DWG_CAD-Ramp_(NY054-Plattsburgh_CSS_9246_).pdf
PDF 526 KB Posted
- Attached to
- Install Handicapped Ramps, Plattsburgh, PA Federal contract opportunity
- Solicitation number
- W15QKN-19-Q-1257
About this file
CAD Drawing for the ramp placements
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| NY054-Plattsburgh-A1-CSS_9246-FP_Details-Ramp.pdf | ||
| W15QKN-19-Q-1257_0004.pdf | ||
| Responses_to_Questions_1_thru_22_on_CSS_9246_Ramp_Plattsburg_NY.docx | DOCX document | |
| W15QKN-19-Q-1257_0003.pdf | ||
| ADDITIONAL_SITE_VISIT.docx | DOCX document | |
| W15QKN-19-Q-1257_0001.pdf.docx | DOCX document | |
| W15QKN-19-Q-1257.pdf | ||
| Construction_Itemization_Template.xlsx | XLSX spreadsheet | |
| SOW_Ramp_Installation,_Plattsburgh,_NY054_CSS_9246.docx | DOCX document | |
| DWG_CAD-Ramp_(NY054-Plattsburgh_CSS_9246_).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FACID:
DESIGNED:
** NOT FOR CONSTRUCTION - ALL CONDITIONS MUST BE SITE VERIFIED **
REV 0:
DPW - CAD/ GIS BRANCH
99th READINESS DIVISION
SCALE:
CAD/GIS PROJ:CHECKED:
FIELD VERIFIED:
DATE:
SHEET:
REV:
DWG NO:
1 OF 5SJS NTS
EMZ G-1
NY054 (36930)
18-15
SJS
DRAWN LMC
INSTALL NEW RAMPS
NY054 (36930)/ PFC HAROLD P. LYNCH USARC
DRAWING LIST
G-1
2 OF 5 A-1
3 OF 5 A-2
A-4
SCALE: NTS
USARC - PROJECT LOCATIONS
SCALE: NTS
A-3
TITLE SHEET
INTERIOR ELEVATIONS
EXTERIOR ELEVATIONS
TITLE SHEET
INTERIOR STAIRWELL - EXISTING / NEW WORK PLAN
EXTERIOR ENTRANCE - EXISTING / NEW WORK PLAN
NY054/ PLATTSBURGH, NY - VICINITY MAP
NY054 (36930) / PFC HAROLD P. LYNCH USARC - PLATTSBURGH, NY
INITIAL RELEASE
PFC HAROLD P. LYNCH USARC
SEE SHEETS 2 AND 3
SEE SHEETS 4 AND 5
20JUL18
20JUL18
** NOT FOR CONSTRUCTION - ALL CONDITIONS MUST BE SITE VERIFIED **
REV 0:
DPW - CAD/ GIS BRANCH
99th READINESS DIVISION
SCALE:
CAD/GIS PROJ:CHECKED:
FIELD VERIFIED:
DATE:
SHEET:
REV:
DWG NO:
2 OF 5SJS NTS
EMZ A-1
LEGEND
NY054 (36930)
18-15
SJS
DRAWN LMC
INSTALL NEW RAMPS
NY054 (36930)/ PFC HAROLD P. LYNCH USARC
SCULLERY
VAULT
OFFICE
SERGEANT'S
CORRIDOR
ASSEMBLY
SCULLERY
VAULT OFFICE
SERGEANT'S
CORRIDOR
ASSEMBLY
USARC - BUILDING
STAIRWELL
INTERIOR
INTERIOR STAIRWELL - EXISTING PLAN INTERIOR STAIRWELL - NEW WORK PLAN
EXTINGUISHEREXTINGUISHER
RAILING
GRAPHIC SCALE
5'0 10' 20'ENTRANCE
MAIN
TO BE REMOVED
AND RAILING
EXISTING STAIRS
ENTRANCE
POV PARKING
ASSEMBLY DOOR SWING
5'-0" CLEARANCE FROM
TO BE REMOVED
NEW WORK
EXISTING
INSTALL NEW RAILINGS
PULL STATION
OUTLET BOX
PULL STATION
TO BE REMOVED
STORE FRONT
EXISTING
