DRWG_42605_dc15-15_DAL_1376_ChambersV1.pdf
PDF 8 MB Posted
- Solicitation number
- USDC_Courtroom_1376
About this file
Drawings
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISSUE DATE -
GSA ORDER NO. -
G
SA
P R
O
JE
C T
N O
ARCHITECT OF RECORD
VAI Architects Incorporated 16000 North Dallas Parkway, Suite 200 Dallas, Texas 75248
972.934.8888 t 972.458.2323 f
MEP ENGINEER
JJA Mechanical & Electrical Engineering Consultants 8150 North Central Eexpressway m-2100 Campbell Centre Dallas, Texas 75206
214.739.8880 t 972.458.1777 f
GSA CONTRACT NO. -
architects vai
G S-
P-
-1 6-
U A
-7
GS-07P-12-HH-D-0050
GS-P-07-16-UA-7005
DESIGN TEAM
1376 CHAMBERS REMODEL
06/06/2017
C H
A M
B
ER
S R
EM
O
D
EL
100% FINAL SUBMITTAL
1100 Commerce Street, Dallas, Tx. 75242
SH
EE
T N
U M
BE
R
SHEET NAME 15
C O
N C
EP
T
D
ES
IG
N
S U
BM
IT
TA
L
- 0 4/
/2
D
ES
IG
N
D
EV
EL
O
PM
EN
T
SU
BM
IT
TA
L
- 0 6/
/2
M
ID
PO
IN
T
SU
BM
IT
TA
L
- 0 9/
/2
P R
E-
FI
N
AL
S U
BM
IT
TA
L
- 0 3/
/2
0%
F
IN
AL
S
U
BM
IT
TA
L
- 0
6/
/2
GENERAL
COV COVER SHEET X X X X X
GI-101 ABBREVIATIONS, GRAPHIC SYMBOLS, AND NOTES X X X X X
GI-102 LIFE SAFETY PLAN AND CODE SUMMARY X X X X X
ARCHITECTURE
AD-101 13TH LEVEL DEMOLITION PLAN X X X X X
AD-201 13TH LEVEL RCP DEMO PLAN X X X X
AE-101 13TH LEVEL ENLARGED FLOOR PLAN X X X X
AE-201 13TH LEVEL FLOOR REFLECTED CEILING PLAN X X X X
AE-411 TOILET LAYOUTS & ACCESSORIES X X X X
AE-601 PARTITION TYPES & FRAMING DETAILS X X X
AE-611 DOOR SCHEDULE, NOTES AND DETAILS X X X X
AE-631 ROOM FINISH SCHEDULE X X
AE-721 INTERIOR ELEVATIONS & MILLWORK DETAILS X X
MECHANICAL
M-001 HVAC LEGEND AND NOTES X X X X
M-101 FLOOR PLAN - HVAC DEMO X X X X
M-201 FLOOR PLAN - HVAC X X X X
M-301 DETAILS / SCHEDULES - HVAC X X X X
ELECTRICAL
E-001 ELECTRICAL LEGEND, SCHEDULES AND NOTES X X X X
E-101 FLOOR PLAN - ELECTRICAL DEMO X X X X
E-201 FLOOR PLAN - LIGHTING X X X X
E-202 FLOOR PLAN - POWER X X X X
E-301 DETAILS, SCHEDULES - ELECTRICAL X X X
PLUMBING
P-001 PLUMBING LEGEND AND NOTES X X X
P-101 FLOOR PLAN - PLUMBING DEMO X X X X
P-201 FLOOR PLAN - PLUMBING X X X X
P-301 DETAIL / SCHEDULES - PLUMBING X X X
SHEET INDEX
V A
I P
R O
JE
C
T N
O . 1
.0
06/06/2017
N
SCALE:1View Name 1/8" = 1'-0"
1i
A101
SIM
1i
A
FRAME/WINDOW/LOUVER TYPE
PLAN, ELEVATION, SECTION OR DETAIL
REVISION NUMBER
COLOR/FINISH MARK
LEVEL MARK
ROOM NAME AND NUMBER
DOOR NUMBER
COLUMN REFERENCE GRID (LETTER,NUMBER)
BUILDING ELEVATION
DETAIL CALL OUT
BUILDING SECTION
NORTH ARROW
INTERIOR ELEVATION
WALL TYPE (NO SOUND ATTENUATION)
WALL TYPE (SOUND ATTENUATION)
Name
X' - X"
DIMENSION IN FEET AND INCHES
GRAPHIC SYMBOLS
CASEWORK ELEVATION
WALL SECTION
1i
/A101 1
A101
SIM
A101
SIM
A101
Name Elevation
EARTH
POROUS FILL (STONE OR GRAVEL, ETC.)
ROCK
CONCRETE
BRICK
CONCRETE MASONRY UNITS
GLASS BLOCKS
CUT STONE
ALUMINUM
STEEL OR OTHER METAL
CEMENT PLASTER
GYPSUM BOARD/SHEATHING
RIGID INSULATION
BATT INSULATION
WOOD FRAMING/BLOCKING (CONTINUOUS)
WOOD BLOCKING OR SHIM
FINISH WOOD
PLYWOOD SHEATHING
SAND, CEMENT, MORTAR, OR GROUT
PARTICLEBOARD
MATERIAL LEGEND
AB ANCHOR BOLT
ACC ACCESSIBLE
A/C AIR CONDITIONING
ACDR ACOUSTICAL DOOR
ACS PNL ACCESS PANEL
ACST ACOUSTICAL
ADA, ADAAG AMERICANS WITH DISABILITIES
ACT ACCESSIBILITY GUIDELINES
ADJ ADJUSTABLE
ADMIN ADMINISTRATION, ADMINISTRATIVE
AF DR ACCORDION FOLDING DOOR
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AMP AMPERES
ANOD ANODIZED
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE, APPROXIMATELY
AR AS REQUIRED
ARCH ARCHITECT, ARCHITECTURAL
ASC ABOVE SUSPENDED CEILING
ASH ASPHALT SHINGLES
ASSY ASSEMBLY
AUX AUXILIARY
AWI ARCHITECTURAL WOODWORK INSTITUTE
AWP ACOUSTICAL WALL PANEL
B
BALC BALCONY
BC BACK OF CURB
BD BOARD
BK BRICK
BLDG BUILDING
BLKG BLOCKING
BLKHD BULKHEAD
BM BEAM
BO BOTTOM OF
BOD BOTTOM OF DECK
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRZ BRONZE
BS BOTH SIDES
BTU BRITISH THERMAL UNIT
BU BUILT-UP
BUR BUILT-UP ROOFING
C CHANNEL, CELSIUS
CAB CABINET
CBB CEMENTITIOUS BACKER BOARD
CD CONTRACT DOCUMENTS
CDM CAVITY DRAINAGE MATERIAL
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CH COAT HOOK
CH BD CHALK BOARD
CI CAST IRON
CJ CONTROL JOINT
CL CENTER LINE
CLF CHAIN LINK FENCE
CLG CEILING
CLO CLOSET
CLR CLEAR, COLOR, COOLER
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION, CONNECT
CONSTR CONSTRUCTION
CONT CONTINUOUS, CONTINUE
COORD COORDINATE, COORDINATION
CORR CORRIDOR
CPT CARPET
CRC COLD ROLLED CHANNEL
CS CAST STONE
CT CERAMIC TILE
CU CUBIC
CURT TK CURTAIN TRACK
CUST CUSTODIAN
CWFP CEMENTITIOUS WOOD FIBER PLANK
D DEPTH, DEEP
DAMPF DAMPPROOFING
DBL DOUBLE
DEG DEGREE
DEF DEFORMED, DEFINITION
DEMO DEMOLITION, DEMOLISH
DET DETAIL(S)
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGRAM
DIM DIMENSION
DISP DISPENSER
DIST DISTANCE
DIV DIVISION, DIVIDE
DL DEAD LOAD
DN DOWN
DOC DOCUMENT(S)
DR DOOR
DS DOWNSPOUT
DWG DRAWING(S)
DWR DRAWER
E EAST
EA EACH
EF EMBEDDED FLASHING
EGSB EXTERIOR GYPSUM SHEATHING BOARD
EIFS EXTERIOR INSUL AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
EP EPOXY
EQ EQUAL
EQF EPOXY QUARTZ FLOORING
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ESS EMERGENCY SHOWER STATION
ETC ET CETERA
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION, EXPOSED
EXT EXTERIOR
EXTN EXTENSION
A
B
C
D
E
F FAHRENHEIT
FA FIRE ALARM
FAS FASCIA
FD FLOOR DRAIN
FDTN FOUNDATION
EF FIRE EXTINGUISHER
EFC FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FF EL FINISH FLOOR ELEVATION
FHC FIRE HOSE CABINET
FIG FIGURE
FIN FINISH
FIXT FIXTURE
FLASH FLASHING
FLDG PTN FOLDING PARTITION
FLR FLOOR
FLR PNL FILLER PANEL
FLT GL FLOAT GLASS
FO FACE OF ..., FINISH OPENING
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD, FACE OF STEEL
FR FIRE RATED, FIRE RATING
FRP FIBER REINFORCED PLASTIC
FRPLYWD FIRE RETARDANT TREATED PLYWOOD
FRWD FIRE RETARDANT TREATED WOOD
FRZ FREEZER
FT FEET
FTG FOOTING
FT SCR FOOT SCRAPER
FURG FURRING
FW FIRE WALL
Fy YIELD STRESS
G GROUND
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GEN GENERAL
GL GLASS
GLZ GLAZING, GLAZED
GR GRADE
GSU GLAZED STRUCTURAL UNIT
GYP BD GYPSUM BOARD
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HC FV HOLLOW CORE FINISH VENEER
HD HEAD, HEADED, HEAVY DUTY
HD GALV HOT-DIPPED GALVANIZED
HDR HEADER
HDW HARDWARE
HDWD HARD WOOD
HIWC HIGH IMPACT WALL COVERING
HJS HEAD, JAMB, AND SILL (AT OPENINGS)
HLB HORIZONTAL LOUVER BLINDS
HM HOLLOW METAL
HORIZ HORIZONTAL
HPC HIGH PERFORMANCE COATING
HR, HRS HOUR, HOURS
HSTL HOLLOW CORE STEEL (DOOR)
HT HEIGHT
IAW IN ACCORDANCE WITH
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER, INSIDE DIMENSION
IN INCH, INCHES
INC INCREASE
INCAND INCANDESCENT
INCL INCLUDING
INFO INFORMATION
INSUL INSULATION, INSULATING
INT INTERIOR
IPC INTERNATIONAL PLUMBING CODE
IRWC IMPACT-RESISTANT WALL COVERING
ISTL INSULATED CORE STEEL (DOOR)
JAN JANITOR
JST JOIST
JT JOINT
JTF JOINT FILLER
K KINDERGARTEN
KD KNOCK DOWN
KIT KITCHEN
KOP KNOCK OUT PANEL
