4. UOTS Perf Spec
248 KB Posted
- Attached to
- Urban Operations Training Systems (UOTS)
- Solicitation number
- W900KK09R0002
About this file
4. UOTS Perf Spec (Draft rev 2)
Text of this file
DRAFT
PERFORMANCE SPECIFICATION
FOR
URBAN OPERATIONS INSTRUMENTATION AND TRAINING ENVIRONMENTS
Prepared by Program Executive Office Simulation, Training and Instrumentation (PEO STRI) 12350 Research Parkway Orlando, FL 32826-3276
PRF-STRI-00416
N61339-01-D-0715/0001 3 February 2009
PRF-PT-00519
Sol. # 900KK-09-R-0002 18 June 2009 i
REVISION LOG
| Date |
| Version |
| Author |
| Section |
| Revision Description |
Table of Contents
| 1.0 SCOPE. | 1 |
| 1.1 Background. | 1 |
| 1.2 Goal. | 1 |
| 2.0 APPLICABLE DOCUMENTS. | 2 |
| 2.1 Government Specifications and Publications. | 2 |
| 2.2 Other Publications. | 3 |
| 3.0 REQUIREMENTS. | 4 |
| 3.1 General System Requirements. | 4 |
| 3.1.1 Integrated Management System. | 5 |
| 3.1.2 Targetry. | 5 |
| 3.1.2.1 Human Type Targets (HTT). | 5 |
| 3.1.2.2 Stationary Infantry Target (SIT). | 6 |
| 3.1.3 Bullet Traps. | 6 |
| 3.1.4 Modular Facility Configurations. | 6 |
| 3.2 Specific System Requirements. | 7 |
| 3.2.1 Urban Assault Course (UAC). | 7 |
| 3.2.1.1 Station 1 – Individual & Team Trainer. | 7 |
| 3.2.1.2 Station 2 - Squad & Platoon Trainer. | 7 |
| 3.2.1.3 Station 3 - Grenadier Gunnery Trainer. | 7 |
| 3.2.1.4 Station 4- Offense/Defense Trainer. | 7 |
| 3.2.1.5 Station 5 – Underground Trainer. | 7 |
| 3.2.1.6 Universal Outlet (UO). | 7 |
| 3.2.1.7 Auxiliary Outlet. | 8 |
| 3.2.2 Shoot House (SH). | 8 |
| 3.2.2.1 Range Operations Center (ROC). | 8 |
| 3.2.2.2 After Action Review (AAR). | 10 |
| 3.2.2.3 Training Building. | 11 |
| 3.2.2.4 Basic SH Instrumentation Solution. | 12 |
| 3.2.3 Special Operations Forces (SOF) Shoot House. | 13 |
| 3.2.3.1 ROC and AAR Building Modules. | 13 |
| 3.2.3.2 Site preparation and Installation. | 13 |
| 3.2.4 Combined Arms Collective Training Facility (CACTF). | 13 |
| 3.2.4.1 Range Operations Center. | 14 |
| 3.2.4.2 Exterior Cameras. | 18 |
| 3.2.4.3 After Action Review (AAR). | 18 |
| 3.2.4.4 Training Buildings. | 19 |
| 3.2.5 Mobile MOUT (MMOUT). | 21 |
| 3.2.5.1 Range Operations Center and AAR Facility Modules. | 22 |
| 3.2.5.2 Training Modules. | 23 |
| 3.2.5.3 MMOUT Special Effects. | 24 |
| 3.2.5.4 Transportation/Shipping. | 24 |
| 3.2.6 Combat Training Center MOUT-Instrumentation System (CTC MOUT-IS). | 25 |
| 3.3 System Safety. | 25 |
| 3.3.1 Environmental Safety. | 25 |
| 3.3.2 Electrical Safety. | 25 |
| 3.3.3 Hazardous Materials. | 25 |
| 3.3.4 Personnel Safety. | 25 |
| 3.3.5 Mechanical Safety. | 26 |
| 3.3.6 Antenna Safety. | 26 |
| 3.3.7 RF Safety. | 26 |
| 3.3.8 Battery Box Design Safety. | 26 |
| 3.4 Electromagnetic Environmental Effects (E3). | 27 |
| 3.4.1 Electromagnetic Compatibility (EMC). | 27 |
| 3.4.2 Intra-system EMC. | 27 |
| 3.4.3 Inter-system EMC. | 27 |
| 3.4.4 Electromagnetic radiation hazards (EMRADHAZ). | 27 |
| 3.5 Environmental. | 28 |
| 3.6 Security. | 28 |
| 3.6.1 Information Assurance. | 28 |
| 3.6.1.1 Discretionary Security Protection. | 28 |
| 3.6.1.2 Controlled Access Protection. | 29 |
| 4.0 VERIFICATION. | 30 |
| 4.1 Inspection Conditions. | 30 |
| 4.2 Methods of Verification. | 30 |
| 4.3 Classification of Inspections. | 31 |
| 4.4 Requirements. | 31 |
| 4.4.1 General System Requirements. | 31 |
| 4.4.2 Integrated Management System. | 32 |
| 4.4.3 Targetry | 33 |
| 4.4.3.1 Human Type Targets (HTT). | 33 |
| 4.4.3.2 Stationary Infantry Target (SIT) | 34 |
| 4.4.4 Bullet Traps | 34 |
| 4.4.5 Modular Facility Configurations | 35 |
| 4.4.6 Urban Assault Course (UAC) | 35 |
| 4.4.6.1 Station 1 – Individual & Team Trainer | 35 |
| 4.4.6.2 Station 2 – Squad & Platoon Trainer | 35 |
| 4.4.6.3 Station 3 – Grenadier gunnery Trainer | 35 |
| 4.4.6.4 Station 4 – Offense/Defense Trainer | 36 |
| 4.4.6.5 Universal Outlet (UO) | 36 |
| 4.4.6.6 Auxiliary Outlet | 36 |
| 4.4.7 Shoot House (SH) | 36 |
| 4.4.7.1 Range Operations Center (ROC) | 36 |
| 4.4.7.2 Exercise Control | 37 |
| 4.4.7.3 Audio Input System (AIS) | 38 |
| 4.4.7.4 Symbology | 38 |
| 4.4.7.5 Modeling | 38 |
| 4.4.7.6 Interior Lighting Control | 38 |
| 4.4.7.7 Video Monitoring and Recording System | 39 |
| 4.4.7.8 After Action Review (AAR) | 40 |
| 4.4.7.9 Training Buildings | 42 |
| 4.4.7.10 Basic SH Instrumentation Solution | 44 |
| 4.4.7.11 Special Operations Forces (SOF) Shoot House. | 45 |
| 4.4.8 Combined Arms Collective Training Facility (CACTF). | 46 |
| 4.4.8.1 Range Operations Center (ROC). | 47 |
| 4.4.8.2 Lighting Control | 52 |
| 4.4.8.3 Video Monitoring and Recording System | 52 |
| 4.4.8.4 External Interfaces | 53 |
| 4.4.8.5 Exterior Cameras | 55 |
| 4.4.8.6 After Action Review (AAR) | 55 |
| 4.4.8.7 Training Buildings | 57 |
| 4.4.9 Mobile MOUT (MMOUT) | 60 |
| 4.4.9.1 Range Operations Center and AAR Facility Modules. | 60 |
