W90VN924R0004.pdf

PDF 2 MB Posted

Attached to
MA IDIQ Contract for Minor General Building Repair and Construction, Area IV
Solicitation number
W90VN924R0004
Issued by

About this file

This is a solicitation for an indefinite delivery indefinite quantity (IDIQ) multiple award task order contract to provide minor general building repair and construction services for United States Army Garrison Daegu facilities in Area IV, Korea. The solicitation requires contractors to provide all labor, materials, equipment, and other resources necessary to perform repair and construction tasks identified on individual task orders. The contract type is firm-fixed-price and task orders will be issued by the 411th Contracting Support Brigade. The maximum potential combined ceiling amount under each IDIQ contract is $4,000,000 per year and $20,000,000 for the five-year contract period. Task orders will be limited to $250,000 or less and a higher tier MA IDIQ contract will be used for requirements exceeding that amount.

View the file

Other files

File Type Posted
Attachment 1-Bidding Schedule (Rev3).xlsx XLSX spreadsheet
W90VN924R0004-0003.pdf PDF
Attachment 1-Bidding Schedule (Rev2).xlsx XLSX spreadsheet
W90VN924R0004-0002.pdf PDF
Attachment 1-Revised Bidding Schedule.xlsx XLSX spreadsheet
W90VN924R0004-0001.pdf PDF
Attachment 1-Bidding Schedule.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0012007614

Magnitude of Repair/Construction: Maximum capacity of $20,000,000 for the entire f ive-year ordering period and individual task orders shall be Firm-Fixed Price and w ill not exceed $250,000.

This IDIQ w ill be used for simple and small w ork for the task order limitation of $250,000. MA IDIQ Contract, Repair and Upgrade of USFK facilities for Area IV w ill be used for the high dollar amount that requires design. Design/Draw ings w ill be provided for the high dollar requirement.

Question shall be emailed to chonghyon.kw on.ln@army.mil and bumjoon.j.pak.civ@army.mil

MS. KWON, CHONG-HYON 315-763-5693

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

NEGOTIATED

15-Nov-2023

(RFP)

(IFB)

X

CALL:

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS

MA IDIQ Contract for Minor General Building Repair and Construction, Area IV.

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

See Item 7

2. TYPE OF SOLICITATION

SEALED BID

3. DATE ISSUED

9. FOR INFORMATION A. NAME

SOLICITATION

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

11. The Contractor shall begin performance w ithin _______10 calendar days and complete it w ithin ________ calendar days after receiving aw ard, X notice to proceed. This performance period is X mandatory, negotiable. (See _________________________

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

YES X NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and __________ copies to perform the w ork required are due at the place specif ied in Item 8 by ___________ local time ______________29 Dec 2023 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.

shall be marked to show the offeror's name and address, the solicitation number, and the date and time of fers are due.

B. An offer guarantee is, X is not required.

C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than _______180 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

7. ISSUED BY CODE

411TH CONTRACTING SUPPORT BRIGADE, KOREA

RCO DAEGU, UNIT #15682

APO AP 96218-5682

UNITED STATES

W90VN9

PAGE OF PAGES

CODE

(Title, identifying no., date):

12B. CALENDAR DAYS

01:00 PM (hour)

Sealed envelopes containing offers

5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

NA

8. ADDRESS OFFER TO (If Other Than Item 7)

FAX:TEL: TEL: FAX:

W90VN924R0004 1 OF 132

20B. SIGNATURE

(REV. 4-85)STANDARD FORM 1442 BACK

TO SIGN

NSN 7540-01-155-3212

SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)

CODE FACILITY CODE

17. The offeror agrees to perform the w ork required at the prices specif ied below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.

the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS SEE SCHEDULE OF PRICES

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN

OFFER (Type or print)

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM

(4 copies unless otherwise specified)

CODE

(Insert any number equal to or greater than

20C. OFFER DATE

25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) 41 U.S.C. 253(c)

CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY

(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)

See Item 14

(Include only if different than Item 14)16. REMITTANCE ADDRESS

30B. SIGNATURE

29. AWARD (Contractor is not required to sign this document.)

document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .

gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)

30C. DATE

(Type or print)

TEL: EMAIL:

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

(Contractor is required to sign this28. NEGOTIATED AGREEMENT

(M ust be fully completed by offeror)OFFER

W90VN924R0004

Section B - Supplies or Services and Prices

GENERAL DESCRIPTION

B-1. DESCRIPTION

a. The Contractor shall provide all labor, tools, materials, transportation, equipment, supplies, and other necessary resources for General Building Repair and Construction, USAG Daegu, Area IV, in accordance with the Statement of Work (SOW), specifications, drawings and terms and conditions contained herein.

b. The statement of work (SOW) in this section broadly defines repair and construction of general buildings and exterior site. Each individual task order shall be issued which specifically defines the scope of work to be performed herein. Pricing for the work to be performed shall be taken from the Sub-CLINs associated with each line item that are incorporated into the contract.

B-2. CONTRACT TYPE: This is a Multiple Award Indefinite Delivery Indefinite Quantity (MA IDIQ) Firm Fixed Price (FFP) Task Order Contract. All supplies/services will be obtained by individual task orders issued by the Contracting Officer, 411th Contracting Support Brigade (CSB).

B-3. MINIMUM GUARANTEE/MAXIMUM POTENTIAL COMBINED CEILING AMOUNT

a. This IDIQ will be used for simple and small work that listed in the Attachment 1-Bidding Schedule. MA IDIQ Contract, Repair and Upgrade of USFK facilities for Area IV will be used for the high dollar amount, which exceed $250,000 that requires design. Design/drawings will be provided for the high dollar requirement.

b. If the Government determines to make multiple awards, each IDIQ contract award will have a minimum guarantee of $3,000 for base period only regardless of the number of awards. The maximum potential combined ceiling amount under each IDIQ contract will not exceed $4,000,000 for each year. The total of all contracts awarded will not exceed the ceiling amount of $20,000,000 during the five years (base plus four option years).

c. The minimum guarantee for the total IDIQ is provided in the amount of $3,000 and shall be obligated by issuance of a task order during the base period. The guarantee/limitations by year will be equivalent to the Contract Korean Won Rate for the following dollar amounts.

