Exhibit_C_Data_Item_A003.pdf

PDF 459 KB Posted

Attached to
Solicitation Amendment For the Overhaul/Upgrade of the UH-60 Power Turbine
Solicitation number
W58RGZ-19-R-0081
Issued by

About this file

This Contract Data Requirements List outlines technical reporting requirements for the overhaul, repair, upgrade, modification, or recapitalization of UH-60 power turbine modules. The contractor must submit an initial process plan to the U.S. Army Research, Development and Engineering Command for informational purposes only. For any subsequent changes affecting critical characteristics, the contractor must submit a revised plan within 30 days of the change for government review and approval. The contractor shall provide documentation electronically in PDF format on CD-ROM. Distribution of the documentation is limited to U.S. government agencies for test and evaluation purposes.

Exhibit C_Data Item A003.pdf

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT DATA REQUIREMENTS LIST

(1 Data Item)

03/14/2017Page 1 of 2

2840-01-5031700

POWER TURBINE MODULE

D. SYSTEM / ITEM

A003

1. DATA ITEM NO.

WESSON, JEREMIAH

G. PREPARED BY

12/28/2016

H. DATE

WESSON, JEREMIAH

I. APPROVED BY

12/28/2016

J. DATE

MAYHALL, CONNIE

LOG #

CONCUR:

A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY

DATE: 01/17/2017

4. AUTHORITY (DATA ACQUISITION DOC NO.) 5. CONTRACT REFERENCE

2. TITLE OF DATA ITEM

6. REQUIRING OFFICE

3. SUBTITLE

F. CONTRACTORE. CONTRACTOR / PR NO.

7. DD 250 REQ 9. DIST STATEMENT

REQUIRED

10. FREQUENCY 12. DATE OF FIRST

SUBMISSION

14. DISTRIBUTION

8. APP CODE

b. COPIES

DRAFT FINAL

REG REPRO

a. ADDRESSEE 11. AS OF DATE 13. DATE OF SUBEQUENT

SUBMISSION

15. TOTAL

17. PRICE GROUP 18. ESTIMATED TOTAL PRICE

RDMR-SEU

NSN

PRID: PART NUMBER:KT318 6071T26G02 STATUS: R

AMSRD-AMR-SE-TD-ST/DM

Technical Report - Study/Services Process Plan

DI-MISC-80508B SOW, PARA T RDMR-SEU

LT

A

B SEE BLK 16

N/A

30DAC

SEE BLK 16

0 1 0

0 1 0

16. REMARKS:

BLOCKS 8, 10 & 13: When the contractor makes a change to the plan (as frozen at the time the PVA is approved by the Government or, when a PVA is not required, prior to induction of the first overhaul, repair, upgrade, modification or recapitalization asset) that affects a critical characteristic, submit copy of the revised plan to the Government, for review and comments, within 30 days after the date of the change. As required, revised the plan based on the Government's review and comments and resubmit to the government within 30 days of Government's comments.

BLOCK 9: Distribution Statement B: Distribution authorized to U.S. Government agencies only;

test and evaluation; date of determination: 7 July, 2005. Other requests for this documentation shall be referred to Commander, U.S. Army Research, Development and Engineering Command, ATTN: RDMR-SEU, Redstone Arsenal, AL 35898-5000.

Export Control Act Warning - Not required

BLOCK 12: The first submission of the overhaul, repair, upgrade, modification, or recapitalization plan will be used by the Government for informational purposes only.

BLOCK 14: Documentation shall be provided electronically in adobe acrobat .pdf or compatible format on compact disk read only memory device (cd-rom).

DISTRIBUTION

a. Complete packages sent to: Commander, U.S. Army Research, Development and Engineering Command, ATTN: RDMR-SEU, Redstone Arsenal, AL 35898-5000.

b. Letter of transmittal only sent to procurement Contracting Officer as specified in contract.

POC: PHONE:

W58RGZ-17-R-0160

Exhibit C

03/14/2017Page 2 of 2

W58RGZ-17-R-0160

Exhibit C

File details come from the government source that posted it. Updated .