| 4.4.9.2 Training Modules | 62 |
| 4.4.9.3 MMOUT Special Effects | 64 |
| 4.4.9.4 Transportation/Shipping | 64 |
| 4.4.10 Combat Training Center MOUT-Instrumentation System (CTC MOUT-IS). | 65 |
| 4.4.11 System Safety. | 65 |
| 4.4.11.1 Environmental Safety | 65 |
| 4.4.11.2 Electrical Safety | 65 |
| 4.4.11.3 Hazardous Materials. | 66 |
| 4.4.11.4 Personnel Safety | 66 |
| 4.4.11.5 Mechanical Safety. | 67 |
| 4.4.11.6 Antenna Safety | 67 |
| 4.4.11.7 RF Safety | 68 |
| 4.4.11.8 Battery Box Design Safety | 68 |
| 4.4.12 Electromagnetic Environment Effects (E3). | 68 |
| 4.4.12.1 Electromagnetic Compatibility (EMC) | 69 |
| 4.4.12.2 Intra-system EMC | 69 |
| 4.4.12.3 Inter-system EMC | 69 |
| 4.4.12.4 Electromagnetic Radiation Hazards (EMRADHAZ). | 70 |
| 4.4.13 Environmental | 70 |
| 4.4.14 Security | 71 |
| 4.4.14.1 Information Assurance | 71 |
| 4.4.14.2 Controlled Access Protection | 73 |
Performance Specification for Urban Operations Training Systems
SCOPE.
This document establishes and defines the performance specifications for Urban Operations Training Systems (UOTS). UOTS for this effort include the following sites and types of efforts:
a. Integrated Military Operations on Urbanized Terrain (MOUT) Training Systems (IMTS)
i. Combined Arms Collective Training Facility (CACTF)
ii. Shoot House (SH)
iii. Urban Assault House (UAC)
b. Mobile MOUT
c. Combat Training Center MOUT-Instrumentation Systems (CTC MOUT-IS)
d. UOTS Site Upgrades and Technology Refresh
e. Integration with other DOD Systems (Live, Virtual, Constructive (LVC); Tactical Systems; Command, Control, Communications, Computers, & Intelligence (C4I))
f. Other MOUT, Urban Operations Training Systems, enhancements, updates, upgrades and changes required for Urban Operations Training
This covers all Army, Army Reserve, National Guard, and DOD sites located both CONUS and OCONUS. This includes all Foreign Military Sales (FMS), sales to other countries and to qualified federal, state and municipal agencies. This provides the support necessary for Corps of Engineers Reviews (Charrettes, Design, and Inspections), UOTS Information Assurance, UOTS Engineering, and UOTS Logistics.
Background.
There has been a shortage of training systems for MOUT exercises. The UOTS programs will provide multiple systems for small unit training up to Brigade and provide numerous locations and scenarios for training.
Goal.
The intent of UOTS is to provide urban training solutions which fulfill various aspects of individual, collective, and combined arms training requirements. UOTS also addresses other-than-war operations (such as peacekeeping missions), homeland defense and anti-terrorism scenarios. UOTS also includes MOUT efforts associated with the Global War On Terrorism (GWOT).
UOTS supports both fixed permanent and non-permanent structure facilities and allows for the addition or expansion to existing facilities and the integration across sites and mission domains (Live, Virtual, and Constructive).
UOTS will immerse the training participants into the realism of the event. UOTS environment must allow and support flexibility and changing scenarios to prevent learned responses vice learning benefit. Finally, UOTS must include unexpected events for the training audience.
APPLICABLE DOCUMENTS.
In the event of a conflict between documents referenced herein and the contents of this Performance Specification, the contents of the Performance Specification shall be the governing requirement.
Government Specifications and Publications.
29 CFR 1910 Occupational Safety and Health Standards
AR 25-2 Army Information Assurance
DoD 8500.2 Information Assurance (IA) Implementation
FIPS-PUB-140-2 Security Requirements for Cryptographic Modules
FM 3-06 Urban Operations
FM 3-06.11 Combined Arms Operations in Urban Terrain
FM 3-07 Stability Operations
Disronline.disa.mil DoD Information Technology Standards Registry
MIL-STD-461F Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment
MIL-STD-810G Environmental Engineering Considerations and Laboratory Tests
MIL-STD-1425A Safety Design Requirements for Military Lasers and Associated Support Equipment
MIL-STD-1474D(1) Noise Limits
MIL-STD-2525B(2) Common Warfighting Symbology
PMT 90-S002 MILES Communication Code (MCC) Standard
PRF-PT-00468 Performance Specification for the Future Army System of Integrated Targets (FASIT)
| PRF-PT-0476A | Family of Live Training Instrumented Player Units | |
| Performance Specification (IPUPS) |
PRF-PT-00498 Exportable Training Capability - Instrumentation System
(ETC-IS)
CTIA-TS-0006 Common Training Instrumentation Architecture (CTIA) Product Line Architecture Framework
CTIA-TS-0002 Common Training Instrumentation Architecture (CTIA) Product Line Architecture Specification
TC 25-8 Training Ranges
TC 90-1 Training for Urban Operations Other Publications.
