WV009_-_Clarksburg_-_C09_-_CSS_9242-_Storm_Drain_Test_Data_-_Repair_Storm_Drainage.pdf

PDF 764 KB Posted

Attached to
Repair Drain Storm System - Clarksburg, WV
Solicitation number
W15QKN-19-Q-1289
Issued by

About this file

WV009 - Clarksburg - C09 - CSS 9242- Storm Drain Test Data - Repair Storm Drainage

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX A

Photolog

Client Name:

United States Army Corps of Engineers, Mobile

Project Location:

AMSA #102, Clarksburg, West Virginia

Stell Project No.: 1394

Photograph No.

1.

Date:

4/28/15

Direction Photo Taken:

Southeast

Description:

View of smoke testing manhole SDMH-1 with smoke coming out of SD-1.

Photograph No.

2.

Date:

4/28/15

Direction Photo Taken:

Southeast

Description:

View of smoke coming out of Outfall-1 located in the retention pond when smoke testing manhole SDMH-1.

Mobile

Project Location:

AMSA #102, Clarksburg, West Virginia

Stell Project No.: 1394

Photograph No.

3.

Date:

4/28/15

Direction Photo Taken:

Northwest

Description:

View of some coming out of a storm drain located in the POV lot when smoke testing manhole SDMH-1.

Photograph No.

4.

Date:

4/28/15

Direction Photo Taken:

South

Description:

View of smoke testing roof drain W-1. Smoke was coming back out of roof drain W-1 indicating a block in the drainage system.

Mobile

Project Location:

AMSA #102, Clarksburg, West Virginia Stell Project No.: 1394

Photograph No.

5.

Date:

4/28/15

Direction Photo Taken:

Southwest

Description:

View of new storm inlets installed along west side of the AMSA shop. It was determined that the roof drains along the west side of the AMSA shop do not connect to drainage system but stop at the end of the concrete pad.

Photograph No.

6.

Date:

4/28/15

Direction Photo Taken:

Description:

Mobile

Project Location:

AMSA #102, Clarksburg, West Virginia Stell Project No.: 1394

Photograph No.

7.

Date:

4/28/15

Direction Photo Taken:

South

Description:

View of roof drain W-4 which was smoke tested. A video camera was also inserted into W-4 to locate the blockage in the drainage system. The OWS is located to the left in the picture.

Photograph No.

8.

Date:

4/28/15

Direction Photo Taken:

South

Description:

View of OWS located off the east side of the AMSA shop.

APPENDIX B

Field Notes

File details come from the government source that posted it.