AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of amendment 0001 is to provide answ ers to vendor questions received and to provide revised Kit Requirements dated 9-11-2019.

All other terms and conditions remain unchanged.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 10

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 11-Sep-2019

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9098S19Q0034

X 9B. DATED (SEE ITEM 11)

29-Aug-2019

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

11-Sep-2019

CODE

ROCK ISLAND ARSENAL (ACC-RI)

JOINT MANUFACTURING & TECHNOLOGY CENTER

BLDG 211 RODMAN AVENUE

1 ROCK ISLAND ARSENAL

ROCK ISLAND IL 61299-5000

W9098S 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W9098S19Q0034

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE

The following have been added by full text:

AMENDMENT 0001 DATED 9-11-2019

1. The purpose of this Amendment 0001 is to provide response to vendor questions received.

2. The closing date remains unchanged.

3. Vendor questions w/Government responses are as follows:

Question 1: It is our understanding that the price matrix is being used to award the contract to the company with the lowest total evaluated price. Once awarded the RFQ will result in a single, firm fixed-price, five year, IDIQ contract. Please elaborate on what the firm fixed-price means and how it gets determined from term to term.

Government Response: The FAR definition of Firm Fixed-Price is; “a firm fixed-price contract provides for a price that is not subject to any adjustment on the basis of a contractor’s cost experience in performing the contract.”

Per the Solicitation Narrative, Page 5, Paragraph 8 titled PRICING which states; Award will be made to the lowest priced, responsive, repsonsible contractor whose quote conforms to the solicitation requirements (to include delivery) and represents the lowest total evaluated price.

Any order placed against the resulting contract will be at the unit prices offered by the contractor for the applicable quantity range and ordering period.

The Total Evaluated Price will be calculated as follows by calculating a Weighted Evaluation price by mulitplying the quoted unit prices for each quantity range and each ordering period by their respective weight and maximum quantity and summing their totals. The weight associated with each quantity range represents the likelihood that an order, if placed, would be placed within that range. The Total Evaluated price will be then determined by adding the sum of the Weighted Ordering Period Evaluation Prices for each ordering period plus FAT.

Question 2: What items are going to be placed in the Pelican Case?

Government Response: It is the Government’s expectation that the vendor will design and package the equipment within the identified cases. The design shall be such that the kits are capable of passing the required testing listed within this RFQ.

Question 3: Interface Cable…..There is an interface cable that runs between the ICON Scout Controller and the PowerMax 65 Plasma Cutter. The vendor will need to install the appropriate plug-end on each interface cable so that the PMX 65 and the Scout can communicate with each other.

Does the Government expected a vendor to acquire the appropriate interface cables and include in the price matrix as part of this RFQ, OR, does the Government intend to provide the interface cables to the vendor to have the necessary plug installed?

Government Response: See Page 7, Paragraph 1 which states “1 each; FastCut CNC, Inc. Icon Scout, 4 x 4, Plasma Table (to include all cables necessary to interface between the CNC Plasma Table and the Plasma Cutter Power Supply specified in drawing 11B5090142 using the Plasma Cutter Supply interface port….)

A vendor’s price shall include all equipment, cables, and cases as one unit price.

Question 4: Please confirm if the Government will be providing their own laptop and that a PC with Windows is not included in this RFQ?

Government Response: The Government confirms that they will provide their own laptop with Windows. However, the vendor is required to provide any/all software necessary to operate the Plasma Table is required as part of the Kit.

See Revised KIT REQUIREMENTS dated 9-11-2019

Question 5: Under the Buy American Certificate (Page 36 of the RFQ). Are the end products under consideration; the ICON 4 x 4 Scout, Plasma Table Trunk, Pelican Cutter Accessory Case, and Machine Torch? OR does the end item under consideration the complete Plasma Table Kit which is made up of the ICON Scout, Plasma Table Trunk, Accessory Case, and Machine Torch?

Government Response: The Buy Amercian certificate on Page 36 of this RFQ refers to the end product/item as a complete Plasma Table Kit (to included the ICON Scout, Plasma Table Trunk, Accessory Case, and Machine Torch), not as individual components.

