Q&As_w56hzv-18-r-0073.pdf
PDF 51 KB Posted
- Solicitation number
- W56HZV-18-R-0073
About this file
This document contains questions and answers regarding Solicitation Number W56HZV-18-R-0073 from the U.S. Army Contracting Command Warren. The solicitation seeks a firm fixed price contract to provide six DrySide tanker fire trucks and operator and maintenance training to the Jordan Armed Forces. The training must take place on a continental United States basis. Specifications for the fire trucks have been amended to allow for a 50 gallon standard fuel tank, steel cab construction if aluminum is unavailable, and correction of the water tank capacity to 2,600 US gallons. Overseas training in Jordan would not meet the terms of the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TIQ_-_Dry_Side_Tanker_Fire_Truck_-_Amendment_1.doc | DOC document | |
| Spec_-_Dry_Side_Tanker_Fire_Truck_-_Amendment_1.docx | DOCX document | |
| W56HZV18R0073-0005_signed.pdf | ||
| W56HZV18R0073-0004_signed.pdf | ||
| W56HZV-18-R-0073_0003.pdf | ||
| W56HZV18R0073-0002_signed.pdf | ||
| W56hzv-18-r-0073_0001.pdf | ||
| Dryside_Fire_Trucks_Sol.pdf | ||
| TIQ_-_Dry_Side_Tanker_Fire_Truck.doc | DOC document | |
| Attachment_0001_-_Spec_-_Dry_Side_Tanker_Fire_Truck.docx | DOCX document | |
| Dryside_Fire_Trucks_Sol.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Q&As for W56HZV-18-R-0073:
1- single or double tyre required
It's up to the Offeror, but it has to be a 6x6 configuration, and the tire arrangement has to handle the loading of the vehicle at GVW AND meet the performance requirements.
2- single or double cabin required
Single
2.5 – What is blackout lighting?
Bidder will have to look this up.
6.6 – standard size fuel tank on commercial chassis is 50 gallon, will that be acceptable?
Yes, Spec & TIQ have been amended to accommodate this request.
10.7 – What is a NATO slave start connector?
Bidder will have to look this up.
13.1 – What is Chemical Agent Resisting Coating? Is the commercial chassis standard red paint acceptable of should body builder repaint cab?
Bidder will have to look this up. Standard paint is NOT acceptable.
14.1 – would a steel cab be acceptable if aluminum is not available?
Yes, Spec has been amended to accommodate this request.
Spec; item 7.2. Can the integrated T-Case requirement can be removed?
Yes, Spec has been amended to accommodate this request.
“Maintenance Training to support the vehicles. Travel and Living Allowances shall be provided by the contractor to provide Continental United States (CONUS) Training for the Operator and Maintenance Training”
The vehicle we would offer would be manufactured overseas and it would be cost effective to have the training completed in the final destination of Jordan. Can you advise if this is possible to offer this solution.
The LOA is written to have the training performed CONUS. Therefore, OCONUS is not allowed/acceptable.
It shows The vehicle shall have a 2,600 gallon (2,271 liter) water tank 2600 US gallons would equal 9842 litres and not 2271 as listed.
Yes, Spec has been amended.
Please confirm.
File details come from the government source that posted it. Updated .