TO BE REMOVED
ACM TILE & MASTIC
APPROX. 250 SF OF
DOOR #1
DOOR #2
NEW STORE FRONT
NOTES:
OUTLET BOX
COLOR TO BE DETERMINED BY AFOS
NEW VINYL TILE
INTERIOR STAIRWELL - EXISTING / NEW WORK PLAN
TO BE REPLACED
ASSEMBLY DOORS
5'-0" CLEARANCE
NEW FIRE RATED DOORS
SEE NOTE 1
HEATER/ PIPING
SEE NOTE 1
HEATER/ PIPING
DOOR #1
NEW FIRE RATED
EXTERIOR DOOR #2
NEW FIRE RATED
AS PART OF THIS PROJECT
DAMAGED DUE TO WORK PERFORMED
TO ENSURE PIPING & HEATER ARE NOT
1. CONTRACTOR MUST TAKE MEASURES
INITIAL RELEASE
TO BE REMOVED
CORRIDOR DOORS AND FRAME SEE NOTE 2
EXISTING WALL CONDITIONS AND COLOR
PATCH EXISTING CORRIDOR ENTRY TO MATCH
2. IN AREA OF REMOVED DOORS AND FRAME
A-2 B
A-2 A
A A-2
B A-2
A-2
DC
A-2
C A-2
D A-2
2'-4"
6'-0"
20JUL18
20JUL18
UP
RAMP
39'-3"
19'-2"
6'-4"
5'-4"
5'-4"
10"
1'-6"
** NOT FOR CONSTRUCTION - ALL CONDITIONS MUST BE SITE VERIFIED **
REV 0:
DPW - CAD/ GIS BRANCH
99th READINESS DIVISION
SCALE:
CAD/GIS PROJ:CHECKED:
FIELD VERIFIED:
DATE:
SHEET:
REV:
DWG NO:
3 OF 5SJS NTS
EMZ A-2
LEGEND
NY054 (36930)
18-15
SJS
DRAWN LMC
INSTALL NEW RAMPS
NY054 (36930)/ PFC HAROLD P. LYNCH USARC
EXTINGUISHER
EXISTING STAIR ELEVATION (SOUTH)
EXISTING STAIR ELEVATION (NORTH)
RAILING
RAILING
DOOR SWING
OF EXISTING
EXTENT
20'10'0 5'
NEW RAMP ELEVATIONS (SOUTH)
NEW RAMP ELEVATIONS (NORTH)
OUTLET BOX
TO BE REMOVED
RAILING
PULL STATION
EXTINGUISHER
PULL STATION
OUTLET BOX
TO BE REMOVED
NEW WORK
EXISTING
INSTALL NEW RAILINGS
GRAPHIC SCALE
DOOR #1
DOOR #2
DOOR #1
FIRE RATED
DOOR SWING
OF NEW ASSEMBLY
EXTENT
INTERIOR ELEVATIONS
DOOR #2
FIRE RATED
REPLACED
DOORS TO BE
ASSEMBLY ASSEMBLY DOORS
FIRE RATED
BE REMOVED
DOORS TO
CORRIDOR
HEATER/ PIPING
PROTECT
(WINDOW)(WINDOW)
(WINDOW) (WINDOW)
HEATER/ PIPING
PROTECT DOORS
ASSEMBLY
FIRE RATED
INITIAL RELEASE
A-1
CA
A-1
B A-1 A-1
D
20JUL18
20JUL18
24'-0"
4'-8"
8'-5"
9'-8"
7'-7"
17'-4"
1'-0"
11"
3'-0" 3"
24'-0"
39'-3"
** NOT FOR CONSTRUCTION - ALL CONDITIONS MUST BE SITE VERIFIED **
REV 0:
DPW - CAD/ GIS BRANCH
99th READINESS DIVISION
SCALE:
CAD/GIS PROJ:CHECKED:
FIELD VERIFIED:
DATE:
SHEET:
REV:
DWG NO:
4 OF 5SJS NTS
EMZ A-3
LEGEND
NY054 (36930)
18-15
SJS
DRAWN LMC
INSTALL NEW RAMPS
NY054 (36930)/ PFC HAROLD P. LYNCH USARC
EXTERIOR - EXISTING PLAN EXTERIOR - NEW WORK PLAN
INTERCOM
CAC READER/
USARC BUILDING
E
DOWN
RAMP
NOTES:
LANDING
CONCRETE
SEE NOTE 1
RAILING
12'-0"
11'-2"
8'-8"
10' 20'5'0
GRAPHIC SCALE
ENTRANCE
MAIN
ENTRANCE
POV PARKING
TO BE REMOVED
POLE FROM GROUND
TO BE REMOVED
CONCRETE LANDING VEST.
