DRAFT SOW Attachment 1 - Drawings.pdf
PDF 17 MB Posted
- Attached to
- Repair C-17 Avionics Shop
- Solicitation number
- W50S6L-20-B-0015
About this file
This document outlines a federal contract opportunity for repair work on an avionics shop. The 176th Air Wing of the Alaska Air National Guard intends to issue an Invitation for Bid to award a single firm fixed-price contract to renovate a 1,600 square foot avionics shop within Hangar 12 at Joint Base Elmendorf-Richardson in Alaska. The base bid includes office, shop, and storage space renovations. There are two options involving telecommunications cabling and relocating avionics equipment. The project value is estimated between $500,000 and $1,000,000. A bid bond of 20% is required. The construction period is anticipated to be 150 days after notice to proceed. The NAICS code is 236220. This will be a total small business set-aside with a size standard of $36.5 million average annual revenue. The solicitation is expected to be issued on or around July 16, 2020 and remain open for at least 30 calendar days.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DRAFT SOW - FXSB172828.pdf | ||
| DRAFT SOW Attachment 2 - Specs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BDBD
BD
MIST ELIM
REFR DRYERDESSICANT
TANK
NIC
NIC
NIC
BDBD
BD
MIST ELIM
REFR DRYERDESSICANT
TANK
NIC
NIC
NIC
SHPG./REC.
STAGING AREA
230+/-
CATE AREA
356+/-
SHOP/STORAGE
766+/-
OPEN
OFFICE
206+/-
A
A
A
BB
B
C
DD
C
E
F
TRUE
NORTH
PLAN
NORTH
AL
AS
KA
AI
R N
AT
IO
N
AL
G U
AR
D
AS INDICATED
AREA OF SCOPE
EXISTING
MECHANICAL REMODEL PLAN - FIRST FLOOR
MECHANICAL DEMOLITION PLAN - FIRST FLOOR
06/30/21
NIC
NIC
TRUE
NORTH
PLAN
NORTH
AL
AS
KA
AI
R N
AT
IO
N
AL
G U
AR
D
AS INDICATED
AREA OF SCOPE
EXISTING
MECHANICAL REMODEL PLAN - MEZZANINE
MECHANICAL DEMOLITION PLAN - MEZZANINE
AL
AS
KA
AI
R N
AT
IO
N
AL
G U
AR
D
AREA OF SCOPE
EXISTING
KA
AI
R N
AT
IO
N
AL
G U
AR
D
AS INDICATED
AREA OF SCOPE
EXISTING
MAKE UP AIR UNIT 3
SUPPLY AIR DIFFUSER DETAIL 1
CEILING
-+45°
VOLUME DAMPER
INSULATED FLEXIBLE DUCT
(5'-0" MAX. LENGTH)
STAINLESS STEEL SCREW
TYPE CLAMP (TYP. OF 2)
OPPOSED BLADE DAMPER (IF
REQUIRED)
DIRECTIONAL CONTROL
VANES (FURNISH WITH
DIFFUSER)
SPONGE GASKET (ALL
AROUND)
REFER TO THE SPECIFICATIONS
FOR CONTRACTOR DESIGNED
SUPPORTS AND BRACING
2"x1/8" FLAT BAR ALL AROUND
SQUARE-TO-ROUND ADAPTER (IF
REQUIRED)
SECURE TO STRUCTURE ABOVE
REFER TO THE SPECIFICATIONS
FOR CONTRACTOR DESIGNED
SUPPORTS AND BRACING
4" WIDE SHEET METAL STRAP
RETURN AIR SIMILAR
HANGER
LOAD RATED
FASTENERS
LOAD RATED
FASTENERS
BAND OF SAME
SIZE AS HANGER
STRAP
36" DIA. DUCT (MAX.)
24" DIA. DUCT (MAX.)
ROUND DUCT HANGERS 2
INLINE EXHAUST FAN MOUNTING DETAIL 4
FLOOR/ROOF CONSTRUCTION
(BY MFR.)
ROUND DUCT COLLAR
FLEXIBLE CONNECTION (TYP.)
ROUND-TO-RECTANGULAR
TRANSITION (TYP.)
CEILING
FOR CONTRACTOR DESIGNED
REFER TO THE SPECIFICATIONS
SUPPORTS AND BRACING
TYPE 'RMX') (TYP.)
ISOLATIOR (VIBREX
SPRING VIBRATION
BY MFR. (TYP.)
HANGER BRACKET
CENTRIFUGAL
EXHAUST FANEXHAUST REGISTER
1. DETAIL IS SIMILAR FOR VERTICAL FAN ARRANGEMENT.
NOTE:
DISCHARGE DUCT (REF.
FLOOR PLANS FOR
SIZE/TYPE.)
HEAT PUMP MOUNTING DETAIL 5
AIR
FLOW
18"
SECURE UNIT TO STEEL FRAMING.