3. POCs for this amendment are as follows:

Contract Specialist, Sabrina Lowe, Email: sabrina.l.lowe.civ@mail.mil Contracting Officer, Jessica Pearson, Email: jessica.l.pearson2.civ@mail.mil

(End of Amendment 0001)

REVISED KIT REQUIREMENTS 9-11

1. A complete MWMSS Plasma Table Kit consists of the following equipment:

1 each; FastCut CNC, Inc. Icon Scout, 4’ x 4’ Plasma Table (to include all cables necessary to interface between the CNC Plasma Table and the Plasma Cutting Power Supply specified in drawing 11B5090142 using the Plasma Cutter Power Supply interface port. [The Plasma Cutting Power Supply specified in drawing 11B5090142 is not part of this requirement] and all necessary software for the CNC Table to communicate and be operational with the Cutter Power Supply, Machine Torch, and the Government furnished Laptop)

1 each; Hypertherm, Duramax, Machine Torch, Model #059477, IAW drawing 11B5190112 1 each; Pelican (or equal) Plasma Cutter Accessory Case, IAW drawing 11B5190799 1 each; Plasma Table Case, IAW drawing 11B5190177

2. GENERAL REQUIREMENTS:

2.1 All equipment and materials used to satisfy this requirement shall be new and unused.

2.2 Hazardous Material Restrictions: The following SHALL NOT BE present in or on any delivered materials, required for the operation and sustainment of the system, or used in final system manufacturing and assembly processes:

a. Asbestos

b. Beryllium and/or Beryllium Alloys

c. Cadmium and/or cadmium Alloys

d. Class I or Class II Ozone Depleting Substances

e. Hexavalent Chromium

f. Lead and/or Leaded Alloys

g. Mercury

h. Nickel and/or Nickel Alloys

i. Radioactive Materials and other group I agents, classified as “Carcinogenic to humans” by the

International Agency for Research on Cancer (IARC) Monographs

2.2.1 The Plasma Table kitting shall be designed such that the user shall have the ability to dispose of the system in full compliance with all applicable United States Federal environmental quality laws and regulations.

2.3. Prior approval from the Government is NOT REQUIRED for the use of any of the following materials:

a. Cadmium on electrical connectors and back shells used to mate with cadmium electrical connectors on

Government Furnished Equipment (GFE)

b. Chemical Agent Resistant Coating (CARC) primers and topcoats

c. Lead-acid Batteries

d. Lead Solder

e. Steel Containing up to 0.35% lead by weight

f. Aluminum containing up to 0.4% lead by weight

g. Cooper and Brass alloys containing up to 4% lead by weight

h. Beryllium and Beryllium alloys used in electrical components

i. Nickel and Nickel alloys used in electrical components

j. Mercury containing components compliant with European Union (EU) Directive 2002/95/EC (RoHS)

3. CASE (Storage Trunks) REQUIREMENTS:

3.1 The storage trunks shall provide for storage and transportation of the plasma table equipment. The contractor shall develop a storage scheme and component layout that utilizes and maximizes the two trunks as described in drawings 11B5190177 and 11B5190799. Like items, to the maximum extend practical shall be stored in the same proximity within the trunks. The layout of the storage trunks shall not create any safety or health hazards throughout the life cycle of the system, e.g. sharp components pointing up.

3.2 SIZE: the contractor shall use a maximum of two different storage trunks per kit as described by 11B5190177 and 11B5190799. All storage trunks shall be uniform in size and color throughout the life of the contract. The size of the storage trunk specified in drawing 11B5190177 shall allow for lifting the empty trunk by the number of lifters without interference with each other while lifting. The size of the storage trunk specified in drawing 11B5190799 shall allow for lifting the fully loaded trunk by the number of lifters without interference with each other while lifting.

3.3. WEIGHT:

a. The weight limit of the empty storage trunk (11B5190177) shall be IAW MIL-STD-1472, section 5.8.6.3, table XXXVIII, Male and Female, Carry 33 feet.

b. The weight limit of the fully loaded storage trunk (11B5190799) shall be IAW MIL-STD-1472, section 5.8.6.3, table XXXVIII, Male and Female, Lift 5 feet from floor.

c. Each fully loaded removable layer within both (11B5190177 and 11B5190799) storage trunks shall be IAW MIL-STD-1472, section 5.8.6.3, table XXXVIII, Male and Female, Carry 33 feet.

