Questions and Answers v2 - 24Sept2024.pdf

PDF 69 KB Posted

Attached to
Office Furniture (with Space Study)
Solicitation number
W50S72-24-Q-7114
Issued by

About this file

This document is a set of Questions and Answers (Q&A) regarding Solicitation Number W50S72-24-Q-7114 for Office Furniture (with Space Study). The solicitation is being issued as a Request for Quotation (RFQ) by the Department of the Army National Guard. The key details include:

The solicitation is for the procurement of commercial office furniture and associated services, including a space plan to determine the most efficient layout of workstations, standup workstations, file cabinets, bookcases, and a corner table. The Government intends to award a firm-fixed price contract to the lowest priced vendor that meets or exceeds the minimum specifications. The procurement is set aside 100% for small businesses under NAICS code 337211 with a size standard of 1,000 employees. The Q&A document provides clarification on the dimensions of the UHF base station and flightline camera display, as well as the height of the mezzanine from the hangar floor. Proposals are due by 1:00 PM Central on Monday, 23 September 2024.

View the file

Other files

File Type Posted
Questions and Answers v1 - 17Sept2024.pdf PDF
261-RM 227 .pdf PDF
SOW Bldg. 261 Office Furniture.pdf PDF
Full-Text Provisions and Clauses.pdf PDF
261-RM 236.pdf PDF
Vendor Information Sheet.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation Number: W50S72-24-Q-7114 Questions and Answers v2

Current as of 24 September 2024

Q1. What is the height of the mezzanine from the hangar floor?

A1. The mezzanine doors are approximately 14’ from the hangar floor. (This is a revised height from the previous ‘Version 1’ Q & A, stating that the doors were 12’ from the hangar floor).

Q2. Please provide the dimensions of the UHF base station and flightline camera display in order to determine a surface that would be large enough to facilitate.

A2. The systems sitting on the current table take up approximately 22” deep x 32” wide.