(SEE NOTE.)
STEEL FRAMING (SEE
NOTE.)
REFER TO ARCHITECTURAL
DRAWINGS FOR WALL TYPE
WELDED (SEE NOTE.)
CLEVIS PIPE HANGERS 6
CLEVIS HANGER
THREAD ROD
SIZED FOR
LOAD
RIGID PIPE
PIPE INSULATION
CALCIUM
SILICATE
SHIELD
1. SIZE HANGER TO ADEQUATELY
SUPPORT LOAD
2. SIZE CALCIUM SILICATE SHIELD TO
FIT PIPE AND INSULATION THICKNESS.
3. SIZE HANGER TO FIT CALCIUM
SILICATE SHIELDS.
NOTES
TYPICAL FLEXIBLE CONNECTION DETAIL 8
FAN
OUTLET/INLET
1-1/2" POCKET SLIP
20 U.S. GAGE STEEL
3"-4" (10" MAX.)
DUCTIMPREGNATED FABRIC
FIRE RESISTANT RUBBER
SHEET METAL SCREWS
ON 4" CENTERS
1" x 1/8"
BAND IRON
NOTE: REFER TO THE SPECIFICATIONS FOR CONTRACTOR
DESIGNED SUPPORTS AND BRACING.
REFER TO THE SPECIFICATIONS
FOR CONTRACTOR DESIGNED
SUPPORTS AND BRACING.
KA
AI
R N
AT
IO
N
AL
G U
AR
D
AS INDICATED
AREA OF SCOPE
EXISTING
1501.0 115/60/11/37.2BELT800 1725-LOREN COOK
90QMX
EXHAUST FAN SCHEDULE
CENTRIFUGAL
INLINE
1. EMERGENCY AIR DISTRIBUTION OFF SWITCH
DIRECT FIRED MAKE-UP AIR UNIT
1.
MODINE
800DBP75TMRNN40F2AL1BDA 800 1.0 1/3 75.0 60.8 460 1.53 530
VARIABLE FREQUENCY DRIVE2.
60-17 60
30% EFFICIENCY FILTERS
HEAT PUMP UNIT SCHEDULE
1.
SAMSUNG
18.00AC018KXADCH/AA 18.00 19.5 208 -1 10560R-410A
2012.7
HIGH STATIC DUCTED INDOOR UNIT SCHEDULE
1.
18.00 18.00 19.5 - -- 52-R-410A
POWERED FROM OUTDOOR UNIT.
9.00 9.00 21.0 - -- 44-R-410A --
SAMSUNG
9.00AC009KXADCH/AA 9.00 21.0 208 -1 8060R-410A 1510.6
SAMSUNG
AC018KNLDCH/AA
SAMSUNG
AC009KNLDCH/AA
2. PROVIDE WIRED CONTROLS.
20.00
12.00
20.00
12.00
122208/60/1VAPORMIST
VM08
HUMIDIFIER SCHEDULE
1. PROVIDE WITH SPACE DISTRIBUTION UNIT
38.5 AMPSCABINET 24 LBS/HR
TITUS
PAS-AA
SUPPLY
AIR TERMINAL SCHEDULE
TITUS
R-OMNI-AA
SUPPLY
NOTES:
A
B
100 - 20024 x 24
22 DIA 0 - 300
C
D
TITUS
PAR-AA
RETURN 24 x 24
TITUS
PAR-AA
EXHAUST 24 x 24 0 - 100
E TITUS
350FL
EXHAUST 20 x 14 0 - 300
BORDER TYPE SHALL BE COMPATIBLE WITH CEILING
ADJUSTABLE ROUND SUPPLY AIR DIFFUSER
1 2
10 201 - 300
100 - 2008 10 201 - 300
116 x 8
0.1 30
250.2
300.1
250.1
300.1
1TITUS
PAR-AA
EXHAUST 12 x12 0 - 100 300.18F
LOW LEAKAGE CONTROL DAMPER3.
