W-2610C Plan.pdf
PDF 4 MB Posted
- Attached to
- 1714 South 4th Street Taps
- Solicitation number
- W-2613C
- Issued by
- Garfield County, Oklahoma
About this file
Water Infrastructure Project Specification
This document is a project specification and bidding sheet for a water main installation and repair project located at 1726 S. Leona Mitchell Boulevard. The project involves installing and repairing water infrastructure including PVC pipe, service lines, gate valves, and associated fittings along S. 4th Street and connecting properties. The estimate quantity sheet lists 13 line items with quantities including 40 linear feet of 6" and 8" C900 PVC pipe, 40 linear feet of 2" polyethylene service lines, 351 pounds of ductile iron fittings, one 6" gate valve and box assembly, one 2" valve and box assembly, one 1.5" valve and box assembly, pressure testing and disinfection services, field locating and tie-in work to existing waterlines, concrete sidewalk repair totaling 5 square yards, and solid slab sodding of 27 square yards. The project includes provisions for mobilization and notes that any additional materials or labor required to complete the work shall be considered incidental to the project.
The specification drawing provides detailed engineering plans showing three bore locations with specific pipe sizes, depths, and gate valve configurations at designated stationing points along the project corridor. The work involves boring operations under existing structures to install new water infrastructure, with field location and tie-in requirements to existing 1.5-inch and 2-inch waterlines at multiple connection points. No specific pricing terms, bid due dates, site visit schedules, or award dates are indicated within the visible portions of this document.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Feet 0 50 100
AutoCAD SHX Text
S. 4TH ST.
AutoCAD SHX Text
S. 4TH ST.
AutoCAD SHX Text 12"x1 " TAP 12" TAP BORE 40 FT 1 " PEX 12" PEX PEX 1 " GATE VALVE12" GATE VALVE
AutoCAD SHX Text
FIELD LOCATE AND TIE INTO EXT. 1 " FIRELINE12 " FIRELINE
AutoCAD SHX Text
FIELD LOCATE AND TIE INTO EXT. 2" FIRELINE
AutoCAD SHX Text 12"x2" TAP BORE 40 FT 2" PEX 2" GATE VALVE
AutoCAD SHX Text 12"x6" TEE BORE 40 FT 6" PVC 6" GATE VALVE
AutoCAD SHX Text 2-6"x45° BENDFIELD LOCATE AND TIE INTO EXT. FIRELINE
AutoCAD SHX Text
1714 S. 4TH ST.
AutoCAD SHX Text
1804 S. 4TH ST.
AutoCAD SHX Text
1726 S LEONA MITCHELL BLVD
AutoCAD SHX Text 12"x6" TEE BORE 40 FT 6" PVC 6" GATE VALVE
AutoCAD SHX Text 12"x1 " TAP 12" TAP BORE 45 FT 1 " PEX 12" PEX PEX 1 " GATE VALVE12" GATE VALVE
AutoCAD SHX Text 12"x1 " TAP 12" TAP BORE 40 FT 2" PEX 2" GATE VALVE
AutoCAD SHX Text 401 West Owen K. Garriott Road
AutoCAD SHX Text P.O. Box 1768
AutoCAD SHX Text Enid, Oklahoma 73702
AutoCAD SHX Text Date:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Cad File:
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text Designed By:
AutoCAD SHX Text Approved By:
AutoCAD SHX Text Sheet:
AutoCAD SHX Text of
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text Number
AutoCAD SHX Text Date
AutoCAD SHX Text Description
AutoCAD SHX Text The City Of Enid
AutoCAD SHX Text Tele: (580) 234-0400 Fax: (580) 234-8946
AutoCAD SHX Text %%uContacts:
AutoCAD SHX Text Project Number:
AutoCAD SHX Text Project Location:
AutoCAD SHX Text Engr. Seal:
AutoCAD SHX Text Sheet Title:
AutoCAD SHX Text Project Title:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OCT 2025
AutoCAD SHX Text 1" = 40'
AutoCAD SHX Text
TN
AutoCAD SHX Text
TN
AutoCAD SHX Text
JU
AutoCAD SHX Text
PLAN & PROFILE
AutoCAD SHX Text
1714 SOUTH 4TH STREET TAPS
AutoCAD SHX Text
SOUTH 4TH STREET
AutoCAD SHX Text
ENID, OKLAHOMA
AutoCAD SHX Text W-2613C
AutoCAD SHX Text Murali Katta, P.E., Director of Engineering
AutoCAD SHX Text Tam Nguyen, Project Engineer
AutoCAD SHX Text Jason Unruh, P.E., City Engineer
| Sheets and Views |
| P&P SHEET 12 |
File details come from the government source that posted it. Updated .