This document is a performance specification for a YLAA0155SJ46VSD air-cooled scroll chiller model. The specification details the chiller's technical specifications, including cooling capacity, power input, efficiency ratings, electrical data, dimensional and weight information, and part load performance data. It also provides sound power level data for the unit at various load conditions. The chiller is compliant with relevant industry standards. The document includes an AVM report providing the center of gravity and weights for the unit, as well as a 2D drawing showing the dimensions and clearance requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| NH014-Londonderry-A3-CSS-93937-YLAA IOM- Manual- Repair Chiller-yes.pdf | ||
| QtAs - W15QKN-24-R-5031.docx | DOCX document | |
| W15QKN-24-R-5031_0001.pdf | ||
| NH014-Londonderry-A3-CSS 93937-SOW-Repair Chiller.docx | DOCX document | |
| Contractor Cost Breakdown Form (NOV 2022).xlsx | XLSX spreadsheet | |
| W15QKN-24-R-5031.pdf | ||
| DBA NH20240022 (Mod. 0) 1-5-2024.pdf | ||
| SF1413 Statement of Acknowledgement.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Full Load - Design
PIN
YLAA0155SJ 46XFBBCTXA SXBLXCXX44 SE1XXXHXXX YAXGXXX3XX XVXNXXXXXX
....5...10 ....5...20 ....5...30 ....5...40 ....5...50 ....5...60 ....5...70 ....5...80 ....5...90
Unit
Model No. YLAA0155SJ46XFB
Number of Compressors 5
Compressor Type Scroll - Hermetic
Number of Compressor Circuits 2
Refrigerant R454B
Performance Data
Cooling Capacity [tons.R] 143.2
Total Power Input [kW] 173.0
EER [Btu/W.h] 9.932
IPLV.IP [Btu/W.h] 17.75
A-Weighted Sound Power [dB(A)] 97.0
Electrical Data
Nominal Voltage / Voltage Limits 460/3/60 / 414-506
Compressor RLA (each circuit) [A] 53.1 / 53.1 / 53.1 / 53.1 / 53.1 / -
High LRA Current (each circuit) [A] 316.0 / 316.0 / 316.0 / 316.0 / 316.0 / -
Fan QTY (each circuit) 4 / 4
Fan FLA (each circuit) [A] 4.0 / 4.0
Min. Circuit Ampacity [A] 315.0
Recommended Fuse / CB Rating [A] 350.0
Max. Inverse Time CB Rating [A] 350.0
Max. Dual Element Fuse Size [A] 350.0
Unit Short Circuit Withstand [kA] 65 kA
Wires Per Phase 2 + 3
Wire Range (Lug Size) 250 - 500 kcmil + #2/0 AWG - 400 kcmil
Compressor kW 159.5
Performance Impacting Options
Starter Type Across the line starter
Power Factor Correction Capacitor No Power Capacitor required
Remote Evaporator Standard Cooler required
Sound Kit No Acoustic Blanket required
Fan Low Sound Fans with VSD
Weight & Dimensional Data
Shipping Weight [lbs] 7044
Operating Weight [lbs] 7154
Refrigerant Charge [lbs] 122
Length [in] 187.7
Width [in] 88.3
Height [in] 94.2
Performance Report Performance Specification
Project Name: 454B Stock AC Scrolls YLAA Submittals
Unit Tag:
YLAA0155SJ46VSD Qty.: 1 Model: YLAA0155SJ46XF
Project Name: 454B Stock AC Scrolls YLAA Submittals
Rating Engine Version: REV.v9_12.idd Version: SN23.02 Generated: 2023/05/03 at 11:33
Unit Name: YLAA0155SJ46VSD Version: CHL.2023-02.001 Page 1 of 4
Heat Exchanger Performance
Evaporator Condenser (Air Cooled)
Heat Exchanger Type Plate Heat Exchanger Ambient Air Temperature* [ºF] 95.0
Entering Fluid Temperature* [ºF] 54.00 Altitude* [ft] 0.00
Leaving Fluid Temperature* [ºF] 44.00 Condensing Temperature [ºF] 127.32 / 118.56
Flow Rate [USGPM] 341.7 Number of Fans 4 / 4
Fouling Factor* [h ft2 F/Btu] 0.000100 Total Air Flow [cfm] 120000
Fluid Type* Water Total Fan Power [kW] 13.44
Fluid Volume [USGAL] 13.2
Evaporating Temperature [ºF] 39.42
Evaporator Pressure Drop [ft H2O] 11.9
Strainer Pressure Drop [ft H2O] 3.07
Extension Kit Pressure Drop [ft H2O] 7.11
Total Pressure Drop [ft H2O] 22.0
Fluid Connection Diameter [in] 4
Minimum Flow Rate [USGPM] 150.0
Maximum Flow Rate [USGPM] 625.0
* Designates user specified input
Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.
