AF 1655
A
FORM
FEB 74
B
C
D
8 7 6 5
CODE IDENT NO.
ENGINEERING DRAWING LAYOUT D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
4 3 2
DRAWING NO
SHEET OF
A
B
C
D
DATE
8 7 6 5 4
NONE 1 9
TITLE SHEET AND GENERAL NOTE
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-190010
C-0
S C H E D U L E O F D R A W I N G S
REVISION STATUSDESCRIPTION OF DRAWINGS
GENERAL NOTE
DESCRIPTION OF DRAWINGS REVISION STATUS
TITLE SHEET, GENERAL NOTEC - 001
SUWON AB
REPAIR TENNIS COURT, B-2133
DESIGN DRAWING
LOCATION PLANC - 1
REMOVAL PLAN C - 2
REMOVAL PLAN DETAILSC - 3
SITE PLANC - 4
1. ALL CONCRETE WORK SHALL CONFORM TO ACI 211.1 AS MODIFIED BY AIR FORCE ETL 97-05 (CHANGE1).
2. AGGREGATES SHALL CONFORM TO ASTM C33.
3. CEMENT SHALL CONFORM TO ASTM C150, TYPE I OR II.
4. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH UFGS 32 13 11.
5. CONCRETE SHALL BE CONTINUOUSLY MOIST-CURED FOR AT LEAST SEVEN DAYS FOLLOWING COMPLETION OF CONCRETE
MAY BE USED INSTEAD OF MOIST-CURING.
6. SUBMIT A JOINT PLAN FOR APPROVAL PRIOR TO PLACING CONCRETE.
7. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED,
ALL LAITANCE REMOVED, THOROUGHLY WETTED, AND SLUSHED
8. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICE'S 48 HOURS PRIOR TO THE POURING OF ANY CONCRETE, NO POUR SHALL PROCEED WITHOUT THE CONSENT OF CONTRACTING OFFICE'S REPRESENTATION.
CONCRETE NOTES
NEW CONCRETE.
1. SPECIFIED FLEXURAL STRENGTH FOR CONCRETE PAD IS 4.5 MPA (650 PSI) AT 90 DAYS,
AS DETERMINED BY TEST MADE IN ACCORDANCE WITH ASTM C 78 OR KS F 2325.
DESIGN CRITERIA;
2. THE MAXIMUM ALLOWABLE SLUMP OF THE CONCRETE AT THE POINT OF PLACEMENT IS 75mm (3in.).
FINISHING OPERATION. ALTERNATIVELY, A WHITE PIGMENTED MEMBRANCE FORMING CURING COMPOUND MEETING COE CRD-C 300
9. SUBMIT RESULTS OF FREEZING-THAWING TEST, SIEVE ANALYSIS, ALKALI SILICA REACTIVITY, AND L.A. ABRASION TEST.
10. SUBMIT A RESULT OF DENSITY TEST FOR APPROVAL PRIOR TO PLACING CONCRETE.
11. THE CONTRACTOR SHALL MAKE 18 SPECIMENS FOR THE STRENGTH TEST FOR EACH TIME WHEN CONCRETE IS POURED.
9 SPECIMENS SHALL BE CURED AT THE JOB SITE WHILE THE OTHER 9 SPECIMENS SHALL BE CURED IN THE LAB.
3. THE COMPRESSIVE CONCRETE STRENGTH AT 28 DAYS FOR MANHOLE IS MINIMUM 27MPA
SECTION DETAILSC - 5
FENCE DETAILSC - 6
ELECTRICAL SITE PLANE - 1
LIGHTING FIXTURESE - 2
NA
04 22
W
AF 1655
A
FORM
FEB 74
B
C
D
8 7 6 5
CODE IDENT NO.
ENGINEERING DRAWING LAYOUT D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
4 3 2
DRAWING NO
SHEET OF
A
B
C
D
DATE
8 7 6 5 4
NONE 2 9
LOCATION PLANLOCATION PLAN
WO# 514-90010, SUWON AB
THIS PROJECT
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-190010
C-1
FORM
FEB 74
B
C
D
8 7 6 5
CODE IDENT NO.
ENGINEERING DRAWING LAYOUT D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
4 3 2
DRAWING NO
SHEET OF
A
B
C
D
DATE
8 7 6 5 4
NONE 3 9
REMOVAL PLAN
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-190010
C-2
REMOVAL SCHEDULE
EXST.A.C. PAVED ROAD
B-2134
ITEMS NO
DESCRIPTIONS QUANTITIES REMARK
BASKETBALL GOAL POST & BACKBOARD 4EA SEE C-3, 1
CHAIN LINK FENCE 104 M SEE C-3, 2
3 CONCRETE SIDEWALK 13 SM
4 TENNIS POST/ NET 1 SET
FORM
FEB 74
B
C
D
8 7 6 5
CODE IDENT NO.
ENGINEERING DRAWING LAYOUT D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
4 3 2
DRAWING NO
SHEET OF
A
B
C
D
DATE
8 7 6 5 4
NONE 4 9
REMOVAL PLAN DETAILS
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-90010
C-3
LEGEND
CONTRACTOR SHALL SUBMIT THE SHOP DRAWING AFTER SURVEYING THE LOCATION AND LEVEL.