ANSI/NFPA 70 National Electrical Code
ANSI Z535.3:2007 Criteria for Safety Symbols
ANSI Z535.4:2007 Product Safety Sign and Labels
CEHNC 1110-1-23 U.S. Army Corps of Engineers Design Guide for the Sustainable Range Program
CSC-STD-001-83 Rainbow Series Orange Book. DoD Trusted Computer System Evaluation Criteria
CSC-STD-003-85 Rainbow Series Light Yellow Book. Guidance for Applying the DoD Trusted Computer System Evaluation Criteria in Specific Environments
CSC-STD-004-85 Rainbow Series Yellow Book II. Computer Security Requirements
NCSC-TG-003 Rainbow Series Orange Book. A Guide to Understanding Discretionary Access Control (DAC) In Trusted Systems.
NCSC-TG-006 Rainbow Series Orange Book. A Guide to Understanding Configuration Management (CM) In Trusted Systems
NCSC-TG-007 Rainbow Series Burgundy Book. A Guide to Understanding Design Documentation in Trusted Systems
NCSC-TG-009 Rainbow Series Venice Blue Book. Computer Security Subsystem Interpretation of the Trusted Computer System Evaluation Criteria
NCSC-TG-011 Rainbow Series Red Book. Trusted Network Interpretation Environments Guideline - Guidance for Applying the Trusted Network Interpretation
NFPA 780 Installation of Lightning Protection Systems
REQUIREMENTS.
Throughout this document a threshold requirement parameter is designated by (T) and an objective requirement parameter is designated by (O). The system shall not use USB data storage devices in any facility discussed herein. No classified material shall be utilized on any system discussed herein unless the system has been accredited.
General System Requirements.
The UOTS, subsystems, and all components shall have the following basic capabilities:
a. All installed electrical infrastructure shall be in compliance with the latest version of ANSI/NFPA 70 unless otherwise directed.
b. All instrumentation shall be grounded IAW the requirements defined in ANSI/NFPA 70.
c. All ROC/AAR instrumentation shall be protected from lightning IAW the requirements defined in NFPA 780.
d. All conduit, raceway, boxes, cabinets, cabling and components shall be in accordance with ANSI/NFPA 70 unless otherwise directed.
e. All instrumentation shall be fitted with surge protection to protect devices and control equipment.
f. Uninterrupted Power Supply (UPS). The instrumentation system shall continue to operate for a minimum of fifteen minutes after a main power failure. The instrumentation shall also be protected from potentially dangerous voltage spikes/transient voltage coming in on the commercial AC power and from low line voltage (brownout). Additionally, the instrumentation shall be protected from total line power failure by providing instant emergency power to preserve data and process until an orderly shutdown can take place, or an emergency generator is activated.
g. The instrumentation control system shall be capable of being powered on and fully operational within 15 minutes (T). This capability shall be achieved with one action (e.g. a button, keyboard short-cut, etc.)(O).
h. The instrumentation control system shall be capable of being powered down (controlled shutdown) within 15 minutes (T). This capability shall be achieved with one action (e.g. a button, keyboard short-cut, etc.)(O).
i. Shall be mission capable 24 hours a day, seven days a week during the conduct of the exercise.
j. System shall be capable of providing After Action Reviews (AAR) within five minutes of end of exercise.
k. System Operational Availability (Ao) for training shall be a minimum of 95%.
l. All computer workstations shall require a Common Access Card (CAC) and Personal Identification Number (PIN) in order to access the system.
m. System software shall include a Built-In Test (BIT) and diagnostic capability identifying faults to the Line Replaceable Unit (LRU). Fault history shall be retained in a separate file for trend analysis.
Integrated Management System.
The UOTS design shall heavily utilize commercial products. This system shall minimize any proprietary-developed software or hardware and conform to the CTIA development environment. The design shall provide:
a. An open architecture.
b. For the use of IPv6.
c. For the use of Windows Vista Operating System (OS).
d. Built-In-Test and status reporting for all internal subsystems.
e. Displays that use industry standard approaches for operator interfaces.
f. Operator error messages in plain English and shall include the nature of the error, the complete method to correct it (may be accessed through a Help interface), and the name of the packages/object that generated the message.
g. Context-sensitive help to the field level.
h. Displays that are integrated through menus, icons, buttons, and other GUI devices.
i. The capability to overlap/layer information and data entry/control displays without the corruption or loss of data items.
j. A constant display of Security Classification, date, and time.
Targetry.
The system shall allow for the connection and control of a variety of targetry through the network (CACTF and SH only). UAC targets are stand alone simple reactive targets. All targets that interface with the Control System shall be designed with the Future Army System of Integrated Targets (FASIT) standards, identified in the FASIT Performance Specification document (PRF-PT-00468). Operating power for targets is 240 VAC. Target power connector shall be compatible with NEMA L14-20R. Data connector shall be male CAT6 RJ45 Ethernet or better.
Human Type Targets (HTT).
The targets shall be programmable to determine the number of mortal and/or non-mortal hits to kill. Due to the ability to determine a mortal versus non-mortal hit, these targets are referred to as precision targets. HTTs shall also be programmable to utilize Multiple Integrated Laser Engagement System (MILES) or non MILES. The targets shall report all event data back to the control software through the Universal Outlets (UO). Three dimensional full body human targets shall have the following attributes:
a. Ability to manually raise target
b. Collapsible (lower) target upon mortal hit or from the control workstation
c. Two-way audio communication through Target (O)
d. MILES hit sensing
e. MILES shoot back (CACTF and SH only)
f. Hit detection (mortal/non-mortal zone identification)
g. Live fire hit sensing (SH only) for the following munitions: 5.56mm Ball, Special Effects Small Arms Marking System (SESAM), Short Range Training Ammunition (SRTA)
h. Constructed from non ricocheting & reparable materials
i. Two types of targets – one with non-bending legs and one that collapses realistically Stationary Infantry Target (SIT).