Part Load Performance (Based on Standard AHRI Unloading)
Percent Load Ambient [ºF] Capacity [tons.R] Power Input [kW] Unit Efficiency [Btu/W.h]
100.0 95.0 143.2 173.0 9.932
90.4 80.0 129.4 110.8 14.02
66.9 80.0 95.79 79.36 14.48
73.0 65.0 104.5 68.69 18.26
48.5 65.0 69.46 41.92 19.89
51.2 55.0 73.24 38.50 22.83
24.2 55.0 34.63 18.26 22.76
Project Name: 454B Stock AC Scrolls YLAA Submittals
Unit Tag:
YLAA0155SJ46VSD Qty.: 1 Model: YLAA0155SJ46XF
Unit Name: YLAA0155SJ46VSD Version: CHL.2023-02.001 Page 2 of 4
Sound Power Levels (In Accordance with AHRI 370)
Percent Load Ambient [ºF] Octave Band Center Frequency [Hz]
LWA
63 125 250 500 1000 2000 4000 8000
100.0 95.0 99.0 98.0 94.0 95.0 92.0 88.0 85.0 82.0 97.0
90.4 80.0 94.0 93.0 89.0 90.0 88.0 85.0 81.0 79.0 93.0
66.9 80.0 90.0 89.0 85.0 87.0 86.0 83.0 79.0 77.0 90.0
73.0 65.0 81.0 63.0 76.0 84.0 85.0 81.0 78.0 76.0 88.0
48.5 65.0 80.0 62.0 74.0 82.0 83.0 80.0 76.0 75.0 87.0
51.2 55.0 80.0 62.0 74.0 82.0 83.0 80.0 76.0 75.0 87.0
24.2 55.0 77.0 59.0 71.0 79.0 80.0 77.0 73.0 72.0 84.0
Note:Unit is equipped with Low Sound Fans with VSD.
Measurement of sound pressure used to obtain the sound power data presented is based on AHRI-370.
Air-cooled chillers are rated in terms of sound power not sound pressure. Johnson Controls provides estimates of sound pressure, but this is not the rating metric.
For an air-cooled chiller, sound pressure calculated from sound power varies depending on how the chiller is assumed to behave, i.e. the radiation model. In other words, determining sound pressure from sound power requires making assumptions that result in different answers at a given distance from the chiller. The environment also influences sound pressure in the field installation. Sound pressure estimation radiation models pertaining to air-cooled chillers include the ‘traditional’ hemispherical model, parallelepiped model and equivalent hemispherical model.
Regarding sound power, Johnson Controls references tolerance limits based on ASHRAE guidelines. These are +/- 6dB in the 63Hz octave band, +/- 4dB in all other octave bands and +/- 3dB for the overall dBA.
Tolerance limits are based on uncertainties associated with:
1. Measurement Test Procedure
2. Repeatability
3. Production / Manufacturing Variability
Standard deviation associated with air-cooled chiller sound data is a measure of spread i.e. it indicates the range of probability of sound levels. Note that for operating conditions other than AHRI’s Standard Rating Condition, higher levels of uncertainty can be expected.
Lead times for factory performance testing depend on test laboratory availability. Please confirm with Johnson Controls Customer Service.
Performance at AHRI Conditions
Evaporator Condenser
EFT [ºF] 54.00 Ambient Temp. [ºF] 95.0
LFT [ºF] 44.00 Altitude [ft] 0.00
Flow Rate [USGPM] 341.7 Performance
Pressure Drop [ft H2O] 11.9 EER [Btu/W.h] 9.932
Fluid Type Water IPLV.IP [Btu/W.h] 17.75
Fouling Factor [h ft2 F/Btu] 0.000100 Net Cooling Capacity [tons.R] 143.2
Fluid Volume [USGAL] 13.2
Note:Unit rated at design condition capacity.
Project Name: 454B Stock AC Scrolls YLAA Submittals
Unit Tag:
YLAA0155SJ46VSD Qty.: 1 Model: YLAA0155SJ46XF
Unit Name: YLAA0155SJ46VSD Version: CHL.2023-02.001 Page 3 of 4
Part Load Performance (Based on AHRI 550/590 - 2018 (IP))
Percent Load Ambient [ºF] Capacity [tons.R] Power Input [kW] Unit Efficiency [Btu/W.h]
100.0 95.0 143.2 173.0 9.932
90.4 80.0 129.4 110.8 14.02
66.9 80.0 95.79 79.36 14.48
73.0 65.0 104.5 68.69 18.26
48.5 65.0 69.46 41.92 19.89
51.2 55.0 73.24 38.50 22.83
24.2 55.0 34.63 18.26 22.76
Notes:
Country of Origin:Mexico
Min flow rate is for chillers using water. For glycol chillers please contact the application engineering team.
