W50S8A21Q0034
RFI
1.) Purity: You mention 95 to 99.5% (is there a preference?)
Answer: Purity of 95 to 99.5% is specified by the T.O
2.) Pressure: you mention 200PSI, is that at peak usage?
Answer: 220 PSI would be our peak usage
3.) Normal Gals flow rate, SCFH or SCFM: ?
Answer: Normal Gals flow rate, 2400 SCFH
4.) Flow rate: What is the peak flow requirement?
Answer: peak flow requirement are 220 PSI for 30 min
5.) Duration of peak flow: how many minutes would the peak flow rate be?
Answer: peak flow rate would be 20-30 min
6.) Location of generator: indoor or outdoor?
Answer: the generator will be located indoors
7.) Is there a hazardous area concern needing to be addressed in the design?
Answer: no hazardous area concern in the design
8.) Is this a self-contained generator or needing an air supply?
Answer: we will need an air supply
9.) If an air supply needed, do you have and what air quantity does it provide and pressure?
Answer: air supply is needed and we have 120PSI air pressure
10.) Power supply for generator and/or air supply if required (V / Hz / ph)?
Answer: We are set up for 110-240Volts/50-60Hz/1 Phase power supply and 120 PSI air supply