VGLZ 222003 - Repair HVAC B128 Drawings.pdf
PDF 4 MB Posted
- Attached to
- Repair HVAC Bldg. 128 Selfridge ANGB
- Solicitation number
- W50S8522R0008
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pre-Proposal Site Visit Sign-In Sheet B128.pdf | ||
| Pre-Proposal Conference Minutes - Repair HVAC B128 W50S8522R0008.docx | DOCX document | |
| 127 SFS Vetted Form 2021.xlsx | XLSX spreadsheet | |
| SOW Repair HVAC B128 - VGLZ 222003.pdf | ||
| VGLZ222003 - Repair B128 HVAC - Brand Name Justification - DDC signed cde.pdf | ||
| 127 SFS Vetted Form 2021.xlsx | XLSX spreadsheet | |
| W50S8522R0008 - Bldg. 128 HVAC Repair.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5
A
B
C
D
A
B
C
D
SHEET OF
Engineer/Consultants
Sheet Title
REPAIR
HVAC
BLDG 128
DEMO PLAN
1 2
REVISIONS:
Project Number:
File:
Drawn By:
Designed By:
Checked By: T. Resh T. Resh H. Bauzon
VGLZ 222003
Mark Date Description
PROJECT
Scale: NTS Date: 17 FEB 2022
NOTES:
\\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\127 WG.jpg \\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\CE Color PATCH small.jpg
DEMO 30 TON
OUTDOOR
CONDENSER UNIT.
PREPARE LOCATION
FOR INSTALLATION
OF NEW 30 TON UNIT.
DEMO 2 TON
SPLIT UNIT WITH
INDOOR UNIT
DEMO EXISTING
COIL & LINE SET
INSIDE EXISTING
AIR HANDLER
DEMO EXISTING LEIBERT
INDOOR UNIT
KEEP DUCT FOR CONNECTION
TO NEW FURNACE
DEMO 5 TON
LEIBERT UNIT AND
LINE SETS TO
INDOOR UNIT
DEMO 30 TON DX
UNIT REFRIGERANT
LINES
AutoCAD SHX Text 127th WING/CIVIL ENGINEER
AutoCAD SHX Text
SELFRIDGE AIR
AutoCAD SHX Text
NATIONAL GUARD
AutoCAD SHX Text
BASE, MICHIGAN
AutoCAD SHX Text
1. THE PLAN AND UNDERGROUND THE PLAN AND UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE GOVERNMENT MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE GOVERNMENT FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION.
AutoCAD SHX Text NOTE: FOR INFORMATION PURPOSES ONLY. NOT FOR DESIGN OR CONSTRUCTION. FIELD VERIFY DIMENSIONS PRIOR TO DESIGN AND PRIOR TO CONSTRUCTION.
AutoCAD SHX Text GENERAL NOTES: 1. ALL R22 WILL BE CAPTURED PER SELFRIDGE BASE ENVIRONMENTAL STANDARDS. 2. ALL REFRIGERANT WILL BE HANDLED PER SELFRIDGE BASE ENVIRONMENTAL STANDARDS. 3. ALL SOLID WASTE WILL BE HANDLED PER SELFRIDGE BASE ENVIRONMENTAL STANDARDS.
A
B
C
D
A
B
C
D
SHEET OF
Engineer/Consultants
Sheet Title
REPAIR
HVAC
BLDG 128
INSTALLATION
PLAN
2 2
REVISIONS:
Project Number:
File:
Drawn By:
Designed By:
Checked By: T. Resh T. Resh H. Bauzon
VGLZ 222003
Mark Date Description
PROJECT
Scale: NTS Date: 17 FEB 2022
NOTES:
\\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\127 WG.jpg \\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\CE Color PATCH small.jpg
INSTALL NEW
30 TON DX
WITH LINE SETS
TO NEW
INDOOR COIL.
INSTALL
NEW 2 TON
SPLIT UNIT
INSTALL NEW
COIL & LINE SET
SIZED PROPERLY
FROM 30 TON UNIT
INSTALL NEW 5-TON - 2200 CFM
AIR HANDLER UNIT WITH NEW
COIL FROM OUTSIDE 5-TON UNIT. INSTALL NEW
5-TON
OUTDOOR CONDENSER
AutoCAD SHX Text 127th WING/CIVIL ENGINEER
AutoCAD SHX Text
SELFRIDGE AIR
AutoCAD SHX Text
NATIONAL GUARD
AutoCAD SHX Text
BASE, MICHIGAN
AutoCAD SHX Text
1. THE PLAN AND UNDERGROUND THE PLAN AND UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE GOVERNMENT MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE GOVERNMENT FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION.
AutoCAD SHX Text NOTE: FOR INFORMATION PURPOSES ONLY. NOT FOR DESIGN OR CONSTRUCTION. FIELD VERIFY DIMENSIONS PRIOR TO DESIGN AND PRIOR TO CONSTRUCTION.
AutoCAD SHX Text GENERAL NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR ALL WORK REQUIRED TO MAKE THESE SYSTEMS MEET THE FULL FUNCTIONAL DESIGN INTENT. 2. CONTRACTOR WILL PERFORM ALL REQUIRED TASK TO INSTALL EQUIPMENT PER THE MANUFACTURER'S REQUIREMENTS.
| Sheets and Views |
| Repair HVAC 128-DEMO PLAN |
| Repair HVAC 128-INSTALL PLAN |