The SITs shall be programmable to determine the number of hits to kill. The version used at the UAC (station 3 only) does not determine a mortal versus non-mortal hit; these targets are referred to as non-precision targets. SITs shall also be programmable to utilize MILES or non MILES. The targets shall report all event data back to the control system through the network. The SITs shall have the following attributes:
a. Ability to raise target from the control station
b. Collapse or lower target upon mortal hit or from the workstation
c. MILES hit sensing
d. MILES shoot back (CACTF and SH only)
e. Hit detection (mortal vs. non-mortal @ CACTF only)
f. Live fire hit sensing (UAC only) for the following munitions: 5.56mm Ball, SESAM, SRTA, 40mm Target Practice (TP)
g. Constructed from non ricocheting materials
h. Shall be available with pop-up and swing-out mechanisms Bullet Traps.
The bullet traps to be delivered shall be of a type and source that was tested and accepted IAW the detailed test plan for the SH Bullet Trap Technologies Program to be published late FY09 by the U.S. Army Developmental Test Command and U.S. Army Environmental Command.
Modular Facility Configurations.
Modular ROC/AAR/training structures may be required in future facilities. Structures shall meet requirements of their specific system as well as those specified in paragraph 3.2.5.1.
Specific System Requirements.
Urban Assault Course (UAC).
0. Station 1 – Individual & Team Trainer.
Contractor shall provide six stand-alone HTTs for Station 1. HTTs shall utilize hit detection and MILES hit sensing. UOs will be the source of power for HTTs.
Station 2 - Squad & Platoon Trainer.
Contractor shall provide ten stand-alone HTTs for Station 2. HTTs shall utilize hit detection and MILES hit sensing. UOs will be the source of power for HTTs.
Station 3 - Grenadier Gunnery Trainer.
Contractor shall provide four non-precision façade SITs and six precision SITs for Station 3. A ruggedized laptop control system capable of being mounted in a Government Furnished Equipment (GFE) pedestal shall be provided. The GFE observation control pedestal is a NEMA 4 modular console system that houses the surge protectors for the data cables. The GFE pedestal provides a 120VAC duplex receptacle and is terminated on an Ethernet CAT 6 or better RJ45 data connection for the target control system. The laptop control system shall control all Station 3 targets and record number of direct and indirect target hits. Indirect hits include rounds that go through the façade openings but do not hit the target. SITs shall be capable of connecting to UOs. The source of power for the SITs is the GFE NEMA L14-20R installed at each target location.
Station 4- Offense/Defense Trainer.
Contractor shall provide ten stand-alone HTTs. HTTs shall utilize hit detection and MILES hit sensing. UOs will be the source of power for HTTs.
Station 5 – Underground Trainer.
No instrumentation required for Station 5.
Universal Outlet (UO).
Universal Outlets are provided as GFE to provide data transfer back to the control system. Power available at the UO is 240VAC. Data available at the UO is CAT 6 terminated at a weatherproof connector (Amphenol RJF 21G with weatherproof cap RJFC2G).
UOs shall be capable of facilitating connection to networked camera boxes, networked speaker boxes, targetry, etc. The control system must be capable of recognizing any device (with pre-programmed interface descriptions) connected to the UO through the appropriate interface device without further intervention and provide for control of the device from the control system operator's screen. (Station 3 Only) Auxiliary Outlet.
The source of power for other MOUT Special Effects (ref. para. 3.2.4.4.7), is the NEMA L5-20R. Auxiliary Outlets are GFE for Stations 1, 2, 3 and 4. Power available at the Auxiliary Outlet is 120VAC.
Shoot House (SH).
0. Range Operations Center (ROC).
The ROC shall be comprised of the hardware and software necessary to conduct shoot house exercises. The ROC shall consist of one or more workstations that are capable of executing all UOTS control and presentation software. All workstations shall be provided with consoles, desks, chairs, stands and other furniture as may be required to operate the equipment. The control system shall provide:
a. The operator interface for monitoring and controlling the building instrumentation.
b. The capability to control all associated functions from one control station utilizing a fully integrated approach.
c. The routing of audio and video to the operators' monitors.
d. A configurable graphical user interface for use in controlling the instrumentation.
e. A primary server for hosting the control system database and logging of exercise data. All data storage and software [to include the Operating System (OS)] shall be on removable media.
f. The workstation(s) shall have the capability to create and read commonly available removable media (e.g. CD-R, CD-RW, DVD-RW). The system shall not utilize USB memory devices.
g. Back-up and archival of data.
h. Ability to automatically recognize, control, and communicate with system peripherals (i.e. targetry, MOUT Special Effects, audio/video collection devices, etc.).
i. Provide for the capability to execute and record exercises autonomously up to five hours without requiring use of an operator.
Exercise Control.
Exercise Control shall provide for the following capabilities:
a. Support playback of events and time-synchronized audio and video data for review, analysis, and comment insertion.
b. Provide for preplanned scenarios in the training buildings.
c. Provide for ability to activate devices either manually or during preplanned scenario generation.
Audio Input System (AIS).
The AIS shall record the verbal, gunfire and other ambient audio of the exercise associated with a video source. The AIS shall provide clearly audible verbal exchanges within the SH.
Symbology.
The situation awareness screens shall use symbology or icons to display targets and other plug and play devices. The library shall consist of MIL-STD-2525B(2) type symbology and its descriptors. The symbology shall not obscure the graphics on which it is overlaid. Therefore, display management techniques shall be employed to de-clutter the screen presentation.