KS KNEE SPACE
L ANGLE, ANGLE SHAPE
LAM LAMINATE
LAV LAVATORY
LB POUND, LOAD BEARING
LF LINEAR FOOT
LG LENGTH
LIB LIBRARY
LKR LOCKER
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMC LINEAR METAL CEILING
LOC LOCATE, LOCATION
LONG LONGITUDINAL
LSD LIQUID SOAP DISPENSER
LT LIGHT
LVR LOUVER
F
G
H
I
J
K
L
M MORTAR
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MBH MOP/BROOM HOLDER
MCJ MASONRY CONTROL JOINT (CMU)
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEJ MASONRY EXPANSION JOINT (BRICK MASONRY)
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL, PLUMBING
MEZZ MEZZANINE
MFCS MINERAL FIBER CEMENT SHINGLES
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGR MANAGER
MH MANHOLE
MICS MULTICOLORED INTERIOR COATING SYSTEM
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MKRBD MARKERBOARD
MLDG MOLDING
mm MILLIMETER
MO MASONRY OPENING, MOTOR OPERATED
MOD BIT MODIFIED BITUMEN (ROOFING)
MPH MILES PER HOUR
MOD MODIFY, MODEL
MSB MOP SERVICE BASIN
MTD MOUNTED
MTG MOUNTING
MTL METAL
MTLR METAL ROOFING
MTLWP METAL WALL PANEL
MULL MULLION
MWP MEMBRANE WATER PROOFING
N NORTH
NA NOT APPLICABLE
NEG NEGATIVE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NLB NONLOAD BEARING
NO, NOS NUMBER, NUMBERS
NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION
NTS NOT TO SCALE
OC ON CENTER
OCC OCCUPANCY
OD OUTSIDE DIAMETER/DIMENSION
OF/CI OWNER FURNISHED/ CONTRACTOR INSTALLED
OFF OFFICE
OH OVERHEAD
OH DR OVERHEAD (COILING) DOOR
OH GRL OVERHEAD (COILING) GRILLE
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
OSB ORIENTED STRAND BOARD
PA PUBLIC ADDRESS
PAR PARALLEL, PARAPET
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCP PORTLAND CEMENT PLASTER
PCT PERCENT
PEN PENETRATION
PERF PERFORATED
PERP PERPENDICULAR
PH PHASE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTIC, PLASTER
PLBG PLUMBING
PLCP PREMANUFACTURED LAMINATE CLAD PANELWORK
PLYWD PLYWOOD
PM PREFINISHED METAL
PNL PANEL
PORC PORCELAIN
POS POSITIVE
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRE-K PREKINDERGARTEN
PNT PAINT, PAINTED
PT PESERVATIVE TREATED, PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTGR PAINT GRADE
PTN PARTITION
PTPLYWD PRESERVATIVE TREATED PLYWOOD
PTWD PRESERVATIVE TREATED WOOD
PVC POLYVINYL CHLORIDE
PVG PAVING
PVR PAVER (TILE)
QA QUALITY ASSURANCE
QT QUARRY TILE
R RADIUS
RAF RESILIENT ATHLETIC FLOORING
RB RUBBER BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REINF REINFORCED, REINFORCEMENT
REF REFER, REFERENCE, REFRIGERATOR
REM REMOVABLE
REP REPRESENTATIVE
REQD REQUIRED
REQT, REQTS REQUIREMENT, REQUIREMENTS
REV REVISION(S)
RF RUBBER FLOORING
RH ROOF HATCH
RM ROOM
RO ROUGH OPENING
RTG RATING
RTU ROOF TOP UNIT
RV ROOF VENT
RWAF RESILIENT WOOD ATHLETIC FLOORING
M
N
O
P
Q
R
S SOUTH
SACMU SOUND ABSORBING CONCRETE MASONRY UNIT
SB SPLASH BLOCK
SC SOLID CORE
SCDR SIDE COILING DOOR
SCGRL SIDE COILING GRILLE
SCHED SCHEDULE
SCJ SAWN CONTROL JOINT
SCON SEALED CONCRETE
SCPL SOLID CORE PLASTIC LAMINATE (DOOR)
SCR SHOWER CURTAIN ROD
SCURT STAGE CURTAIN
SCT STRUCTURAL CLAY TILE
SCWV SOLID CORE WOOD VENEER (DOOR)
SD SMOKE DETECTOR
SECT SECTION
SEP SEPARATE, SEPARATION
SF SQUARE FEET
SFRM SPRAYED FIRE RESISTIVE MATERIALS
SGD SLIDING GLASS DOOR
SGL SINGLE
SHR SHOWER
SHT SHEET
SHTHG SHEATHING
SIM SIMILAR
SL CONC SEALED CONCRETE
SLD SEALED
SLNT SEALANT
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOC
SND SANITARY NAPKIN DISPENSER
SNDU SANITARY NAPKIN DISPOSAL UNIT
SOSG SELF OPENING SAFETY GRILLE
SOHD SECTIONAL OVERHEAD DOOR
SPA SPACES
SQ SQUARE
SS SERVICE SINK, STANDING SEAM (ROOF)
SST STAINLESS STEEL
STAG STAGGERED
STC SOUND TRANSMISSION CLASS
STD STANDARD
STF STAINED FINISH
STFT STOREFRONT
STL STEEL
STOR STORAGE
STRUCT STRUCTURE, STRUCTURAL
SUP SUPPLEMENTARY
SUSP SUSPENDED
SV SHEET VINYL
SWPPP STORM WATER POLLUTION PREVENTION PLAN
SYMM SYMMETRICAL
SYS SYSTEM
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TAB TABLE
TAS TEXAS ACCESSIBILITY STANDARDS
TC TEACHER CABINET, TALL CABINET
TCSF TRANSPARENT COATED STAINED FINISH
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZO
THK THICK, THICKNESS
THRU THROUGH
TKBD TACKBOARD
TKST TACK STRIP
TKSURF TACK SURFACE
TLT TOILET
TO TOP OF
TOC TOP OF CURB, TOP OF CONCRETE
TOD TOP OF DRAIN
TOM TOP OF MASONRY
TOPT TOP OF PARAPET
TOS TOP OF STEEL, TOP OF STUD
TOSB TOP OF SLAB
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPTN TOILET PARTITION
TWC TEXTILE WALL COVERING
TWP TRANSLUCENT WALL PANEL
TYP TYPICAL
UBC UNIFORM BUILDING CODE
UL UNDERWRITER'S LABORATORY
UON UNLESS OTHERWISE NOTED
UNO UNLESS NOTED OTHERWISE
UPC UNIFORM PLUMBING CODE
UR URINAL
UR SCRN URINAL SCREEN
UTIL UTILITY
V VOLTS
VAR VARIES
VCT VINYL COMPOSITION TILE
VEND VENDING
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WEST, WIDTH, WIDE, OR WATTS
W/ WITH
WB WIND BRACE
WBBP WIND BRACE BASEPLATE
WC WATER CLOSET, WALL COVERING
WD WOOD
WF WASH FOUNTAIN
WH WATER HEATER
WDW WINDOW
WI WROUGHT IRON
WLD WELDED
W/O WITHOUT
WOM WOMEN
WP WEATHERPROOF, WATERPROOFING
WP WALL PAD
WR WASTE RECEPTICLE
WS WAINSCOT
WTR WATER RESISTANT
WT WEIGHT
WWF WELDED WIRE FABRIC
S
T
U
V
W
UNLESS OTHERWISE LISTED BELOW, TERMS AND ABBREVIATIONS USED IN THIS DOCS ARE IN COMPLIANCE WITH "TERMS AND ABBREVIATIONS MODULE" OF UNIFORM DRAWING SYSTEM (UDS), THE LATEST EDITION
ABBREVIATIONS
1. ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL/MUNICIPAL CODES, AND ORDINANCES APPLICABLE TO THE CONSTRUCTION. CONTRACTOR SHALL PROVIDE AND PAY FOR ALL PERMITS AND INSPECTIONS, IMPACT FEES, TAP FEES AND BUILDING PERMIT FEES NECESSARY FOR THE EXECUTION AND COMPLETION OF ALL WORK.
2. CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIAL, EQUIPMENT, LABOR, AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS REQUIRED BY THE PLANS AND
SPECIFICATIONS.
3. ALL CONTRACTORS SHALL RECEIVE A COMPLETE SET OF CONSTRUCTION DOCUMENTS AND SPECIFICATIONS AND SHALL BE RESPONSIBLE FOR THEIR COMPLETE SCOPE OF WORK REGARDLESS OF WHERE IN THE DOCUMENT SET THE DESCRIPTION OF WORK APPEARS.
4. CONTRACTOR SHALL REPORT IN WRITING ANY DISCREPANCIES, OMISSIONS OR INCONSISTENCIES IN THE CONTRACT DOCUMENTS TO THE GSA REPRESENTATIVE / PROJECT MANAGER FOR VERIFICATION BEFORE STARTING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION UNTIL DISCREPANCIES ARE RESOLVED.
5. CONTRACTOR SHALL NOTIFY THE GSA REPRESENTATIVE / PROJECT MANAGER IMMEDIATELY IF CONFLICTS ARISE WITH ANY EXISTING SERVICE LINES. ARCHITECT WILL ISSUE SUPPLEMENTAL
INSTRUCTIONS.
6. CONTRACTOR SHALL DESIGNATE ALL ON-SITE STAGING AREAS, ENTRANCES AND PARKING PRIOR TO CONSTRUCTION.
7. ALL ARCHITECTURAL DIMENSIONS ARE TO FACE OF METAL STUD, FACE OF EXPOSED MASONRY/CONCRETE, OR CENTERLINE OF STRUCTURAL COLUMNS U.N.O.
MASONRY DIMENSIONS ON ARCHITECTURAL PLANS ARE NOMINAL.
8. ALL NOTES AND DETAILS MARKED TYPICAL APPLY TO SIMILAR CONDITIONS THROUGHOUT THE PROJECT WHETHER SPECIFICALLY NOTED OR NOT.
