SECTION 11110

LAUNDRY WASHER-EXTRACTOR, 65 LB. [29.5 KG] CAPACITY

PART 1 GENERAL

1.01 SECTION INCLUDES:

A. Automatic laundry washer-extractor for processing water-washed linen items

1.02 SYSTEM DESCRIPTION

A. DESIGN REQUIREMENTS:

1. Construction: 304 or equal stainless steel cylinder, tub and cover panels

2. Input voltage: X: 200-240/50- 60/1/3; 2/3 wire plus ground

3. Dry weight capacity ( lbs.

[kg] ):

65 [29.5]

4. Wash cylinder volume ( ft3 [l] ):

9.7 [246] minimum

5. Overall width ( in. [mm] ): 34.1 [867] nominal

6. Overall height ( in.

[mm] ):

64.4 [1637] nominal

7. Overall depth ( in.

[mm] ):

51.1 [1298] nominal

8. Number and size of water connections:

2 (Main fill) connections with 3/4 in. NH male connections and 2 (Spray rinse) connections with 3/4 in. NH male connections

9. Number and size of drain outlets:

1 outlet at 3 in.

10. Overflow: Internally plumbed

11. Control system: Programmable microprocessor

12. Cylinder drive: Inverter drive, poly V belt system

13. Drive motor ( hp [kW] ): 5.0 [3.7]

B. PERFORMANCE REQUIREMENTS:

1. Number of selectable wash speeds:

Variable 10-50 rpm

2. Number of selectable extract speeds ( RPM [G] ):

Variable 75 [2.5] - 477 [100]

3. RPM [G] at highest extract speed:

477 [100]

4. Chemical supply system

a. automatic flushing and 8 external supply signals

b. manually filled 5 compartment dry chemical dispensing system (optional - designated by D30V in the model number)

5. Configured for possible future addition of water reuse system

Section 7 - UW Specs

12-10-380 Part No. 4-18-224 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT April 2018

6. Control system

a. programmable microprocessor; (manual, PDA, laptop via IR)

b. 48 programmable cycles

c. 30 programmable water levels

d. graphic display with words and icons

e. automatic maintenance reminders

f. PC software with management reports

g. internet connectivity for off-site diagnostic capabilities

h. real-time clock allows time and date stamp to 100+ items

i. cycle counter

j. temperature controlled fill and thermal cool down

k. water monitoring: fill value, slow drain and automatic leak detection system

l. diagnostic capabilities

7. Drain valve automatically opens in event of power failure

8. Bearing protection: ozone resistant seals

1.03 DELIVERY, STORAGE AND HANDLING

A. ACCEPTANCE AT SITE:

1. Inspect machine for damage prior to acceptance. If damage is found, follow freight handler’s procedure for claims.

B. STORAGE AND PROTECTION

1. Machine should be stored in a site protected from weather, direct sunlight and temperature extremes. Do not remove packaging prior to storage.

2. If machine is to be stored for an extended period of time, consult manufacturer for special requirements.

1.04 SYSTEM STARTUP AND COMMISSIONING

A. Machine installation should be inspected by local manufacturer’s representative prior to startup and operation. The party installing the machine is responsible for setting the schedule for this inspection.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Alliance Laundry Systems LLC - UniMac, obtain commercial laundry equipment from a single manufacturer

2.02 QUALIFIED MODELS

A. UniMac model UWT065D40L (without soapbox) and UWT065D30L (with soap box option

[no substitutions])

PART 3 EXECUTION

3.01 INSTALLATION

A. Refer to and comply with manufacturer’s installation instructions. Do not deviate without permission from site owner, architect, general contractor and manufacturer’s local representative.

Section 7 - UW Specs

12-10-380 Part No. 4-18-224

Machine Dimensions and Specifications Models UWT065D40L

Equipment specifications are subject to change without notice. Design 5

Machine Dimensions and Specifications

PHM43L_SVG

A

B

C

D

E

G

H

I

J

M

N

R B

O

P G

H

I

Electrical Input

Circuit Breaker

FRONT

RIGHT

K

BACK

Drain

F

L L

QQ

Hot Fill Valve

Hot Spray Valve

Cold Fill ValveCold

Spray Valve

Dimensions and Foundation Requirements,

in. [mm] A 64.4 [1636] J 34.2 [869]

B 34.1 [866] K 60 [1524]

C 28.8 [732] L 12 [305]

D 51.1 [1298] M 2.5 [64]

E 23.19 [589] N 20 [508]

F 2 [51] O 53.4 [1356]

G* 8 [203] P 14.4 [366]

H 6 [152] Q 12 [305]

I 18 [457] R 60 [1524]

*Optional elevated pad

Water, Drain and Weight Specifications Number of drain outlets 1

Drain connection size, in. 3

Number of water inlets Main fill 2

Spray rinse 2

Water inlet connection size, in. Main fill 3/4

Spray rinse 3/4

Net weight, lbs. [kg] 1110 [499]

Standard shipping weight, lbs. [kg] 1150 [522]

Side clearance (minimum), in. [mm] 6 [153]

Side clearance (recommended), in. [mm] 12 [305]

Electrical Specifications

C od es

Vo lta ge

C yc le

Ph as e

W ire

Fu ll

Lo ad

A m ps

C irc ui t B re ak er

AW

G m m

X 200-

50-

1/3 2/3 12/ 7 15 14 2.5

12-10-380 Part No. 4-18-218

4-18-224_065d40l
4-18-218_uwt065d40l_Design5