Period Minimum Guarantee Maximum Potential Combined Ceiling Amount

Base Period $3,000.00 $4,000,000.00

Option Period 1 $0.00 $4,000,000.00

Option Period 2 $0.00 $4,000,000.00

Option Period 3 $0.00 $4,000,000.00

Option Period 4 $0.00 $4,000,000.00

d. The maximum potential combined ceiling amount in the resulting contract is not the actual contract amount. The maximum potential combined ceiling amount is the ceiling amount for the total price of task orders that the Government will issue in a given contract period, not to exceed the stated maximum amount in B-3.

ITEM NO SUPPLIES/SERVICES MAX

QUANTITY

UNIT UNIT PRICE MAX AMOUNT

0001 50 Job Base Period

FFP

The contractor shall provide all necessary resources to perform minor general building repair and construction, USAG Daegu, Area IV, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. *** Unit price shall include total amounts covering all line items for Base Period outlined in Attachment 1 in Section J *** FOB: Destination

PURCHASE REQUEST NUMBER: 0012007614

PSC CD: Z1AZ

MAX

NET AMT

UNIT UNIT PRICE MAX AMOUNT

0002 50 Job Estimated cost for War Hazard Losses

FFP

is zero (0).

FOB: Destination

UNIT UNIT PRICE MAX AMOUNT

1001 50 Job OPTION Option Period 1

FFP

The contractor shall provide all necessary resources to perform minor general building repair and construction, USAG Daegu, Area IV, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. *** Unit price shall include total amounts covering all line items for Option Period 1 outlined in Attachment 1 in Section J ***

UNIT UNIT PRICE MAX AMOUNT

1002 50 Job OPTION Estimated cost for War Hazard Losses

FFP

is zero (0).

UNIT UNIT PRICE MAX AMOUNT

2001 50 Job OPTION Option Period 2

FFP

The contractor shall provide all necessary resources to perform minor general building repair and construction, USAG Daegu, Area IV, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. *** Unit price shall include total amounts covering all line items for Option Period 2 outlined in Attachment 1 in Section J ***

UNIT UNIT PRICE MAX AMOUNT

2002 50 Job OPTION Estimated cost for War Hazard Losses

FFP

is zero (0).

UNIT UNIT PRICE MAX AMOUNT

3001 50 Job OPTION Option Period 3

FFP

The contractor shall provide all necessary resources to perform minor general building repair and construction, USAG Daegu, Area IV, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. *** Unit price shall include total amounts covering all line items for Option Period 3 outlined in Attachment 1 in Section J ***

UNIT UNIT PRICE MAX AMOUNT

3002 50 Job OPTION Estimated cost for War Hazard Losses

FFP

is zero (0).

UNIT UNIT PRICE MAX AMOUNT

4001 50 Job OPTION Option Period 4

FFP

The contractor shall provide all necessary resources to perform minor general building repair and construction, USAG Daegu, Area IV, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. *** Unit price shall include total amounts covering all line items for Option Period 4 outlined in Attachment 1 in Section J ***

UNIT UNIT PRICE MAX AMOUNT

4002 50 Job OPTION Estimated cost for War Hazard Losses

FFP

is zero (0).

Section C - Descriptions and Specifications

TECHNICAL PROVISIONS - I

STATEMENT OF WORK

PROJECT NO. TITLE LOCATION

N/A IDIQ Contract for Minor General Building Repair and Construction USAG Daegu

1. DESCRIPTION: The work to be performed for completion of this project shall be in general as described below and executed by one or more of the groups.

a. Work by Contractor: The contractor shall provide all labor, tools, equipment, supplies and any other resources necessary to accomplish the scope of work contained herein as listed on the bidding schedule for all US forces installations in Area IV in accordance with the drawings and specifications.

b. Work by In-House Forces: Not applicable to this project.

c. Work by Troop Labor: Not applicable to this project.

2. PRINCIPAL FEATURES: This project includes the following principal features:

a. Perform the following various repair of general building and related requirement works as listed on the bidding schedule.

b. The quantity in the bidding schedule does not mean the minimum guaranteed quantity to be requested per task order.

Architectural Work

1. Remove Exterior Insulation and Finish System incl. metal lath EPS board etc. on existing wall.

2. Remove partition wall incl. frames.

3. Remove gypsum wall board.

4. Remove CMU or brick wall.

5. Remove vinyl cove base, 100mm-150mm high.

6. Remove wood base board, 100mm high x 25mm thick.

7. Remove wood chair rail, 100mm-150mm high.

8. Remove wallpaper and lining paper.

9. Remove existing metal lath with cement plaster and glazed ceramic wall tiles.

10. Remove corrugated or protected ribbed sheet metal siding.

11. Remove insulation on the wall or ceiling system, 100mm to 200mm thick.

12. Replace Exterior Insulation and Finish System (Drainable type) incl. EPS board etc. on concrete or CMU wall.

13. Replace Exterior Insulation and Finish System (Non-Drainable type) incl. EPS board etc. on metal or wood surface.

14. Replace concrete masonry unit, 390mm X 190mm X 150mm w/re-bars & W.W.F.

15. Replace concrete masonry unit, 390mm X 190mm X 190mm w/re-bars & W.W.F.

16. Replace metal stud/runner for wall, 50mm wide, 400mm O.C.

17. Replace metal stud/runner for wall, 100mm wide, 400mm O.C.

18. Replace metal stud/runner for wall, 150mm wide, 400mm O.C.

19. Replace metal casing bead.

20. Replace metal lath with cement plaster, 25mm thick.

21. Replace cement mortar, waterproofing.

22. Replace glazed ceramic wall tile incl. accessories (trim & corner).

23. Replace insulation with aluminum foil jacket, 50mm thick.

24. Replace insulation with aluminum foil jacket, 100mm thick.

25. Replace wall board with 15mm thick gypsum board incl. joint taping & compound, regular type.

26. Replace wall board with 15mm thick gypsum board, incl. joint taping & compound, water resistant type.

27. Replace vinyl cove base, 100mm-150mm high.

28. Replace wood base board, 100mm high x 25mm thick.

29. Replace wood chair rail, 15T, 100 - 150mm high, oak molding.

30. * Replace wallpaper (ASTM E 84, Class A).