9. FRAMING, BRACING, BLOCKING, NAILERS AND SHIMS CONTAINED WITHIN THE WALL SYSTEM AND ALL MISCELLANEOUS CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED WOOD EXCEPT FOR NAILERS/ BLOCKING WITHIN THE ROOFING & COPING SYSTEMS, U.N.O. NAILERS/ BLOCKING WITHIN THE ROOFING & COPING SYSTEMS SHALL BE PRESSURE-TREATED AGAINST MOISTURE PENETRATION WITH A PRESERVATIVE THAT IS APPROVED BY THE ROOFING & COPING SYSTEMS MANUFACTURER.
10. SHOP DRAWINGS AND/OR FULLY DESCRIPTIVE CATALOG DATA SHALL BE SUBMITTED AND APPROVED PRIOR TO FABRICATION OR ORDERING OF ANY MATERIALS.
DATA SHALL INCLUDE DIMENSIONS, TECHNICAL INFORMATION, AND OTHER DATA NECESSARY TO EVALUATE THE PROPOSED MATERIALS.
11. DATUM ELEVATION OF 100'-0" FOR EACH BUILDING OR CANOPY SHALL BE FROM TOP OF BUILDING GROUND FLOOR SLAB OR HIGHEST PAVEMENT LEVEL BENEATH CANOPY.
REF. CIVIL DRAWINGS FOR ACTUAL ELEVATION(S) ABOVE SEA LEVEL.
GENERAL NOTES
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE
PROPERLY DESTROY OR RETURN DOCUMENTS WHEN NO LONGER NEEDED
architect client / owner project revision no:
issue date:
gsa order no.:
drawn by:
issue title:
sheet title:
sheet no:
issue date:
checked by:
architects vai seal / disclaimer project team
ARCHITECT OF RECORD
vai architect incorporated 16000 north dallas parkway, suite 200 dallas, texas 75248
972.934.8888 t 972.458.2323 f
MEP/FP ENGINEER
JJA, Inc.
8150 n. central expressway suite M-2100 dallas, texas 75206
214.739.8880 t
GS-P-07-16-UA-7005
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
6/ 7/
:1
0:
P M
GI-101
ABBREVIATIONS,
GRAPHIC
SYMBOLS,
AND NOTES
1376 CHAMBERS
REMODEL
DSGC
06/06/2017
100% FINAL
SUBMITTAL
C H
AM
BE
R S
R
EM
O D
EL
1100 Commerce Street, Dallas, Tx. 75242
BUILDING CODE SUMMARY
PROJECT:
CHAMBER REMODEL 1376
Tenant Improvement
ARCHITECT:
VAI Architects, Inc.
16000 North Dallas Parkway Suite 200 Dallas, Texas 75248 Project No. 13016.030
1.0 Applicable Codes:
Building: International Building Code - 2015 Mechanical: International Mechanical Code - 2015 Plumbing: International Plumbing Code - 2015 Electrical: International Electrical Code - 2015 Energy: International Energy Code - 2015 Accessibility : (ABAAS) Architectural Barriers Act Accessibility Standard - 2004 Life Safety: National Fire Protection Association (NFPA 101) - Current Ed.
2.0 Occupancy of Use Group Classification:
Principal Occupancy: B-Business IBC 305.1
3.0 Type of Construction: Existing High-Rise Building Type I-A IBC Table 503
4.0 Height And Area Limitations: No adjustment in building height
Business Group B: (13th floor) DC15-15 Judge's Chambers IBC Table 503
Actual Tenant Space Renovation: 4,726 sf
Area Increase: Unlimited for Type I-A construction IBC Table 503
Maximum Allowable Area Per Floor: Unlimited
6.0 Occupancy Separation Requirements:
Separation between Occupancy Business: 0HR NFPA 6.1.14.4.1(b) Separation from Exit Access Corridors: 0HR NFPA 7.1.3.1
7.0 Interior Finishes: Source: NFPA 39.3.3.2
Exit Enclosures Class B min. (26-75 flame spread; smoke development 0-450) Passageways:
Corridors: Class B min (26-75 flame spread; smoke development 0-450) Wall/Ceiling: Class C min (76-200 flame spread; smoke development 0-450)
8.0 Fire Protection Requirements:
Fire alarm system required/Provided: YES/YES Source: IBC 907.2.3
Portable fire extinguishers require 75 feet travel distance (150 feet apart).
9.0 Occupant Load / Detailed Exit Requirements: IBC Table 1004.1.1
Occupant Load Factor Calculations: NFPA 101 7.3.1.2
Assembly (A-3): Break Room 13E202 15 NSF/person @ 349sf = 24 people Break Room 13C206 15 NSF/person @ 320sf = 22 people Conference Room 13E203 15 NSF/person @ 292sf = 20 people
Business (B): 100GSF/person@3,765 = 38 people TOTAL = 104 people
Exit Width Requirements: .2 inches/person (min 36inches) NFPA 101 7.3.3.1 36" min. required / 200" provided
11.0 Plumbing Fixture Requirements:
Occupant Load (from 9.0 above, and subdivided as follows):
Divide occupant load in half to get male / female ratio. IBC Table 2902.1
2902.1.3 Occupant load for minimum plumbing facilities. In determining minimum plumbing facilities, the number of occupants for whom minimum plumbing facilities are provided shall be computed in accordance with Section 1004.
(Occupancy) Total males / females: 104 persons = 52 Males & 52 Females
Toilets: 1 per 25 up to 50; 1 for every 50 over 50 Lavatories: 1 per 40 up to 80; 1 for every 80 over 80 Drinking Fountains (DF): 1 per 100
Males:
Water Closets, required/provided : 2/16 (4 urinals)
Lavatories, required/provided: 2/8
Females:
Water Closets, required/provided: 2/11
Lavatories, required/provided: 2/8
General:
Drinking Fountains, required/provided: 2/6
Service Sink:
One required 1/3 (provided)
END OF REPORT
10.0 Other Exit Requirements (required/provided):
Minimum Exits(required/provided): 2/2 IBC Table 1019.1
Maximum Travel Distance: 200ft max./190ft. provided NFPA 101 39.2.6.3
Maximum Common Path of Travel: <100ft/100'-0" max. NFPA 101 39.2.5.3.1
Arrangement of Exits: 1/2 the distance of diagonal NFPA 101 7.5.1.4
Corridors:
Minimum Width: 72 inches IBC Sec 1017.2 Fire Resistance: 0 hour w/sprinkled facility IBC Table 1017.1
Max. Dead End Corridor: 20ft /0ft IBC Sec 1017.3
Stairs:
Minimum Width: 44 inches - PROVIDED IBC Sec 1009.1
Fire Resistance: 1 hr - PROVIDED IBC Sec 1020.1 Exception 8
Minimum Headroom: 80 inches - PROVIDED IBC Sec 1009.2
Risers / Treads: 7 inches max / 11 inches min. IBC Sec 1009.3
Landings: Minimum landing shall be equal to stair width. Doors opening into landing may not reduce width by more than 50%. IBC Sec 1009.4
Elevator Shafts:
Fire Resistance: 1 hour fire rated construction IBC Sec. 707.4
EXIT
EX
IT
M
AX
T R
AV
EL
: 1
'-0
EXIT
MAX TRAVEL: 190'-0"
EXIT
10.4"64"
EXIT A
320 52
10.4"36"
EXIT C
180 52
1 HR FIRE BARRIER
2 HR FIRE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED WALL
LIFE SAFETY PLAN LEGEND
SMOKE COMPARTMENT WALL
FIRE DEPARTMENT CONNECTION
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FDC
FEC
FE
EXIT SYMBOL
EXIT SIGN -
HATCH INDICATES EXIT
TEXT AND ARROW
INDICATES DIRECTION
TRAVEL DISTANCE FROM
THE MOST REMOTE POINT
TO THE CLOSEST EXIT
TRAVEL DISTANCE WITHIN A
SMOKE ZONE TO AN ADJACENT
SMOKE ZONE
XXX'-X"
XXX'-X"
NOT IN SCOPE
EXTENT OF WORK
33"36"
EXIT A
165 120
EGRESS WIDTH
CAPACITY
EGRESS WIDTH
CAPACITY
PROVIDED REQUIRED
architect client / owner project revision no:
issue date:
gsa order no.:
drawn by:
issue title:
sheet title:
sheet no:
issue date:
checked by:
architects vai seal / disclaimer project team
ARCHITECT OF RECORD
vai architect incorporated 16000 north dallas parkway, suite 200 dallas, texas 75248
972.934.8888 t 972.458.2323 f
MEP/FP ENGINEER
JJA, Inc.
8150 n. central expressway suite M-2100 dallas, texas 75206
214.739.8880 t
GS-P-07-16-UA-7005
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
6/ 7/
:1
0:
P M
GI-102
LIFE SAFETY
PLAN AND
CODE
SUMMARY
1376 CHAMBERS
REMODEL
DSGC
06/06/2017
100% FINAL
SUBMITTAL
C H
AM
BE
R S
R
EM
O D
EL
1100 Commerce Street, Dallas, Tx. 75242
12'0 24'4' N
SCALE: 3/32" = 1'-0"H1LIFE SAFETY PLAN
2 2
14 8 8 14 8 8 8
ROOM
13E23F
ROOM
13E16A
ROOM
13E16B
ROOM
13E23F
ROOM
13E16C
ROOM
13E16D
ROOM
13E21B
ROOM
13E21C
ROOM
13E23H
ROOM
13E23L
ROOM
13E23J
ROOM
13E23G
ROOM
13E23C
ROOM
13C37C
ROOM
13C37A
ROOM
13C37B
ROOM
13E226
6 6
ELEC. TELE.
1 1
13 1313
8 4 4 8
1. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS DURING THE COURSE OF
DEMOLITION AND NEW CONSTRUCTION, AND SHALL BRING TO THE ATTENTION OF
THE GSA ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTS. THE GSA WILL
PREPARE SUPPLEMENTAL DETAILS OR WILL MODIFY THE REQUIREMENTS TO
ACCOMMODATE THE CHANGE.
2. CONTRACTOR SHALL PROTECT EXISTING CONSTRUCTION AND FINISHES THAT ARE
NOT AFFECTED BY DEMOLITION, REPAIR OR REPLACE WORK INADVERTENTLY
DAMAGED BY DEMOLITION OPERATIONS AT NO ADDITIONAL COST TO OWNER.
3. REMOVE EXISTING INTERIOR PARTITIONS AND ALL ACCOMPANYING ELEMENTS
INCLUDING BUT NOT LIMITED TO DOORS AND FRAMES, CONDUIT AND ALL
ELECTRICAL ITEMS, PLUMBING, PIPING AND MECHANICAL ITEMS. NOTE: PROTECT AND
PRESERVE ALL EXISTING STRUCTURAL ELEMENTS TO REMAIN.