DURING SURVEY, CONTRACTOR SHALL ACCOMPANY 607 MMS/CE RESPONSIBLE PERSONNEL
THE FINAL FINISH LEVEL SHALL BE MATCHED WITH EXISTING ASPHALT PAVEMENT AND EARTH LEVEL .
REMOVE EXISITING BASKETBALL GOAL POST & BACKBOARD REMOVE EXISTING CHAIN LINK FENCE ENCLOSURES
FORM
FEB 74
B
C
D
8 7 6 5
CODE IDENT NO.
ENGINEERING DRAWING LAYOUT D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
4 3 2
DRAWING NO
SHEET OF
A
B
C
D
DATE
8 7 6 5 4
NONE 5 9
SITE PLAN
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-90010
C-4
EXST. A.C. PAVED ROAD
B-2134
INSTALL NEW FENCE (H=2 M, L=102 M)
SEE C-6, 1
INSTALL 12" (13MM) THK. URETHANE CHIP
OVER NEW A/C PAVEMENT, SEE C-5, 1
(APPROX. 660 M2)
INSTALL SIDEWALK (1.2MX2M)
SEE C-5, 2
INSTALL DITCH CORSSING (1.2MX5M)
INSTALL NEW FENCE DOOR, W=1.0M
SEE C-6, 2INSTALL NEW FENCE DOOR, W=1.0M
SEE C-6, 2
REPLACE EXIST. MANHOLE (1.6MX1.6M)
REPLACE EXISTING CON'C DITCH
NOTE: FOR MANHOLE AND DITCH, REFER TO OMA STANDARD DRAWINGS FOR THE DETAILS AND SUBMIT SHOP DRAWINGS
REPLACE EXIST. CON'C STRUCTURE
SODDING AROUND TENNIS COURTS
APPROX. 150SM
APPLY COURT MARKING, SEE C-5, 3
INSTALL NEW PORTABLE TENNIS POST/NET (C-5, 4)
APPLY STEEL GRATING
W=400MM, DEPTH 500MM, L=20M
CODE IDENT NO.
ENGINEERING DRAWING LAYOUT D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
DRAWING NO
SHEET OF
DATE
SECTION DETAILS
6 9
C-5
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-90010
114.0'
.0
'4'
4'
21.0'
.0
.0
CL
21.0'18.0' 18.0'
ENGINEERING DRAWING LAYOUT DENGINEERING DRAWING LAYOUT DAF 1655
A
FEB 74
8 7 6 5
ENGINEERING DRAWING LAYOUT D
4 3 2 1
8 7 6 5 4
AA
B
C
D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
DRAWING NO
SHEET OF
DATE
FENCE DETAILS
7 9
C-6
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-90010
00 20
Conc'
D POST CAP(97×73×52)FRAME
(47×23×1.6t)
D POST(97×73×52×2.0t)
MESH(Φ5×50×150)
ENGINEERING DRAWING LAYOUT DENGINEERING DRAWING LAYOUT DAF 1655
A
FEB 74
8 7 6 5
ENGINEERING DRAWING LAYOUT D
4 3 2 1
8 7 6 5 4
A
B
C
D
FORM
FEB 74
B
C
D
8 7 6 5
CODE IDENT NO.
ENGINEERING DRAWING LAYOUT D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
4 3 2
DRAWING NO
SHEET OF
A
B
C
D
DATE
8 7 6 5 4
NONE 8 9
ELECTRICAL SITE PLAN
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-90010
E-1
EXST. A.C. PAVED ROAD
B-2134
REPLACE EXISTING LIGHTING FIXTURES WITH NEW LED LIGHTING FIXTURES WITH ACCESSORIES
2EA LED LIGHTING FIXTURES PER ONE POLE, TOTAL 8EA LED LIGHTING FIXTURES, SEE E-2, 1
REPLACE EXIST. ELECTRICAL PANEL W/ CIRCUIT BREAK (30A) AND SWITCH
REPAINT EXIST. CONDUIT AND STEEL POST
NOTE
REUSE EXISTING POLES AND CONDUITS
208V 1P, 2-#6, G#10 AWG
REPLACE EXISTING ELECTRICAL LINE LIGHTING FIXTURES TO ELECTRICAL PANEL (ENCLOSURE NEMA 3R TYPE)
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SIZE
SCALE
TITLE
AS SHOWN
PARTS LIST
DRAWING NO
SHEET OF
DATE
LIGHTING FIXTURES
9 9
E-2
REPAIR TENNIS COURT, B-2133 AT SUWON AB
WO# 514-90010
ENGINEERING DRAWING LAYOUT DAF 1655
A
FEB 74
B
C
D
8 7 6 5
ENGINEERING DRAWING LAYOUT D
4 3 2 1
8 7 6 5 4
| C-0 |
| C-1 |
| C-2 |
| c-3 |
| c-4 |
| c-5 |
| c-6 |
| e-1 |
| e-2 |