Modeling.
The situation awareness screens shall provide a two dimensional display of the interior of the instrumented training building. At a minimum the display shall show the locations of cameras, universal outlets, speakers, targets and the equipment room.
Interior Lighting Control.
Interior lighting shall be controlled from any control system operator screen at the ROC. The control system shall be capable of turning the lights on or off within the training building. The status of the lights shall be indicated on the control system operator screen. Infrastructure lighting will be provided by Military Construction, Army (MCA).
Video Monitoring and Recording System All cameras in the training buildings shall be capable of being monitored and digitally recorded under both day and low illumination conditions from the control room at the ROC. Any illumination devices used to capture video under low illumination shall not cause night vision optical devices to white out (T) and be undetectable by the exercise participant (O) in the training building.
Video Monitoring The training building video and associated audio shall be monitored using the control workstation(s) and control room speakers. The control software shall allow the operator to define a set of interior cameras into logical settings. The control software shall display a selectable quantity of video feeds from a single camera feed to twelve or more audio/video (A/V) feeds simultaneously. During operation, when the predefined group is selected, all video sources for these cameras shall be displayed onto the control workstation monitor.
Video Recording The operator workstation(s) shall be capable of bookmarking events during an exercise. A visual cue shall indicate that a video image(s) is recording and an additional cue shall indicate that a video image(s) has been bookmarked. The digitally recorded and bookmarked video along with their associated audio shall be stored, cataloged and searchable in a selection list for later retrieval during the AAR and Take Home Package (THP) editing and preparation process. The system shall provide a minimum of five continuous hours of recording for each connected camera.
ROC Infrastructure.
Three GFE NEMA L14-30R outlets will be provided to energize the instrumentation equipment racks. Power provided is 240VAC, 30 amps. Data pathways between the control/equipment room and AAR theatre will be provided in the ROC as part of GFE.
After Action Review (AAR).
The AAR component shall provide applications and equipment to select, edit, manage and display recorded/bookmarked A/V footage and presentations. Recorded/bookmarked A/V footage shall be capable of being dragged and dropped or copied into an AAR play list for use during the AAR. Software accessing the A/V database shall have Standard Query Language (SQL) capability. Any media captured, created or user provided shall have the capability to be inserted into the AAR and THP, projected on the AAR theatre screen, archived to a DVD and purged (upon command) from the system. The system shall be capable of routing all of the following input signals, as a minimum, to the AAR projector, speakers and preview monitors:
a. Operator Workstation(s)
b. User Provided Laptop (AAR laptop wall-plate interface)
c. AAR Theatre Presenter Camera
d. AAR Theatre Audience Camera
e. Microphone
f. Projector
g. CD/DVD
h. Presentation Software
i. Video/Audio Playlist
The AAR presenter shall be capable of controlling the presentation from the podium area in the AAR theatre (e.g. play, stop, pause, next slide, last slide, etc.).
AAR Presentation Capture A video and audio recording capability, consisting of cameras and microphones, shall be provided in the theatre to record two simultaneous views of the area surrounding the podium and theatre seating. This capability shall be used to record an AAR as it occurs and provide the resulting footage as part of a THP. AAR audio and video shall be recorded as one asset. Control and monitoring of the AAR cameras and microphones shall be facilitated from the ROC control room.
Take Home Package (THP).
The system shall be capable of utilizing any video/audio captured during the exercise and the AAR, as well as, any presentation media to create a THP for the training unit. The THP will organize the training video/audio and AAR into logical units for ease of use during playback at the home station. To create and edit the THP the system shall be capable of utilizing:
a. Input of video and audio from analog or digital sources.
b. Software that supports insert edits, voice-overs, three-point edits, and video/audio overlays.
AAR Infrastructure.
One double power outlet will be provided as GFE to energize the control workstation. Power provided is 120VAC, 20 amps.
Training Building.
Instrumentation includes equipment necessary to activate all universal outlets, camera and sound boxes, targets, panic buttons, lighting controls and sound effects.
Networked Camera Boxes.
Camera boxes shall connect to the UOs to send digital data across the network to the ROC. The camera box equipment shall be protected from the effects of surrounding environmental conditions. Camera boxes shall include any required camera, illuminator, and microphone necessary to satisfy the requirements. Power available at the UO is 240VAC via a NEMA L5-20R. There shall be an adequate number of camera boxes to provide 100% coverage of the training area in the SH. Per section 3.2.2.1.6 there are additional low illumination requirements.
Speaker System.
The speakers shall be used to deliver control operator messages, battlefield sound effects, automatic emergency messages, and other audio media. All operator stations shall have full access and control of audio and sound effects. The speaker system shall be connected and controlled through the UOs. Power available at the UO is 240VAC via a NEMA L5-20R.
Panic Buttons.
Multiple panic button switches shall be installed for activation by personnel in the SH and one at the operator work station in the ROC. The number of panic buttons to be installed shall be determined by the size and layout of the instrumented building. Standard SH designs require eight panic buttons. The panic button shall alert the personnel in the SH to immediately halt training and the control system operator that an emergency exists. When a panic button is activated, the following actions shall occur:
a. The controlled lighting in the SH shall turn on.
b. An audible message calling for a cease fire shall be broadcast through the complex speakers.
c. A flashing panic button icon appears on the operators' screens at the location of alarm.
d. The cameras and video storage systems will continue to operate when a panic button is activated.
The panic button shall require a manual reset at the switch that was activated. The panic button assembly shall be completely sealed against moisture and dust. It shall operate Single Pull Double Throw (SPDT) contacts with a “pull on” – “push off” action. The panic button shall be red in color.
Universal Outlet (UO).
Universal Outlets are provided as Government Furnished Equipment (GFE) to provide data transfer back to the ROC. Power available at the UO is 240VAC. Data available at the UO is CAT 6 terminated at a weatherproof connector (Amphenol RJF 21G with weatherproof cap RJFC2G).