31. * Replace soundproof wall, 50mm thick, fire rated.

32. Replace #24 gauge. corrugated or protected ribbed type sheet metal siding incl. painting.

33. Replace #16 gauge. PVC coated chicken wire.

34. Install Exterior Insulation and Finish System (Drainable type) incl. EPS board etc. on concrete or CMU wall.

35. Install Exterior Insulation and Finish System (Non-Drainable type) incl. EPS board etc. on metal or wood surface.

36. Install concrete masonry unit, 390mm X 190mm X 150mm w/re-bars & W.W.F.

37. Install concrete masonry unit, 390mm X 190mm X 190mm w/re-bars & W.W.F.

38. Install metal stud/runner for wall, 50 mm wide, at 400 mm O.C.

39. Install metal stud/runner for wall, 100 mm wide, at 400 mm O.C.

40. Install metal stud/runner for wall, 150 mm wide, at 400 mm O.C.

41. Install metal casing bead.

42. Install metal lath with cement plaster, 25mm thick.

43. Install cement mortar, waterproofing.

44. Install glazed ceramic wall tile incl. accessories (trim & corner).

45. Install insulation with aluminum foil jacket, 50mm thick.

46. Install insulation with aluminum foil jacket, 100mm thick.

47. Install wall board with 15mm thick gypsum board incl. joint taping & compound, regular type.

48. Install wall board with 15mm thick gypsum board, incl. joint taping & compound, water resistant type.

49. Install vinyl cove base, 100mm-150mm high.

50. Install wood base board, 100mm high x 25mm thick.

51. Install wood chair rail, 15T, 100 - 150mm high, oak molding.

52. * Install wallpaper (ASTM E 84, Class A).

53. * Install soundproof wall, 50mm thick, fire rated.

54. Install #24 gauge. corrugated or protected ribbed type sheet metal siding incl. painting.

55. Drill holes on concrete wall or floor (100mm to 200 thick), up to 100mm dia.

56. Install #16 gauge. PVC coated chicken wire.

57. Remove gypsum ceiling board with suspended ceiling system incl. aluminum ceiling access door.

58. Remove gypsum ceiling board.

59. Remove acoustical ceiling tile with suspended ceiling system.

60. Remove acoustical ceiling tile.

61. Remove insulation on the ceiling system, 100mm - 200mm. SM.

62. Remove and reinstall acoustical ceiling tile.

63. Replace acoustical ceiling tile, 15mm thick.

64. Replace acoustical ceiling tile, 19mm thick.

65. * Replace acoustical ceiling tile, 15mm thick, humidity resistant type.

66. * Replace suspended ceiling system w/accessories for acoustical tile, 15mm thick.

67. * Replace suspended ceiling system w/accessories for acoustical tile, 19mm thick.

68. Replace suspended ceiling system w/accessories for gypsum board.

69. Replace ceiling board with 12.5mm thick gypsum board incl. joint taping & compound.

70. Replace ceiling board with 12.5mm thick gypsum board (water resistant type) incl. joint taping & compound.

71. Replace aluminum ceiling access door w/metal frame, 450mm x 450mm.

72. Replace aluminum ceiling access door w/metal frame, 600mm X 600mm.

73. Replace insulation with aluminum foil jacket, 200mm thick on ceiling system.

74. Install acoustical ceiling tile, 15mm thick.

75. Install acoustical ceiling tile, 19mm thick.

76. * Install acoustical ceiling tile, 15mm thick, humidity resistant type.

77. * Install suspended ceiling system w/accessories for acoustical tile, 15mm thick.

78. * Install suspended ceiling system w/accessories for acoustical tile, 19mm thick.