This unit does not have a coil coating selected.
Compliant with ASHRAE 90.1 - 2010,2013,2016.
Compliant with IECC - 2012,2015,2018.
Compliant with the requirements of the LEED Energy and Atmosphere Enhanced Refrigerant Management Credit (EAc4).
The product image shown is for illustrative purposes only and is not representative of selected options.
Project Name: 454B Stock AC Scrolls YLAA Submittals
Unit Tag:
YLAA0155SJ46VSD Qty.: 1 Model: YLAA0155SJ46XF
Unit Name: YLAA0155SJ46VSD Version: CHL.2023-02.001 Page 4 of 4
PIN
YLAA0155SJ 46XFBBCTXA SXBLXCXX44 SE1XXXHXXX YAXGXXX3XX XVXNXXXXXX
....5...10 ....5...20 ....5...30 ....5...40 ....5...50 ....5...60 ....5...70 ....5...80 ....5...90
LOCATION X Distance (in) Y Distance (in) JCI PART NUMBER SAP NUMBER COLOUR Operating Weights (lb)
R1 7.7 1.4 029-25335-001 434002 Charcoal 733
R2 76.7 1.4 029-25335-002 434004 Red 1321
R3 152.2 1.4 029-25335-002 434004 Red 990
L1 7.7 86.9 029-25335-002 434004 Red 974
L2 76.7 86.9 029-25335-004 434005 Charcoal 2076
L3 152.2 86.9 029-25335-002 434004 Red 1059
Total Weight (lb) Centre of Gravity (in)
Operating Weights (lb) 7153 Xg [in] 81.9
Shipping Weight [lb] 7044 Yg [in] 50.5
YLAA Air Cooled Scroll Chillers AVM Report
Project Name: 454B Stock AC Scrolls YLAA Submittals
Unit Tag:
YLAA0155SJ46VSD Qty.: 1 Model No.: YLAA0155SJ46XF
Version: SN23.02 Generated: 05/03/2023 at 11:33
Unit Name: YLAA0155SJ46VSD Version: CHL.2023-02.001 Page 1 of 1
A
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
B
C
D
E
F
G
H
I
J
K
L
A
B
C
D
E
F
G
H
I
J
K
L
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
THIRD ANGLE
ReleasedSHEET 1 OF 1 ORIG. NO.:MASS (kg): 0.000SCALE: 0.060
VERSION
DRAWING NUMBER
035-24059-010
CAGE NUMBER
66935A1
ENG
06-DEC-2013 A.SAYCH CHKD
REVISION
H
06-DEC-2013 M.LUPTON MODELER
N/A CUT SIZE
YLAA 8-FAN 50 & 60HZ
WITH HEAT RECOVERY
06-DEC-2013 M.LUPTON DRAWN
PART NO.
DO NOT SCALE
N/A ENG. STD.
N/A MATERIAL
JOHNSON CONTROLS - BUILDING EFFICIENCY
507 EAST MICHIGAN STREET, MILWAUKEE, WI, 53202 USA
"ALL PROPRIETARY RIGHTS IN
THE SUBJECT MATTER HEREOF
ARE RESERVED AND NO
PERMISSION IS GRANTED TO
REPRODUCE THIS PRINT IN
WHOLE OR IN ANY PART, OR
DISCLOSE ANY OF THE
INFORMATION UPON IT TO
OTHERS WITHOUT WRITTEN
RELEASE BY JOHNSON
CONTROLS INCORPORATED"
CO
NI
TN
UE
D
RE
VI
SI
ON NOTE 6 AMENDED DIM 2541MM WAS 2535MM. FAN TERMINAL BOX 6MM HIGHER.