2. LOW LEAKAGE CONTROL DAMPER
FIRE ALARM/MASS NOTIFICATION SYSTEM NOTESFIRE SPRINKLERFIRE SPRINKLER
FIRE ALARM/MASS NOTIFICATION SYMBOLS
PIPING SYMBOLS
MISCELLANEOUS
INSPECTOR'S TEST CONNECTION/AUXILARY DRAIN
4 IN X 2.5 IN X 2.5 IN WALL MOUNTED FIRE DEPARTMENT CONNECTION
FOR WET PIPE SPRINKLER SYSTEMS ONLY
CALCULATION NODE POINT
(1 NODE)
CALCULATION NODE POINT
(2 NODES)
VALVE IN DROP
GATE VALVE
TEST PORT
PRESSURE GAUGE
WITH GAUGE COCK
PRESSURE CONTROL
VALVE
RELIEF VALVE
CHECK VALVE
ECCENTRIC REDUCER
TEE OUTLET DOWN
TEE OUTLET UP
STRAINER WITH
BLOWDOWN VALVE
UNION
VALVE IN CENTER DROP
DIRECTION OF
SLOPE DOWN
CONCENTRIC REDUCER
DIRECTION OF FLOW
VALVE IN RISE
ELBOW DOWN
ELBOW UP
WET PIPE SPRINKLER SYSTEM RISER
2.5 IN HOSE VALVE
SPRINKLER DESIGN CRITERIA (MISSILE ASSEMBLY SHOP)
PATTERN HAZARD
CLASSIFICATION
DESIGN REQUIREMENTS MAX SPRINKLER
SPACING
DURATION
OF SUPPLY
REQUIRED
SPRINKLERS
NONE LIGHT
0.1 GPM/SF OVER MOST REMOTE 1,500 SF PLUS 250 GPM
HOSE STREAM
60 MIN 225 SF
ORDINARY, QUICK
RESPONSE K=5.6
ORDINARY
0.2 GPM/SF OVER MOST REMOTE 2,500 SF PLUS 250 GPM
HOSE STREAM
60 MIN 130 SF
ORDINARY, QUICK
RESPONSE K=8.0
A. PROVIDE A MODIFICATION TO THE EXISTING WET PIPE FIRE SPRINKLER SYSTEM FOR
THE REMODEL AREA DESIGNED AND INSTALLED IN ACCORDANCE WITH UFC 3-600-01,
NFPA 13, 2019 AND SPECIFICATION SECTION 211313.
B. ANY PIPE SIZES THAT ARE SHOWN FOR THE WET PIPE SPRINKLER SYSTEM HAVE
BEEN HYDRAULICALLY CALCULATED PER UFC 3-600-01. DENSITY AND SPACING
REQUIREMENTS ARE LISTED IN THE SPRINKLER DESIGN CRITERIA TABLE BELOW.
FIELD VERIFY SYSTEM DESIGN AND LAYOUT PRIOR TO FABRICATION OR
INSTALLATION.
C. THE ENGINEER'S CALCULATIONS ARE UTILIZED TO DETERMINE THE ADEQUACY OF
THE FIRE WATER SUPPLY AND TO SELECT APPROXIMATE SIZE, QUANTITY, AND TYPE
OF EQUIPMENT. PROVIDE COMPLETE FIRE SPRINKLER SYSTEM CALCULATION WITH
SHOP DRAWINGS TO INCLUDE THE PRESSURE LOSS FOR THE MOST DEMANDING
AREA.
D. THE TOTAL CALCULATED WATER DEMAND FOR EACH OCCUPANCY IS EQUAL TO THE
SPRINKLER SYSTEM DEMAND AS CALCULATED PER UFC 3-600-01. OUTSIDE HOSE
STREAM IS PROVIDED THROUGH FIRE HYDRANTS SUPPLIED BY THE DOMESTIC
WATER SYSTEM.
E. PROVIDE QUICK RESPONSE BRASS UPRIGHT SPRINKLERS THROUGHOUT AREAS
EXPOSED TO STRUCTURE UNLESS NOTED OTHERWISE. PROVIDE WHITE QUICK
RESPONSE RECESSED PENDENT SPRINKLERS WITH WHITE ESCUTCHEONS IN AREAS
WITH SUSPENDED CEILINGS.
F. PROVIDE PIPE HANGERS AND SWAY BRACING ON ALL NEW FIRE SPRINKLER SYSTEM
PIPING AND EQUIPMENT, INSTALLED PER NFPA 13 AS REQUIRED BY UFC 3-600-01 AND
UFC 4-010-01.
G. SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE AND ROOM USE. SEE
ARCHITECTURAL REFLECTED CEILING PLANS FOR THE LOCATION OF ALL
CEILING-MOUNTED DEVICES. FIELD VERIFY AND COORDINATE THE LOCATIONS OF ALL
SYSTEM COMPONENTS INCLUDING PIPING, ALARMS, DRAINS, TEST CONNECTIONS,
ETC. WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL
EQUIPMENT WITHIN THE BUILDING.
H. PROVIDE SLEEVES AND WALL PLATES FOR ALL PENETRATIONS THROUGH WALLS OR
FLOORS. FIELD VERIFY APPROXIMATE WALL AND FLOOR PENETRATIONS SHOWN ON
THE PLANS.
I. PROVIDE AUXILIARY DRAINAGE FOR ALL TRAPPED SECTIONS OF PIPE, REGARDLESS
OF VOLUME. PROVIDE AUTOMATIC AIR VENTS AT ALL HIGH POINTS IN EACH WET PIPE
SPRINKLER SYSTEM.
