This document is a solicitation for an HVAC replacement project at Building 42 on McConnell Air Force Base in Wichita, Kansas. The work involves removing three existing mini-split HVAC systems in rooms 17, 13A, and 13B, and installing a new 5-ton modulating heat pump unit. The contractor will be responsible for properly sizing the new unit. This is a small construction project being procured using Simplified Acquisition Procedures under FAR Part 13, with no bonding required. Quotes can be submitted via email. The solicitation number is W50S7X-24-Q-0015, with the Department of the Army National Guard as the procuring agency.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
McConnell AFB Wichita KS
BASE MAP
PROJECT
LOCATION
BUILDING 42
WEST GATE ENTRY
ACCESS FROM S. OLIVER AND
GEORGE WASHINGTON BLVD.
BUILDING 65
ANG SECURITY POLICE
BUILDING 35
ANG MEDICAL CLINIC
BUILDING 03
BASE CIVIL
ENGINEERING
BUILDING 51
FIRE STATION
EAST GATE ENTRY
ACCESS FROM ROCK. ROAD
BUILDING 205
BASE HOSPITAL
BUILDING 1201
BASE FIRE DEPARTMENT
BUILDING 115
BASE SECURITY POLICE
AFFF
WASTE TANK
ATSO AREA
FT
F
1 FT
F
TAXIWAY FOXTROT TAXIWAY FOXTROT
WICH
ITA
AI
R M
US
EU
M
JAYHAWK Dr.
SA
LIN
A D r.
N.
M
IN
UT
EM
AN
D r.
S.
M
IN
UT
EM
AN
D r.
PH
AN
TO
M
Av e.
PHANTOM Ave.
st
ST
RE
ET
S
OU
TH
MU
ST
AN
G
Dr
TH
UD
D r.
JAYHAWK Dr.
JAYHAWK Dr.
FALCON Dr.
JAYHAWK Dr.
SA
BR
E Dr
FALCON Dr.
FALCON Dr.
GEORGE WASH. BLVD.
GEO
RG
E W
AS
H.
BL
VD
FALCON Dr.
EM
PO
RI
A
DR
KANSAS STREET
WICHITA STREET
SO
UT
HE
AS
T G
AT
E
GATE
MAIN
PI
TT
SB
UR
G
DR
MA
NH
AT
TA
N
ROCK ROAD
MEMORIAL WALK
EMPORIA COURT
GLEN ELDER
SALINA DRIVE
1377B 1378A
1379B
1380A 13971399
BR1
1413 1418
46500
1377A
1379A1378B
1380B
M
UN
IT
IO
NS
HO
LD
IN
G
PA
D
1106980
PRATT CT
HUTCHINSON CT
HUTCHINSON CT
MULVANE RD
12501121
412403
697687
46008
CONTROL TOWER
OLIVER ST.
TH
STR
EET
th
ST
RE
ET
AT
TI
C A
SEDGWICK ST
SA
LI
N A
D R
IV
E
M
CP
HE
RS
O N
D R
KANSAS CT.
KA
NS
AS
S
TR
EE
T
D O
U G
LA
SS
PIPER
CHENEY
TOPEKA ST
GODDARD
M
IS
SI
O
N
N
EW
TO
N
PIPER
LE
AV
EN
W
O R
TH
HUTCHINSON CT
ATCHISON ST
PRATT
HUTCHINSON DR
M
AD
IS
O
N
AB
IL
EN
E
KINGMAN
PRATT
W
IC
HI
TA
S
TR
EE
T
KANSAS STREET
U D
AL
L
R D
PRATT
LANSING
LI
BE
R
AL
LE
AV
EN
W
O R
TH
D
R
LINCOLN
DERBY DR
LA
W
RE
NC
E
DR
LA
W
RE
NC
E
CT
MULVANE
WINFIELD
WICHITA STREET
ROCK ROAD
AFFF
WASTE TANK
BUNKER
RANGE
RIFLE
CONFIDENCE
COURSE
ATSO AREA
50043
HUTCHINSON
BLAST DEFLECTORS
FT
F
1 FT
F
AGE
20037
40938
20040
20039 20036
PIPER
TOPEKA ST
50011
50010
MB-1
46015
46032
PI
TT
SB
U
R G
LA
W
RE
NC
E
DR
682 49020
PIPER
KA
N
SA
S
C T
KANSAS CT.