4. CONTRACTOR TO FIELD VERIFY WHERE ALL STRUCTURAL MEMBERS ARE - PRIOR
TO DEMOLITION - INCLUDING COLUMNS AND LOAD BEARING WALLS. NOTIFY GSA OF
FINDING PRIOR TO DEMOLITION.
5. REFER TO MEP DEMOLITION PLANS FOR ADDITIONAL INSTRUCTIONS: EXISTING MEP
ITEMS WHICH ARE TO REMAIN ARE TO BE PRESERVED AND PROTECTED THROUGHOUT
CONSTRUCTION.
6. ALL HAZARDOUS MATERIAL ABATEMENT BY OTHERS. NOTIFY GSA PROJECT
MANAGER / REPRESENTATIVE OF SUSPECT ACM.
7. CONTAINERS AND WASTE HANDLING WILL BE STRICTLY PER GSA'S DIRECTIVES
(LOCATIONS, ROUTES, ETC.)
8. CONTRACTOR TO PRESERVE AND PROTECT ALL FINISHES OUTSIDE THE SUITE -
INCLUDING ELEVATOR CAB, CORRIDOR FLOORS AND WALLS, ETC.
9. REMOVE ALL EXISTING CEILINGS AND CEILING GRIDS, LIGHT FIXTURES, CEILING
DEVICES, HVAC, ETC. EXCEPT AS NOTED ON PLAN.
GENERAL DEMOLITION NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION
TO BE REMOVED
AREA NOT IN SCOPE
EXTENT OF WORK
DEMO FLOOR PLAN LEGEND
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE
PROPERLY DESTROY OR RETURN DOCUMENTS WHEN NO LONGER NEEDED
DEMOLITION KEY NOTES
EXISTING DOOR ASSEMBLY TO BE REMOVED.
REMOVE EXISTING CARPET, VCT OR CERAMIC TILE. CLEAN/PREP SURFACE TO
RECEIVE NEW FLOORING AS SCHEDULED. PATCH/FLOAT SLAB AS REQUIRED FOR
SMOOTH LEVEL SURFACE.
REMOVE SINKS AND CABINETRY/MILLWORK. REMOVE EXISTING SANITARY WASTE,
VENT, AND DOMESTIC CW/HW PIPING BACK TO STACKS/MAINS. CAP AND SEAL.
REMOVE EXISTING BLINDS AT EXTERIOR WINDOWS. PREP WINDOWS TO RECEIVE
NEW BLINDS AS SPECIFIED.
EXISTING WALL ASSEMBLY TO BE REMOVED.
IDENTIFY EXISTING CEILING/WALL MOUNTED FIRE ALARM DEVICES AND/OR
SECURITY DEVICES REMOVE AND REPLACE WITH NEW DEVICES.
CONTRACTOR SHALL VERIFY EXISTING WALL CONSTRUCTION AND REMOVE
INTERIOR (TENANT SIDE) OF WALL. EXTEND FRAMING TO DECK AS REQUIRED.
REFERENCE PARTITION TYPES FOR ADDITIONAL INFORMATION.
REMOVE EXISTING TOILET AND ALL ASSOCIATED EQUIPMENT.9
4 CONTRACTOR SHALL REMOVE AND RESURFACE ALL DRYWALL / PLASTER AT
SOFFITS/FURR DOWNS ABOVE WINDOWS.
10 BOOKCASES AND ASSOCIATED WOOD PANELING TO BE REMOVED.
11 CONTRACTOR TO REMOVE INTERIOR (TENANT SIDE) PANELING OR GYP. BOARD
FROM WALL ASSEMBLY. RETAIN FRAMING FOR USE IN FINISH WORK.
12 EXISTING FIRE EXTINGUISHER CABINET TO BE REMOVED AND STORED IN A SECURE
LOCATION FOR REINSTALLATION. CONTRACTOR TO REMOVE GYP. BD., RETAIN
FRAMING AND MODIFY AS REQUIRED TO MEET NEW DESIGN LAYOUT.
EXISTING DOOR ASSEMBLY TO REMAIN.13
REMOVE EXISTING WOOD SHUTTERS AT EXTERIOR WINDOWS AND RETURN TO
USDC. PREP WINDOWS TO RECEIVE NEW WINDOW TREATMENTS AS SPECIFIED.
architect client / owner project revision no:
issue date:
gsa order no.:
drawn by:
issue title:
sheet title:
sheet no:
issue date:
checked by:
architects vai seal / disclaimer project team
ARCHITECT OF RECORD
vai architect incorporated 16000 north dallas parkway, suite 200 dallas, texas 75248
972.934.8888 t 972.458.2323 f
MEP/FP ENGINEER
JJA, Inc.
8150 n. central expressway suite M-2100 dallas, texas 75206
214.739.8880 t
GS-P-07-16-UA-7005
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
6/ 7/
:1
0:
P M
AD-101
13TH LEVEL
DEMOLITION
PLAN
1376 CHAMBERS
REMODEL
DSGC
06/06/2017
100% FINAL
SUBMITTAL
C H
AM
BE
R S
R
EM
O D
EL
1100 Commerce Street, Dallas, Tx. 75242
SCALE: 1/4" = 1'-0"H2THIRTEENTH FLOOR DEMOLITION PLAN
0 2' 4' 8'
F
F
FF
F
SD
F
F
F
F
F
F
F
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE
PROPERLY DESTROY OR RETURN DOCUMENTS WHEN NO LONGER NEEDED
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION
TO BE REMOVED
AREA NOT IN SCOPE
EXTENT OF WORK
RCP DEMO LEGEND
CONTRACTOR SHALL REMOVE EXISTING CEILING GRID, TILE AND ALL LIGHT
FIXTURES TYPICAL IN ALL SPACES U.N.O. COORDINATE WITH GSA PROJECT
MANAGER FOR STORAGE OF EXISTING LIGHT FIXTURES.
CONTRACTOR SHALL REFERENCE DRAWINGS FOR COORDINATION OF ALL
EXISTING CEILING MOUNTED DEVICES, INCLUDING FIRE ALARM
ANNUNCIATORS, CEILING MOUNTED SPEAKERS AND ADDITIONAL DEVICES.
CONTRACTOR SHALL IDENTIFY ANY DEVICES NOT INDICATED ON DRAWINGS
AND BRING TO THE ATTENTION OF THE GSA PROJECT MANAGER. ALL CEILING
MOUNTED DEVICES SHALL BE STORED AND REINSTALLED.
CONTRACTOR SHALL COORDINATE THE MODIFICATION OF THE EXISTING
SPRINKLER LAYOUT WITH THE PROVIDED PERFORMANCE LEVEL
SPECIFICATIONS.
CONTRACTOR TO DISCONNECT HVAC SYSTEM DUCT WORK FROM EXISTING
LIGHT FIXTURES. REFERENCE MECHANICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
ALL EXISTING SUPPLY AND RETURN DIFFUSERS TO BE DISCONNECTED FROM
HVAC SYSTEM DUCT WORK AND REMOVED FROM CEILING.
CEILING FANS TO BE REMOVED AND DISPOSED OF. COORDINATE DISPOSAL
W/ GSA PROJECT MANAGER/REPRESENTATIVE.
DEMOLITION KEYED NOTES
BR
FEC
S
S
S
S
S
S S
S
S
S
S S
S
EXISTING CEILING ASSEMBLY, GRID,
LIGHTS, DIFFUSERS/REGISTERS AND
CEILING MOUNTED DEVICES TO BE
REMOVED. COORDINATE STORAGE
WITH GSA PROJECT MANAGER
2S
3 3
3 3
4 4
3 2
4 1 architect client / owner project revision no:
issue date:
gsa order no.:
drawn by:
issue title:
sheet title:
sheet no:
issue date:
checked by:
architects vai seal / disclaimer project team
ARCHITECT OF RECORD
vai architect incorporated 16000 north dallas parkway, suite 200 dallas, texas 75248
972.934.8888 t 972.458.2323 f
MEP/FP ENGINEER
JJA, Inc.
8150 n. central expressway suite M-2100 dallas, texas 75206
214.739.8880 t
GS-P-07-16-UA-7005
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
6/ 7/
:1
0:
P M
AD-201
13TH LEVEL
RCP DEMO
PLAN
1376 CHAMBERS
REMODEL
DSGC
06/06/2017
100% FINAL
SUBMITTAL
C H
AM
BE
R S
R
EM
O D
EL
1100 Commerce Street, Dallas, Tx. 75242
0 2' 4' 8'
N
SCALE: 1/4" = 1'-0"H213TH FLOOR RCP DEMOLITION PLAN
G
FI
G
FI
GFIGFIGFI
G
FI
G
FI
G
FI
GFI GFI
R
88 SF
JUDGE NO.1
REST ROOM
13E208
88 SF
JUDGE NO.2
REST ROOM
13C205
146 SF
LAW CLERK
NO.2
13C203
73 SF
PRINT ROOM
13E206
294 SF
RECEPTION
13C201
274 SF
CORRIDOR
13C207
292 SF
CONFERENCE
ROOM
13E203
152 SF
LAW CLERK
NO.1
13C202
180 SF
CORRIDOR
13C200
349 SF
BREAK ROOM
13E202
151 SF
LAW CLERK
NO.1
13E204
150 SF
LAW CLERK
NO.2
13E205
320 SF
BREAK ROOM
13C206
606 SF
JUDGE'S
CHAMBERS #2
13C204
617 SF
JUDGE'S
CHAMBERS #1
13E207
282 SF
RECEPTION
13E201
10 SF
CLOSET
13C204A
10 SF
CLOSET
13E207A
63 SF
CORRIDOR
13E210
202 SF
CORRIDOR
13E209
TC
EC
C
13C203
13E206B
13E203A
13E201
E
C
E2
E
7A
13E207B
13C204A
C
4B
13E205
13E204
E
3B
13E206A
EX
IS
T.
EXIST.
C
A1
A1
E1
E1
E1
E1
E1
A1
A1
J
A1
A1
A1
A1
E1
B E1
B
E1
E1
E1
J J
E1
E1
J
E1
B
E1
E1
E1
A1
A1
F
J
J J
A1
J A1
F
+60"
+4 4"
EX
IS
T.
EX
IS
T.