J. PROVIDE ACCESS DOORS AND SIGNAGE WHERE ACCESS IS REQUIRED TO
CONCEALED SPRINKLER EQUIPMENT, VALVES AND CONTROLS LOCATED IN WALLS OR
ABOVE CEILINGS.
K. WET PIPE SPRINKLER SYSTEM PIPING TO BE MINIMUM SCHEDULE 40 BLACK STEEL
AND JOINED BY A COMBINATION OF GROOVED, FLANGED, AND THREADED FITTINGS.
MARK ALL EXPOSED INTERIOR PIPING EXCEPT BRANCHLINES AND MAINS LESS THAN
2-1/2" WITH PLASTIC WRAP AROUND-TYPE LABELS CONFORMING TO ASME/ANSI A13.1.
INICATE THE TYPE OF FLUID CARRIED AND DIRECTION OF FLOW. STICK-ON, STRAPS,
OR ADHESIVE TAPE LABELS ARE NOT PERMITTED.
L. THE DOCUMENTS DEPICT PERFORMANCE LEVEL ENGINEERING DESIGN CRITERIA TO
BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE FIRE SPRINKLER SYSTEM.
PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER
AND AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN SHOP
DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY TO
PROVIDE A COMPLETE INSTALLATION AND COMPLY WITH BASE STANDARDS.
A. PROVIDE A MODIFICATION TO THE EXISTING FIRE ALARM/MASS NOTIFICATION SYSTEM
IN ACCORDANCE WITH 2019 NFPA 72, UFC 3-600-01, UFC 4-021-01, AND ADA/ABA.
B. EXISTING INTELLIGENT ADDRESSABLE FIRE ALARM/MASS NOTIFICATION CONTROL
PANEL (FMCP) TO REMAIN.
C. PROVIDE POWER LIMITED FIRE ALARM CIRCUITS. PROVIDE MINIMUM 16 AWG CLASS B
NOTIFICATION APPLIANCE CIRCUITS. PROVIDE MINIMUM 18 AWG CLASS B INITIATING
DEVICE AND SIGNALING LINE CIRCUITS.
D. INSTALL ALL WIRING IN MINIMUM 3/4 IN. CONDUIT.
E. DO NOT LOCATE SMOKE OR HEAT DETECTORS IN DIRECT AIR OR CLOSER THAN 3
FEET FROM AN AIR SUPPLY OR RETURN DIFFUSER. INCREASE SEPARATION DISTANCE
WHEN ALONG DIRECT PATH OF AIR FLOW OR WHEN AIR VELOCITY IS HIGHER THAN
NORMAL.
F. MOUNT ALL WALL-MOUNTED NOTIFICATION APPLIANCES WITH THE BOTTOM OF THE
STROBE LENS AT 80 IN. AFF, OR 6 IN. BELOW THE CEILING, WHICHEVER IS LOWER.
G. PROVIDE COMBINED FIRE ALARM AND MASS NOTIFICATION DEVICES WITH WHITE
FACEPLATES THROUGHOUT FINISHED AREAS OF THE REMODEL AREA MARKED
"ALERT" PER UFC 3-600-01 AND UFC 4-021-01. PROVIDE ADDITIONAL MASS
NOTIFICATION OR FIRE ALARM AUDIBLE NOTIFICATION APPLIANCES AS NECESSARY
TO MEET THE AUDIBILITY REQUIREMENTS OF NFPA 72 AND INTELLIGIBILITY
REQUIREMENTS OF UFC 4-021-01. ALL STROBES WITHIN A SINGLE FIELD OF VIEW
SHALL BE SYNCHRONIZED.
H. THE MASS NOTIFICATION SYSTEM SHALL BE ABLE TO OVERRIDE THE FIRE ALARM
AUDIBLE MESSAGES AND VISUAL SIGNALS (FOR A MAXIMUM OF 10 MINUTES) TO
PROVIDE INTELLIGIBLE VOICE COMMANDS DURING SIMULTANEOUS FIRE AND
TERRORIST EVENTS. ALL OTHER FEATURES OF THE FIRE ALARM SYSTEM, INCLUDING
THE TRANSMISSION OF SIGNALS TO THE BASE REPORTING STATION, SHALL REMAIN
FUNCTIONAL.
I. THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT
TO BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE FIRE ALARM SYSTEM BY
THE CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL
FROM THE ENGINEER AND THE AUTHORITY HAVING JURISDICTION PRIOR TO
INSTALLATION. INCLUDE IN SHOP DRAWINGS AND CALCULATIONS ANY ADDITIONAL
EQUIPMENT NECESSARY, INCLUDING INITIATING DEVICES AND NOTIFICATION
APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION AND COMPLY WITH BASE
STANDARDS.
