This is a Technical Specifications document for a lifted warehouse platform to be installed at a designated Air National Guard Base facility.

The platform must be a single-level structure with specific dimensional parameters: 22.00 ±2 feet (length) by 18.00 ±2 feet (width) footprint, overall deck height of 125.25 inches, and clear under-clearance of 108.00 inches at main beams and 111.00 inches minimum at deck beams. The structure must support a uniform live load capacity of 125 PSF and concentrated loads of 2,000 pounds for pallet jack operations, with a maximum column load of 300 PSI. The platform must be seismically designed for site-specific seismic zones and accommodate column center-to-center spacing of 21.30 by 17.30 feet with a minimum opening of 9 feet ±12 inches between columns.

Material requirements specify 4-inch by 4-inch square structural steel tubing columns (ASTM A500 Grade B) with 8-inch by 8-inch baseplates, American Standard Channel main beams (C15 x 33.9) at 18 feet length, and deck beams (C12 x 20.7) at 22 feet length, all conforming to ASTM A6-79b standards. The deck surface shall consist of 20-gauge corrugated B-deck with reflective white underside and grate or expanded flooring on top to allow sprinkler suppression. Safety and access features include a minimum of 68 linear feet of gray double-rail safety handrails with integrated kickplates, one vertical steel safety ladder at 125.25 inches height, and two double-rail drop-safety gates with adjustable openings of 49 to 72 inches ±12 inches, all conforming to OSHA and building code standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 1: SALIENT CHARACTERISTICS (TECHNICAL SPECIFICATIONS)

1.1 Dimensional & Performance Specifications

To fit within the physical constraints of the designated Air National Guard Base warehouse facility, the lifted platform must conform to the following exact dimensional and performance parameters (or industry-standard equivalents):

Characteristic Specification / Requirement

Footprint Size 22.00 +- 2 ft (Length) x 18.00 +-2 ft (Width)

Column Center-to-Center

21.30 ft (Length) x 17.30 ft (Width) Minimum opening of 9’ +- 12’’ between columns

+Overall Deck Height 125.25 inches (10 ft 5.25 in)

Clear Under-Clearance (Main Beams)

108.00 inches (9 ft 0 in) +- 6’’

Clear Under-Clearance (Deck Beams)

111.00 inches minimum (9 ft 3 in)

Levels Single-level (1) with open-deck configuration

Uniform Live Load Capacity 125 PSF (pounds per square foot)

Concentrated Load Capacity 2,000 lbs (Live/Dead Pallet Jack Load)

Maximum Column Load 300 PSI

Seismic Design Yes (Designed for site-specific seismic zone)

1.2 Material & Component Specifications

• Columns: 4 in x 4 in x 0.19 in (3/16 in wall thickness) square structural steel tubing (Fy = 46 ksi conforming to ASTM A500 Grade B), predrilled for structural attachments.

• Baseplates: 8 in x 8 in x 0.50 in (1/2 in thick) square steel plates, welded to columns, provided with four (4) predrilled bolt holes for floor anchoring on an assumed 6-inch unreinforced 3,500 PSI concrete base slab.

• Main Beams: American Standard Channel (C15 x 33.9), length 18.00 ft conforming to ASTM A6-79b.

• Deck Beams: American Standard Channel (C12 x 20.7), length 22.00 ft conforming to ASTM A6-79b.

• Deck Support Centers: Maximum 41.5 inches center-to-center spacing.

• Lower Deck Surface: 20-gauge corrugated B-deck painted with a reflective white underside to maximize illumination in the active workspace beneath the platform.

• Top Flooring Surface: Grate, bar or expanded flooring , open to allow sprinkler suppression below

• Fasteners: As required

• System Finish: All steel structural members must have an industrial finish.

1.3 Access, Safety, & Egress Accessories

• Safety Handrails & Kickplates: Minimum of 68 linear feet of gray, double-rail safety handrail conforming to OSHA and building code standards, including integrated kickplates (toe guards).

• Vertical Safety Ladder: One (1) steel vertical safety access ladder, 125.25 inches in height, conforming to OSHA standards.

• Drop Safety Gates: Two (2) double-rail drop-safety gates with adjustable openings of 49 to 72 inches +-12’’ (FSDG4972 or equal).