MAINTENANCE ENGINEERING ORDER
(AMCOM Reg 750-2)
MEO NO.
DATE PAGE 1 of
TITLE Tolerances
Unless otherwise noted, dimensions are in inches and tolerances are:
Fractional………..…….+/- 1/32 Decimal……….………..+/- .010 Angular…………+/- ½ degrees
APPLICABILITY
INTERIM USE OF THIS MEO IS AUTHORIZED UNTIL
AFFECTED DOCUMENT IS UPDATED.
CSI Critical Characteristic Affected?
Impact Statement Attached:
REFERENCES FOR RDECOM USE ONLY
DOCUMENT(S) AFFECTED
DOCUMENT CHANGE IS REQUIRED
PURPOSE OR PROBLEM
PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE
PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT CHANGE OR
REVISION TO THE PUBLICATION IDENTIFIED ABOVE.
WP
NO.
PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGE MUST BE GIVEN)
MED FORM 15-DEC-09 1401-R-E
C7123 Jun 2, 2011 1
Power Supply PN 60-3782-5
NO
✔ YES
DMWR 1-6130-296 dated 24 Jan 2007
UH-60EE DAA
TN 97019
Tech data correction
Dinh Luu Jerry Forsythe Ron Walterick
3-2 3-9.e.
and 3-9.i.
Change to read:
"If lamp voltage is value calculated in step b. within +/-1 volt and flashes are 60-80 fpm, go to next step. If not, discontinue testing and overhaul power supply".
RDMR-AEM
MEMORANDUM FOR RECORD:
SUBJECT: Impact of AED Maintenance Engineering Order (MEO) on maintenance using , dated , affecting system:
1. Enclosed MEO will be issued by this office and is provided as part of our Technical Data user support mission. This MEO may impact maintenance contracts or repair parts acquisition decisions.
2. OVERALL IMPACT:
3. CLASSIFICATION:
New / Revised Procedure / Process Illustrated Parts Breakdown (IPB) Change
Technical Requirement Clarification Repairable Bill of Materials (RBOM) Impact
Suggestion Study / Test Results Critical Safety Item (CSI) Review
Parts Marking Implementation / Update Environmental Review
MEO Review (Chg. / Rev. Driven) Other
4. CRITICAL CHARACTERISTIC(S) AFFECTED:
Dimension / Tolerance Finish / Material Process / Procedure None
5. READINESS IMPACT:
Testing Required Special Tooling Special Process
Part / Material Logistics Impact Inspection(s) Required None
6. MATERIAL IMPACT:
More Less None Unknown Cost / Usage
Labor / Processing Parts / Materials Affected:
7. COMMENTS:
8. Point of contact for this action is
DMWR 1-6130-296
C7123
C7123
24 Jan 2007 UH-60
No Significant Airworthiness Impact-Implement per standard procedures
Tech data correction
Dinh Luu, dinh.luu@us.army.mil; phone (361) 961-3353
File details come from the government source that posted it. Updated .