Buddleja marrubiifolia sun or part shade; semi-evergreen; grows 4-6 feet tall and 4-6 feet wide; silvery-grey leaves; orange flowers summer and fall that attract butterflies
Chili piquin Capsicum annuum prefers shade; grows 2-3 feet; small white flowers in summer and fall; small red fruits following the flowers attract birds
Flame acanthus Anisacanthus quadrifidus var.
wrightii full sun or part shade; grows 3-4 feet;
flowers are red or orange from summer to fall and attract hummingbirds and butterflies
Fragrant mimosa*, or pink mimosa
Mimosa borealis prefers sun; prefers dry soil; has many sharp hooked spines (do not plant this one too near sidewalks); grows 3-7 feet tall; many beautiful pink flowers in early spring
Gregg dalea Dalea greggii prefers full sun; grows up to 1 foot tall and 2-4 feet wide; works as a ground cover;
prefers dry soil; flowers summer and fall
Gregg sage, or cherry sage
Salvia greggii full sun; evergreen; grows up to 3 feet tall;
flowers range in color from red to pink to white; attracts hummingbirds; spring, summer, and fall
Mexican oregano Poliomentha longiflora prefers sun; evergreen; grows up to 3 feet tall and up to 3 feet wide; pink flowers spring, summer, and fall that attract hummingbirds
Mountain sage Salvia regla prefers part shade; grows 3-6 feet tall and 3-4 feet wide; plant this one where your soil stays damp; red flowers in the fall that attract hummingbirds
Shrubby blue sage, or mejorana
Salvia ballotiflora prefers sun; grows up to 6 feet tall;
flowers spring, summer, and fall;
fragrant (minty) leaves
Shrubby boneset*, fragrant white mistflower, or thorouthwort
Eupatorium havanense needs some shade; grows 3-5 feet tall and 3-5 feet wide; white flowers in the late summer and fall that attract butterflies
Skunkbush*, or aromatic sumac
Rhus trilobata (Rhus aromatica) sun or part shade; usually grows less than 3 feet tall, and 3-5 feet wide;
delicate small leaves; red berries in the fall; leaves turn brilliant red in the fall
Turk’s cap* Malvaviscus arboreus var. drummondii prefers shade; grows 2-6 feet tall and 3-5 feet wide; red flowers summer and fall that attract butterflies and hummingbirds
Yaupon holly Ilex vomitoria sun or shade; evergreen; grows 12-20 feet tall and 10-15 feet wide (dwarf varieties available that grow 2-4 feet tall and 2-4 feet wide); red berries on females
Vines Coral honeysuckle Lonicera sempervirens full sun; evergreen; elongate red flowers in early spring and some flowers in summer; attracts butterflies and hummingbirds
Crossvine Bignonia capreolata sun or part shade; evergreen; large orange flowers in the spring
Lindheimer’s morning glory
Ipomoea lindheimeri sun or part shade; delicate perennial;
large pale purple flowers
Purple leather flower*
Clematis pitcheri sun or part shade; delicate perennial;
purple flowers with leathery petals
Virginia creeper* Parthenocissus quinquefolia sun or part shade; interesting leaves; bird will eat the berries; bright red fall color
White bush honeysuckle*
Lonicera albiflora prefers sun; grows as a shrub or a vine;
small white flowers are quite fragrant;
attracts butterflies; red berries in summer
Xerophytes – plants that are adapted to especially dry soil conditions Texas sotol Dasylirion texanum sun; prefers dry soil; grows 3-4 feet across; interesting spiny foliage; very tall flower stalks
Devil’s shoestring* Nolina lindheimeriana sun; prefers dry soil; smaller clusters of leaves with tall flower stalks
Lechuguilla Agave lechuguilla sun; prefers very dry soil; interesting spiny foliage; very tall flower stalks;
spreads by offshoots and needs lots of room to expand
Red yucca Hesperaloe parviflora sun; prefers dry soil; red flowers on a tall stalk; attracts hummingbirds
Spanish dagger Yucca treculeana or Yucca torreyi sun; prefers dry soil; grows 3-12 feet tall;
leaves are stiff and spear-like (do not plant this one too near sidewalks); white flowers in spring
Texas sacahuista*, or basket grass
Nolina texana sun; prefers dry soil; large clusters of leaves, grows 3 feet across; white flowers hidden within leaves
Perennial Flowers Aromatic aster*, or fall aster Aster oblongifolius sun or part shade; grows 2-3 feet tall and
2-3 feet wide; purple flowers in the fall Big red sage Salvia penstemonoides sun or part shade; grows 3-4 feet tall and
1-2 feet wide; magenta flowers summer and fall that attract hummingbirds
Blackfoot daisy* Melampodium leucanthum full sun; prefers dry soil; grows up to 1 foot tall, and 1-2 feet wide; white flowers during spring, summer, and fall
Bushy skullcap* Scutellaria wrightii full sun; grows up to 1 foot tall and 1 foot wide; lots of small purple flowers spring, summer, and fall