3.4. MATERIALS: All materials used shall be corrosion resistant or suitably processed to resist corrosion. Any exposed elastomeric parts exposed to air shall be ozone and ultraviolet (UV) light resistant. Hardware that protrudes into the storage trunk’s interior shall not present a hazard to users hands or the component load. The contractor shall avoid the use of toxic chemical, hazardous substances, and Ozone Depleting Chemicals (ODCs).

3.5. RAPID INVENTORY/COMPONENT LAYOUT: A diagram showing the location the components contained in each trunk shall be included and permanently affixed to the inside of the lid(s). The diagram shall include photographs or drawings of the components, location by drawer or layer number, Original Equipment Manufacturer (OEM) part number, contractor part number (not required but allowed), and warranty status (i.e. L=Lifetime, M= Manufacture Warranty [1 year, 2 year, etc.] or N=No Warranty) of each component in its loaded position within the trunk. The means chosen to affix the diagram to the inside of the lid shall not inhibit the ability to open or close the container. In the event that an item is missing from the set, the user(s) shall be provided with a means to quickly identify the specific item by name, description, and part number. This diagram shall serve as an inventory sheet to facilitate rapid inventory. The diagram shall be water and dust resistant and durable.

Example:

Warranty (WTY) Definitions: L=Lifetime, M=Manufacturer Warranty, N=No Warranty

Nomenclature QTY WTY Brand/Part Number

LOCATION

Plasma Table 1 EACH M ( #of years)

FASTCUT,

CNC/Part number

XXX

3.6. ORGANIZERS:

a. Any organizers used shall provide a cutout (recessed) storage position for each component that maintains the position of each component and protects them against damage during rough handling and shock and vibration experienced during transportation.

b. The contractor shall use four-pound density Cross Linked Polyethylene (XLPE) foam to construct organizers.

c. The organizers shall use a colored foam for all but the bottom layer under each component, which shall be a different strongly contrasting color underneath the components to aid in rapid inventory. The colors used shall be consistent throughout and not changed once production beings.

d. If utilizing removable organizing layers, each layer shall have a bottom rigid enough to hold the components when only supported by the outer 1-1/2 inches of the ends of the layer (two sides furthest apart) without sagging more than 5 percent of the length.

e. All materials used to add rigidity to the organizing layers shall be either a corrosion resistant metal or plastic (no wood). The organizers shall have any materials added for rigidity permanently attached to the liner that they are supporting; and shall not present any safety hazards from rough surfaces, sharp edges, or sharp corners.

f. Any materials selected shall be resistant to water, refrigerants, automotive oils, greases, lubricants, fuels including gasoline, diesel fuel, JP-8 and JP-4, alcohols and cleaning agents.

g. Removable layers shall have cutouts that allow the soldiers to get their gloved hands under the layer or handles incorporated into the layer. Either cutouts or handles shall conform to MIL-STD-1472 requirements. The position of any handles added to a layer shall allow the layer to remain level during removal, i.e. balanced. All layers utilizing handles shall have the handles permanently attached to the layer in a fashion that prevents damage to the foam or rigid bottom during lifting. The size of the handles shall be appropriate for the amount of weight being lifted per MIL-STD-1472, i.e. the heavier the lift, the wider the handle to distribute the load across the fingers.

h. Each component cutout shall allow easy removal of the component and shall include as necessary pick holes, cutouts, recessed areas, or protrusion of components above the component organizing liner.

3.7 PALLET FEATURE: The storage trunk specified in drawing 11B5190177 shall have a pallet feature that allows for ease of forklift movement. This pallet feature shall be permanently affixed to the storage trunk and capable of supporting a fully loaded trunk.