11051104
C O
FF
EY
VI
LL
E
IN
D
EP
EN
D
EN
C E
D R
RUSSELL ROAD
R U
SS
EL
L R
O
AD
U D
AL
L
R O
AD
U D
AL
L
R O
AD
UDALL ROAD
U D
AL
L
R O
AD
UDALL ROAD
ATTICA
LIBERAL RD
PARSONS
WICHITA STREET
DELTA RAMP
ECHO RAMP
FOX RAMP
CI
M
AR
RO
N
CI
M
AR
RO
N
LI
ND
SB
O
RG
WINCHESTER
LINDSBORG
CI
M
AR
RO
N
SEDGWICK ST
LI
BE
R
AL
C T
BASE FIRE
STATION NO. 1
FT
FT
FT
FT
FTFT
W T
WT
30006 30005
30004 30003 30002
30001
W T
FTFT
3001230013
WT
PE
DE
ST
RI
AN
B
RI
DG
E
PARSONS
NO
RT
H
BUILDING 42 HVAC REPLACEMENT
PRQE242910
ELECTRICAL
MECHANICAL
STRUCTURAL
ARCHITECTURAL
COVER SHEET AND INDEX
DRAWING INDEX
SHEET TITLE
COVER
CIVIL
SHEET NO.
184th INTEL WING Kansas Air National Guard
McConnell AFB Wichita KS
PROJECT LOCATION - BASE MAP
B ro ad w ay S t
ELECTRICAL
R id ge R d
MacArthur Rd
47th St
MECHANICAL
47th St
O liv er S t
R oc k R d
AFB
MC CONNELL
47th St
STRUCTURAL
ARCHITECTURAL
Communications
Security Police
Date:
Host CES Date:
Fire Department
Environmental/Bio
Date:
Date:
Date:
Date:
Safety
Date:
Using Agency Date:
Project Engineer
Base Engineer
Base Commander
Date:
Date:
COVER SHEET AND INDEX
AIRCRAFT
MID CONTINENT
AIRPORT
WICHITA
LEARJET
R id ge R d
Kellogg St
Pawnee St
W es t S t
Ar ka ns as
R iv er
W es t S t
Central Av
R id ge R d
Arkansas River
21st St
B ro ad w ay S t
DRAWING INDEX
KSANG
George W ash Blvd
31st St
O liv er S t
Central Av
Kellogg StH ill si de
S t
O liv er S t
R oc k R d
Pawnee St
Kellogg St
21st St
H ill si de
S t
O liv er S t
R oc k R d
N
S
21st St
W E
SHEET TITLE
COVER
CIVIL
SHEET NO.
VICINITY MAP
A-1
FIGHTING
SKWAHYAJ
FIGHTING
SKWAHYAJ
FLOOR PLAN, DEMO PLAN,
INSTALLATION LOCATION
AutoCAD SHX Text
EOD
AutoCAD SHX Text
PRO PAD
AutoCAD SHX Text
RADAR
AutoCAD SHX Text
TOWER
AutoCAD SHX Text
WOODEN BRIDGE
AutoCAD SHX Text
WOODEN BRIDGE
AutoCAD SHX Text
EXISTING CHILLER
AutoCAD SHX Text
NEW CHILLER
AutoCAD SHX Text
ICE STORAGE UNITS
AutoCAD SHX Text
125 TON
1 2 3
18 19
10 11
13A 17B
13B
5B
13C
21A
2 3
8 9
10 11
13A 17B
13B
5B
13C
21A
Date: Scale:
Sheet:
Sheet No.