XWAS GT ECN20-0441 09-JUN-2020 H
ENG.CHK.DR.EC. NO.DATEREV.THIS DRAWING PERTAINS TO THE FOLLOWING MODELS:
YLAA 0125 HE YLAA 0150 SE YLAA 0516 HE
YLAA 0136 SE YLAA 0155 SE YLAA 0517 HE
YLAA 0139 HE YLAA 0456 HE YLAA 0457 HJ
YLAA 0142 HE YLAA 0457 HE YLAA 0517 HJ
MODEL NUMBER DIMENSION "A"
YLAA 0125 HE 221 [8.7]
YLAA 0136 SE 221 [8.7]
YLAA 0139 HE N/A
YLAA 0142 HE 221 [8.7]
YLAA 0150 SE 148 [5.8]
YLAA 0155 SE 148 [5.8]
YLAA 0456 HE 221 [8.7]
YLAA 0457 HE 221 [8.7]
YLAA 0457 HJ 221 [8.7]
YLAA 0516 HE 221 [8.7]
YLAA 0517 HE 221 [8.7]
YLAA 0517 HJ 221 [8.7]
NOTES:
1. PLACEMENT ON A LEVEL SURFACE FREE OF OBSTRUCTIONS (INCLUDING SNOW, FOR WINTER
OPERATION) OR AIR-CIRCULATION ENSURES RATE PERFORMANCE, RELIABLE OPERATION
AND EASE OF MAINTENANCE. SITE RESTRICTIONS MAY COMPROMISED MINIMUM CLEARANCES
INDICATED BELOW, RESULTING IN UNPREDICTABLE AIR FLOW PATTERNS AND POSSIBLE
DIMINISHED PERFORMANCE. JOHNSON CONTROLS UNIT CONTROLS WILL OPTIMIZE OPERATION
WITHOUT NUISANCE HIGH PRESSURE SAFETY CUTOUT. HOWEVER, THE SYSTEM DESIGNER
MUST CONSIDER POTENTIAL PERFORMANCE DEGRADATION.
1.1. RECOMMENDED MINIMUM CLEARANCES:
1.1.1. SIDE TO WALL - 1828.8mm[72.00]
1.1.2. REAR TO WALL - 1828.8mm[72.00]
1.1.3. CONTROL PANEL TO WALL - 1219.2mm[48.00]
1.1.4. TOP - NO OBSTRUCTIONS ALLOWED.
1.1.5. DISTANCE BETWEEN ADJACENT UNITS - 3048mm[120.00]
1.1.6. NO MORE THAT ONE ADJACENT WALL MAY BE HIGHER THAN UNIT.
2. WEIGHT AND CENTRE OF GRAVITY- REF TO AVM REPORT
3. INSTALLING CONTRACTOR MUST INCLUDE VENT AND DRAIN ACCOMMODATIONS IN CHILLED
WATER PIPING NEAR EVAPORATOR.
4. NUMBER OF COMPRESSORS MAY VARY FROM DRAWING.
4.1. REFER TO YORKWORKS REPORTS
5. OVERALL HEIGHT OF UNIT IS 2394.6mm-[94.27"] ON MONTERREY, MEXICO AND SAN ANTONIO, TEXAS BUILDS AND EUROPEAN BUILDS (VSD FANS ONLY).
6. ON EUROPEAN BUILDS, OVERALL HEIGHT OF UNIT IS 2507.0mm [98.70"] WITH STANDARD FANS AND IS 2541.0mm [100.04"] WITH LOW AMBIENT KIT AND WITH C FAN.
7. FOR MONTERREY, MEXICO, SAN ANTONIO, TEXAS AND EUROPEAN BUILDS ONLY.
3" VICTAULIC INLET
3" VICTAULIC OUTLET
4" VICTAULIC
INLET
4" VICTAULIC
OUTLET
MOUNTING
HOLES TYP
(OPTIONAL HEAT
RECOVERY UNIT)
POWER ENTRY
330.2[13.00] WIDE X 177.8[7.00] HIGH
CONTROL PANEL BOTTOM DETAIL
FRAME WIDTH
2242 88.3[ ]
OVERALL WIDTH
2256 88.8[ ]
F R A M E
H E I G H T
O V E R A L L
H E I G H T
D E P E N D S
O N
B U I L D
L O C A T I O N
R E F E R
T O
N O T E S
A N D
A B O V E
OVERALL LENGTH
4763 187.5[ ]
FRAME LENGTH
4731 186.3[ ]
588 23.2[ ] 1473 58.0[ ] 1519 59.8[ ]
"A"
(OPTIONAL HEAT
RECOVERY UNIT)
WATER CONNECTIONS
137 5.4[ ]
WATER CONNECTIONS
3845 151.4[ ]
195 7.7[ ] 1753 69.0[ ] 1918 75.5[ ]
MOUNTING
HOLES TYP
36 1.4[ ]
MOUNTING
HOLES TYP
36 1.4[ ]
1177.0 [46.35]
1256 49.5[ ]
562 22.1[ ]
1679 66.1[ ]
2796 110.1[ ]
3913 154.1[ ]
| 454B Stock AC Scrolls - YLAA0155SJ46VSD - Performance Report.PDF (p.1-4) |
| 454B Stock AC Scrolls - YLAA0155SJ46VSD - AVM Report.PDF (p.5) |
| 454B Stock AC Scrolls - YLAA0155SJ46VSD - Chillers - YLAA - 035-24059-010 -2D Drawings.PDF (p.6) |
| Sheet 1 |
| new_view_2 |
| bottom_3 |
| left_4 |
| right_5 |
| new_view_7 |
File details come from the government source that posted it. Updated .