79. Install suspended ceiling system w/accessories for gypsum board (12.5mm).

80. Install suspended ceiling system w/accessories for gypsum board (12.5mm, Water resistant type).

81. Install ceiling board with 12.5mm thick gypsum board incl. joint taping & compound.

82. Install ceiling board with 12.5mm thick gypsum board (water resistant type) incl. joint taping & compound.

83. Install aluminum ceiling access door w/metal frame, 450mm x 450mm.

84. Install aluminum ceiling access door w/metal frame, 600mm X 600mm.

85. Install insulation with aluminum foil jacket, 200mm thick on ceiling system.

86. Remove silicon sealants and caulking.

87. Replace caulking for painting area.

88. Painting preparation for Concrete, CMU, and Mortar plaster surface.

89. Painting preparation for gypsum board surface (Joint putty).

90. Painting preparation for gypsum board surface (All putty).

91. Painting preparation for wood surface.

92. Painting preparation for metal surface.

93. Install caulking for painting area.

94. Paint, alkyd or oil for wood primer, 1 coat.

95. Paint, alkyd anti-corrosive metal primer.

96. Paint, interior, latex, 2 coats.

97. Paint, exterior, latex, 2 coats.

98. Paint, alkyd enamel 2 coats.

99. Paint on concrete floor, epoxy paint, 2 coats.

100. Paint, Texture (Texture 1 coat, spray + clear 1 coat, roller).

101. Paint, roof coating for Korean roof tile, 2 coats.

102. Paint, varnish, interior oil modified clear urethane, stain, 2 coats.

103. Paint for exterior insulation and finish system.

104. Install and remove vinyl tape for painting area (door, window, base board and etc.).

105. Excavate including backfill compaction and removal.

106. Grinder concrete floor for epoxy paint or urethane, 3mm thick.

107. Chip-off existing concrete floor, 50mm avg. depth & provide 50mm concrete topping finish.

108. Remove carpet or carpet tile with glue and felt.

109. Remove vinyl composition floor tile.

110. Remove 15mm thick plywood (water resistant type) underlayment.

111. Remove non reinforced concrete.

112. Remove reinforced concrete.

113. Replace 38mm dia max. gravel / sand for capillary water barrier.

114. Replace expansion/construction joint filler up to 120mm thick and sealant finish.

115. Replace carpet with level-loop, multilevel loop or cut incl. accessories, fire retardant type.

116. Replace ceramic floor tile.

117. Replace quarry floor tile.

118. Replace vinyl composition tile, 300mm x 300mm x 3mm thick.

119. Replace vinyl composition tile, 450mm x 450mm x 3mm thick.

120. Replace 100 mm thk. concrete floor slab with WWF, exp. Joint & V/B.

121. Replace 150 mm thk. concrete floor slab with WWF, exp. Joint & V/B.

122. Replace concrete stoop inc. WWF, NFSM, & expansion joint.

123. Replace 15mm thick plywood (water resistant type) underlayment.

124. Install 38mm dia max. gravel / sand for capillary water barrier.

125. Install expansion/construction joint filler up to 120mm thick and sealant finish.

126. Install carpet with level-loop, multilevel loop or cut incl. accessories, fire retardant type.

127. Install ceramic floor tile.

128. Install quarry floor tile.

129. Install vinyl composition tile, 450mm x 450mm x 3mm thick.

130. Install 150 mm thk. concrete floor slab with WWF(#6-150x150), exp. Joint & V/B.

131. Install concrete stoop inc. WWF(#6-150x150), NFSM, & expansion joint.

132. Install 15mm thick plywood (water resistant type) underlayment.

133. Fabricate, install & remove concrete plywood form

134. Fabricate, install & remove concrete euro form.

135. Remove all type of single steel or wood or aluminum door with frame incl. all accessories.

136. Remove all type of double steel or wood or aluminum door with frame incl. all accessories.

137. Remove rolling service door, frame, operated motors incl. accessories.

138. Remove and reinstall electronic mortise lock.

139. Replace steel flush single door with steel door frame, 900mm X 2,150mm, 45mm thick.

140. Replace steel flush double door with steel door frame, 1,800mm X 2,150mm, 45mm thick.

141. * Replace wood flush solid core single door with steel door frame, 900mm X 2,150mm, 45mm thick.

142. * Replace wood flush solid core double door with steel door frame, 1,800 mm X 2,150 mm, 45 mm thick.

143. * Replace wood hollow core single door with wood door frame, 900 mm X 2,100 mm X 45 mm thick.

144. Replace 45-minute fire rated steel flush insulated single door with steel door frame, 900mm X 2,150mm, 44.5mm thick.

145. * Replace 45-minute fire rated wood flush insulated single door with steel door frame, 900mm X 2,150mm,

146. Replace rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening up to 14.44 SM).

147. Replace rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening from 14.44 to 18.49 SM).

148. Replace rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening from 18.49 to 23.04 SM).

149. Replace rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening from 23.04 to 33 SM).

150. Replace rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening from 33.0 to 42.25 SM).

151. Replace rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening from 42.25 to 60 SM).

152. Replace metal louver and frame.

153. Replace 6.75mm thick laminated glass for door or window.

154. * Replace electronic mortise lock.

155. Replace master key system (key and core only).

156. * Replace exit device, type 3 or 10, F-05/08.

157. * Replace exit device, type 2, F-01.

158. * Replace mortise lockset, F-02, F-04, F-05, F-07, F-08 or F-13.

159. Replace bored type lockset, F-82 or F-86.

160. Replace hinge butt, 4-1/2" x 4-1/2", A2111 or A5111.

161. Replace hinge butt, 4-1/2" x 4-1/2", A8111.

162. *Replace aluminum weather strips for door (Head & Jamb, Astragal, ANSI/BHMA. R3E734/R3E735 type).

163. *Replace aluminum weather strips for door (Door sweep, ANSI/BHMA.R5G165 type).

164. Replace wood trim, 25 mm X 50 mm.

165. * Replace aluminum thresholds, 100mm to 150mm wide.

166. Replace door stopper and holder, L01361, L01371, L02141, L01381, L02121, L01241 & etc.

167. Replace door closer, C02021, C02011.

168. Replace push plate, J304.

169. Replace pull plate, J407.

170. Replace kick plate, J102.

171. Install steel flush single door with steel door frame, 900mm X 2,150mm, 44.5mm thick.

172. Install steel flush double door with steel door frame, 1,800mm X 2,150mm, 44.5mm thick.

173. * Install wood flush solid core single door with steel door frame, 900mm X 2,150mm, 45mm thick.

174. * Install wood flush solid core double door with steel door frame, 1,800 mm X 2,150 mm, 45 mm thick.

175. * Install wood hollow core single door with wood door frame, 900 mm X 2,100 mm X 45 mm thk.

176. Install 45-minute fire rated steel flush insulated single door with steel door frame, 900mm X 2,150mm,

177. * Install 45-minute fire rated wood flush insulated single door with steel door frame, 900mm X 2,150mm,

178. Install rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening up to 14.44 SM).

179. Install rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening from 14.44 to 18.49 SM).

180. Install rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max

181. Install rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening from 23.04 to 33 SM).

182. Install rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max opening from 33 to 42.25 SM).

183. Install rolling service door, motor operated with safety laser sensor and all necessary accessories. (Max

184. * Install electronic mortise lock.

185. Install master key system (key and core only).

186. * Install exit device, type 3 or 10, F-05/08.

187. * Install exit device, type 2, F-01.

188. * Install mortise lockset, F-02, F-04, F-05, F-07, F-08 or F-13.

189. Install bored type lockset, F-82 or F-86.

190. Install hinge butt, 4-1/2" x 4-1/2", A2111 or A5111.

191. Install hinge butt, 4-1/2" x 4-1/2", A8111.

192. *Install aluminum weather strips for door (Head & Jamb, Astragal, ANSI/BHMA. R3E734/R3E735 type).

193. *Install aluminum weather strips for door (Door sweep, ANSI/BHMA.R5G165 type).

