This document is a Product Description for two covered parking structures with specific technical requirements. The structures are 130 feet long x 20 feet wide x 12 feet high (green area) and 70 feet long x 35 feet wide x 16 feet high (yellow area), with open sides and only a top covering required. Key technical specifications include hurricane wind rating up to 170 MPH, minimum 12-gauge beams/columns/purlins with hot dip galvanized or corrosion-resistant coating, and 26-gauge galvanized steel roofing with appropriate pitch and optional gutters. The contractor must submit product data, color samples, and provide a minimum 1-year full materials and labor warranty. Installation requires anchoring the structures to a concrete parking lot, with the orientation dependent on the number of supporting columns. The document includes example structure images illustrating potential design configurations.

View the file

Other files

File Type Posted
Combo W50S77-25-Q-0014.pdf PDF
Product Description Covered Parking.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Product Description

Two Covered Parking Structures:

1. Dimensions 130L x 20W x 12H

2. Dimensions 70L x 35W x 16H

All sides can be open, only a top covering required.

Must meet the following criteria:

Wind Load: Hurricane rated up to 170 MPH sustained wind

Beams/Columns/Purlins:

1. Minimum of 12 gauge

2. Coating: Hot Dip Galvanized, aluminum, or suitable corrosion control prevention coatings that last as long as Hot Dip Galvanized Steel

Roofing:

1. Minimum of 26 Gauge Rolled Form Galvanized Steel.

2. Appropriate Hot dipped Galvanized Fasteners

3. Finished top and underside

4. Appropriate Roof pitch for reliable water runoff

5. Gutters over the opening only. (4” wide x 5” deep) and downspouts (4” X 3”) in 26 gauge galvanized steel. Gutters only required if roof is pitched forward (A-Frame style) if single pitch with water running off back, gutters not required.

Contractor will submit:

A. Product Data: Provide manufacturer’s data on products.

B. Color Submittals: Provide manufacturer color sample for color selection for all painted surfaces.

WARRANTY:

A. System including all equipment and devices shall have a minimum of a 1 year full

Materials and Labor Warranty.

EQUIPMENT:

A. Any reference to a particular make and model are being used for example only. An equivalent or equal will be accepted for all items under this contract.

INSTALLATION

A. Equipment and materials shall be installed in an approved manner and in accordance with equipment manufacturers’ installation requirements. The installation of the covered training area orientation is dependent on the number of columns supporting the structure. Covernings will be anchored to concrete parking lot.

EXAMPLE STRUCTURES:

Example 1(sides not required)

Example 2 (sides not required)

Example 3 (sides not required)

Green denotes 130ftLx20ftWx12ftH Yellow denotes 70ftLx35ftWx16ftH

File details come from the government source that posted it. Updated .