3.8. LIFTING HANDLES: Each storage trunk shall have lifting handles that meet MIL-STD-1472 requirements.

The handles shall be placed in such a manner that the lifters do not interfere with each other while lifting and meet the requirements of MIL-STD-1472, section 5.8.6.3.6. For storage trunk specified in 11B5190177 the rating and number of handles shall be no less than the weight of the empty trunk IAW MIL-STD-1472, section 5.8.6.3, Table XXXVII for Male and Female, Carry 33 Feet. For storage trunk specified in 11B5190799, the rating and number of handles shall be no less than the weight of a fully loaded trunk IAW MIL-STD-1472, Section 5.8.6.3, Table XXXVII for Male and Female, Lift 5 Feet from Floor. The handles shall be installed using secure mechanical fasteners, i.e. rivets or screws that are not removable with a screwdriver. The handles shall not affect the strength and firmness of the case. While in use, the handles shall stop at approximately a 90-degree angle to the face of the case. Recessed molded handles are not acceptable.

3.8.1 The design of storage trunks, including the handle(s) and clasp(s), shall allow the user wearing insulated work gloves to open/close/carry the storage trunks. The user(s) shall be able to open and close each clasp or latch using only one gloved hand.

3.9. COLOR: The exterior of the storage trunks shall be one of the following approved colors:

The exterior surfaces of each storage trunk shall be clean, corrosion resistant, non-reflective, non-glossy, and have no sharp edges or projections.

3.10. CORROSION PREVENTION. To minimize the occurrence of corrosion in storage, each storage trunk shall include Volatile Corrosion Inhibitor (VCI) module(s) with a minimum life of 2 years. The contractor shall position the VCI module(s) such that the released molecules can circulate throughout into the storage trunks to protect the components from corrosion. The contractor shall position the VCI module(s) so they are easily replaceable.

3.11. PRESSURE DIFFERNTIAL COMPENSATION: The design of the storage trunks shall allow for compensation of differential pressures that may develop because of changes in temperature or in altitude. A devise such as a pressure relief valve shall serve this purpose. The devise shall not alter the waterproof, dustproof, or any other design requirement of the storage trunk.

3.12. LOCKING FEATURE: Each Storage trunk shall include a locking feature. If using padlocks, padlocks must conform to the requirements of Commercial Item Description A-A-59486. With padlocks installed, the storage trunk locking feature (exclusive of the padlock) shall resist intrusion by prying for no less than 2-minutes. The eye through which the padlock fits shall be capable of withstanding a pull of no less than 250 pounds. The storage trunks shall include a means to tether the trunks (alone or in multiple) to a post or pillar with a chain or cable that can be locked with a padlock. The tethering feature shall withstand a pull of no less than 250 pounds.

APPROVED

COLOR

SAE AMS-STD-595

137 Olive Drab 34096 383 Green 34094

Black 37030 686 Tan 33446

Sand 33303

3.13. MARKINGS, LABELS, AND DATA PLATES:

a. All components that exceed the safe limits for a single person to lift using both hands shall have a caution sign/label provided. All product safety signs/labels shall conform to ANSI Z535.4. The number of persons assigned for lifting each component shall be determined using the guidance of section 5.8.6.3 of MIL-STD-1472. Lifting limits established for a single person is 42 pounds.

b. Marking Durability: All markings, identification, warning labels, and plates shall be permanently affixed to the trunk. They shall be resistant to deterioration caused by the elements (i.e. heat, cold, solar radiation, water, and petroleum products) to the extent that they will remain intact and readily legible for a minimum of 25 years. The markings shall not adversely affect the life and utility of the storage trunks and system load. All markings shall be printed using the English language and may be supplemented by graphical symbols.

c. Warning Labels -Storage Trunks: The storage trunk specified in drawing 11B5190799 shall have a warning label conforming to ANSI Z535.4 prominently displayed on the exterior of the box. The warning label shall state the number of persons required to lift the fully loaded storage trunk (i.e. “Two person lift required”, “Three person lift required”, etc) as well as the weight of the object in accordance with MIL- STD-1472, section 5.8.6.3.12. If the total weight of the filled storage trunk is equal to or less than the weight of a one-person lift (37-pounds in accordance with MIL-STD-1472, section 5.8.6.3 and Table XXXVIII, Male and Female, Lift 5 Feet from Floor), a warning label will not be required.

d. Warning Labels - Layers: Removable layers weighing more than a 1-person lift (42-pounds in accordance with MIL-STD-1472, section 5.8.6.3 and Table XXXVIII, Male and Female, Carry 33 Feet) shall have a warning label conforming to ANSI Z535.4 prominently displayed and permanently affixed to the top of the layer. The warning label shall state the number of persons required to lift the layer (i.e. “Two person lift required”, “Three person lift required”, etc) as well as the weight of the layer in accordance with MIL-STD-1472, section 5.8.6.3.12.

