03_A-002 Demo Plan - B972 ADD1.pdf
PDF 951 KB Posted
- Attached to
- Demolish Bldg. 972 and Misc Site Work Selfridge ANGB Federal contract opportunity
- Solicitation number
- W50S8520B0008
About this file
This document package includes a solicitation and supporting drawings for a demolition and site work contract opportunity. The contractor shall demolish Building 972 and various other structures, roads, railroads, sidewalks and utilities at Selfridge Air National Guard Base in Michigan. Demolition includes buildings and items listed in the statement of work and information drawings. The contractor must restore the site after demolition by re-grading and establishing grass ground cover. A pre-proposal site visit is scheduled for 12 August at 10:00 am for interested contractors. The solicitation number is W50S8520B0008 and was issued by the Department of the Army Michigan Army National Guard for this demolition and site work opportunity at Selfridge ANGB.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
SHEET OF
Engineer/Consultants
Sheet Title
2 5
REVISIONS:
Project Number:
File:
Drawn By:
Designed By:
Checked By:
VGLZ 000000
Mark Date Description
PROJECT
Scale:
Date:
NOTES:
1.
NOTE: FOR INFORMATION
PURPOSES ONLY. NOT FOR DESIGN
OR CONSTRUCTION. FIELD VERIFY
DIMENSIONS PRIOR TO DESIGN
AND PRIOR TO CONSTRUCTION.
\\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\127 WG.jpg
P:\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\CE Color PATCH small.jpg
DEMOLISH BLDG. 972
& REMOVE PERIMETER
FENCE COMPLET.
REMOVE ALL
PAVEMENTS & CURBS
AS INDICATED.
SAW CUT AS NEEDED.
CAP OFF EXISTING
DOMESTIC WATER SUPPLY
LINE TO MAIN
REMOVE EXISTING
FIRE HYDRANT
REMOVE EXISTING
TRANSFORMER &
ELECTRICAL POLE
COMPLETE
CAP OFF EXISTING
SANITARY
LINE TO MAIN
DEMO
BLDG 972
Brian Durkee
H. Bauzon
VGLZ 000000
NOT TO SCALE
04 MAY 2020
REMOVE TREE COMPLETE
TO THE GROUND. CLEAR ALL
DEBRIS AND DISPOSE OF OFF SITE.
REMOVE TREES COMPLETE
TO THE GROUND. CLEAR ALL DEBRIS
AND DISPOSE OF OFF SITE.
DEMOLITION PLAN - BLDG. 972
NTS
DEMOLITION
PLAN -
BLDG. 972
A-002
LEGEND:
DEMOLISH BLDG. 972
FIRE HYDRANT
ELEC POLES
TRANSFORMER
GAS LINES
ELECTRICAL
SANITARY (OLD)
SANITARY (NEW)
STORM
WATER
LIQUID FUELS
REMOVE ALL PAVEMENTS
& CURBS AS INDICATED.
PATCH ASPHALT ROAD
REMOVE RAIL ROAD (RAILS,
TIES, AND BALLAST)
GENERAL NOTES
1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. ALL
DIMENSIONS AND CONDITIONS ARE TO BE VERIFIED IN FIELD
BY THE CONTRACTOR.
2. CONTRACTOR SHALL FIELD VERIFY UNDERGROUND UTILITIES
WITH THE UTILITIES SHOP
REMOVE TREE COMPLETE
TO THE GROUND.
STORM DRAIN
(NOMINAL DEPTH)
REMOVE FLAGPOLE TO
THE GROUND.
REMOVE EXISTING
ELECTRICAL POLE
COMPLETE
REMOVE TREE COMPLETE
TO THE GROUND. CLEAR ALL
DEBRIS AND DISPOSE OF OFF SITE.
AutoCAD SHX Text
AutoCAD SHX Text
FISH POND ROAD
AutoCAD SHX Text
JEFFERSON AVE
AutoCAD SHX Text 127th WING/CIVIL ENGINEER
AutoCAD SHX Text
SELFRIDGE AIR
AutoCAD SHX Text
NATIONAL GUARD
AutoCAD SHX Text
BASE, MICHIGAN
AutoCAD SHX Text THE PLAN AND UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE GOVERNMENT MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE GOVERNMENT FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION.
| Sheets and Views |
| Demo Plan 972 |
File details come from the government source that posted it. Updated .