UOs shall be capable of facilitating connection to networked camera boxes, networked speaker boxes, targetry, battlefield effects devices, smoke generator controllers, smell generator controllers, application driven devices, etc. The control system must be capable of recognizing any device (with pre-programmed interface descriptions) connected to the UO through the appropriate interface device without further intervention and provide for control of the device from the control system operator's screen.
Data infrastructure shall be installed for cameras mounted on the ceiling of the SH training building and terminated in the equipment room. Power outlets on the ceiling are provided as GFE.
Auxiliary Outlet.
The source of power for other MOUT Special Effects (ref. para. 3.2.4.4.7), is the NEMA L5-20R. Auxiliary Outlets are GFE for the SH. Power available at the Auxiliary Outlet is 120VAC.
Targetry Each SH installation shall have ten HTTs and three spares.
Bullet Traps Each HTT fielded to a SH shall have a bullet trap located behind it.
Equipment Room.
A single duplex NEMA 5-20 will be provided as GFE to energize the instrumentation equipment panel. Adequate spare circuit breakers will be provided as GFE for a full instrumentation of cameras. Full infrastructure (power, copper, and fiber) will be terminated on a standard NEMA 12 (2’W x 3’H x 10”D) wall mounted data enclosure provided as GFE. Four-inch diameter conduit access for power and data to cameras will be provided as GFE from the equipment room. Twelve-strand single mode fiber optic cable will be provided as GFE to connect the ROC to the equipment room.
Basic SH Instrumentation Solution.
The Basic SH Instrumentation Solution shall have similar requirements compared to the SH instrumentation package, in terms of being able to record, playback an exercise and providing MOUT Special Effects (ref. para. 3.2.4.4.7). However, its solution shall not require a control workstation, therefore, eliminating the need of an operator at the workstation. The basic SH solution shall provide a simple “on” control mechanism at the entrance and a simple “off” control mechanism at the exit of the SH training building, that can issue the start and stop of the recording of an exercise. Once the exercise is complete and/or the “off” switch is activated, then all recorded data shall be transferred to a digital storage area where it may be copied onto a removable media as needed (e.g. CD-R, CD-RW, DVD-RW). No editing capabilities of recorded video clips will be required. In addition, the capabilities shall include the functionality to simultaneously record and copy data onto a removable media (i.e. an exercise can be recorded, while the data from a previous exercise can be copied onto a removable media at the same time.).
Special Operations Forces (SOF) Shoot House.
The SOF SH shall have the same capabilities described in Shoot House requirements paragraph 3.2.2 except for the following:
a. No HTTs
b. A minimum of ten bullet traps shall be provided
c. No UOs are provided as GFE
d. A modular ROC/AAR is required (not GFE)
e. Camera boxes are required for 100% of rooms and stairwells. Quantity of rooms, floors and stairwells may vary from site to site.
0. ROC and AAR Building Modules.
The modular ROC and AAR Facilities International Standards Organization (ISO) containers shall provide:
a. Weather tight modular containers available in multiple configurations
b. Interior climate controls - heat and air conditioning
c. Interior seating to accommodate 15 in a single container; 30 in a double container
d. Interior lighting
e. Acoustically treated and insulated walls and ceilings
f. Connections to training building GFE data fiber (minimum 24 strand single mode)
g. Connections to training building GFE power
h. Physical security (lockable doors)
i. All containers and assembled structures from the containers shall be installed such that they can withstand sustained winds up to and including those with 70 mph velocity.
j. HVAC required to operate under specified environmental conditions listed in paragraph 3.5.
Site preparation and Installation.
The ISO containers shall be capable of installation/erection on graded level soil (compacted if necessary). Containers shall be capable of being installed on a flat, prepared surface without sinking into the ground.
Combined Arms Collective Training Facility (CACTF).
The CACTF and SH shall have similar architectures.
0. Range Operations Center.
The ROC shall be comprised of the hardware and software necessary to conduct Urban Operations exercises. The ROC shall consist of one or more workstations that are capable of executing all UOTS control software. All workstations shall be provided with consoles, desks, chairs, stands and other furniture as may be required to operate the equipment. The control system shall provide:
a. The operator interface for monitoring and controlling the training building instrumentation.
b. The capability to control all associated functions from one control station utilizing a fully integrated approach.
c. The routing of audio and video to the operators' monitors.
d. A configurable graphical user interface for use in controlling the instrumentation.
e. Automatic activation of training devices when desired.
f. The capability to create and read commonly available removable media (e.g. CD-R, CD-RW, DVD-RW) where appropriate. The system will not utilize USB memory devices.
g. Digital mapping information shall provide the fidelity equal to or greater than that of the paper based maps used by the exercise units and/or compatible with digital maps organic to unit tactical ABCS systems. The digital mapping information shall support National Geospatial-Intelligence Agency (NGA) Digital Terrain Elevation Data (DTED) levels 1-2,), Geospatial Intelligence Feature Data (GIFD), Digital Features Analysis Data (DFAD), Vector Map (VMap), Compressed Arc Digitized Raster Graphics (CADRG), and Compact Terrain Data Base (CTDB). Details include, but are not limited to: Universal Transverse Mercator (UTM) grid lines, contour lines, manmade features, vegetation, water, elevation, roads, and trails. The required digital map scales are 1:50,000, 1:25,000, 1:5,000 and 1:1,000. Digital over-flight maps are 1:50,000 and 1:25,000 scale. UOTS shall have the capability to incorporate rapidly generated digital terrain data in support of mission planning/rehearsal activities.
h. Back-up and archival of data.
i. Ability to automatically recognize, control, and communicate with system peripherals [i.e. targetry, MOUT Special Effects (ref. para. 3.2.4.4.7), audio/video collection devices, etc.].
j. ROCs with two or more workstations shall be capable of controlling and recording ongoing operations while presenting an AAR.
k. Provide for the capability to execute and record exercises autonomously up to five hours without requiring use of an operator.
Exercise Control.