FE
C
FEC
C
D
CR
D
CR
CR
CR
SECURITY
CAMERAS AT
EACH ENTRY
SECURITY
CAMERAS AT
EACH ENTRY
D
D
3 3 3 3 3 35555555
R+6 0"
A1
+4 4"
D+7 2"
+4 4"J
D +44"
AE-721H7
H5
H3
AE-411
B4
AE-721
H1
A1
F
F
F
F
1'-6".
9'-11"
MIN.
5'-0"
'-3
'-6
'-3
/2
8'-11 1/4"
M
IN
4' -5
'-6
/4
" MIN.
4'-6".
J
F
'-1
0"
E3
AE-721
13E18
EXIST.
6' -8
7'-8 1/2"
7'-5 1/2"
9' -6
1' -4
/4
6' -1
/4
3'
-1
/4
IG IG
+4 4"
+6 3"
AE-721
F7
+4 4"
IG
F
SECURITY
CAMERAS AT
EACH ENTRY
6' -8
7'-3"
E1
AE-721F1
+44"
+72"
+4 4"
E1
8 888888
F
EXIST.
13E20
B4
AE-201
OPP. SIM
CRCR
D
D
2 2
J
M
IN
1' -6
2'-0"
3'-10 1/2" 10'-3 3/4" 13'-8 1/2" 5'-7 1/4"
1'-4 1/4"
1'-4 1/4"
1' -5
/2
2'-1 1/4"
MIN.
5'-0"
5'-4 1/2" 8'-0 3/4"
1'-4 1/4"
M
IN
5' -0
EQ. EQ.
M
IN
5' -0
5' -7
/4
1. ALL PARTITIONS TO BE TYPE 'A' UNLESS NOTED OTHERWISE.
2. REFER TO SHT AE-601 FOR FINISH AND MATERIAL INFORMATION
3. REFER TO SHT AE-504 FOR PARTITION TYPES. NOT ALL WALL TYPES SHOWN ARE PART
OF THIS PROJECT. COORDINATE WITH PLANS.
4. DETAILS, TYPICAL WALL TYPE CONSTRUCTION AND WALL TYPE INDICATORS ARE
DIAGRAMMATIC AND MUST BE REFERENCED TOGETHER W/ DOOR SCHEDULES,
SECTIONS, ELEVATIONS AND FINISH SCHEDULE TO DETERMINE CORRECT FINISH AND
CONSTRUCTION.
5. MAINTAIN ADA 12"MIN. PUSH AND 18" MIN. PULL CLEARANCES AT ALL DOORS
6. ALL DOOR RETURNS ARE 6" U.N.O
7. FLOOR FINISHES SHALL BREAK AT THE CENTERLINE OF DOORS, U.N.O. FLOAT FLOOR
AS REQUIRED TO ACHIEVE FLUSH ALIGNMENT OF FINISHED SURFACES.
8. PRESERVE AND PROTECT ALL EXISTING WINDOWS.
9. PROTECT EXISTING CONSTRUCTION AND FINISHES THAT ARE NOT AFFECTED BY
CONSTRUCTION, REPAIR OR REPLACE WORK INADVERTENTLY DAMAGED BY
CONSTRUCTION OPERATIONS AT NO ADDITIONAL COST TO OWNER. EXTREME CARE
REQUIRED IN AREAS OF CONSTRUCTION SO AS NOT TO DISTURB ADJACENT AREAS
WHICH ARE IN USE.
10. ALL NEW WALLS TO BE TAPED, BEDDED, TEXTURED, PRIMED & PAINTED- TWO FINISH
COATS. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
11. CONTRACTOR TO CONTAIN ANY/ALL ODORS STRICTLY WITHIN THE CONFINES OF THE
CONSTRUCTION AREAS.
12. CONSTRUCTION NOISE IS TO BE CONTAINED AND MONITORED SO AS TO NOT DISRUPT
ADJACENT BUILDING OCCUPANTS THROUGHOUT CONSTRUCTION.
13. WRITTEN AUTHORIZATION IS TO BE RECEIVED FROM THE GSA PROJECT
MANAGER/REPRESENTATIVE FOR ACCESS TO ADJACENT SPACES IF REQUIRED DURING
CONSTRUCTION. THIS INCLUDES ANY PENETRATIONS THROUGH FLOORS OR WALLS.
14. STRICT ADHERENCE TO GSA/COURTS SECURITY AND BUILDING ACCESS
REQUIREMENTS IS REQUIRED THROUGHOUT CONSTRUCTION.
15. SOUND SEAL ALL PENETRATIONS THROUGH WALLS BETWEEN ROOMS, TYPICAL.
16. CAUTION: DO NOT DISRUPT EXISTING TENANTS OCCUPYING THE BUILDING DURING
THE COURSE OF CONSTRUCTION. ANY UTILITY DISRUPTIONS THROUGHOUT THE
CONSTRUCTION REQUIRES 2 (TWO) WEEKS ADVANCE NOTICE TO THE GSA PROJECT
MANAGER/REPRESENTATIVE.
17. CONTACT THE GSA PROJECT MANAGER PRIOR TO CONSTRUCTION FOR DIRECTIONS
CONCERNING MATERIAL STAGING, BUILDING ACCESS POINTS, HOURS OF OPERATION
AND CONSTRUCTION NOISE CONTROL.
18. FURNITURE IS INCLUDED FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM
FINAL LOCATIONS AND REQUIREMENTS FOR POWER & DATA OUTLETS FOR ALL SYSTEMS
FURNITURE AND OFFICE FURNITURE PRIOR TO CONSTRUCTION. CONTRACTOR IS
RESPONSIBLE FOR FACILITATING ELECTRICAL POWER AND DATA CONNECTIONS TO ALL
FURNITURE REQUIRING THEM WHETHER WALL, FLOOR OR CEILING ACCESS/ MOUNTING.
THIS INCLUDES FINAL CONNECTIONS FOR ELECTRICAL DEVICES.
19. ALL PENETRATIONS THROUGH FIRE WALLS, SHAFTS OR FLOORS TO RECEIVE FIRE
RATED SEALANT AS SPECIFIED.
20. REFER TO FINISH SCHEDULE FOR BREAKROOM FLOORING FINISHES.
21. SECURITY DEVICES (DURESS, CARD READERS, SECURITY CAMERAS, ETC.) ARE
SHOWN FOR COORDINATION PURPOSES ONLY. CONTRACTOR IS RESPONSIBLE FOR
INSTALLING INFRASTRUCTURE TO SUPPORT DEVICES. ACTUAL INSTALLATION AND HOOK
UP OF DEVICES IS NIC.
22. POWER / DATA SHOWN ON THIS SHEET FOR REFERENCE ONLY. CONTRACTOR SHALL
REFER TO ELECTRICAL.
GENERAL NOTES:
LEGEND
D
CR
DR
DURESS ALARM BUTTON
CARD READER
DOOR RELEASE
CCTV MONITOR
CCTV CAMERA
DUPLEX ELECTRICAL OUTLET (REF: ELEC)
TEL/DATA (REF: ELEC)
FLOOR BOX (COMB. POWER/TEL/DATA)
QUADRUPLEX ELECTRICAL OUTLET (REF: ELEC)
ES ELECTRIC STRIKE
J JUNCTION BOX
1i
WALL TYPE (NO SOUND ATTENUATION)
WALL TYPE (SOUND ATTENUATION)
1i
AREA NOT IN SCOPE
STUD PARTITION WALL
EXISTING WALL ASSEMBLY
FLOOR BOX (COMB. POWER/TEL/DATA/)
W/ SPACE FOR DURESS WIRING
EXTENT OF WORK
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE
PROPERLY DESTROY OR RETURN DOCUMENTS WHEN NO LONGER NEEDED
FINISH PLAN NOTES
ALIGN NEW WALL WITH EXISTING WALL2
ALL EXISTING WINDOW A/C UNITS TO REMAIN. CLEAN, REPLACE FILTERS AND
RE-FURBISH UNITS AS REQUIRED. REFINISH GRILLES AND DIFFUSERS, POWDER
COAT TO MATCH HARDWARE. FINAL COLOR TBD (COORDINATE WITH GSA
PROJECT MANAGER AND USDC REPRESENTATIVE FOR COLOR SELECTION).
REPLACE EXISTING GYP. BD. ON TENANT SIDE. REPAIR / REPLACE EXISTING
FRAMING AS REQUIRED. FILL CAVITY W/ SOUND BATT. INSULATION. SEAL ALL
PENETRATIONS W/ ACOUSTIC SEALANT AND EXTEND PARTITION TO DECK.
PROTECT AND REPLACE EXISTING ELECTRICAL OUTLETS AS REQUIRED.
EXISTING DOOR TO REMAIN. CONTRACTOR SHALL SAND AND REFINISH OFF SITE
THE INTERIOR SIDE OF DOOR, ST-1.
5 CONTRACTOR TO INSTALL NEW WINDOW TREATMENTS AS SPECIFIED.
6 EXISTING CMU WALL TO REMAIN. CONTRACTOR TO VERIFY THAT WALL EXTENDS
TO DECK.
7 EXISTING DOOR TO REMAIN. CONTRACTOR SHALL SAND AND REFINISH OFF
SITE THE EXTERIOR SIDE OF DOOR, ST-1.
8 REPLACE / REFINISH EXISTING GYP. BD. @ EXTERIOR WALL CONDITION.
architect
0 client / owner project revision no:
issue date:
gsa order no.:
drawn by:
issue title:
sheet title:
sheet no:
issue date:
checked by:
architects vai seal / disclaimer project team
ARCHITECT OF RECORD
vai architect incorporated 16000 north dallas parkway, suite 200 dallas, texas 75248
972.934.8888 t 972.458.2323 f
MEP/FP ENGINEER
JJA, Inc.
8150 n. central expressway suite M-2100 dallas, texas 75206
214.739.8880 t
GS-P-07-16-UA-7005
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
6/ 7/
:1
0:
P M
AE-101
13TH LEVEL
ENLARGED
FLOOR PLAN
1376 CHAMBERS
REMODEL
DSGC
06/06/2017
100% FINAL
SUBMITTAL
C H
AM
BE
R S
R
EM
O D
EL
1100 Commerce Street, Dallas, Tx. 75242
SCALE: 1/4" = 1'-0"H213TH LEVEL ENLARGED FLOOR PLAN
0 2' 4' 8'
8' - 10"
8' - 10"
8' - 0"
8' - 0"
8' - 10" 8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
349 SF
BREAK ROOM
13E202
151 SF
LAW CLERK
NO.1
13E204
282 SF
RECEPTION
13E201
292 SF
CONFERENCE
ROOM
13E203
180 SF
CORRIDOR
13C200
63 SF
CORRIDOR
13E210
150 SF
LAW CLERK
NO.2
13E205
202 SF
CORRIDOR
13E209
294 SF
RECEPTION
13C201
274 SF
CORRIDOR
13C207
606 SF
JUDGE'S
CHAMBERS #2
13C204
73 SF
PRINT ROOM
13E206
146 SF
LAW CLERK
NO.2
13C203
617 SF
JUDGE'S
CHAMBERS #1
13E207
320 SF
BREAK ROOM
13C206
152 SF
LAW CLERK
NO.1
13C202
88 SF
JUDGE NO.1
REST ROOM
13E208
88 SF
JUDGE NO.2
REST ROOM
13C205
EXIT SIGN
(SHADED AREA REPRESENTS THE ACTUAL
POSITION OF THE EXIT SIGN. ARROW
DIRECTS OCCUPANT TOWARD EXIT.)