CEILING-MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER/STROBE
WITH CLEAR LENS AND WHITE FACEPLATE MARKED "ALERT"
CEILING-MOUNTED FIRE ALARM/MASS NOTIFICATION STROBE WITH
CLEAR LENS AND WHITE FACEPLATE MARKED "ALERT"
WALL-MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER
WALL-MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER/STROBE
WITH CLEAR LENS AND WHITE FACEPLATE MARKED "ALERT"
WALL-MOUNTED FIRE ALARM/MASS NOTIFICATION STROBE WITH CLEAR
LENS AND WHITE FACEPLATE MARKED "ALERT"
R
RETURN/SUPPLY AIR DUCT SMOKE DETECTOR (SUPPLIED BY FIRE
ALARM CONTRACTOR; INSTALLED BY MECHANICAL CONTRACTOR)
/S
RISER LOCATION
AREA OF WORK
CLEAR VISUAL ALARM DEVICE (FIRE ALARM)
AMBER STROBE (MNS) DEVICE
F-0.1
FIRE PROTECTION
GENERAL NOTES
AND LEGEND
SB
JO
JS
R E
P A
I R
H
A N
G A
R
F
O
C
A
V I O
N I C
S
S
H O
P
A L
A S
K
N
T
I O
N A
L
G
U A
R D
C
M
A I N
T E
N A
N C
E
C
O M
P L
E X
J O
I N
T
B
A S
E
E
L M
E N
D O
F
C
H A
R D
S O
N
J B
E R
FDZE3500
AS INDICATED
AREA OF SCOPE
EXISTING
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text Date
AutoCAD SHX Text Description
AutoCAD SHX Text By
AutoCAD SHX Text Revision:
AutoCAD SHX Text No.
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Drawing Title:
AutoCAD SHX Text Designed By:
AutoCAD SHX Text Jacobs Project No.:
AutoCAD SHX Text Scale:
AutoCAD SHX Text
2600 MICHELSON DRIVE, SUITE 500, IRVINE CA. 92612
AutoCAD SHX Text
(949) 224-7500 FAX (949) 224-7501
AutoCAD SHX Text Keyplan:
AutoCAD SHX Text Seal:
AutoCAD SHX Text
PLOT DATE:
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
USER NAME:
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text A 12/20/19 35%35%
AutoCAD SHX Text B 03/19/20 95%95%
AutoCAD SHX Text
C 04/17/20 FINAL DESIGN SMTL. FINAL DESIGN SMTL.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
F-1.0
FIRE ALARM
RENOVATED AREA
DEMOLITION AND
NEW PLAN
SB
JO
JS 18
RENOVATED AREA FIRE ALARM PLAN
DEMOLITION KEY NOTES
GENERAL NOTES
1. REFER TO SHEET F-0.1 FOR ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
2. REFER TO SHEET F-5.0 FOR FIRE ALARM RISER DIAGRAM, SEQUENCE OF OPERATIONS, AND DETAILS.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION WITH LIGHTS,
MECHANICAL DIFFUSERS, AND CEILING GRID.
REMOVE EXISTING FIRE ALARM/MASS NOTIFICATION DEVICES IN PAINT BOOTH AREAS.
TRUE
NORTH
PLAN
NORTH
KEY NOTES
R E
P A
N
G A
R
F
A
V I O
N I C
S
S
H O
P
A L
A S
T
I O
N A
L
G
U A
R D
C
M
A I N
T E
N A
N C
E
C
O M
P L
E X
J O
I N
T
B
A S
E
E
L M
E N
D O
C
H A
R D
S O
N
J B
E R
FDZE3500
AS INDICATED
AREA OF SCOPE
EXISTING
RENOVATED AREA FIRE ALARM DEMOLITION PLAN
TRUE
NORTH
PLAN
NORTH
RELOCATE EXISTING FIRE ALARM STROBE, MASS NOTIFICATION STROBE, AND SPEAKER
TO ACCOMMODATE NEW AREA LAYOUT.
AutoCAD SHX Text
CATE AREA
AutoCAD SHX Text 100A
AutoCAD SHX Text
SHIPPING /
AutoCAD SHX Text
RECIEVING AREA
AutoCAD SHX Text 100C
AutoCAD SHX Text
OPEN. OFFICE
AutoCAD SHX Text 100B
AutoCAD SHX Text
EQUIP./STOR.
AutoCAD SHX Text
AREA
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text Description
AutoCAD SHX Text By
AutoCAD SHX Text Revision:
AutoCAD SHX Text No.