194. Install wood trim, 25 mm X 50 mm.

195. * Install aluminum thresholds, 100mm to 150mm wide.

196. Install door stopper and holder, L01361, L01371, L02141, L01381, L02121, L01241 & etc.

197. Install door closer, C02021, C02011.

198. Install push plate, J304.

199. Install pull plate, J407.

200. Install kick plate, J102.

201. Remove all type aluminum window w/frame, trim, insect screen etc.

202. Remove blind, vertical, or venetian type.

203. Remove window security bar.

204. Replace aluminum sliding window & aluminum frame, minimum AT/FP blast window (9.52mm clear laminated glass + 12mm air space + 6mm tinted low-e tempered glass) incl. insect screen & window latch.

205. Replace dual action aluminum window (Turn and tilt) & aluminum frame incl. accessories.

206. Replace #24 ga. 150 mm wide sheet metal flashing for window.

207. Replace horizontal blind.

208. Replace aluminum framed insect screen door or window.

209. Replace window security bar.

210. Install aluminum sliding window & aluminum frame, minimum AT/FP blast window (9.52mm clear laminated glass + 12mm air space + 6mm tinted low-e tempered glass) incl. insect screen & window latch.

211. Install horizontal blind.

212. Install aluminum framed insect screen door or window.

213. Install window security bar.

214. Remove toilet accessories (towel bar, mirror, soap dish and toilet paper dispenser and etc.).

215. Remove Lavatory Bowl incl. all accessories with Cabinet including drainage system etc.

216. Replace metal toilet partition with door incl. all accessories.

217. Replace metal toilet partition with door incl. all accessories, ADA type.

218. * Replace ADA toilet grab bar, 18# gauge. SST, Satin finish or peened finish (18"_vertical, 36" 42") 3EA.

219. Replace metal urinal partition incl. all accessories.

220. Replace stainless steel (SST) shower curtain rod, w/curtain, 25mm dia.

221. Replace SST robe hook.

222. Replace soap dish (stainless or ceramic).

223. Replace liquid soap dispenser.

224. Replace metal framed glass mirror, 450mm x 600mm high.

225. Replace metal framed tilting glass mirror, 600mm x 900mm high. for handicapped.

226. Replace SST toilet tissue dispenser.

227. Replace SST paper towel dispenser.

228. Replace #20-gauge heavy duty SST shelf incl. brackets & supports.

229. Replace SST towel bar.

230. Replace lavatory bowl incl. faucet, pop-up drain, trap and vanity cabinet, 700 mm W x 490 mm D x 760 mm H w/marble top.

231. Replace medicine cabinet, 470 mm x 870 mm H.

232. Replace waterproofing, cement mortar.

233. Replace caulking for bathroom, kitchen etc.

234. Install metal toilet partition with door incl. all accessories.

235. Install metal toilet partition with door incl. all accessories, ADA type.

236. * Install ADA toilet grab bar, 18# gauge. SST, Satin finish or peened finish (18"_vertical, 36" 42") 3EA.

237. Install metal urinal partition incl. all accessories.

238. Install stainless steel (SST) shower curtain rod, w/curtain, 25mm dia.

239. Install SST robe hook.

240. Install soap dish (stainless or ceramic).

241. Install liquid soap dispenser.

242. Install metal framed glass mirror, 450mm x 600mm high.

243. Install metal framed tilting glass mirror, 600mm x 900mm high. for handicapped.

244. Install SST toilet tissue dispenser.

245. Install SST paper towel dispenser.

246. Install #20-gauge heavy duty SST shelf incl. brackets & supports.

247. Install SST towel bar.

248. Install lavatory bowl incl. faucet, pop-up drain, trap and vanity cabinet, 700 mm W x 490 mm D x 760 mm H w/marble top.

249. Install medicine cabinet, 470 mm x 870 mm H.

250. Install caulking for bathroom, kitchen etc.

251. Remove 2"THK. polyurethane foams.

252. Remove wood truss with hardware.

253. Remove 1 ply- plywood sheathing.

254. Remove asphalt shingle roof with waterproofing sheet or asphalt felt.

255. Remove wood fascia board or soffit board with nailed.

256. Remove metal fascia board or soffit board with nailed.

257. Remove mineral fiber blanket insulation or rigid insulation in wall, ceiling and roof deck, 100~200mm.

258. Remove Korean cement roof tile with 1 ply rubberized, waterproofing membrane sheet underlayment & treated battens.

259. Remove #24 gauge galvanized, corrugated or protective metal roof.

260. Remove EPDM roofing with base sheet.

261. Remove #24-gauge galvanized sheet metal flashing incl. painting for valley, drip edge, window, door, smokestack, duct, eaves ventilation flashing etc.

262. Remove metal gutter or downspout with strap and hanger.

263. Replace 1 ply plywood sheathing (12mm thick, water-resistant type).

264. Replace 1 ply plywood sheathing (15mm thick, water-resistant type).

265. Replace wooden truss with hardware.

266. Replace wood fascia board & nailed, 250mm high x 25mm thick.

267. Replace wood soffit board, trim & nailed with 12mm thick plywood.

268. Replace pre-cast concrete splash block.

269. Replace Apply acrylic fluid applied waterproofing system on existing roof (Concrete/asphalt built up/wood/foamed/shingle/roll roofs).

270. Replace Apply acrylic fluid applied waterproofing system on existing metal roofs (Ribbed/Corrugated).

271. Replace asphalt shingle roofing with 1-ply rubberized waterproofing membrane sheet.

272. Replace cement roof tile, Spanish "S" type with 1-ply rubberized, waterproofing membrane sheet underlayment and wood strip.

273. Replace Korean cement roof tile, factory color finish, size: 12 mm x 400 mm x 350mm with 1-ply rubberized, waterproofing membrane sheet underlayment & treated battens.

