About this file
This document is a Product Description for two covered parking structures with specific technical requirements. The structures will be 40 feet long by 40 feet wide, with heights of 16 feet and 12 feet respectively, featuring three covered sides with a single drive-in opening. Technical specifications include hurricane wind rating up to 120 MPH, minimum 12-gauge beams/columns/purlins with hot-dip galvanized or corrosion-resistant coating, and 26-gauge galvanized steel roofing with appropriate pitch and gutters. The contractor must submit product data and color samples, provide a minimum one-year full materials and labor warranty, and install the structures according to manufacturer guidelines, anchoring the coverings to a concrete parking lot. The installation orientation will depend on the number of supporting columns and customer preference.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Product Description Covered Parking Revision 1.pdf | ||
| Combo W50S77-25-Q-0014.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Product Description
Two Covered Parking Structures:
1. Dimensions 40L x 40W x 16H
2. Dimensions 40L x 40W x 12H
Three sides and roof to be covered, only opening for drive in.
Must meet the following criteria:
Wind Load: Hurricane rated up to 120 MPH sustained wind
Beams/Columns/Purlins:
1. Minimum of 12 gauge
2. Coating: Hot Dip Galvanized, aluminum, or suitable corrosion control prevention coatings that last as long as Hot Dip Galvanized Steel
Roofing:
1. Minimum of 26 Gauge Rolled Form Galvanized Steel.
2. Appropriate Hot dipped Galvanized Fasteners
3. Finished top and underside
4. Appropriate Roof pitch for reliable water runoff
5. Gutters over the opening only. (4” wide x 5” deep) and downspouts (4” X 3”) in 26 gauge galvanized steel
Contractor will submit:
A. Product Data: Provide manufacturer’s data on products.
B. Color Submittals: Provide manufacturer color sample for color selection for all painted surfaces.
WARRANTY:
A. System including all equipment and devices shall have a minimum of a 1 year full
Materials and Labor Warranty.
EQUIPMENT:
A. Any reference to a particular make and model are being used for example only. An equivalent or equal will be accepted for all items under this contract.
INSTALLATION
A. Equipment and materials shall be installed in an approved manner and in accordance with equipment manufacturers’ installation requirements. The installation of the covered training area orientation is dependent on the number of columns supporting the structure. Installation direction to be determined by customer after determination of pillar placement. Covernings will be anchored to concrete parking lot.