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Drawing Title:
AutoCAD SHX Text Designed By:
AutoCAD SHX Text Jacobs Project No.:
AutoCAD SHX Text Scale:
AutoCAD SHX Text
2600 MICHELSON DRIVE, SUITE 500, IRVINE CA. 92612
AutoCAD SHX Text
(949) 224-7500 FAX (949) 224-7501
AutoCAD SHX Text Keyplan:
AutoCAD SHX Text Seal:
AutoCAD SHX Text
PLOT DATE:
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
USER NAME:
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 12'
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
SCALE: 1/16"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 24'
AutoCAD SHX Text 32'
AutoCAD SHX Text 40'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A 12/20/19 35%35%
AutoCAD SHX Text B 03/19/20 95%95%
C 04/17/20 FINAL DESIGN SMTL. FINAL DESIGN SMTL.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
F-2.0
FIRE PROTECTION
DEMOLITION AND
NEW PLAN
SB
JO
JS
RENOVATION AREA FIRE PROTECTION PLAN
DEMOLITION KEY NOTES
GENERAL NOTES
1. REFER TO SHEET F-0.1 FOR ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
2. REFER TO SHEET F-5.1 FOR FIRE SPRINKLER DETAILS.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION WITH LIGHTS,
MECHANICAL DIFFUSERS, AND CEILING GRID.
REMOVE EXISTING SPRINKLERS, PIPE, VALVES AND FITTINGS ASSOCIATED WITH PAINT
BOOTHS. EXISTING PIPE SERVING OVERHEAD SPRINKLER SYSTEM TO BE LEFT IN PLACE.
TRUE
NORTH
PLAN
NORTH
R E
P A
N
G A
R
F
A
V I O
N I C
S
S
H O
P
A L
A S
T
I O
N A
L
G
U A
R D
C
M
A I N
T E
N A
N C
E
C
O M
P L
E X
J O
I N
T
B
A S
E
E
L M
E N
D O
C
H A
R D
S O
N
J B
E R
FDZE3500
AS INDICATED
AREA OF SCOPE
EXISTING
RENOVATION AREA FIRE PROTECTION DEMOLITION PLAN
TRUE
NORTH
PLAN
NORTH
FIRE SPRINKLER DESIGN CRITERIA
PATTERN HAZZARD
CLASSIFICATION
DESIGN REQUIREMENTS MAX SPACING
LIGHT 0.1 GPM/SF OVER MOST REMOTE 1,500 SF PLUS
250 GPM HOSE STREAM
225 SF
ORDINARY 0.2 GPM/SF OVER MOST REMOTE 2,500 SF PLUS
250 GPM HOSE STREAM
130 SF
KEY NOTES
UTILIZE EXISTING SPRINKLER SYSTEM TO PROTECT THIS AREA.
AutoCAD SHX Text
CATE AREA
AutoCAD SHX Text 100A
AutoCAD SHX Text
SHIPPING /
AutoCAD SHX Text
RECIEVING AREA
AutoCAD SHX Text 100C
AutoCAD SHX Text
OPEN. OFFICE
AutoCAD SHX Text 100B
AutoCAD SHX Text
SHOP/STOR.
AutoCAD SHX Text
AREA
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text Description
AutoCAD SHX Text By
AutoCAD SHX Text Revision:
AutoCAD SHX Text No.
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Drawing Title:
AutoCAD SHX Text Designed By:
AutoCAD SHX Text Jacobs Project No.:
AutoCAD SHX Text Scale:
AutoCAD SHX Text
2600 MICHELSON DRIVE, SUITE 500, IRVINE CA. 92612
AutoCAD SHX Text
(949) 224-7500 FAX (949) 224-7501
AutoCAD SHX Text Keyplan:
AutoCAD SHX Text Seal:
AutoCAD SHX Text
PLOT DATE:
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
USER NAME:
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 12'
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
TYP.
AutoCAD SHX Text A 12/20/19 35%35%
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B 03/19/20 95%95%
C 04/17/20 FINAL DESIGN SMTL. FINAL DESIGN SMTL.
