This purchase description outlines requirements for two cubicle-style emergency safety showers. Key details include that the showers must meet OSHA, NFPA, ASTM, ANSI, NEMA, and EIA standards. Each shower should be approximately 43 inches wide, 38 inches deep, and 94 inches tall with a single overhead spray, integral drain, and eyewash bowl. Additional requirements specify item unique identification registration, utilities available, new and unused equipment, safety and environmental compliance, and minimum one-year service and support capabilities. The related federal contract opportunity is solicitation number W519TC-23-R-2067 from the Department of the Army Materiel Command Contracting Command Rock Island Arsenal for hazardous material safety showers. The deadline to respond has not been provided.

View the file

Other files for this federal contract opportunity

Other files attached to HAZMAT SAFETY SHOWER and AMENDMENT 0001, newest first.
File Type Posted
W519TC-23-R-2067 Amendment 0001.pdf PDF
W519TC-23-R-2067.pdf PDF
Attachment 0001 - RIPD E4000-23-9-50.pdf PDF
Attachment 0002 - CDRL.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROCK ISLAND ARSENAL RIPD: E4000-23-9-50

PURCHASE DESCRIPTION DATE: 06-SEPTEMBER-23

SAFETY SHOWERS

1. GENERAL SYSTEM DESCRIPTION

2. STANDARDS AND PUBLICATIONS

2.1 Clarification

2.2 National Standards and Specifications

3. DESIGN

3.1 Ownership

3.2 General Design Standards

3.3 Safety, Security and Environmental

4. COMPONENT SPECIFICATION

4.1 Features:

5. APPROVAL/SHIPPING

5.1 Shipping

5.2 Installation

5.3 Completion

6. SERVICE

6.1 Service/Support Requirements

1. GENERAL SYSTEM DESCRIPTION

This statement of work is to purchase two cubicle style Emergency Safety Showers. Each shower will have a single overhead spray and integral drain, plus the accessories listed in the component specification section. The Emergency Safety Showers will be delivered by the vendor in accordance with the following requirements. The Hughes STD-SD-32K-PUMP is the suggested source of supply.

2. STANDARDS AND PUBLICATIONS

2.1 Clarification

Any ambiguities, questions, requests for clarification or discrepancies between sections of this purchase description, drawings, national or industry standards discovered by the contractor in reviewing this purchase description shall be reported by the bidder in writing to the contracting officer BEFORE THE DATE SCHEDULED FOR CLOSE OF BIDDING/receipt of proposal.

Submission of a proposal or bid shall be construed as evidence that such examination has been made. Therefore, later claims for labor, material, or equipment required, or for difficulties encountered, which could have been foreseen had such reasonable examination been made, may be denied.

2.2 National Standards and Specifications

The following specifications in effect on the Date of Invitation for Bid/Request for Proposal form a part of this purchase description. In the case of conflicting requirements, the more stringent shall apply.

2.2.1 Occupational Safety and Health Act of 1970 (OSHA).

2.2.2 American Society of Testing and Materials (ASTM).

2.2.3 American National Standards Institute (ANSI).

2.2.4 National Electrical Manufacturers Association Standards (NEMA).

2.2.5 Electronic Industries Association (EIA).

2.2.6 National Fire Protection Association (NFPA).

2.2.6.1 NFPA-70 National Electrical Code

2.2.6.2 NFPA-79 Electrical Standard for Industrial Machinery.

3. DESIGN

3.1 Ownership

3.1.1 This equipment is a standard product of the manufacturer and shall require either no change or minor design changes to meet requirements of these specifications. Therefore, ownership of the design will remain with the manufacturer.

3.2 General Design Standards

3.2.1 ID DATA PLATE: The equipment shall include a main data plate which will include the following data as a minimum requirement (additional information is acceptable):

Manufacturer Name, Manufacturer’s Dunns and Bradstreet Number, Manufacturer’s Model

Number, Manufacturer’s Serial Number, Year of Manufacture, Contract Number, Machine

Weight. This information is necessary for compliance with the governments Unique

Identification Program (UID).

3.2.2 DATA PLATES: All instruction, data, and identification plates and labels attached to this equipment and its controls shall be manufactured of corrosion and oil resistant metal or plastic material. All wording shall be in the English language using plain, bold face lettering.

Lettering shall be permanent and have a contrasting background.

3.2.3 ITEM UNIQUE IDENTIFICATION (IUID) REGISTRATION: The contractor shall register the equipment in the IUID Registry (as one single system). IUID registration requires the contractor to input Cage Code, Model Number, and Serial Number into a Government

Database to allow for asset and inventory tracking. IUID Registry of the equipment shall be performed at http://dodprocurementtoolbox.com/site/uidregistry/. Training for IUID is available in https://wawftraining.eb.mil. IUID registration of this equipment is required prior to final payment in the Wide Area Work Flow (WAWF). The contractor shall also affix a machine readable 2-dimensional (2-D) matrix representing the IUID registry to the machine. The IUID

2-D matrix may be included on the ID Data Plate outlined in paragraph 3.2.4.

3.2.4 UTILITIES AVAILABLE: Rock Island Arsenal shall be responsible for providing the following:

3.2.4.1 Connection of 460-V, 60-Hz, 3-Ph AC electrical power to the fused or breaker type disconnect switch required in the ELECTRICAL DISCONNECT paragraph of this purchase description. Connection does not include filters, surge protection, or any peripheral equipment necessary to make the equipment functional.