Exercise Control shall provide for the following capabilities:
a. Provide a zoom and scaling feature. Map scaling (zoom) shall not require exiting the display. Zooming shall be continuous for vector graphics and as a step function for raster graphics. Zooming shall be provided in fixed multipliers of existing scale. Scaling shall be provided relative to standard map scale representations (1:1000, 1:25,000). Current scale shall be constantly displayed on the map window.
b. Provide a capability to open multiple Situational Awareness Windows (SAW) from an active window.
c. Provide map-centering functions through operator-entered coordinates or through “mouse” action.
d. Allow navigating the window (“fly over”) through keyboard arrow keys or “mouse” action.
e. Allow scrolling of the map through "mouse" action ("click and drag"). Dragging the pointer to any window edge shall continue the scrolling in the same direction as the edge chosen.
f. Allow a current view to be saved and viewed as a named file. SAW files shall retain all capabilities and the operator can replay from that point.
g. Support multi-colored maps and displays.
h. Support use of color shading to display difference in terrain elevation.
i. Provide adjustable scaling of the elevation component in 3D views.
j. Display continuous sight range of view and designations.
k. Use filters to control display and interaction with data.
l. Enable replay functions without limiting current exercise activities.
m. Support playback of events and time-synchronized audio and video data for review, analysis, and comment insertion.
n. Provide for preplanned scenarios in the training buildings.
o. Provide for ability to activate devices either manually or during preplanned scenarios.
Audio Input System (AIS).
The CACTF AIS shall record the ambient audio (including clear verbal exchanges) of the exercise associated with a video source. As the video of each camera is selected for viewing, the audio shall automatically follow with the associated camera view. The system shall have the capability of selecting which audio stream is heard in the ROC.
Symbology.
The situation awareness screens shall use symbology or icons to display individual players, military units, targets, MOUT Special Effects (ref. para. 3.2.4.4.7), and other plug and play devices. The library shall consist of MIL-STD-2525B(2) type symbology and its descriptors. The symbology shall not obscure the graphics on which it is overlaid. Therefore, display management techniques shall be employed to de-clutter the screen presentation.
Modeling.
The UOTS shall provide two and three dimensional displays of the interior of the instrumented buildings and the exterior site layout to support entity tracking.
Situational Awareness Window (SAW).
The SAW shall provide a window into the exercise area that shows the relative position of entities, devices, tactical overlays, and other graphics accurately overlaid through a common coordinate system on two or three dimensional maps or representations of the terrain. The control system shall support multiple SAWs either tiled or cascaded.
Exercise Awareness.
The SAW shall:
a. Depict real or simulated player events and status in near real-time.
b. Reflect real and simulated player position.
c. System shall be capable of displaying a group as a single icon.
d. Support displaying a player by entering or selecting the player ID. The map display shall pan to display the player in the current window.
e. Provide history trails upon operator request. History trails shall be selected based on start time, end time, and duration of the track. History trails shall be selectable by individual player, by group, or for all players
f. Toggle or displace overlapping symbols with position lines to preclude loss of information presentation to the operator.
g. Reflect status changes through intuitively identifiable changes to the player symbology.
h. System shall be capable of displaying patterns or otherwise color Area Weapon Effects (AWE) to indicate area and suppression zone, if applicable, and the type of AWE engagement.
i. Display AWE with sufficient resolution on map displays to accurately convey location and boundaries. When map scales are such that area weapon effect depiction is scaled too small to be obvious, other indicators of the effect shall be provided.
j. Display non-persistent effects with sufficient duration to allow an operator to react to their presence.
k. Display information on AWE through pop-up displays.
l. Select icons and symbology on map displays through "mouse click" or keyboard action (e.g., tabbing through all icons) to change the focus for subsequent status displays, command actions, etc.
m. Focus automatically on the latest displayed event except when overridden by mouse or keyboard action.
n. Bring up a context sensitive menu when focus is placed on real and simulated player icons, simulation events, exclusion areas, and AWEs.
o. At or after creation, any settings shall be modifiable. Each SAW shall retain its own properties (e.g. scale, overlays, filters, etc.).
p. A new SAW shall inherit all settings from the SAW from which it was created.
Entity Tracking.
The UOTS shall provide the capability to track the position/location (i.e. X, Y and Z axis) of various desired entities throughout the maneuver/training area. The tracking system shall provide accurate and seamless tracking while entities are in either indoor or outdoor conditions. The tracking system shall provide position reports up to one update per second per entity being tracked. Accuracy of tracking shall depict all entities in their correct room or hallway within one meter (T) and objectively within six inches (O). The tracking system shall be capable of monitoring up to 200 entities in the maneuver area. The tracking system shall not interfere with the maneuvers or actions of a dismounted troop, nor impact the form or function of a tracked object.
Lighting Control.
Interior lighting in each room being instrumented shall be controlled from any control system operator screen. The control system shall be capable of turning the lights on or off within each training building module or globally in all instrumented buildings and exterior lighting. The status of the light shall be indicated on the control system operator screen. Interior and exterior lighting will be provided by MCA.
Video Monitoring and Recording System All cameras in the training building shall be capable of being monitored and digitally recorded under both day and low illumination conditions from the control room at the ROC. Any illumination devices used to capture video at night shall not cause night vision optical devices to white out (T) and be undetectable by the exercise participant (O) in the training buildings.
Video Monitoring The training building video and associated audio shall be monitored using the control workstation(s) and control room speakers. The control software shall allow the operator to define a set of interior cameras into logical settings. The control software shall display a selectable quantity of video feeds from a single camera feed to twelve or more audio/video (A/V) feeds simultaneously. During operation, when the predefined group is selected, all video sources for these cameras shall be displayed onto the control workstation monitor.
Video Recording The operator workstation(s) shall be capable of bookmarking events during an exercise. A visual cue shall indicate that a video image(s) is recording and an additional cue shall indicate that a video image(s) has been bookmarked. The digitally recorded and bookmarked video along with their associated audio shall be stored, cataloged and searchable in a selection list for later retrieval during the AAR and Take Home Package (THP) editing and preparation process. The system shall provide a minimum of five continuous hours of recording for each connected camera.