e. Stenciling: The storage trunk (IAW 11B5190177) shall be stenciled on the long side of the trunk and top that reads; “PLASMA TABLE TRUNK”. If removable organizing layers are used in the design, trunk shall also include additional stenciling on the long sides of the trunk and top that read: “REMOVE ITEMS AND LAYERS INDIVIDUALLY”. Storage trunk (IAW 11B5190799) shall be stenciled on the long side of the trunk and top that read: “PLASMA CUTTER ACCESSORY CASE”.

All stencil lettering shall be a minimum letter height of 1.5” and be black in color (except over a black background, in which case letters shall be 383 Green/color 34094 per SAE AMS-STD-595). Paint shall confirm to the A-A-2787 Type I industrial enamel.

f. Data Plates: Each storage trunk shall have a data plate permanently and legibly marked with the following information:

End Item Nomenclature: PLASMA TABLE KIT End Item LIN:

End Item NSN:

End Item Serial Number:

Specification Data:

Weight ___________ lbs., Volume ________cu ft., Length __________in.

Width ___________in., Height ___________in.

Manufacturer (Cage):

Chest _____of ______ Contract/Purchase Order Number:

The data plate shall be plainly visible, in an easy to see location, on the exterior of the storage trunk.

Plate(s) shall not be placed on the lid (Top). Data plates shall conform to the commercial item description A-A-50271 Composition A, Class 2 or Composition D.

g. Unique Item Identification: Each storage trunk shall be marked with a unique item identifier (UID) that has machine-readable data elements that will distinguish it from all other like and unlike items. Each UID shall be globally unique and unambiguous. The UID data elements shall be contained in a Data Matrix ECC200 symbol IAW ISO/IEC 16022. Marking shall conform to MIL-STD0130 and remain intact and readily human/machine readable for a minimum of 25 years. The contractor shall bear the responsibility to populate the UID registry with the parent UID and any children (components) relating to that parent UID.

If construct number 2 is used (serialization within the original part number of the enterprise), the contractor shall maintain the original part number on the item for the life of the item. For more guidance refer to DFARS 252.211-7003 and/or http://www.acq.osd.mil/dpap/UID/ for additional information.

4. GENERAL QUALITY ASSURANCE (QA) DOCUMENTATION: Every delivery to RIA-JMTC shall contain the following documentation:

a. Certificate of Conformance (COC) per FAR 52.246-15.

b. Certified Material Test Reports (CMTR). At a minimum, the CMTR shall include the following information:

- Name of Company providing the CMTR and the date of submission.

- Contract Number

- A brief description of the item for which the CMTR is being provided.

- The test report showing objective data/results to certify the requirement was met.

- Data Results shall include but not limited to the follows: Water Intrusion, Impact Resistance, Hot and Cold Drop, Rail Impact

- The signature and title of the certifying official.

4.1. All items delivered under this IDIQ contract shall conform to all the requirements of the contract. The Government reserves the right to re-verify conformance with requirements at any time during the life of the contract if determined necessary, e.g. whenever there is lapse in production for a period in excess of 1-year, or whenever a change occurs in place of performance, manufacturing processes, material used, specification, or source of supply.

It is the responsibility of the Contractor to notify the Government/Contracting Officer when such a situation arises, so that a determination can be made concerning the need for additional testing and inspection. If the decision to perform additional testing and inspections is determined necessary, the costs for any additional testing/inspections shall be borne by the Contractor, unless the change was directed by the Government. Further, any production delays caused by additional testing/inspections is not an acceptable basis for an excusable delay as defined by FAR 52.212- 4 of the contract.

4.2 Failure to provide the required documentation with each shipment is cause for rejection of the shipment at the contractor’s expense.

5. FIRST ARTICLE TEST (FAT) REQUIREMENTS: The contractor shall furnish one (1) Plasma Table Kit to be used as a First Article Test (FAT). The contractor is responsible for successfully conducting all testing and inspections specified herein prior to Government final inspection/acceptance of supplies. The contractor shall use its own or any other non-government facility suitable for the performance of FAT, unless otherwise disapproved by the Government. At any point in the life of the contract, the Government reserves the right to conduct their own FAT to verify that the products supplied meet the requirements described herein.