T
A N
S M
M
M O
N
F
I R
E
A
L A
M
S
U P
E R
V I S
O R
Y
S
I G
N A
L
T
O
R
E C
E I V
E
B
S
E
R
E P
O R
T I N
G
S
Y S
T E
M
ALARM CONDITIONS
SYSTEM INPUT
GENERAL FIRE ALARM
A U
D I O
V
I S
U A
L
S
U P
E R
V I S
O R
Y
I N
D I C
A T
I O
N
T R
A N
S M
G
N
E R
A L
F
I R
E
A
L A
G
N A
L
T
O
R
E C
E I V
S
E
R
E P
O R
T I N
G
S
Y S
T E
M
A U
D I O
V
I S
U A
L
A
L A
D I C
A T
I O
N
T R
A N
S M
M
M O
N
F
I R
E
A
L A
O
U B
L
G
N A
L
C
E I V
S
E
R
E P
O R
T I N
G
S
Y S
T E
M
A U
D I O
V
I S
U A
L
T
R O
U B
D I C
A T
I O
N
BA C
SYSTEM OUTPUTS
NOTIFICATION
ANNUNCIATION
AT LOCAL PANEL
ED IHF G J K
FACP
FUNC
SMOKE DETECTOR (OVER FIRE ALARM PANEL OR REMOTE POWER SUPPLY)
MANUAL PULL STATION
C O
N T
R O
L
P
A N
E L
R
E T
U R
N
O R
M A
L
A
U D
I B
L E
S
A
D
V
S
U A
O
P
S I L E
N C
E
P
A N
E L
A
I L D
I N
G
F
I R
E
A
L A
D
I B
L E
V
I S
U A
L
N
O T
I F
I C
A T
I O
N
A
P P
L I A
N C
O
P
I N
I T
I A
R
E
A
L A
D
I B
V
S
I B
T
I F
I C
A T
I O
N
TROUBLE FUNCTIONS
COMMON TROUBLE
SUPERVISORY DEVICES
COMMON SUPERVISORY
FIRE ALARM SYSTEM LOW BATTERY
FIRE ALARM AC POWER FAILURE
GROUND FAULT
NOTIFICATION APPLIANCE CIRCUIT SHORT
OPEN CIRCUIT
PANEL FUNCTIONS
SYSTEM RESET
SYSTEM SILENCE
D I S
P L A
Y
D
E V
I C
E
A
D D
R E
S S
D I S
P L A
Y
T
R O
U B
N
D I T
I O
N
D I S
P L A
Y
S
U P
E R
V I S
O R
Y
C
O N
D I T
I O
N
BA C ED IHF G J LK
L
WATER FLOW FROM SPRINKLER SYSTEM
M
T R
A N
S M
W
T
O
W
S
I G
N A
L
T
O
R
E C
E I V
S
E
R
E P
O R
T I N
G
S
Y S
T E
M
SUPERVISED CONTROL VALVE OPERATIONS
M
I N
I T
I A
X T
E R
I O
R
E
L E
C T
R
W
T
E R
F L O
W
H
O R
N
N
N
0'-4" (MIN)
3'-0" (MIN)
M
A X
M
I N
SUPPLY OR RETURN
DIFFUSER
CEILING LINE
S I D
E
W
A L L
CEILING MOUNTED HEAT
DETECTOR ACCEPTABLE
HERE
NEVER HERE
WALL MOUNTED
HEAT DETECTOR
FINISHED
WALL
T
O
B
O T
T O
M
O
F
S
T R
O B
E
L E
N S
B
E L O
W
C
E I L N
G
CEILING MOUNTED
SMOKE/HEAT
DETECTOR
CEILING MOUNTED NOTIFICATION APPLIANCE
(INSTALL AT BOTTOM OF JOIST OR BEAM IF
OPEN AREA TO STRUCTURE)
FINISHED
WALL
FINISHED
FLOOR
F M
C P
FIRE ALARM/
MASS
NOTIFICATION
CONTROL
PANEL
M
A X
I M
U M
WALL MOUNTED
NOTIFICATION
APPLIANCE
WALL MOUNTED SMOKE
DETECTOR
M
A X
CEILING MOUNTED SMOKE DETECTOR
ACCEPTABLE TIGHT TO CORNER
SYNCHRONIZE
MORE THAN
TWO
APPLIANCES
IN ANY FIELD
OF VIEW
5'-0"
(MAX)
MANUAL PULL
STATION
O
P E
R A
B L E
P A
K
E Y
F-5.0
FIRE ALARM
DETAILS
SB
JO
JS
R E
P A
N
G A
R
F
A
V I O
N I C
S
S
H O
P
A L
A S
T
I O
N A
L
G
U A
R D
C
M
A I N
T E
N A
N C
E
C
O M
P L
E X
J O
I N
T
B
A S
E
E
L M
E N
D O
C
H A
R D
S O
N
J B
E R
FDZE3500
AS INDICATED
AREA OF SCOPE
EXISTING
FIRE ALARM SEQUENCE OF OPERATIONS DEVICE MOUNTING DETAIL
AutoCAD SHX Text Date
AutoCAD SHX Text Description
AutoCAD SHX Text By
AutoCAD SHX Text Revision:
AutoCAD SHX Text No.
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Drawing Title:
AutoCAD SHX Text Designed By:
AutoCAD SHX Text Jacobs Project No.:
AutoCAD SHX Text Scale:
AutoCAD SHX Text
2600 MICHELSON DRIVE, SUITE 500, IRVINE CA. 92612
AutoCAD SHX Text
(949) 224-7500 FAX (949) 224-7501
AutoCAD SHX Text Keyplan:
AutoCAD SHX Text Seal:
AutoCAD SHX Text
PLOT DATE:
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
USER NAME:
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A 12/20/19 35%35%
AutoCAD SHX Text B 03/19/20 95%95%
C 04/17/20 FINAL DESIGN SMTL. FINAL DESIGN SMTL.