External Interfaces.
The system shall provide for interoperability with the Common Training Instrumentation Architecture (CTIA) and other common architectures.
Distributed Simulation Administration.
The UOTS Control System shall provide an application compliant with the DoD Information Technology Standards Registry specifications to interface to external High Level Architecture (HLA) and Distributed Interactive Simulation (DIS) compliant simulations. The application shall:
a. Monitor the interface performance
b. Control the operation of the interface
c. Control embedded DIS/HLA simulations
d. Provide security services
e. Execute the Run Time Interface (RTI)
f. Provide tools for briefing, integrating and testing HLA compliant federates and federations
g. Coordinate terrain databases using the Synthetic Environment Data Representation and Interchange Specification (SEDRIS).
h. Provide DIS reporting rate transformations
i. Provide the capability to filter Protocol Data Units External Systems.
The UOTS Control System shall interface with systems such as the:
a. Common Training Instrumentation Architecture (CTIA) (T)
b. Combat Training Center Objective-Instrumentation System (CTC-OIS) (T)
c. Future Combat Systems (FCS) (O)
d. Homestation Instrumentation Training System (HITS) (O)
e. Tactical Engagement Simulation System (TESS) (O)
f. Exportable Training Capability-Instrumentation System (ETC–IS) (O) ROC Infrastructure.
Two GFE 60A circuit breakers will be provided to energize the instrumentation equipment racks. Power provided is 120/240VAC. Data pathways between the control/equipment room and AAR theatre will be provided in the ROC as part of GFE.
Exterior Cameras.
Exterior cameras shall provide for color views during daylight hours and clear intelligible images during low illumination conditions. Cameras shall have pan, tilt, zoom, and focus capabilities that can be controlled from the ROC by the operator. Exterior cameras shall be capable of operating under natural environmental conditions. Exterior cameras shall connect to the closest network connection to send digital data across the network to the ROC. Power available at the exterior camera location is 240VAC.
After Action Review (AAR).
The AAR component shall provide applications and equipment to select, edit, manage and display recorded/bookmarked A/V footage and presentations. Recorded/bookmarked A/V footage shall be capable of being dragged and dropped or copied into an AAR play list for use during the AAR. Software accessing the A/V database shall have Standard Query Language (SQL) capability. Any media captured, created or user provided shall have the capability to be inserted into the AAR and THP, projected on the AAR theatre screen, archived to a DVD and purged (upon command) from the system. The system shall be capable of routing all of the following input signals, at a minimum, to the AAR projector, speakers and preview monitors:
a. All Operator Workstations
b. User Provided Laptop (AAR laptop wall-plate interface)
c. AAR Theatre Presenter Camera
d. AAR Theatre Audience Camera
e. Microphone
f. Projector
g. CD/DVD
h. Presentation Software
i. Video/Audio Playlist
The AAR presenter shall be capable of controlling the presentation from the podium area in the AAR theatre (e.g. play, stop, pause, next slide, last slide, etc.).
AAR Presentation Capture A video and audio recording capability, consisting of cameras and microphones, shall be provided in the theatre to record two simultaneous views of the area surrounding the podium and theatre seating. This capability shall be used to record an AAR as it occurs and provide the resulting footage as part of a THP. AAR audio and video shall be recorded as one asset. Control and monitoring of the AAR cameras and microphones shall be facilitated from the ROC control room.
Take Home Package (THP).
The system shall be capable of utilizing any video/audio captured during the exercise and the AAR, as well as, any presentation media to create a THP for the training unit. The THP will organize the training video/audio and AAR into logical units for ease of use during playback at the home station. To create and edit the THP the system shall be capable of utilizing:
a. Input of video and audio from analog or digital sources.
b. Software that supports insert edits, voice-overs, three-point edits, and video/audio overlays.
AAR Infrastructure.
One quadruplex power outlet will be provided as GFE to energize the data rack. A duplex will be provided as GFE for each control workstation. Power provided is 120VAC, 20 amps.
Training Buildings.
The contractor shall instrument 80% of the training buildings. Instrumentation includes equipment necessary to activate all universal outlets, camera and sound boxes, targets, panic buttons, lighting controls, and MOUT effects (ref. para. 3.2.4.4.7).
Interior Camera Boxes.
Camera boxes shall connect to the UOs to send digital data across the network to the ROC. Camera boxes shall be capable of being easily relocated to another UO. The camera box equipment shall be protected from the effects of surrounding environmental conditions to include SRTA rounds. Camera boxes shall include any required camera, illuminator, and microphone necessary to satisfy the requirements. Power available at the UO is 240VAC via a NEMA L5-20R. There shall be an adequate number of camera mounts to cover 100% of the camera UOs. There shall be enough camera boxes to provide 64% coverage of the provided camera mounts. See section 3.2.4.1.7 above for additional low illumination requirements.
Speaker System.
The speakers shall be located within each building to provide 100% audio coverage to all instrumented buildings. The speakers shall be used to deliver control operator messages, battlefield sound effects, automatic emergency messages, and other audio media. The speaker system shall be zoned by area, floor, building, or all-call giving the operator the ability to deliver audio to specific zones independently. All operator stations shall have full access to all audio zones at all times, thus allowing all operators to deliver sound effects or page to different zones simultaneously. The speaker system shall be connected and controlled through the UOs.
Panic Buttons.
A panic button switch shall be installed for activation by personnel in each instrumented building and the operator work station at the ROC.
This is the start of the file's text. The full file is on GovTribe.
Other files
| File | Type | Posted |
|---|---|---|
| 7. UOTS DRAFT Perf Spec.doc.docx | DOCX document | |
| 8. UOTS DRAFT PWS.doc.docx | DOCX document | |
| 5. Industry Day Brf 29 June09.pptx.ppt | PPT presentation | |
| 6. UOTS Industry Day Atendees 29 June.doc.docm | DOCM document | |
| 3. UO SOW | — |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .