This document is a technical specifications attachment for a lifted platform to be installed at a designated Air National Guard Base warehouse facility. The platform must conform to precise dimensional parameters with a footprint of 22.00 ± 2 feet (length) by 18.00 ± 2 feet (width), an overall deck height of 125.25 inches, and clear under-clearance of 108.00 inches for main beams and 111.00 inches minimum for deck beams. The platform shall be a single-level open-deck configuration designed to support a uniform live load capacity of 125 pounds per square foot, a concentrated load capacity of 2,000 pounds for pallet jack loads, and a maximum column load of 300 PSI, with seismic design required for site-specific seismic zones.
The structural materials specified include 4-inch by 4-inch square structural steel tubing columns (ASTM A500 Grade B, 3/16-inch wall thickness) with 8-inch by 8-inch by 1/2-inch thick welded baseplates designed for 6-inch unreinforced 3,500 PSI concrete, American Standard Channel main beams (C15 x 33.9, 18.00 feet length) and deck beams (C12 x 20.7, 22.00 feet length) conforming to ASTM A6-79b, and 20-gauge corrugated B-deck with grate, bar, or expanded flooring to permit sprinkler suppression. Access, safety, and egress requirements include minimum 68 linear feet of gray double-rail safety handrails with integrated kickplates, one vertical safety access ladder conforming to OSHA standards, two double-rail drop-safety gates with adjustable openings of 49 to 72 inches, and all steel structural members must receive an industrial finish.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1: SALIENT CHARACTERISTICS (TECHNICAL SPECIFICATIONS)
1.1 Dimensional & Performance Specifications
To fit within the physical constraints of the designated Air National Guard Base warehouse facility, the lifted platform must conform to the following exact dimensional and performance parameters (or industry-standard equivalents):
Characteristic Specification / Requirement
Footprint Size 22.00 +- 2 ft (Length) x 18.00 +-2 ft (Width)
Column Center-to-Center
21.30 ft (Length) x 17.30 ft (Width) Minimum opening of 9’ +- 12’’ between columns
+Overall Deck Height 125.25 inches (10 ft 5.25 in)
Clear Under-Clearance (Main Beams)
108.00 inches (9 ft 0 in) +- 6’’
Clear Under-Clearance (Deck Beams)
111.00 inches minimum (9 ft 3 in)
Levels Single-level (1) with open-deck configuration
Uniform Live Load Capacity 125 PSF (pounds per square foot)
Concentrated Load Capacity 2,000 lbs (Live/Dead Pallet Jack Load)
Maximum Column Load 300 PSI
Seismic Design Yes (Designed for site-specific seismic zone)
1.2 Material & Component Specifications
• Columns: 4 in x 4 in x 0.19 in (3/16 in wall thickness) square structural steel tubing (Fy = 46 ksi conforming to ASTM A500 Grade B), predrilled for structural attachments.
• Baseplates: 8 in x 8 in x 0.50 in (1/2 in thick) square steel plates, welded to columns, provided with four (4) predrilled bolt holes for floor anchoring on an assumed 6-inch unreinforced 3,500 PSI concrete base slab.
• Main Beams: American Standard Channel (C15 x 33.9), length 18.00 ft conforming to ASTM A6-79b.
• Deck Beams: American Standard Channel (C12 x 20.7), length 22.00 ft conforming to ASTM A6-79b.
• Deck Support Centers: Maximum 41.5 inches center-to-center spacing.
• Lower Deck Surface: 20-gauge corrugated B-deck painted with a reflective white underside to maximize illumination in the active workspace beneath the platform.
NONE
• Top Flooring Surface: Grate, bar or expanded flooring , open to allow sprinkler suppression below
• Fasteners: As required
• System Finish: All steel structural members must have an industrial finish.
1.3 Access, Safety, & Egress Accessories
• Safety Handrails & Kickplates: Minimum of 68 linear feet of gray, double-rail safety handrail conforming to OSHA and building code standards, including integrated kickplates (toe guards).
• Vertical Safety Ladder: One (1) steel vertical safety access ladder, 125.25 inches in height, conforming to OSHA standards.
• Drop Safety Gates: Two (2) double-rail drop-safety gates with adjustable openings of 49 to 72 inches +-12’’ (FSDG4972 or equal).