274. Replace #24-gauge galvanized, corrugated or protective metal roof incl. painting.

275. Replace #24-gauge 150mm-200mm wide sheet metal rain gutter & hanger incl. painting.

276. Replace #24-gauge 100mm-150mm dia. sheet metal downspout & strap incl. painting.

277. Replace basket strainer, 100mm-150mm dia.

278. Replace #24-gauge galvanized sheet metal flashing incl. painting for valley flashing, drip edge, window, door, corner, smokestack, duct, eaves ventilation flashing etc.

279. Install 1 ply plywood sheathing (12mm thick, water-resistant type).

280. Install wooden truss with hardware.

281. Install wood fascia board & nailed, 250mm high x 25mm thick.

282. Install wood soffit board, trim & nailed with 12mm thick plywood.

283. Install pre-cast concrete splash block.

284. Apply acrylic fluid applied waterproofing system on existing roof (Concrete / asphalt built up / wood / foamed / shingle / roll roofs).

285. Apply acrylic fluid applied waterproofing system on existing metal roofs (Ribbed/Corrugated).

286. Install asphalt shingle roofing with 1-ply rubberized waterproofing membrane sheet.

287. Install Korean cement roof tile, factory color finish, size: 12 mm x 400 mm x 350mm with 1-ply rubberized, waterproofing membrane sheet underlayment & treated battens.

288. Install #24-gauge galvanized, corrugated or protective metal roof incl. painting.

289. Install #24-gauge 150mm-200mm wide sheet metal rain gutter & hanger incl. painting.

290. Install #24-gauge 100mm-150mm dia. sheet metal downspout & strap incl. painting.

291. Install basket strainer, 100mm-150mm dia.

292. Install #24-gauge galvanized sheet metal flashing incl. painting for valley, drip edge, window, door, smokestack, duct, eaves ventilation flashing etc.

293. Remove kitchen wall or base cabinet w/door & countertops and kitchen accessories.

294. Replace kitchen wall cabinet w/door (High Pressure Laminate Finish), 900mm W x 700mm H X 300mm D incl. self-closing cabinet hinges, wire pulls 100mmL and all necessary accessories.

295. Replace kitchen base sink cabinet with door (Laminate Finish), 900mm W x 920mm H x 650mm D, incl. all necessary accessories.

296. Replace kitchen base cabinet with 2 drawers and 2 doors (Laminate Finish), 900mm W x 920mm H x 650mm D, incl. all necessary accessories.

297. Replace kitchen hood cabinet (Laminate Finish) incl. all necessary accessories.

298. Replace kitchen countertop, artificial marble with back splash.

299. Install kitchen wall cabinet w/door (High Pressure Laminate Finish), 900mm W x 700mm H X 300mm D incl.

self-closing cabinet hinges, wire pulls 100mmL and all necessary accessories.

300. Install kitchen base sink cabinet with door (Laminate Finish), 900mm W x 920mm H x 650mm D, incl. all

301. Install kitchen base cabinet with 2 drawers and 2 doors (Laminate Finish), 900mm W x 920mm H x 650mm D, incl. all necessary accessories.

302. Install kitchen hood cabinet (Laminate Finish) incl. all necessary accessories.

303. Install kitchen countertop, artificial marble with back splash.

304. Replace interior identification sign 150mm x 225mm (service symbol).

305. Install interior identification sign 150mm x 225mm (service symbol).

306. Replace rubber stair tread with integrated riser, 480mm wide x 5mm thick.

307. Install rubber stair tread with integrated riser, 480mm wide x 5mm thick.

308. Install and remove scaffolding (double, 3 months rental) with temporary stair or slope and other scaffolding accessories.

309. Install and remove scaffolding (double, 6 months rental) with temporary stair or slope and other scaffolding

310. Install and remove scaffolding (single, 3 months rental) with temporary stair or slope and other scaffolding

311. Remove steel structure and related to all parts.

312. Remove wooden structure and related to all parts.

313. Remove and reinstall various furniture incl. steel or wooden cabinets, shelves, bookcases, office furniture, chairs, other office equipment and appliance.

314. Disassemble and reassemble office workstation.

315. Remove and dispose all construction debris.

316. Fabricate, Install & remove plywood form for concrete incl. all other supporting form accessories.

317. Replace steel structure, 1KG.

318. Replace wooden fence (3-horizontal brace(2"x4") with vertical boards (1"x6", Max H=1800mm) staggered on both sides, pressure-treated wood) include wooden post(4"x4") with concrete footing (Max @3000mm) and

319. Place ready mixed concrete, Class-A included surface finish and vibrator.

320. Provide plastic sheet at wall or floor for working area.

321. Install steel structure, 1KG.

322. Fabricate and install deformed reinforce steel bars.

323. Install wooden fence (3-horizontal brace(2"x4") with vertical boards (1"x6", Max H=1800mm) staggered on both sides, pressure-treated wood) include wooden post(4"x4") with concrete footing (Max @3000mm) and necessary accessories.

Mechanical Work

1. Remove all type sensor (temperature, humidity & other detectors).

2. Remove air handling unit, all type, cooling/heating coil, capacity: any size.

3. Remove air cooled condensing unit, any size.

4. Remove Package Air Conditioning Unit (Heat Pump or Elec. Heating Coil).

5. Remove hot water heating boiler or domestic hot water heater, capacity: any size.

6. Remove expansion tank, bladder or diaphragm type, capacity: any size.

7. Remove unit heater, horizontal or vertical type, any capacity.

8. Remove finned tube radiator with non-electric control valve, any capacity, fan coil unit, floor mounted or ceiling mounted type, any size.