5.1. A fully loaded MWMSS Plasma Table Kit will be subject to the following verification (FAT) testing:

Water Intrusion: With the lid closed and fastened, the storage trunks shall withstand rainfall, at a minimum rate of 4inch/hr. without water entry, when tested IAW MIL-STD-810, 506.6, Procedure I. Prior to testing, the storage trunks shall have been unlatched, opened, closed, and re-latched no further than 10 times. Any rubberized seals used to meet this requirement shall be easy to replace by soldiers when damaged in the field.

Impact Resistance: With the storage trunks closed and latched in their normal resting position, the storage trunks shall withstand impacts from dropped objects. At a minimum, they shall withstand an impact from a steel bar weighting at least 3 pounds dropped from a height of 8 feet. The bar shall have a cross section no larger than 3/16 x 1-inch and with edge radii no larger than 1/16 inch. The orientation of the bar shall be such that the bar lands narrow end down on each lid. The impact shall not cause penetration to the trunk, degradation to trunk functionality, or damage to internal components.

Elevated Temperature Resistance/Performance (Hot Drop): When fully loaded with the specified components, closed, latched, and stored for three (3) hours at a temperature no less than 120 degrees Fahrenheit, the storage trunk (11B5190177) shall withstand a drop of at least 6 inches onto concrete or similar unyielding surface within five (5) minutes of being removed from the temperature chamber. The storage trunk (11B5190799) shall withstand a drop of at least 24 inches under the same conditions. The storage trunks shall suffer no permanent damage or degradation to the proper functioning or the storage trunk. Additionally, the components shall not be damaged or dislodged and moving freely around in the storage trunk.

Cold Temperature Resistance/Performance (Cold Drop): When fully loaded with the specified components, closed, latched, and stored for three (3) hours at a temperature no warmer than -25 degrees Fahrenheit, the storage trunk (11B5190177) shall withstand a drop of at least 6 inches onto concrete or similar unyielding surface within five (5) minutes of being removed from the temperature chamber. The storage trunk (11B5190799) shall withstand a drop of at least 24 inches under the same conditions. The storage trunks shall suffer no permanent damage or degradation to the proper functioning or the storage trunk. Additionally, the components shall not be damaged or dislodged and moving freely around in the storage trunk.

Rail Impact: Each fully loaded storage trunk shall withstand a single 6 mph impact when tested in accordance with ASTM D5277. The storage trunk specified in 11B5190177 shall be oriented so that the longest end of the trunk is perpendicular to the axis of impact. The storage trunk specified in 11B5190799 shall be oriented so that the longest end of the trunk is parallel to the axis of impact. The storage trunk shall suffer no permanent damage or degradation to the proper functioning of the trunks. Additionally, the components shall not be damaged or dislodged and moving freely around in the storage trunks.

Workmanship: A visual, dimensional and manual inspection will be conducted for the FAT unit. The visual inspection shall include verification of completeness of manufacture and assembly, proper cleaning, and free from defects. Dimensional inspection shall include measuring dimensions as identified herein and on associated drawings. Manual inspections shall include the operation of movable parts by hand to assure proper functioning.

6. SOFTWARE REQUIREMENTS: Contractor shall provide, as part of the complete Kit, all necessary software required for the CNC Plasma Table to be operational and allow for the Table to communicate between the Table, Government Laptop, Cutter Power Supply, and the Machine Torch. The minimum requirements for the software are as follows:

a. Software shall not require internet access.

b. Software shall be capable of building g-code for the table from .dxf files.

c. Software system requirements shall not exceed:

-Windows 7

-Processor Multicore, 2.26 GHz with 3 MB of L2 Cache

-RAM: 4 GB

-Video Card: 256 MB, 128-bit Interface, DirectX 10.1 Support

(End of Kit Requirements)

SECTION SF 1449 - CONTINUATION SHEET

The following have been deleted:

KIT REQUIREMENTS 8-27-2019

(End of Summary of Changes)

File details come from the government source that posted it.