UWT065D40L - Cut Sheet.pdf
PDF 452 KB Posted
- Attached to
- Fire Department Extractor Federal contract opportunity
- Solicitation number
- W50S7L-20-R-0002
- Issued by
- Department of the Army National Guard
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site Visit Pictures.pdf | ||
| Install Fire Extractor SOW.doc | DOC document | |
| Extractor Plan Combined DWGS Contract Drawings.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 11110
LAUNDRY WASHER-EXTRACTOR, 65 LB. [29.5 KG] CAPACITY
PART 1 GENERAL
1.01 SECTION INCLUDES:
A. Automatic laundry washer-extractor for processing water-washed linen items
1.02 SYSTEM DESCRIPTION
A. DESIGN REQUIREMENTS:
1. Construction: 304 or equal stainless steel cylinder, tub and cover panels
2. Input voltage: X: 200-240/50- 60/1/3; 2/3 wire plus ground
3. Dry weight capacity ( lbs.
[kg] ):
65 [29.5]
4. Wash cylinder volume ( ft3 [l] ):
9.7 [246] minimum
5. Overall width ( in. [mm] ): 34.1 [867] nominal
6. Overall height ( in.
[mm] ):
64.4 [1637] nominal
7. Overall depth ( in.
[mm] ):
51.1 [1298] nominal
8. Number and size of water connections:
2 (Main fill) connections with 3/4 in. NH male connections and 2 (Spray rinse) connections with 3/4 in. NH male connections
9. Number and size of drain outlets:
1 outlet at 3 in.
10. Overflow: Internally plumbed
11. Control system: Programmable microprocessor
12. Cylinder drive: Inverter drive, poly V belt system
13. Drive motor ( hp [kW] ): 5.0 [3.7]
B. PERFORMANCE REQUIREMENTS:
1. Number of selectable wash speeds:
Variable 10-50 rpm
2. Number of selectable extract speeds ( RPM [G] ):
Variable 75 [2.5] - 477 [100]
3. RPM [G] at highest extract speed:
477 [100]
4. Chemical supply system
a. automatic flushing and 8 external supply signals
b. manually filled 5 compartment dry chemical dispensing system (optional - designated by D30V in the model number)
5. Configured for possible future addition of water reuse system
Section 7 - UW Specs
12-10-380 Part No. 4-18-224 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT April 2018
6. Control system
a. programmable microprocessor; (manual, PDA, laptop via IR)
b. 48 programmable cycles
c. 30 programmable water levels
d. graphic display with words and icons
e. automatic maintenance reminders
f. PC software with management reports
g. internet connectivity for off-site diagnostic capabilities
h. real-time clock allows time and date stamp to 100+ items
i. cycle counter
j. temperature controlled fill and thermal cool down
k. water monitoring: fill value, slow drain and automatic leak detection system
l. diagnostic capabilities
7. Drain valve automatically opens in event of power failure
8. Bearing protection: ozone resistant seals
1.03 DELIVERY, STORAGE AND HANDLING
A. ACCEPTANCE AT SITE:
1. Inspect machine for damage prior to acceptance. If damage is found, follow freight handler’s procedure for claims.
B. STORAGE AND PROTECTION
1. Machine should be stored in a site protected from weather, direct sunlight and temperature extremes. Do not remove packaging prior to storage.
2. If machine is to be stored for an extended period of time, consult manufacturer for special requirements.
1.04 SYSTEM STARTUP AND COMMISSIONING
A. Machine installation should be inspected by local manufacturer’s representative prior to startup and operation. The party installing the machine is responsible for setting the schedule for this inspection.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Alliance Laundry Systems LLC - UniMac, obtain commercial laundry equipment from a single manufacturer
2.02 QUALIFIED MODELS
A. UniMac model UWT065D40L (without soapbox) and UWT065D30L (with soap box option
[no substitutions])
PART 3 EXECUTION
3.01 INSTALLATION
A. Refer to and comply with manufacturer’s installation instructions. Do not deviate without permission from site owner, architect, general contractor and manufacturer’s local representative.
Section 7 - UW Specs
12-10-380 Part No. 4-18-224
Machine Dimensions and Specifications Models UWT065D40L
Equipment specifications are subject to change without notice. Design 5
Machine Dimensions and Specifications
PHM43L_SVG
A
B
C
D
E
G
H
I
J
M
N
R B
O
P G
H
I
Electrical Input
Circuit Breaker
FRONT
RIGHT
K
BACK
Drain
F
L L
Hot Fill Valve
Hot Spray Valve
Cold Fill ValveCold
Spray Valve
Dimensions and Foundation Requirements,
in. [mm] A 64.4 [1636] J 34.2 [869]
B 34.1 [866] K 60 [1524]
C 28.8 [732] L 12 [305]
D 51.1 [1298] M 2.5 [64]
E 23.19 [589] N 20 [508]
F 2 [51] O 53.4 [1356]
G* 8 [203] P 14.4 [366]
H 6 [152] Q 12 [305]
I 18 [457] R 60 [1524]
*Optional elevated pad
Water, Drain and Weight Specifications Number of drain outlets 1
Drain connection size, in. 3
Number of water inlets Main fill 2
Spray rinse 2
Water inlet connection size, in. Main fill 3/4
Spray rinse 3/4
Net weight, lbs. [kg] 1110 [499]
Standard shipping weight, lbs. [kg] 1150 [522]
Side clearance (minimum), in. [mm] 6 [153]
Side clearance (recommended), in. [mm] 12 [305]
Electrical Specifications
C od es
Vo lta ge
C yc le
Ph as e
W ire
Fu ll
Lo ad
A m ps
C irc ui t B re ak er
AW
G m m
X 200-
50-
1/3 2/3 12/ 7 15 14 2.5
12-10-380 Part No. 4-18-218
| 4-18-224_065d40l |
| 4-18-218_uwt065d40l_Design5 |
File details come from the government source that posted it. Updated .