VEST.
TO BE REMOVED
NEW WORK
EXISTING
INSTALL NEW RAILINGS
EXTERIOR ENTRANCE - EXISTING / NEW WORK PLAN
RAIL SECTION
6' REMOVABLE
APPROX. 96 SF
AND REPLACED WITH GRASS
SIDEWALK TO BE REMOVED
6" INTO CONCRETE RAMP
- VERTICAL RAILING POSTS TO BE EMBEDDED
AT LEAST 12" BEYOND INSIDE SURFACE OF HANDRAILS
- LANDING SURFACES MUST EXTEND
TO APPLICABLE ADA STANDARDS
1. EXTERIOR RAILINGS PLACED ACCORDING
TO MATCH SURROUNDING GRADE
FINAL GRADE ELEVATION
AREA OF NEW GRASS
16'-0" +/-
6'-0"
INITIAL RELEASE
10'-0"
4'-8"
A-4
F A-4
20JUL18
20JUL18
6'-0"
6'-0" 5'-0"
6" 6"
6"
6"
** NOT FOR CONSTRUCTION - ALL CONDITIONS MUST BE SITE VERIFIED **
REV 0:
DPW - CAD/ GIS BRANCH
99th READINESS DIVISION
SCALE:
CAD/GIS PROJ:CHECKED:
FIELD VERIFIED:
DATE:
SHEET:
REV:
DWG NO:
5 OF 5SJS NTS
EMZ A-4
LEGEND
NY054 (36930)
18-15
SJS
DRAWN LMC
INSTALL NEW RAMPS
NY054 (36930)/ PFC HAROLD P. LYNCH USARC
INTERCOM
EXISTING ENTRY (EXTERIOR)
EXTERIOR ELEVATIONS
CAC READER
INTERCOM
CAC READER
NEW WORK - ENTRY RAMP (EXTERIOR)
1'-0"
1'-0"
10'-0" 12'-0"
5'0 10' 20'
GRAPHIC SCALE
SIDEWALK
TO BE REMOVED
NEW WORK
EXISTING
SCALE: NTS
RAILING DETAIL (REF)
SEE DETAIL 1
* RAILING OMITTED FOR CLARITY
CONCRETE
APPROX. 96 SF
AND REPLACED WITH GRASS
SIDEWALK TO BE REMOVED
EXISTING GRASS AREA
EXISTING GRASS AREA
NEW GRASS AREA16'-0" +/-
INITIAL RELEASE
E A-3
F A-3
20JUL18
20JUL18
7'-0"
6'-0"
5'-10"
11"
8"
11'-2"
TO BE REMOVED
POLE FROM GROUND
6"
EMBEDDED 6" INTO CONCRETE RAMP
VERTICAL RAILING POSTS TO BE
| NY054_01_InstallNewRamp_JUL18 |
| NY054_02_InstallNewRamp_JUL18 |
| NY054_03_InstallNewRamp_JUL18 |
| NY054_04_InstallNewRamp_JUL18 |
| NY054_05_InstallNewRamp_JUL18 |
File details come from the government source that posted it.