RCP LEGEND
RETURN DIFFUSER
SUPPLY DIFFUSER
TOILET EXHAUST FAN
RECESSED CAN DOWNLIGHT
2X2 CEILING TILE AND GRID
2X2 LIGHT FIXTURE
UNDER CABINET LIGHT FIXTURE
NEW 2X2 LIGHT FIXTURE
(CONNECTED TO EMERGENCY
CIRCUIT)
GYP. BD. SURFACE
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE
PROPERLY DESTROY OR RETURN DOCUMENTS WHEN NO LONGER NEEDED
GENERAL RCP NOTES
1. REFER TO MEP FOR PLACEMENT OF MECHANICAL DEVICES / LOCATIONS OF
ELECTRICAL DEVICES, FIXTURES AND EQUIPMENT.
architect client / owner project revision no:
issue date:
gsa order no.:
drawn by:
issue title:
sheet title:
sheet no:
issue date:
checked by:
architects vai seal / disclaimer project team
ARCHITECT OF RECORD
vai architect incorporated 16000 north dallas parkway, suite 200 dallas, texas 75248
972.934.8888 t 972.458.2323 f
MEP/FP ENGINEER
JJA, Inc.
8150 n. central expressway suite M-2100 dallas, texas 75206
214.739.8880 t
GS-P-07-16-UA-7005
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
6/ 7/
:1
0:
P M
AE-201
13TH LEVEL
FLOOR
REFLECTED
CEILING PLAN
1376 CHAMBERS
REMODEL
DSGC
06/06/2017
100% FINAL
SUBMITTAL
C H
AM
BE
R S
R
EM
O D
EL
1100 Commerce Street, Dallas, Tx. 75242
SCALE: 1/4" = 1'-0"H213TH LEVEL REFLECTED CEILING PLAN
0 2' 4' 8'
G
FI
0 2' 4' 6'3/8"=1'
0 2' 4' 6'3/8"=1'
0 2' 4' 6'3/8"=1'
WALL MOUNTING DETAILS
MIN 20 GA MTL STUDS FACING OPPOSITE
DIRECTIONS TO ALLOW MOUNTING
PLATE ATTACHMENT
14 GA STL RUNNER TRACK-
CLIP FLANGES AND FOLD
WEB TO FORM ATTACHMENT
FLANGE
8" MIN, DEEPER IF
REQUIRED
20 GA MTL RUNNER
TRACK - CLIP FLANGES
TO FIT OVER STUDS
3 5/8" MIN DEEPER IF
REQUIRED
MTL WALL STUDS
LIGHT DUTY MOUNTING
RE
FE
R
TY
PI
CA
L
MO
UN
TIN
G
HE
IG
HT
S
CONT 20 GA 4" WIDE
MTL BACK-UP PLATE
MEDIUM DUTY MOUNTING
HEAVY DUTY MOUNTING
RE
FE
R
TY
PI
CA
L
MO
UN
TIN
G
HE
IG
HT
S
RE
FE
R
TY
PI
CA
L
MO
UN
TIN
G
HE
IG
HT
S
GENERAL NOTE
1. WALL MOUNTED EQUIPMENT OR FIXTURES WILL BE
PROVIDED LIGHT DUTY MOUNTING UNLESS NOTED
OTHERWISE
AE-721H7
H5
H3
SS-2 COUNTERTOP AND
BACKSPLASH W/
LAVATORY AS SPECIFIED
WALL MOUNTED LIGHT
SCONCE - REF. ELEC.
FIXTURE SCHEDULE
NEW FLOOR MOUNTED
TOILET AS SCHEDULED
TTD1
+42"
CH
GB42
CONTRACTOR SHALL ADD
2"X10" HEAVY DUTY
RATED WOOD BLOCKING
IN WALL FOR SINK
CONTRACTOR SHALL ADD
2"X10" HEAVY DUTY
RATED WOOD BLOCKING
IN WALL FOR GRAB BARS
MIR2
88 SF
JUDGE NO.2
REST ROOM
13C205
GB36
E1
J
J
J
FLOOR MTD.
DOOR STOP
1' -6
1'
-5
F7
AE-411
SIM/OPP TO
13C208
2'-0" 2'
-1 0"
PT-5
B-2
SS-2 COUNTERTOP AND
BACKSPLASH W/
LAVATORY AS SPECIFIED
SINGLE ROLL TOILET
PAPER DISPENSER AS
SPECIFIED
PROVIDE HEAT
SHIELDING
FOR PIPING
6' -7
" M
IN
9'-0" MIN. W/ PTDW, OR EHD,OR PTD1 + WR2
BELOW;
8'-10" MIN. W/ PTD2
1' -6
" M
IN
C
LR
6' -1
" M
IN
4' -6
" M
IN
. C
LR
IF
D O
O R
H
AS
C
LO
SE
R
1'-4"
CLR.
1'-5"
CLR.
9'-0" MIN. W/ PTDW, OR EHD,OR PTD1 + WR2
BELOW;
8'-10" MIN. W/ PTD2
1'-4"
CLR.
1'-5"
CLR.
3'- 4"
M
AX
. W
HE
N
AB
O
VE
A
LA
V.
O
R
CO
UN
TE
RT
O
P;
3'-
0" M
AX
. W
HE
N
NO
T
AB
O
VE
A
LA
V.
O R
CO
UN
TE
RT
O P
6' -2
" M
IN
2' -1
0"3' -1
0"
5' -0
" A T
N O
N
AC
C
ES
SI
BL
E
VA
R
IE
S
VARIES
VARIES
3'
-1 0"
8" TYP.
2' -2
1' -5
'-7
TO
T
O P
O F
SE
AT
2' -1
0"
8"
3'-6" MIN.
1'-0"
MAX.
6"
1'-4"
CLR.
2' -1
0"
2' -3
" M
IN
C
LR
2' -1
0"
2'-0" MAX.
(1'-6 1/4"
SHOWN)
2' -1
0"
2'-0"
3' -0
" D O
O R
3'-0" DOOR
TTD-
GB42
GB36 GB36
CH
MIR1
CH
MIR1
TTD-
GB42
XXXX
TTD1CH TB##MIR1
MIR2RH GBSH
GB##
TTD1
GB42
MIR1
MIR1 MIR2
BOBRICK
B-165 2436
BOBRICK
B-545 X 18, B-545 X 24
BOBRICK
B-2730
BOBRICK
B-6806
SERIES
COAT HOOK-
BOBRICK B-2116 (SHOWN);
SINGLE ROBE HOOK -
BOBRICK B-6717
BOBRICK
B-6861.99
03D OP.H.
AE-201
E
O P.
H.
C
03B
AE-201 03D OP.H.
AE-201
E
O P.
H.
C
03B
AE-201
KEYED NOTES
TYP. FLOOR PLANS FOR ACCESSIBLE SINGLE OCCUPANT & FAMILY TOILET ROOMS
TOILET ACCESSORY LIST
01 TYP. TOILET ACCESSORY MOUNTING HEIGHTS
SCALE: 3/8"=1'-0"
03 TYP. TOILET ACCESSORY MOUNTING HEIGHTS
SCALE: 3/8"=1'-0"
GENERAL NOTES
05 TYP. PROTRUDING OBJECTS LIMITS
NOTE: REF. TAS/ADA SECTION 307 FOR MORE INFO.
POST MOUNTED OBJECTS HAVE DIFFERENT LIMITS.
04 TYP. ACCESSIBLE REACH RANGE DIAGRAMS
NOTE: REF. TAS/ADA SECTION 308 FOR MORE INFO.07TYP. ACCESSIBLE KNEE & TOE SPACE DIAGRAMS
NOTE: REF. TAS/ADA SECTION 306 FOR MORE INFO.
1. FINISHED WALL SURFACE.
2. TOILET PARTITION WITH 1" NOM. THICKNESS.
3. URINAL SCREEN (OR FINISHED WALL SURFACE WHERE OCCURS).
4. ADJACENT COMPARTMENT WHERE OCCURS.
5. ORIENT HAND-OPERATED FLUSH HANDLE (WHERE OCCURS) TO TRANSFER
SIDE OF WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS & ROOMS.
6. ACCESSIBLE TOILET COMPARTMENT DOORS SHALL BE SELF-CLOSING, & AN
ACCESSIBLE DOOR PULL HANDLE BY TOILET PARTN. MFR. SHALL BE MOUNTED
ON BOTH SIDES OF DOOR.
7. COAT HOOK BY TOILET PARTN. MFR., MOUNTED WITH TOP AT 4'-0" A.F.F. &
CENTERED ON PUSH SIDE OF DOOR. AT ADJACENT PERPENDICULAR WALL
WHERE OCCURS, PROVIDE DOOR STOP AS REQD. BY TOILET PARTN. MFR. ON
PULL SIDE OF DOOR (NOT SHOWN).
8. COAT HOOK / DOOR BUMPER BY TOILET PARTN. MFR.
9. 5'-0" DIAMETER WHEELCHAIR TURNING SPACE.
10. 2'-6" X 4'-0" MIN. CLEAR FLOOR SPACE.
11. 3'-0" X 4'-0" MIN. CLEAR FLOOR SPACE.
12. 3'-0" X 5'-0" MIN. CLEAR FLOOR SPACE.
13. 5'-0" W." X 4'-11" D. MIN. CLEAR COMPARTMENT SPACE FOR FLOOR MOUNTED
W.C., OR 5'-0" W." X 4'-8" D. MIN. CLEAR FOR WALL MOUNTED W.C.
14. 5'-0" W." X 4'-8" D. MIN. CLEARANCE AT TOILET ROOM FOR FLOOR OR WALL
MOUNTED W.C.