OBSTRUCTION GREATER
THAN 48 IN WIDE OR WITHIN
18 IN OF SPRINKLER
OVERHEAD
UPRIGHT SPRINKLER
WITH HEAD GUARD
BRANCHLINE
1 IN DOWN TO SPRINKLER
BELOW OBSTRUCTION
1 IN GLOBE VALVE
1 IN PLUG
SURGE
RESTRAINER
SURGE
ROD
RESTRAINER
ALL THREAD
SURGE
RESTRAINER
NOTE: TO BE USED ONLY WITH BAND HANGERS TO RESTRAIN THE
UPWARD MOVEMENT OF PIPE AS IT OCCURS DURING SPRINKLER HEAD
ACTIVATION OR SEISMIC ACTIVITY. INSTALL AT THE END OF EACH BRANCH
LINE AND AT 30' INTERVALS ALONG BRANCH LINES PER NFPA 13.
FIG. 4A
PIPE CLAMP
FOR SWAY BRACE
BRACE PIPE
FIG. 910
SWIVEL SWAY
BRACE FITTING
FIG. 800
SWAY BRACE
ATTACHMENT TO
STEEL I-BEAM
FIG. 800
SWAY BRACE
ATTACHMENT TO
STEEL I-BEAM
FIG. 910
SWIVEL SWAY
BRACE FITTING
BRACE PIPE
FIG. 1000
"FAST CLAMP"
SWAY BRACE ATTACHMENT
ADJUSTABLE SWIVEL
RING HANGER
SPRING NUT
MAX SPAN 5'-0"
2"x2"x1/4"
PLATE WASHER
ALL THREAD ROD
DOUBLE NUT
ANGLE
IRON
FRAMING
CHANNEL
JOIST
BOTTOM
CHORD
BEAM CLAMP
RETAINING
STRAP
LOCK
NUT REQ'D
VIEW A-A
A
A
ALL THREAD ROD
ADJUSTABLE
RING HANGER
T
O
L
C
O
F-5.1
FIRE PROTECTION
DETAILS
SB
JO
JS
R E
P A
N
G A
R
F
A
V I O
N I C
S
S
H O
P
A L
A S
T
I O
N A
L
G
U A
R D
C
M
A I N
T E
N A
N C
E
C
O M
P L
E X
J O
I N
T
B
A S
E
E
L M
E N
D O
C
H A
R D
S O
N
J B
E R
FDZE3500
AS INDICATED
AREA OF SCOPE
EXISTING
SPRINKLER BELOW OBSTRUCTIONS SURGE RESTRAINER
LATERAL SWAY BRACE
LONGITUNITAL SWAY BRACEBEAM/TRUSS TRAPEZE HANGER BEAM/TRUSS HANGER
PENDENT/UPRIGHT SPRINKLER DETAIL
AutoCAD SHX Text
2 1/8" MAX.
AutoCAD SHX Text
1 3/8" MIN.
AutoCAD SHX Text
REDUCING COUPLING
AutoCAD SHX Text 2.3"
AutoCAD SHX Text
REDUCING COUPLING
AutoCAD SHX Text 2.3"
AutoCAD SHX Text
12" MAX
AutoCAD SHX Text
BOT OF DECK
AutoCAD SHX Text Date
AutoCAD SHX Text Description
AutoCAD SHX Text By
AutoCAD SHX Text Revision:
AutoCAD SHX Text No.
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Drawing Title:
AutoCAD SHX Text Designed By:
AutoCAD SHX Text Jacobs Project No.:
AutoCAD SHX Text Scale:
AutoCAD SHX Text
2600 MICHELSON DRIVE, SUITE 500, IRVINE CA. 92612
AutoCAD SHX Text
(949) 224-7500 FAX (949) 224-7501
AutoCAD SHX Text Keyplan:
AutoCAD SHX Text Seal:
AutoCAD SHX Text
PLOT DATE:
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
USER NAME:
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A 12/20/19 35%35%
AutoCAD SHX Text B 03/19/20 95%95%
C 04/17/20 FINAL DESIGN SMTL. FINAL DESIGN SMTL.
| G-1.0 |
| A-0.1 |
| A-0.2 |
| A-0.3 |
| A-0.4 |
| A-0.5 |
| A-0.6 |
| FXSB172828_Hangar 12_100%_Mechanical Submittal.pdf |
| FXSB172828_M1.0 Layout |
| FXSB172828_M1.1 Layout |
| FXSB172828_M-0 Layout |
| FXSB172828_M-5.0 Layout |
| FXSB172828_M-6.0 Layout |
| FXSB172828_Hangar 12_100% Fire Protection Submittal.pdf |
| F-0.1 |
| Sheets and Views |
| Arch D |
| F-1.0 |
| Sheets and Views |
| Arch D |
| F-2.0 |
| Sheets and Views |
| Arch D |
| F-5.0 |
| Sheets and Views |
| Arch D |
| F-5.1 |
| Sheets and Views |
| Arch D |