Sheet Name:
ACAD File:
Check by:
R ev is io ns
Designer:
Drawn by:
Project No.
Project Name:
184th CES Kansas Air National Guard
McConnell AFB Wichita KS
PRQE142389
MR JEREMIAH SHAW
J.A.S. T.S.
N/A29 APRIL 24
A-1
R em ar ks
R ev
D at e
BUILDING 42 - FLOOR PLANNORTH
FIGHTING
SKWAHYAJ
FLOOR PLAN, DEMO PLAN,
HVAC PLACEMENT PLAN
HVAC
REPLACEMENT
BUILDING 42
Room 17 Building 42. dwg
DEMOLITION PLANNORTH
BUILDING 42 - INSTALLATION LOCATIONNORTH
13B 13A
D
D
D
RR
R
DRAWINGS ARE CONCEPTUAL AND NOT TO BE USED AS DESIGN DOCUMENT. DEVELOPMENT OF
DESIGN DOCUMENT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
AutoCAD SHX Text
PROJECT LOCATION ROOM 17A
AutoCAD SHX Text
PLACEMENT OF NEW 5-TON INDOOR UNIT
AutoCAD SHX Text
NEW DUCT WORK TO BE INSTALLED IN 13A, 13B AND 17
AutoCAD SHX Text
LOCATIONS OF COMMUNITCATING THERMOSTATS
AutoCAD SHX Text
PLACEMENT OF NEW 5-TON INDOOR UNIT
AutoCAD SHX Text
REMOVAL OF OUTSIDE CONDENSING UNITS
AutoCAD SHX Text
REMOVAL OF INDOOR MINI-SPLIT UNITS
AutoCAD SHX Text
INSTALLATION OF NEW LINES SETS LEADING TO OUTSIDE CONDENSING UNIT
AutoCAD SHX Text NOTES: 1. DEMOLITION INCLUDES ALL INTERIOR AND EXTERIOR MINI-SPLIT SYSTEMS AND COMPONENTS DEMOLITION INCLUDES ALL INTERIOR AND EXTERIOR MINI-SPLIT SYSTEMS AND COMPONENTS 2. NEW 5-TON UNIT WILL NEED TO BE INSTALLED IN ROOM 21 AND WILL BE DUCTED INTO ROOMS 13A, 13B AND 17 NEW 5-TON UNIT WILL NEED TO BE INSTALLED IN ROOM 21 AND WILL BE DUCTED INTO ROOMS 13A, 13B AND 17 3. THE OUTSIDE CONDENSING UNIT WILL BE INSTALLED IN THE SAME LOCATION AS THE OLD UNITS THE OUTSIDE CONDENSING UNIT WILL BE INSTALLED IN THE SAME LOCATION AS THE OLD UNITS 4. THE DUCT WORK LEADING INTO ROOM 17 WILL NEED TO BE GATED OFF AS THIS IS A SECURE ROOM. IT WILL THE DUCT WORK LEADING INTO ROOM 17 WILL NEED TO BE GATED OFF AS THIS IS A SECURE ROOM. IT WILL NEED TO MEET COSA STANDARDS 5. DUCT WORK CALCULATIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE PROPER SIZING DUCT WORK CALCULATIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE PROPER SIZING 6. ELECTRICAL CONNECTIONS FROM THE OLD UNIT CAN BE REUSED FOR THE NEW UNITELECTRICAL CONNECTIONS FROM THE OLD UNIT CAN BE REUSED FOR THE NEW UNIT
AutoCAD SHX Text
NEW RETURN AIR SUPPLY
| Sheets and Views |
| B42 HVAC Building 42_MOD-TS-CV |
| B42 HVAC Building 42_MOD-TS-A-1 |
File details come from the government source that posted it. Updated .