9. Remove Smokestack w/ Barometric Damper, Any Size.

10. Remove pump, base mounted end suction or in-line type, capacity: 15 HP.

11. Remove All Type Valve, Fitting.

12. Remove Black Steel Pipe or Copper Tube including Fittings & Pipe Support.

13. Remove Pipe Insulation, Flexible Cellular or Glass Wool.

14. Remove roof or wall ventilator, any type/capacity.

15. Remove bathroom exhaust fan with grille & backdraft damper.

16. Remove Duct Accessories (Grille, Louver, Smoke Damper, Smoke Louver, Fire Damper, Volume Damper or Turning Vane).

17. Remove Air Duct.

18. Remove Duct Insulation, Flexible Cellular or Glass Wool.

19. Remove Galvanized Steel Vent Pipe with Fittings & Support, 30m.

20. Remove cast iron pipe, any size.

21. Remove Water Closet & Accessories.

22. Remove Urinal & Accessories.

23. Remove Lavatory & Accessories.

24. Remove Shower, Wall Mounted, single Lever, Head.

25. Remove bathtub w/ faucet.

26. Remove and re-install Plumbing Fixtures (Water Closet, urinal, Lavatory, Etc.).

27. Remove and re-install air conditioning unit or heat pump unit, up to 55,000 BTU/H including recharging freon gas, check, and operation test.

28. Remove and re-install fan-coil unit, Unit heater, boiler and window or finned tub heating radiator or convector.

29. Remove and reinstall kitchen range hood w/ wet chemical fire suppression system.

30. Remove and reinstall 3-Way Mixing Valve.

31. Remove and reinstall DDC device w/fitting on existing FCU (Room).

32. Remove and reinstall DDC device w/fitting mechanical equipment (Mechanical Room).

33. Remove and reinstall sprinkler head cover plate.

34. Replace gate valve, bronze body, KS B 2301, size: 50 mm.

35. Replace gate valve, bronze body, KS B 2301, size: 75 mm.

36. Replace check valve bronze body, KS B 2301 size:50mm.

37. Replace check valve, Iron Body, 100mm.

38. Replace check valve, Iron Body, 150mm.

39. Replace 50mm Surface Cleanout.

40. Replace 75mm Surface Cleanout.

41. Replace 100mm Surface Cleanout.

42. Replace domestic gas burner type hot water heater, 398MBH or under.

43. Replace electric domestic water heater, 100 lit, 1.6 kW.

44. Replace electric domestic water heater, 450 Lit., 4.5 kW.

45. Replace galv. steel pipeline, 1 LM, Sch #40 incl. fittings & pipe hangers, size: 15mm.

46. Replace galv. steel pipeline, 1 LM, Sch #40 incl. fittings & pipe hangers, size: 20mm.

47. Replace cast iron soil pipe, hub or flange type, 50 mm dia.

48. Replace cast iron soil pipe, hub or flange type, 75 mm dia.

49. Replace Register or Back Draft Damper, 500mm x 500mm or under.

50. Replace cast iron soil pipe, hub or flange type, 100 mm dia.

51. Replace floor drain, with P-trap, 50 mm dia.

52. Replace floor drain, with P-trap, 100 mm dia.

53. Replace faucet/ hose bibb, 15 mm dia.

54. Replace Water Hammer Arrester Type "A".

55. Replace Water Hammer Arrester Type "B".

56. Replace Water Hammer Arrester Type "C".

57. Replace submersible pump with control panel, water level switch, pump guide 200 GPM,5 HP.

58. Replace submersible pump with control panel, water level switch, pump guide 300 GPM,10 HP.

59. Replace fan coil unit, floor mounted, 3 row coil, manual air vent, 3 speed switch, UL-listed motor, washable filter, fresh air intake grille,300 CFM 12,000BTU/h.

60. Replace fan coil unit, floor mounted, 3 row coil, manual air vent, 3 speed switch, UL-listed motor, washable filter, fresh air intake grille, 500 CFM, 24,000BTU/h.

61. Replace fan coil unit, above ceiling mounted, UL motor, 300 CFM 12,000BTU/h.

62. Replace fan coil unit, above ceiling mounted, UL motor, 500 CFM, 24,000BTU/h.

63. Replace Roof Ventilator, Direct Driven, 815 CFM Under, 1/4" SP.

64. Replace Roof Ventilator, Direct Driven, 2,050 CFM Under, 1/4" SP.

65. Replace Roof Ventilator, Belt Driven, 1,650 CFM Under, 1/4" SP.

66. Replace Wall Ventilator, Direct Driven,1,320 CFM,1/4 HP.

67. Replace Wall Ventilator, Direct Driven,1,983 CFM,1/4 HP.

68. Replace bathroom exhaust fan, grille, backdraft damper, 260 CFM.

69. Replace Grille or louver or turning vane, 300mm x 300mm or under.

70. Replace Ceiling Diffuser, Round or Square w/ Damper, 200 mm Dia. or Under, Aluminum.

71. Replace Grille or Louver or Turning Vane, 500mm x 500mm or under.

72. Replace Ceiling Diffuser, Round or Square w/ Damper, 300 mm Dia. or Under, Aluminum.

73. Replace Grille or Louver or Volume Damper or Turning Vane, 700mm x 700mm or under.

74. Replace air duct, 0.6mm thk. (#24GA), without insulation.

75. Replace Register or Back Draft Damper, 300mm x 300mm or under.

76. Replace residential type range hood, 30" W, 2-speed, 210 CFM.

77. Replace insulated flexible duct for diffuser connection, 150 - 200 mm dia., 3m LG.

78. Replace dryer vent kit, flexible hose duct, weather cap with clamp.

79. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 15mm dia, 50mm thk, including adhesive & tape cover for pipeline.

80. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 20mm dia, 50mm thk , including adhesive &

81. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 25mm dia, 50mm thk, including adhesive &

82. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 32mm dia, 50mm thk, including adhesive &

83. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 40mm dia, 50mm thk, including adhesive &

84. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 50mm dia, 50mm thk, including adhesive &

85. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 65mm dia, 50mm thk , including adhesive &

86. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 80mm dia, 50mm thk, including adhesive &

87. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 100mm dia, 50mm thk, including adhesive &

88. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 15mm dia, 40mm thk, including adhesive &

89. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 20mm dia, 40mm thk , including adhesive &

90. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 25mm dia, 40mm thk, including adhesive &

91. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 32mm dia, 40mm thk, including adhesive &

92. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 40mm dia, 40mm thk, including adhesive &

93. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 50mm dia, 40mm thk, including adhesive &

94. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 65mm dia, 40mm thk, including adhesive &

95. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 80mm dia, 40mm thk, including adhesive &

96. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 100mm dia, 40mm thk, including adhesive &

97. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 15mm dia, 25mm thk, including adhesive &

98. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 20mm dia, 25mm thk, including adhesive &

99. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 25mm dia, 25mm thk, including adhesive &

100. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 32mm dia, 25mm thk, including adhesive &

101. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 40mm dia, 25mm thk, including adhesive &

102. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 50mm dia, 25mm thk, including adhesive &

103. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 65mm dia, 25mm thk, including adhesive &

104. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 80mm dia, 25mm thk, including adhesive &

105. Replace pipe insulation, flexible elastomeric cellular (Armaflex), 100mm dia, 25mm thk, including adhesive & tape cover for pipeline.