Canyon sage Salvia lycioides flowers spring and fall Cedar sage* Salvia roemeriana needs shade; evergreen; grows 1-2 feet tall and 3 feet wide; red flowers in spring that attract hummingbirds
Chocolate daisy, or lyre-leaf green eyes
Berlandiera lyrata yellow daisy flowers from summer to fall
Damianita Chrysactinia mexicana prefers sun; grows 1-2 feet tall and 1-2 feet wide; yellow flowers; does well at dry sites
Engelmann daisy*, or cutleaf daisy
Engelmannia pinnatifida (Engelmannia peristenia) full sun; yellow flowers in spring and summer
Fall obedient plant, or false dragon-head
Physostegia virginiana shade or part sun; grows 2-4 feet tall and up to 2 feet wide; purple flowers in the fall
Gaura* Gaura lindheimeri sun or part shade; grows 2-4 feet tall and 3 feet wide; pink to white flowers spring and summer
Gayfeather* Liatris mucronata prefers sun; grows 1-2 feet tall; purple flowers in the fall
Giant blue sage* Salvia azurea full sun; grows 3-6 feet tall; delicate blue flowers
Goldenrod* Solidago canadensis (or S. nemoralis) full sun; grows 2-5 feet tall; abundant yellow flowers in the fall; prefers dry soil
Heath aster* Aster ericoides sun; grows 1-2 feet tall and up to 1 foot wide; numerous small white flowers in the fall
Hill Country penstemon, or Scarlet penstemon
Penstemon triflorus sun or part shade; prefers dry soil; grows 1-2 feet tall and 1-2 feet wide; pinkish-red flowers in spring and summer
Mealy sage* Salvia farinacea full sun; 1-3 feet tall and 1-2 feet wide;
prefers dry soil; purple flowers
Pigeonberry* Rivina humilis prefers shade; 1-2 feet tall and up to 2 feet wide; white flowers and bright red fruits from summer to fall
Pink skullcap Scutellaria suffretescens sun or part shade; each plant can spread to 2 feet wide; dark pink flowers spring, summer, and fall
Prairie larkspur* Delphinium carolinianum sun or part shade; white or blue flowers along 1-3 feet tall stalks
Prostrate lawnflower*, or horseherb
Calyptocarpus vialis part sun or shade; small yellow flowers spring, summer, and fall; a low-growing ground cover
Purple cone-flower* Echinacea angustifolia sun or part shade; grows 1-2 feet tall;
large purple flowers in the spring and summer that attract butterflies
Red columbine* Aquilegia canadensis needs shade; plant this one where your soil stays damp; grows 1-3 feet tall and 1-2 feet wide; interesting leaves;
beautiful red flowers that attract hummingbirds
Rock penstemon, or cut-leaf penstemon
Penstemon baccharifolius prefers dry soil; grows up to 2 feet tall;
large red flowers in spring, summer, and fall
Texas betony Stachys coccinea prefers shade; grows 1-2 feet tall and 2-3 feet wide; leaves are gray-green in color; red flowers in the spring, summer, and fall
Texas rock rose, or rose pavonia
Pavonia lasiopetala sun or part shade; grows 1-3 feet tall and 2-3 feet wide; pink flowers during the summer and fall that attract butterflies
Texas star hibiscus Hibiscus coccineus full sun; grows up to 4 feet tall and up to 4 feet wide; orange star-like flowers all summer and into the fall
Tropical sage* Salvia coccinea sun or shade; grows up to 3 feet tall, and 1-2 feet wide; red flowers in spring, summer, and fall that attract butterflies and hummingbirds
Wild fox-glove* Penstemon cobaea sun; prefers dry soil; grows 1-2 feet tall;
large white flowers in spring
Wood fern*, or river fern
Thelypteris kunthii prefers shade; plant this one where your soil stays damp; grows 2-5 feet tall and up to 3 feet wide
Woolly ironweed* Vernonia lindheimeri full sun; prefers dry soil; grows 1-2 feet tall; lots of small purple flowers in the summer
Ornamental (tall) grasses Big bluestem* Andropogon gerardii full sun or part shade; grows 3-5 feet tall and needs lots of room to spread;
flowers in the fall
Bull muhly Muhlenbergia emersleyi full sun or part shade; grows 3-5 feet tall;
flowers in the fall have a purplish color
Indian grass*, or yellow Indian grass
Sorghastrum nutans prefers full sun, can grow in part shade;
grows 3-5 feet tall and needs lots of room to spread; yellow fall color
Lindheimer’s muhly* or big muhly
Muhlenbergia lindheimeri a clump grass to use instead of Pampas grass; grows 3-5 feet tall and 3 feet wide; flowers in the fall
Little bluestem* Schizachyrium scoparium sun; grows 2-5 feet tall and needs lots of room to spread; leaves are blue-green in color and the flower stalks turn bronze after the first frost
Mexican feather grass
Stipa tenuissima sun to part shade; grows 1-2 feet tall;
leaves are thin and bright green; flowers in late summer
Pine muhly Muhlenbergia dubia prefers full sun; prefers dry soil; grows 1- 2 feet tall; leaves are gray-green in color
Turf grasses Buffalo grass* Buchloe dactyloides prefers sun; grows very short and needs very little mowing; needs very…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .