A2 - Minimum Requirements for Concrete Jersey Barriers.docx
DOCX document 23 KB Posted
- Attached to
- Concrete Jersey Barriers
- Solicitation number
- W50S7G26QA028
- Issued by
-
Department of the Army National Guard
About this file
This is a minimum requirements specification document for precast concrete Jersey barriers procured by the 139th Airlift Wing of the Department of the Army National Guard. The Government requires 215 concrete Jersey barriers delivered to 705 Memorial Drive, Saint Joseph, MO 64503 on a FOB Destination basis. Each barrier must conform to standard Jersey profile specifications: 10 feet in length, 32 inches in height, 24 inches in base width, with blunt (non-connecting) flat-finished ends. The barriers must feature integrated forklift slots cast into the bottom toe to enable safe lifting and placement during installation.
The concrete must meet a minimum compressive strength of 3,500 PSI at 28 days and be formulated to withstand regional freeze-thaw cycles. Internal steel reinforcement, either rebar or welded wire mesh, is required to prevent structural failure under load or during handling. Vendors submitting quotes must include all transportation fees, estimated delivery lead times, and provide vendor CAGE/UEI identification details. This procurement is solicited under Solicitation Number W50S7G26QA028.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Concrete Jersey Barriers QA.pdf | ||
| Solicitation - W50S7G26QA028.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum Requirements for Concrete Jersey Barriers The Government requires 215 Concrete Jersey Barriers meeting or exceeding the following specifications:
· Quantity: 215 Units (Each)
· Profile Shape: Standard Jersey Shape (nominal 32" Height x 24" Base Width)
· Length: 10 Feet (nominal)
· End Configuration: Blunt end (non-connecting / flat-finished ends)
· Handling: Built-in forklift slots cast into the bottom toe of the barrier to allow safe lifting and placement.
· Concrete Strength: Minimum 3,500 PSI compressive strength at 28 days. Concrete must be formulated to withstand regional freeze-thaw cycles.
· Reinforcement: Internal steel reinforcement (rebar or welded wire mesh) to prevent structural failure under load or during handling.
Delivery to: 705 Memorial Drive, Saint Joseph, MO 64503
File details come from the government source that posted it. Updated .