PREBID Conference Slides -Electric Loop FINAL.pptx
PPTX presentation 2 MB Posted
- Attached to
- 106 CE ELECTRICAL LOOP REPAIR
- Solicitation number
- W50S8E27QA001
About this file
This is a prebid conference presentation slide deck for an Air Force electrical infrastructure repair solicitation. Solicitation W50S8E27QA001, issued by the 106th Rescue Wing at Francis S. Gabreski Air National Guard Base in Westhampton Beach, New York, seeks a firm-fixed price contractor to repair a medium voltage electrical loop and connect an existing 13.8 kV feeder line to a second feed at the transformer supporting Building 395. The project objective is to eliminate a single point of failure in the electrical distribution system. The organized site visit was scheduled for Wednesday, November 4, 2026, at 10:00 AM EST at Building 345, with attendance limited to two representatives per company. Offerors were required to submit attendee names by 10:30 AM EST on Tuesday, November 3, 2026, to edwin.nunez.3@us.af.mil and conor.riley.2@us.af.mil. Requests for Information (RFIs) were due by 10:30 AM EST on Thursday, November 5, 2026, submitted to SARA_MARGARET.LUNA.1@US.AF.MIL and ANTHONY.KIRINCIC@US.AF.MIL.
The presentation outlines submission requirements including AF Form 3000 (Material Approval Submittal), AF Form 3064 (Contract Progress Schedule), AF Form 3065 (Contract Progress Report), and WAWF invoicing through the PIEE Solicitation Module. The government indicated it intends to award without discussions, corrections, or revised quotes, and warranty of construction disclaimer language (FAR 52.246-21) applies. All solicitation documents, amendments, and Q&A responses are posted on SAM.gov and the PIEE platform only. The presentation also includes administrative guidance regarding REAL ID Act compliance effective May 7, 2025, requiring all base visitors to present compliant identification or be escorted by their sponsoring unit.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Site-Visit Sign in sheet.jpg | JPG image |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CE Electric Loop Repair Solicitation #: W50S8E27QA001
106th Rescue Wing Francis S. Gabreski ANGB Westhampton Beach New York 4 Novemeber 2026 Site Visit Conference
Introductions Contract Specialists: (Solicitation #) MSgt Anthony Kirincic
Deputy Base Civil Engineer: Lt Col Conor Riley
Contracting Officer’s Representative (COR): Mr. Edwin Nunez
Base Access/EAL POC:
Lt Col Conor Riley Mr. Edwin Nunez
Synopsis Solicitation #1- Repair Electric Loop-The objective of this contract is to connect the existing line to the second feed at the transformer supporting Building 395 to eliminate the single point of failure at FS Gabreski ANGB.
A firm-fixed price contract will be awarded
Solicitation & Supporting Documents https://sam.gov/
PIEE MODULE
Solicitation –Statement of Work (SOW) –Wage Determination –Questions & Answers (RFIs) –Amendments
Check regularly & refresh webpage
Solicitation Amendments Check regularly & refresh webpage
Important Reminder The Government intends to award without a chance for discussions, corrections, or revised quotes.
Important Clauses
52.246-21 Warranty of Construction
Disclaimer The following is a brief overview of the quote requirements Offerors are strongly cautioned to carefully read the requirements of the solicitation and comply accordingly.
Submittal Process
AF3000 - MATERIAL APPROVAL SUBMITTAL
AF3064 - CONTRACT PROGRESS SCHEDULE
AF3065 - CONTRACT PROGRESS REPORT
WAWF Invoicing
PIEE Solicitation Module Web Based Training for the PIEE Solicitation Module:
https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml
Registration Instructions for the PIEE Solicitation Module: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf
DOD Procurement Toolbox: https://dodprocurementtoolbox.com/
PIEE Solicitation Module The Posting and Offer guide can be accessed electronically at: https://pieetraining.eb.mil/wbt/sol/Posting_Offer.pdf.
A video demonstration can be found at: https://pieetraining.eb.mil/wbt/sol/Posting_Offer.html.
Additional PIEE training can be found at: https://pieetraining.eb.mil/wbt/.
Answers to Questions All questions, on a non-attribution basis, and the answers will be posted ONLY at:
sam.gov & PIEE.
If necessary addendums, issued by an amendment, will also be posted ONLY at: sam.gov & PIEE Check web site regularly and don’t forget to refresh webpage
Real ID Act
Name: MSgt Joseph Pico Date: 24 January 2025 Office Symbol: S3O
Overview The REAL ID Act is a law that sets security standards for state-issued driver's licenses and identification cards. The law was passed by Congress in 2005 in response to the 9/11 Commission's recommendations.
What Does the REAL ID Act do Requires states to meet minimum security standards for driver's licenses and identification cards Prohibits federal agencies from accepting non-compliant identification cards for certain purposes Applies to accessing federal facilities, boarding commercial aircraft, and entering nuclear power plant
License Comparisons
AF Policy Starting 7 May 2025; State-issued driver’s licenses and identification cards from states not meeting the standards can no longer be used for accessing Federal facilities including Air Force installations unless the issuing state’s compliance deadline has been extended by the Department of Homeland Security (DHS).
Individuals who do not possess a driver’s license or identification card compliant with the REAL ID Act and do not possess an acceptable alternate identification credential, must be escorted or denied access
Reference:
AFMAN 31-101V3, Installation Perimeter Access Control, Section 3.2, Establishing Identify for Unescorted Access
SF Implementation All non-government ID card holders will need to be escorted by their sponsoring Unit, or they will be denied access.
Contractors Deliveries New recruits
Helpful Websites sam.gov https://piee.eb.mil/xhtml/unauth/home/login.xhtml
Site Visit Rules Safety Briefing - Important information to know before we begin our site visit.
Walk around installation Picture Taking Don’t forget your license at the Main Gate when leaving the installation
Questions?
image10.jpg image11.png image12.png image13.png image14.jpeg image15.jpeg image16.jpeg image17.jpeg image3.png image1.png image2.jpg
File details come from the government source that posted it. Updated .