15. 2'-11" W. X 5'-0" D. MIN. CLEAR COMPARTMENT SPACE. CLEAR WIDTH OF
AMBULATORY ACCESSIBLE STALL SHALL NOT EXCEED 3'-1" MAX.
16. 9" H. MIN. A.F.F. X 6" W. MIN. TOE SPACE CLEARANCE OUTSIDE OF WHEELCHAIR
ACCESSIBLE TOILET COMPARTMENT AT FRONT & SIDE OPPOSITE W.C. (NOT
REQUIRED AT SIDE OF COMPARTMENTS WIDER THAN 5'-6" AND AT FRONT OF
COMPARTMENTS DEEPER THAN 5'-5".) TOE SPACE IS EXCLUSIVE OF TOILET
PARTITION SUPPORTS EXTENDING TO FLOOR.
17. 5'-0" D. X [DOOR WIDTH + 18"] MIN. CLEAR FLOOR SPACE FOR DOOR FRONT
APPROACH, PULL SIDE.
18. 4'-6" D. X [DOOR WIDTH + 24"] MIN. CLEAR FLOOR SPACE FOR DOOR LATCH
APPROACH, PULL SIDE, TO DOOR WITH CLOSER (4'-0" D. MIN. REQD. FOR DOOR
WITHOUT CLOSER).
19. 4'-0" D. X [DOOR WIDTH + 12"] MIN. CLEAR FLOOR SPACE FOR DOOR FRONT
APPROACH, PUSH SIDE, TO DOOR WITH CLOSER & LATCH.
20. 4'-0" D. X [DOOR WIDTH + 24"] MIN. CLEAR FLOOR SPACE FOR DOOR LATCH
APPROACH, PUSH SIDE, TO DOOR WITH CLOSER (3'-6" D. MIN. REQD. FOR DOOR
WITHOUT CLOSER).
21. 2'-6" W." MIN. X 2'-3" H. MIN. KNEE CLEARANCE & 2'-6" W." MIN. X 6" D. MAX. X 9" H.
MIN. TOE CLEARANCE.
22. WHEELCHAIR ACCESSIBLE WALL MOUNTED LAVATORY- 20 1/2" W. X 18 1/4"
FRONT TO BACK NOMINAL DIMENSIONS. BASIS OF DESIGN U.N.O.- AMERICAN
STANDARD 'LUCERNE'. PROVIDE MOLDED VINYL PIPING PROTECTION FOR
EXPOSED WASTE & SUPPLY PIPING. BASIS OF DESIGN U.N.O.- TRUEBRO 'LAV
GUARD 2 E-Z'.
23. PREFABRICATED SHOWER UNIT OR FIELD-BUILT SHOWER WITH
PREFABRICATED SHOWER PAN, FIXED SHOWER HEAD, 4" MAX. HT. THRESHOLD,
& CENTER DRAIN LOCATION U.N.O. CENTER SHOWER HEAD & CONTROLS ON
CONTROL WALL.
24. TRANSFER TYPE PREFABRICATED SHOWER UNIT OR FIELD-BUILT SHOWER
WITH CENTER REAR DRAIN. 3'-0" X 3-0" CLEAR SIZE AS NOTED IS CRITICAL. 3'-0"
X 4'-0" MIN. CLEAR FLOOR SPACE ADJACENT TO SHOWER SHALL EXTEND 1'-0"
PAST SEAT WALL AS SHOWN & MAY NOT BE FLIPPED.
25. ROLL-IN TYPE PREFABRICATED SHOWER UNIT OR FIELD-BUILT SHOWER WITH
CENTER DRAIN & WITHOUT BUILT-IN SEAT.
26. SLIDING HAND HELD SHOWER ASSEMBLY WITH REMOVABLE SPRAY HEAD, 1
1/2"� X 3'-0" L. VERT. WALL BAR & 70" L. FLEXIBLE HOSE. WALL BAR SHALL BE
DUAL PURPOSE GRAB BAR & SLIDE BAR. BASIS OF DESIGN U.N.O.- DELTA #
52003-UF.
27. SHOWER CONTROL / MIXING VALVE.
28. 1/2" H. THRESHOLD WITH 1:2 BEVELED EXPOSED EDGE(S) OR APPROVED
TAS/ADA COMPLIANT EQUIVALENT. EXCEPTION: AT EXISTING FACILITIES
WHERE THE CONSTRUCTION OF A SHOWER PAN WITH A 1/2" H. THRESHOLD
WOULD DISTURB THE REINFORCEMENT OF THE FLOOR SLAB, A 2" H. (MAX.)
THRESHOLD MAY BE PROVIDED FOR ACCESSIBLE TRANSFER SHOWER STALLS.
29. AT PREFABRICATED SHOWER UNIT, PROVIDE MOLDED SOAP LEDGE IN CORNER
AT 3'-8" A.F.F. MAX. AT FIELD-BUILT SHOWER, PROVIDE WALL MOUNTED
RECESSED SOAP DISH 'SPDH' AS SCHEDULED 4" CLR. FROM CORNER ON
CONTROL WALL .
30. INCREASE CLEARANCE OR COUNTER LENGTH AS REQD. TO MAINTAIN INDICATED
MIN. CLEARANCE FROM C.L. OF LAVATORY TO FACE OF PROTRUDING OBJECTS
MOUNTED ON SIDE WALL(S) IN FRONT OF LAVATORIES / COUNTERTOP.
31. COUNTERTOP- REF. PROJECT SPECIFIC DRAWINGS FOR CONSTRUCTION.
PROVIDE PIPING PROTECTION FOR ALL SINKS WHETHER ACCESSIBLE OR NOT.
MOLDED VINYL PIPING PROTECTION IS NOT REQUIRED WHERE PIPING IS
CONCEALED BEHIND A REMOVABLE PANEL.
32. COUNTERTOP W/ BACKSPLASH & DOUBLE OR SINGLE COMPARTMENT SINK.
PROVIDE PIPING PROTECTION FOR SINK. MOLDED VINYL PIPING PROTECTION
IS NOT REQUIRED WHERE PIPING IS CONCEALED BEHIND A REMOVABLE PANEL.
33. LINE OF BASE CABINET SIDE PANEL OR SIDE PARTITION WHERE OCCURS.
34. SLOPED REMOVABLE PANEL(S) FOR PIPING PROTECTION WHERE INDICATED ON
PROJECT-SPECIFIC DRAWINGS. IF NO PANEL, PROVIDE MOLDED VINYL PIPING
PROTECTION.
35. WALL-MOUNTED HIGH / LOW ELECTRIC WATER COOLER OR DRINKING FOUNTAIN.
36. ADJACENT SIDE WALL OR WING WALL WHERE OCCURS.
37. WHERE REQD. FOR TAS/ADA COMPLIANCE, PROVIDE APRON BY EWC MFR. (OR
APPROVED EQUIVALENT) FOR CANE DETECTION OF PROTRUDING OBJECT.
1. GUIDELINES HAVE BEEN DESIGNED WITH THE INTENT TO COMPLY WITH ALL
CURRENT 2012 TEXAS ACCESSIBILITY STANDARDS & 2010 ADA STANDARDS FOR
ACCESSIBLE DESIGN. INSTALLED ACCESSORIES, FIXTURES & EQUIPMENT
SHALL COMPLY WITH TAS/ADA REQUIREMENTS AS REQD.
2. REFER TO FOLLOWING SHEET FOR TOILET ACCESSORY LIST & ADDITIONAL
RELATED INFORMATION.
3. DIMENSIONS NOTED AS CLEAR (CLR.) ARE FROM FACE OF FINISHED WALL /
PARTITION SURFACE, DOOR JAMB, &/OR CENTERLINE OF FIXTURE / ACCESSORY U.N.O
4. DIMENSIONS SHOWN ARE FOR ADULTS AND CHILDREN ABOVE 12 YEARS OF AGE.
SPACES THAT ARE PRIMARILY DESIGNED FOR CHILDREN 12 YEARS OF AGE OR
YOUNGER REQUIRE DIFFERENT DIMENSIONS- REF. TAS/ADA SECTION 604.9,
ADVISORY 308.1, ETC. AS REQD.
5. REFER TO PROJECT-SPECIFIC DRAWINGS FOR ACTUAL LAYOUT OF
COMPARTMENTS AND ROOMS. MINIMUM, MAXIMUM, & CLEAR DIMENSIONS SHALL
BE MAINTAINED AS INDICATED ON THIS SHEET. LAYOUTS MAY BE OPPOSITE HAND.
6. REFER TO PLUMBING, MECHANICAL, & ELECTRICAL FOR ADDITIONAL INFORMATION.
7. 2'-6" (OR 3'-0") X 4'-0" MIN. CLEAR FLOOR SPACE FOR ACCESSIBLE PLUMBING
FIXTURES SHALL BE ORIENTED FOR FORWARD APPROACH U.N.O., & SHALL
INCLUDE ACCESSIBLE KNEE & TOE CLEARANCE. MIN. CLEAR FLOOR SPACE
SHALL BE CENTERED ON PLUMBING FIXTURE.
8. EXPOSED WATER SUPPLY & DRAIN PIPING UNDER ACCESSIBLE LAVATORIES OR
SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES
UNDER ACCESSIBLE LAVATORIES OR SINKS.
9. VERIFY & COMPLY WITH MFR'S. RECOMMENDED MINIMUM CLEARANCES
REQUIRED FOR ACCESSORY & EQUIPMENT MAINTENANCE & DISPENSER
REFILLING PROCEDURES.
10. NOT ALL KEYED NOTES ARE REFERENCED ON THIS SHEET.
14 10
TYPE TR-C1
ACCESSIBLE TOILET ROOM-
SINGLE OCCUPANT OR FAMILY TOILET W/ STRAIGHT PLUMBING WALL
& INSWINGING DOOR
14 10
TYPE TR-D1
ACCESSIBLE TOILET ROOM-
SINGLE OCCUPANT OR FAMILY TOILET W/ STRAIGHT PLUMBING WALL
& INSWINGING DOOR
22 22
BCS1 SURFACE-MOUNTED FOLD-DOWN BABY CHANGING STATION.
BCS2 RECESSED FOLD-DOWN BABY CHANGING STATION.
CH COAT HOOK.
GB## 1 1/2" DIA. HORIZ. GRAB BAR WITH STRAIGHT RUN. NUMBER SUFFIX INDICATES
LENGTH IN INCHES.
GBSH 1 1/2" DIA. HORIZ. GRAB BAR FOR ACCESSIBLE TRANSFER SHOWER, EXTENDING
ACROSS THE CONTROL WALL & RETURNING 18" L. ALONG THE BACK WALL.