3.2.4.2 Connection of approximately 65-psi water to a single point for each system, if needed. Connection does not include filters or any peripheral equipment necessary to make the equipment functional. If water is required, the contractor shall be responsible for installing a back-flow limiting device sufficient to prevent possible contamination of the water system. This is necessary to maintain IEPA compliance.

3.2.5 NEW EQUIPMENT: The equipment furnished under this purchase description shall be new and unused.

3.2.6 PAINTING: All unfinished surfaces of the equipment shall be painted with a lead free and chromium free commercial grade of metal primer and a minimum of one finish coat. The color shall be in accordance with the manufacturer’s standard commercial practice, or as necessary to maintain compliance with OSHA regulations, as applicable.

3.3 Safety, Security and Environmental

3.3.1 INDUSTRY AND REGULATIONS: The equipment shall comply with the most current of all local, state, and federal laws and regulations listed in Standards and Publications.

3.3.2 MATERIAL EXCLUSIONS: The equipment shall not contain polychlorinated biphenyl

(PCB), ozone depleting substances (Class I or Class II), or asbestos materials.

http://dodprocurementtoolbox.com/site/uidregistry/ https://wawftraining.eb.mil/

4. COMPONENT SPECIFICATION

The contractor shall be responsible for supplying all components, tools, and labor necessary to assemble, deliver, and test two Safety Showers to the Rock Island Arsenal as described below. The cubicle shower should have a stainless-steel hollow section frame enclosed in GRP sheeting. The sheeting will be fitted with pictogram signs to International Standard ISO 3864-1 with green and white safety stripes. The shower will have stainless steel pipework. A covered eyewash bowl will be located under the shower rose. The Rock Island Arsenal will install the equipment. This equipment shall be a Hughes STD-SD-32K45G-PUMP brand or equivalent per these details.

4.1 Features:

4.1.1 SIZE: 43+/-10.0 inches wide by 38+/-3.0 inches of depth by 94+/-3.0 inches of height.

4.1.2 SERVICE INLET: 1.0-inch Male NPT.

4.1.3 WATER OUTLET: Integral drain sump with wastewater discharge pump.

4.1.4 ACTIVATION/OPERATION: Shower – Pull Handle and Eye Wash – Pull Lid Down.

4.1.5 EYEWASH: Covered bowl eyewash located under the shower.

4.1.6 SHOWER HEAD: Removable self-draining ABS shower rose.

4.1.7 STYLE OF SHOWER: Indoor Safety Cubicle Shower.

5. APPROVAL/SHIPPING

5.1 Shipping

5.1.1 RESPONSIBILITY: The contractor is responsible for delivery of the equipment to the

Rock Island Arsenal. Adequate preserving of equipment surfaces, packing, marking, and skidding of materials for shipment shall be the responsibility of the contractor. If special lifting devices, such as hooks or eyes, are required for ease of handling, they shall be supplied with the equipment. Any special devices shall be returned to the contractor upon request only if they will not be required for future movement of the equipment, and at the contractor’s expense.

5.1.2 SHIPPING SCHEDULE: Be aware, the Rock Island Arsenal will only off-load equipment arriving between 6:00 am and 12:00 am (noon), local time on Mondays through

Thursdays except holidays. For information concerning holidays, the contractor should consult the contracting officer. There is no place to stage transporting vehicles awaiting the arrival of contractors. All equipment shall be delivered at the same time, meaning the same day (multiple trucks are acceptable) unless pre-authorized to deliver on multiple days by the RIA-JMTC contracting officer.

5.1.3 RECEIVER: All shipments to Rock Island Arsenal including installation tools and/or replacement parts, as well as the original shipment of the equipment, shall be marked “ATTN:

Mr. Robert Mcclure or Mr. Dave Holgorsen TARA-LGC”. Items not correctly marked are subject to being returned at the vendor’s expense.

5.1.4 ARRIVAL INSPECTION: Upon receipt of equipment at Rock Island Arsenal, a preliminary inspection shall be performed to determine condition and/or count. This inspection shall be performed by Rock Island Arsenal personnel.

5.2 Installation

5.2.1 PREPARATION EXECUTION SUPPORT: Rock Island Arsenal will perform the installation of the purchased equipment.

5.3 Completion

5.3.1 Final acceptance of the equipment shall occur after the following:

5.3.1.1 Successful completion of performance testing at Rock Island Arsenal.

5.3.1.2 Complete documentation packages are delivered.

6. SERVICE

6.1 Service/Support Requirements

The contractor shall have as a minimum, a verifiable service/repair capability which meets or exceeds the following requirements:

6.1.1 STAFF: Staffed by qualified, English speaking personnel fully knowledgeable in the service/repair of the equipment offered.

6.1.2 TELEPHONE ACCESS: Telephone access to service/repair personnel shall be available for consultation during Rock Island Arsenal normal working hours. Rock Island

Arsenal normal working hours are 8:00 am CST to 3:00 pm CST, Monday through Friday, except legal federal holidays.

6.1.3 ON-SITE RESPONSE: Physical, on-site response shall be possible within 48-hrs of notification that service/repair of the equipment is necessary.

6.1.4 MAINTENANCE PARTS: Parts necessary for periodic replacement such as belts, hoses, filters, and other parts normally considered as spare parts, by the manufacturer, shall be stocked and available for shipment.

6.1.5 PRIOR HISTORY: Said service/repair capability shall have been available to the general public prior to the issue date of this purchase description. Adequate proof of prior availability shall be provided upon request.

File details come from the government source that posted it. Updated .