106. Replace duct insulation, flexible elastomeric cellular, 50 mm thk.

107. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 15 mm dia, 1 LM.

108. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 20 mm dia, 1 LM.

109. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 25 mm dia, 1 LM.

110. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 32 mm dia, 1 LM.

111. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 40 mm dia, 1 LM.

112. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 50 mm dia, 1 LM.

113. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 65 mm dia, 1 LM.

114. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 80 mm dia, 1 LM.

115. Replace pipe Insulation Protective Jacketing, Aluminum, 25 mm thk, 100 mm dia, 1 LM.

116. Replace Hot Water Heating Boiler, (398 MBTU/h).

117. Replace Hot Water Heating Boiler, (597 MBTU/h).

118. Replace Hot Water Heating Boiler, (796 MBTU/h).

119. Replace Air Separator w/ Strainer, 32mm Dia.

120. Replace Air Separator w/ Strainer, 40mm Dia.

121. Replace Air Separator w/ Strainer, 50mm Dia.

122. Replace Air Separator w/ Strainer, 65mm Dia.

123. Replace unit heater, horizontal or vertical type, hot water heating coil, up to 8,000 kcal/h.

124. Replace finned tube radiator, with non-electric control valve, 2 row-1 m LG.

125. Replace finned tube radiator, with non-electric control valve, 2 row-2 m LG.

126. Replace automatic air vent with stop valve 15mm.

127. Replace gate valve, glove valve or balancing cock, threaded bronze body, 15 mm.

128. Replace gate valve, glove valve or balancing cock, threaded bronze body, 20 mm.

129. Replace gate valve, glove valve or balancing cock, threaded bronze body, 25 mm.

130. Replace gate valve, glove valve or balancing cock, threaded bronze body, 32 mm.

131. Replace gate valve, glove valve or balancing cock, threaded bronze body, 40 mm.

132. Replace gate valve, glove valve or balancing cock, threaded bronze body, 50 mm.

133. Replace gate valve, glove valve or balancing cock, threaded bronze body, 65 mm.

134. Replace gate valve, flanged, cast iron body, OS&Y, 80 mm dia.

135. Replace gate valve, flanged, cast iron body, OS&Y, 100 mm dia.

136. Replace gate valve, flanged, cast iron body, OS&Y, 150 mm dia.

137. Replace gate valve, flanged, cast iron body, OS&Y, 200 mm dia.

138. Replace check valve, flanged bronze body, 15 mm dia.

139. Replace check valve, flanged bronze body, 20 mm dia.

140. Replace check valve, flanged bronze body, 25 mm dia.

141. Replace check valve, threaded bronze body, 32 mm dia.

142. Replace check valve, threaded bronze body, 40 mm dia.

143. Replace check valve, threaded bronze body, 50 mm dia.

144. Replace check valve, threaded bronze body, 65 mm dia.

145. Replace check valve, flanged, cast iron body, 80 mm dia.

146. Replace check valve, flanged, cast iron body, 100 mm dia.

147. Replace check valve, flanged, cast iron body, 125 mm dia.

148. Replace check valve, flanged, cast iron body, 150 mm dia.

149. Replace expansion tank, bladder or diaphragm type, tank cap.: 100 liter (26.4 gal).

150. Replace expansion tank, bladder or diaphragm type, tank cap.: 200 liter (52.8 gal).

151. Replace water storage tank,150PSI Working Pressure, equipped with temperature relief valve, thermometer, glass lining & necessary tapping, insulation covering, stainless steel type, tank cap.: 300 gallons.

152. Replace water storage tank,150PSI Working Pressure, equipped with temperature relief valve, thermometer, glass lining & necessary tapping, insulation covering, stainless steel type, tank cap.: 500 gallons.

153. Replace black steel pipe schedule #40 with fitting & support, without insulation,15mm dia.

154. Replace black steel pipe schedule #40 with fitting & support, without insulation,20mm dia.

155. Replace black steel pipe schedule #40 with fitting & support, without insulation,25mm dia.

156. Replace black steel pipe schedule #40 with fitting & support, without insulation,32mm dia.

157. Replace black steel pipe schedule #40 with fitting & support, without insulation,40mm dia.

158. Replace black steel pipe schedule #40 with fitting & support, without insulation,50mm dia.

159. Replace black steel pipe schedule #40 with fitting & support, without insulation,65mm dia.

160. Replace black steel pipe schedule #40 with fitting & support, without insulation,80mm dia.

161. Replace black steel pipe schedule #40 with fitting & support, without insulation,100mm dia.

162. Replace copper tube L type w/ fitting & support, without insulation, 15mm dia.

163. Replace copper tube L type w/ fitting & support, without insulation, 20mm dia.

164. Replace copper tube L type w/ fitting & support, without insulation, 25mm dia.

165. Replace copper tube L type w/ fitting & support, without insulation, 32mm dia.

166. Replace copper tube L type w/ fitting & support, without insulation, 40mm dia.

167. Replace copper tube L type w/ fitting & support, without insulation, 50mm dia.

168. Replace copper tube L type w/ fitting & support, without insulation, 65mm dia.

169. Replace copper tube L type w/ fitting & support, without insulation, 80mm dia.

170. Replace copper tube L type w/ fitting & support, without insulation, 100mm dia.

171. Replace Package Air Conditioning…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .