08 AUGUST 2016

LAMS SOLICITATION

SECOND SET

RESPONSES TO SOLICITATION W56HZV-16-R-0011

LARGE AREA MAINTENANCE SHELTERS (LAMS)

*** NOTE THE FOLLOWING QUESTION WAS INACCURATELY ANSWERED ON

THE 02 AUGUST 2016 Q&A POSTING ***

QUESTION 6:

MIL-PRF-32504B - 3.1.5.1 Shelter Fabric Specifications

a) Can you explain what is desired for the Top Coat Composition as a “High Performance Film, 0.0001 inch min, dull finish”? Do you mean 0.001 inch (1 mil) thick? Is this to be a separate film laminated to the fabric, a liquid top finish or ???

REVISED 08 AUGUST 2016

ANSWER 6: The Top Coat film thickness is to have a dry film thickness of 0.0001" minimum over the fabric face coat. The purpose is as a protective coating and sealer. The coating application technique is not specified as manufacturing processes are constantly evolving. If a material meets the fabric specifications through testing it will be considered. MIL-PRF-32504B is corrected back to state 0.0001 inch.

NEW QUESTION:

QUESTION 1:

Do the “near new” ISO containers mentioned in the RFQ need to be of domestic origin, or are foreign containers are allowed?

ANSWER 1:

Please refer to the following clauses in the solicitation:

1. 252.225-7001 Buy American and Balance of Payments Program – Basic

2. 252.225-7002 Qualifying Country Sources as Subcontractors

3. 252.225-7012 Preference for Certain Domestic Commodities