EHD ELECTRIC HAND DRYER.
FRGD AUTOMATIC FRAGRANCE DISPENSER.
HSD HAND SANITIZER DISPENSER.
MBHS MOP & BROOM HOLDER WITH SHELF & RAG HOOKS.
MIR1 METAL CHANNEL FRAMED GLASS MIRROR- 2'-0" W. X 3'-0" H. U.N.O.
MIR2 CUSTOM SIZE GLASS MIRROR- REF. PROJECT-SPECIFIC ELEVATION(S)
FOR SIZE.
PTD1 ROLL PAPER TOWEL DISPENSER PROJECTING MORE THAN 4" FROM WALL
SURFACE.
PTD2 ROLL (OR C-FOLD) PAPER TOWEL DISPENSER PROJECTING 4" OR LESS FROM
WALL SURFACE.
PTDW SEMI-RECESSED COMBINATION ROLL (OR C-FOLD) PAPER TOWEL DISPENSER
& WASTE RECEPTACLE.
RH ROBE HOOK.
SHCR SHOWER CURTAIN ROD WITH LENGTH AS REQD. PROVIDE SHOWER CURTAIN &
HANGER CLIPS WHERE INDICATED IN PROJECT-SPECIFIC DWGS. OR SPECS .
SHST FOLD-DOWN L-SHAPED SHOWER SEAT.
SNDP1 SURFACE-MOUNTED SANITARY NAPKIN DISPOSAL- PROVIDE AT WOMEN'S &
UNISEX TOILETS ONLY.
SNDP2 RECESSED SANITARY NAPKIN DISPOSAL- PROVIDE AT WOMEN'S &
UNISEX TOILETS ONLY.
SNV1 SEMI-RECESSED SANITARY NAPKIN VENDOR.
SNV2 RECESSED SANITARY NAPKIN VENDOR.
SPD1 SOAP DISPENSER- WALL MOUNTED.
SPD2 SOAP DISPENSER- COUNTER, LAVATORY, OR SINK MOUNTED.
SPDH RECESSED SOAP DISH- WALL MOUNTED.
TB## TOWEL BAR. NUMBER SUFFIX INDICATES LENGTH IN INCHES.
TSCD1 SURFACE-MOUNTED TOILET SEAT COVER DISPENSER.
TSCD2 RECESSED TOILET SEAT COVER DISPENSER.
TTD1 SINGLE STANDARD ROLL TOILET TISSUE DISPENSER.
TTD2 MULTI-ROLL TOILET TISSUE DISPENSER- HORIZ. ORIENTATION.
TTD3 MULTI-ROLL TOILET TISSUE DISPENSER- VERT. ORIENTATION.
TTD4 DUAL-SIDED MULTI-ROLL TOILET TISSUE DISPENSER FOR ADJACENT PAIR OF
TOILET COMPARTMENTS.
TTDJ1 SINGLE JUMBO ROLL TOILET TISSUE DISPENSER.
TTDJ2 DOUBLE JUMBO ROLL TOILET TISSUE DISPENSER.
WR1 SEMI-RECESSED WASTE RECEPTACLE.
WR2 SURFACE-MOUNTED WASTE RECEPTACLE.
WR3 FREESTANDING WASTE RECEPTACLE.
THE FOLLOWING LIST IS GENERIC. REFER TO PROJECT-SPECIFIC TOILET ACCESSORY
SCHEDULE FOR ACTUAL PRODUCTS. SOME ACCESSORIES LISTED MAY NOT BE IN PROJECT
SCOPE. PROVIDE ACCESSORIES WITH DASHED ID TAGS ON PLANS & ELEVATIONS ON THIS
SHEET ONLY IF INDICATED IN PROJECT-SPECIFIC DRAWINGS OR SPECS.
9 9
B.O. REFLECTIVE
SURFACE
T.O.
REFLECTIVE
SURFACE
T.O. HOOK
C GRAB BARL
T.O. BAR
FRONT EDGE OF W.C.
C TTD
LC SPINDLE
LIGHT DUTY
MOUNTING
HEAVY
DUTY
MOUNTING
MEDIUM DUTY
MOUNTING
MEDIUM DUTY
MOUNTING
LIGHT DUTY
MOUNTING
ELEVATION OF GRAB BAR
(WHERE OCCURS)
WALL OR FLOOR
MOUNTED W.C.- TYP.
SIDE ELEVATION-
ACCESSIBLE WATER
CLOSET
C TTDL
E
FRONT EDGE OF W.C.
FRONT ELEVATION-
ACCESSIBLE WALL MTD. LAVATORYB
FIN. FLR.- TYP.
C LAV. & MIRRORL
FRONT RIM
OF LAV.
SIDE ELEVATION-
ACCESSIBLE WALL MTD.
LAVATORY
A
HIGHER OF:
TOP OF
COUNTER OR
RIM OF SINK
D
C
FIN. FLR.
UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACHTOE SPACE
ELEVATION PLAN
KNEE SPACE
ELEVATION PLAN
L
SCALE: 3/8"=1'-0"
1' -5
'-7
TO
T
O P
O F
SE
AT
3'-0" MIN.
1'-0"
MIN.
2' -1
0"
1'-5"
CLR.
2'-0" MIN.
5" MAX.
GB36
FRONT ELEVATION-
WHEELCHAIR ACCESSIBLE WATER
CLOSET
C W.C.L
TRANSFER
SIDE
SECTION-
ACCESSIBLE COUNTER MTD.
LAVATORY
*SHOWN FOR REFERENCE ONLY *SHOWN FOR REFERENCE ONLY
*SHOWN FOR REFERENCE ONLY
architect client / owner project revision no:
issue date:
gsa order no.:
drawn by:
issue title:
sheet title:
sheet no:
issue date:
checked by:
architects vai seal / disclaimer project team
ARCHITECT OF RECORD
vai architect incorporated 16000 north dallas parkway, suite 200 dallas, texas 75248
972.934.8888 t 972.458.2323 f
MEP/FP ENGINEER
JJA, Inc.
8150 n. central expressway suite M-2100 dallas, texas 75206
214.739.8880 t
GS-P-07-16-UA-7005
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
6/ 7/
:1
0:
P M
AE-411
TOILET
LAYOUTS &
ACCESSORIES
1376 CHAMBERS
REMODEL
DSGC
06/06/2017
100% FINAL
SUBMITTAL
C H
AM
BE
R S
R
EM
O D
EL
1100 Commerce Street, Dallas, Tx. 75242
SCALE: 1/2" = 1'-0"B4ENLARGED FLOOR PLAN - RESTROOM, TYP.
SCALE: 3/4" = 1'-0"F7SECTION THRU LAVATORY
0 1' 2' 4'
0 2'6" 1'
PARTITION TYPE GENERAL NOTES
0 1' 2' 3'
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
1 LAYER 5/8" GYP. BD. ON
1 SIDE OF MTL. STUDS AT
16" O.C. MAX.
FLOOR STRUCTURE
FINISH FLOORING AS SCHED.
WALL BASE TRIM AS SCHED.
FLOOR OR ROOF STRUCTURE
REMARKS
FURRING
UL DESIGN NO.
N.A.
TYPE
J#
FIRE RATING
NON-RATED
CEILING AS SCHED.
(WHERE OCCURS)
MTL. BRACING AS REQD. AT
EACH STUD- SPACE AT 4'-0" O.C.
MAX. VERT. FOR 1 5/8" STUDS
FACE OF ADJACENT
WALL OR STRUCTURE
UNFACED THERMAL BATT
INSULATION WHERE SCHED.
STC*
30 / 34
*NO BATT / WITH 3 1/2" THERMAL BATT;
STC SHOWN FOR 20 GA. 3 5/8" STUDS
MTL. TRACK FASTENED TO
FLOOR SLAB
SEALANT
MTL. SLOTTED DEEP LEG
DEFLECTION TRACK
ACOUSTIC SEALANT
1 LAYER 5/8" GYP. BD. ON
1 SIDE OF VERT. 7/8" MTL.
FURRING CHANNELS AT
16" O.C. MAX.
FLOOR STRUCTURE
FINISH FLOORING AS SCHED.
WALL BASE TRIM AS SCHED.
REMARKS
FURRING
STC
UL DESIGN NO.
N.A.
TYPE
F
FIRE RATING
NON-RATED
CEILING AS SCHED.
FACE OF ADJACENT
WALL OR STRUCTURE
FLOOR OR ROOF STRUCTURE
SEALANT
(2) LAYERS - (1) LAYER 5/8"
TYPE X GYP. BD. AND (1)
LAYER 5/8" SOUND RATED
GYP.BD. ON MTL.
STUDS AT 16" O.C. MAX.
FLOOR STRUCTURE
FINISH FLOORING AS SCHED.
WALL BASE TRIM AS SCHED.
FLOOR OR ROOF STRUCTURE
CEILING AS SCHED.
(WHERE OCCURS)
SAB WHERE SCHED.
REMARKS
STC*
*NO SAB / WITH 3" SAB;
STC SHOWN FOR 25 GA. 3 5/8" STUDS
UL DESIGN NO.
U465
TYPE
E# E#-S E#-1
FIRE RATING
NON-RATED
SMOKE RESISTANT
1 HOUR FIRE RATED
MTL. TRACK FASTENED TO
FLOOR SLAB
SEALANT EACH SIDE
MTL. SLOTTED DEEP LEG
DEFLECTION TRACK
ACOUSTIC SEALANT EACH SIDE
1 LAYER 5/8" GYP. BD. ON
EACH SIDE OF MTL. STUDS
AT 16" O.C. MAX.
FLOOR STRUCTURE
FINISH FLOORING AS SCHED.
WALL BASE TRIM AS SCHED.
FLOOR OR ROOF STRUCTURE
SAB WHERE SCHED.
MTL. STUD BRACING TO
STRUCT. ABOVE AT DOOR
LATCH JAMB & AS REQD. FOR
STABILITY
CONT. 4'-0" WIDE X 3" THK. SAB
STRADDLING TOP OF PARTITION
WHERE SAB ARE SCHED.
CEILING AS SCHED.
MTL. TRACK
MTL. TRACK FASTENED TO
FLOOR SLAB
SEALANT EACH SIDE
TYP. SCALE: 3/4"=1'-0"
C3 C3
A-###
TYPE J
TYPE F
A-###
TYPE E
TYPE B
PARTITION DESIGNATION TAGS ( )…
This is the start of the file's text. The full file is on GovTribe.