VGLZ 222003 - Repair HVAC B128 Drawings.pdf

PDF 4 MB Posted

Attached to
Repair HVAC Bldg. 128 Selfridge ANGB
Solicitation number
W50S8522R0008
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5

A

B

C

D

A

B

C

D

SHEET OF

Engineer/Consultants

Sheet Title

REPAIR

HVAC

BLDG 128

DEMO PLAN

1 2

REVISIONS:

Project Number:

File:

Drawn By:

Designed By:

Checked By: T. Resh T. Resh H. Bauzon

VGLZ 222003

Mark Date Description

PROJECT

Scale: NTS Date: 17 FEB 2022

NOTES:

\\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\127 WG.jpg \\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\CE Color PATCH small.jpg

DEMO 30 TON

OUTDOOR

CONDENSER UNIT.

PREPARE LOCATION

FOR INSTALLATION

OF NEW 30 TON UNIT.

DEMO 2 TON

SPLIT UNIT WITH

INDOOR UNIT

DEMO EXISTING

COIL & LINE SET

INSIDE EXISTING

AIR HANDLER

DEMO EXISTING LEIBERT

INDOOR UNIT

KEEP DUCT FOR CONNECTION

TO NEW FURNACE

DEMO 5 TON

LEIBERT UNIT AND

LINE SETS TO

INDOOR UNIT

DEMO 30 TON DX

UNIT REFRIGERANT

LINES

AutoCAD SHX Text 127th WING/CIVIL ENGINEER

AutoCAD SHX Text

SELFRIDGE AIR

AutoCAD SHX Text

NATIONAL GUARD

AutoCAD SHX Text

BASE, MICHIGAN

AutoCAD SHX Text

1. THE PLAN AND UNDERGROUND THE PLAN AND UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE GOVERNMENT MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE GOVERNMENT FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION.

AutoCAD SHX Text NOTE: FOR INFORMATION PURPOSES ONLY. NOT FOR DESIGN OR CONSTRUCTION. FIELD VERIFY DIMENSIONS PRIOR TO DESIGN AND PRIOR TO CONSTRUCTION.

AutoCAD SHX Text GENERAL NOTES: 1. ALL R22 WILL BE CAPTURED PER SELFRIDGE BASE ENVIRONMENTAL STANDARDS. 2. ALL REFRIGERANT WILL BE HANDLED PER SELFRIDGE BASE ENVIRONMENTAL STANDARDS. 3. ALL SOLID WASTE WILL BE HANDLED PER SELFRIDGE BASE ENVIRONMENTAL STANDARDS.

A

B

C

D

A

B

C

D

SHEET OF

Engineer/Consultants

Sheet Title

REPAIR

HVAC

BLDG 128

INSTALLATION

PLAN

2 2

REVISIONS:

Project Number:

File:

Drawn By:

Designed By:

Checked By: T. Resh T. Resh H. Bauzon

VGLZ 222003

Mark Date Description

PROJECT

Scale: NTS Date: 17 FEB 2022

NOTES:

\\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\127 WG.jpg \\127WG-FS-01\127WG_Shared\127WG_Shared\127 Mission_Support_Group\127th Civil Engineering Sq\CES_CECE Engineers\AutoCAD Users\CE Shared AutoCAD Settings\Templates\Template Graphics\CE Color PATCH small.jpg

INSTALL NEW

30 TON DX

WITH LINE SETS

TO NEW

INDOOR COIL.

INSTALL

NEW 2 TON

SPLIT UNIT

INSTALL NEW

COIL & LINE SET

SIZED PROPERLY

FROM 30 TON UNIT

INSTALL NEW 5-TON - 2200 CFM

AIR HANDLER UNIT WITH NEW

COIL FROM OUTSIDE 5-TON UNIT. INSTALL NEW

5-TON

OUTDOOR CONDENSER

AutoCAD SHX Text 127th WING/CIVIL ENGINEER

AutoCAD SHX Text

SELFRIDGE AIR

AutoCAD SHX Text

NATIONAL GUARD

AutoCAD SHX Text

BASE, MICHIGAN

AutoCAD SHX Text

1. THE PLAN AND UNDERGROUND THE PLAN AND UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE GOVERNMENT MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE GOVERNMENT FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION.

AutoCAD SHX Text NOTE: FOR INFORMATION PURPOSES ONLY. NOT FOR DESIGN OR CONSTRUCTION. FIELD VERIFY DIMENSIONS PRIOR TO DESIGN AND PRIOR TO CONSTRUCTION.

AutoCAD SHX Text GENERAL NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR ALL WORK REQUIRED TO MAKE THESE SYSTEMS MEET THE FULL FUNCTIONAL DESIGN INTENT. 2. CONTRACTOR WILL PERFORM ALL REQUIRED TASK TO INSTALL EQUIPMENT PER THE MANUFACTURER'S REQUIREMENTS.

Sheets and Views
Repair HVAC 128-DEMO PLAN
Repair HVAC 128-INSTALL PLAN

File details come from the government source that posted it. Updated .