RFI_s Answered-Telephone Service.pdf

PDF 1 MB Posted

Attached to
Local Telephone Services Federal contract opportunity
Solicitation number
W50S8Z-25-Q-0010
Issued by
Department of the Army Oregon Army National Guard

About this file

This appears to be a placeholder PDF document that displays an Adobe Reader upgrade message rather than the actual content of the intended document. The image shows standard Adobe Reader messaging indicating that the PDF viewer may need to be upgraded to properly display the document's contents, with links provided to download the latest version of Adobe Reader for Windows, Mac, or Linux operating systems.

Based on the metadata provided, this file is associated with a Sources Sought notice (W50S8Z-25-Q-0010) from the Department of the Army Oregon Army National Guard seeking Local Telephone Services. The requirement involves replacing existing LSTDM circuits with emulated SIP circuits for telecommunications services at the 173d Fighter Wing. Responses are due by 1:00 PM PDT on February 27, 2025, and should be submitted to the listed contracting specialists. The NAICS code is 517111 with a 1500-employee size standard. The government is considering small business set-aside options and requires contractors to provide past performance examples of similar telecommunications infrastructure projects.

View the file

Other files for this federal contract opportunity

Other files attached to Local Telephone Services, newest first.
File Type Posted
Sources Sought Form- LTS.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Please wait...

If this message is not eventually replaced by the proper contents of the document, your PDF viewer may not be able to display this type of document.

You can upgrade to the latest version of Adobe Reader for Windows®, Mac, or Linux® by visiting http://www.adobe.com/go/reader_download.

For more assistance with Adobe Reader visit http://www.adobe.com/go/acrreader.

Windows is either a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries. Mac is a trademark of Apple Inc., registered in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries.

Request for Information Worksheet Page of RFIW, v1.0 Requirement Information Requirement Description Solicitation Number Contracting Officer Questions and Answers Number Question Answer Increase Rows Decrease Rows

Notes General Notes and Information 2.1 817-852-3254 02 June 2015

136 MSG/MSC

Micah Kruse Contract Execution Checklist 03 June 2015 All DID’s need E911 compatibility.

IP’s will not be provided and a new circuit is required.

Currently one, we want to expand that to two.

Connection Wizards.

210 Arnold Ave, Klamath Falls, OR 97603, Building 210, room 112

AVAYA CM7

Our equipment does not currently support SIP and will require a TDM to SIP conversion.

Call hold -Yes Call transfer (unattended and attended ) -Yes Call Conference -Yes Call forward (all, busy, no answer) -Yes Calling Line (number) Identification Presentation (CLIP) -Yes Calling Line (number) Identification Restriction (CLIR) -Yes DTMF relay (both directions) (RFC2833) Y-es Media flow-through on Cisco UBE -No Fax (G711 passthrough) -Yes No, redundancy isn’t required.

(541)880-0600-0999, (541)880-2440-2539, (541)885-6100-6699 Total Number of DIDs Required: 1100

Continuous services 24/7/365 with a 99.999% reliability, inform the government of scheduled outages 30 days in advance, provide an after action report for unscheduled outages within 5 days of resolution, and designated response times for the severity of the unscheduled outages.

CurrentPage:
PageCount:
PRNumber: Telephone Services
PRNumber: W50S8Z-25-Q-0010
PRNumber: Jason Rice
Cell1: 1
Cell1: Do all DIDs in Directory require E911 compatibility? Or will you separately provide DID numbers that are E911 compatible?
Cell1: 2
Cell1: Are IP addresses for SIP Trunk going to be provided, or is a new internet circuit required at Demarc?
Cell1: 3
Cell1: What capacity is required in terms of concurrent telephone calls (simultaneous incoming or outgoing calls to the public switched telephone network (PSTN)?
Cell1: 4
Cell1: LSTDM – How many Primary Rate ISDN (PRI) circuits are currently used? Typically each PRI supports 23 concurrent calls.
Cell1: 5
Cell1: What carrier provides the existing LSTDM circuits?
Cell1: 6
Cell1: Where is the demarcation point (demarc) located, i.e. Building Number, Floor, Room, street address, city, state and ZIP?
Cell1: 7
Cell1: What private branch exchange (PBX) will the SIP trunks be connected to, i.e. make (Avaya, Cisco, Nortel, etc.), Model (Aura), and Version (11.5)?
Cell1: 8
Cell1: Does existing PBX support SIP trunking? If yes, to what PBX device or edge boundary controller will the SIP trunking circuit(s) connect to? If no, will a Patton SN4170 or Oracle Acme Packet device be required to convert SIP trunking to PRI?
Cell1: 9
Cell1: What SIP trunking features are required such as:

Call hold Call transfer (unattended and attended ) Call Conference Call forward (all, busy, no answer) Calling Line (number) Identification Presentation (CLIP) Calling Line (number) Identification Restriction (CLIR) DTMF relay (both directions) (RFC2833) Media flow-through on Cisco UBE Fax (G711 passthrough)

Cell1: 10
Cell1: Will redundancy for SIP trunking circuits be required?
Cell1: 11
Cell1: How many direct inward dial numbers need to be ported? Are these numbers in consecutive number blocks such as 541-885-6000 to 541-885-6999?
Cell1: What service level agreements will be required for availability such as 99.99% uptime and 99.99% of the time call quality of at least mean opinion score of 3.5 out of 5?
:
IncreaseRowA:
DecreaseRowA:

File details come from the government source that posted it. Updated .