| District | Lab Location | Instrument(s) for initial install | Estimated tests conducted monthly | Data Mgt. System Work Stations per Lab | Restrictions (known) |
| SD/FL | TBD | (2) instruments capable of no less than 100 tests per hour | 5,575 | 2 | 1. Approximately 250 sq ft, 2. Analyzer is not attached to any water source, 3. No physical restrictions to move equipment |
| PTS/PC | U.S. Courthouse | no availability to dedicate a water system, bottled H20 | | | |
| 400 North Miami Avenue | | | | |
| 9th Floor, South | | | | |
| Miami, FL 33128 | | | | |
| SD/IN | TBD | (1) instrument capable of no less than 100 tests per hour | 2,388 | 1 | 1. 80 sq ft, 2. Water Waste is 3.5 ft away, 3. door to lab is 30 inches wide |
| U.S. Courthouse | | | | |
| 46 East Ohio Street | | | | |
| Room 101 | | | | |
| Indianapolis, IN 46204 | | | | |
| ED/NY | U.S. Probation Office | (1) instrument capable of no less than 100 tests per hour | 3,392 | 1 | Unknown |
| 27 Johnson Street | | | | |
| Room 1525 | | | | |
| Brooklyn, NY 11201 | | | | |
| ED/NY | TBD | (1) instrument capable of no less than 100 tests per hour | 1,916 | 1 | 1.120 sq ft, 2. No direct lines to water source, 3. No moving restrictions |
| U.S. Courthouse | | | | |
| 202 Federal Plaza | | | | |
| 2nd Floor | | | | |
| Central Islip, NY 11722 | | | | |
| SD/NY | TBD | (1) Instrument capable of no less than 100 tests per hour | 944 | 1 | 1.120 sq ft, 2. No direct lines to water source, 3. No moving restrictions |
| U.S. Courthouse | | | | |
| 500 Pearl Street | | | | |
| New York, NY 10007 | | | | |
| (U.S. Pretrial Services) | | | | |
| possible future regional Lab | | | | |
| SD/NY | TBD | (1) Instrument capable of no less than 100 tests per hour | 3,552 | 1 | 1.120 sq ft, 2. No direct lines to water source, 3. No moving restrictions |
| U.S. Courthouse | | | | |
| 500 Pearl Street | | | | |
| New York, NY 10007 | | | | |
| (U.S. Probation Office) | | | | |
| possible future regional Lab | | | | |
| WD/NY | TBD | (1) instrument capable of testing no less than 400 tests per hour | 10,850 | 2 | 1. 253 sq ft, 2. No direct water lines, 3. No moving restrictions |
| U.S. Courthouse | | | | |
| 2 Niagara Square | | | | |
| Room 140 | | | | |
| Buffalo, NY 14202 | | | | |
| Regional Lab | | | | |
| ED/VA | Albert V. Bryan Courthouse | (1) instrument capable of testing no less than 400 tests per hour | 6,053 | 1 | 1. 275 sq ft, Triangular Shape, 2. Water source is nearby, 3. Will require disassembly |
| 401 Courthouse Square | | | | |
| Pretrial Office, 3rd Floor | | | | |
| Alexandria, VA 22314 | | | | |
| SD/CA | TBD | (2) instruments capable of testing no less than 800 tests per hour | 45,153 | 5 | 1. 216 sq ft,2. Water source is approximately 15 feet away, 3. There is a low clearance to the loading dock. The truck cannot be taller than 13'7". Deliveries are to be inside. On the 6th floor and the freight elevator has a weight limit. There is a narrow hallway and the door to the lab is 32 inches wide. |
| U.S. Courthouse | | | | |
| 333 West Broadway | | | | |
| Suite 600 | | | | |
| San Diego, CA 92101 | | | | |
| Regional Lab | | | | |
| MD/FL | TBD | (1) instrument capable of testing no less than 400 per hour | 7,114 | 2 | 1. 406 sq ft, 2. Water source 1 foot away, 3. No restrictions |
| U.S. Courthouse | | | | |
| 300 North Hogan Street | | | | |
| Suite 2-220 | | | | |
| Jacksonville, FL 32202 | | | | |
| ND/IL | TBD | (2) instruments capable of no less than 100 tests per hour | 5,754 | 2 | 288 sq feet approx. with a 75 sq feet for storage, main water source is approx 5 feet away. Loading dock in subfloor - clearance 13.6'. Located on 15th floor. Freight elevator door 5' feet wide, Access door to office is 32"; lab door 34". Lab has two lines of sewer for connection with the analyzers. |
| U.S. Courthouse | | | | |
| 219 South Dearborn St. | | | | |
| Room 15100 | | | | |
| Chicago, IL 60604 | | | | |
| possible future regional Lab | | | | |
| D/NM | TBD | (2) instruments capable of no less than 800 tests per hour | 66,982 | 6 | 480 sq ft, 2. Approximately 72 inches between each analyzer and H2O source, 3. On the 10th floor, east hallway closed, which limits maneuverability from the elevator |
| U.S. Courthouse | | | | |
| 333 Lomas BLVD | | | | |
| Albuquerque, NM 87102 | | | | |
| D/NM | | | | |
| Regional Lab | | | | |
| WD/TX | Federal Building | (2) instruments capable of no less than 800 tests per hour | 34,416 | 3 | 1. 234 sq ft, 2. Water source - 8 feet away, and 2 feet away, 3. No moving restrictions |
| 727 East Durango BLVD | | | | |
| San Antonio, TX 78206 | | | | |
Regional Lab
| WD/WA | | (1) instrument capable of no less than 400 tests per hour | 6,383 | 1 | 1. 826 sq ft, 2. Water source 6 feet away, piped water purification, 3. No moving restrictions . |
| U.S. Courthouse | | | | |
| 700 Stewart Street | | | | |
| Suite 10101 | | | | |
| Seattle, WA 98101 | | | | |
| ED/MO | TBD | (2) instruments capable of no less than 800 tests per hour | 34,348 | 2 | 1. 600 sq ft (60' x 10'), 2. Water source 3 feet and 8 feet away, 3. Narrow doors |
| U.S. Courthouse | | | | |
| 11 South Tenth Street | | | | |
| St. Louis, MO 63102 | | | | |
| Regional lab | | | | |
| D/PR | Federico Degtau | (2) instruments capable of no less than 100 tests per hour | 6,044 | 2 | Unknown |
| Federal Building Bldg. | | | | |
| 150 Carlos Chardon Street | | | | |
| Room 234 | | | | |
| San Juan, PR 00918 | | | | |
| D/MA | John Joseph Moakley | (1) instrument capable of no less than 400 tests per hour | 7,114 | 1 | 1. 450 sq ft, 2. Water source 1 foot away, 3. No restrictions |
| U.S. Courthouse | | | | |
| 104 Dean Street | | | | |
| Suite 102 | | | | |
| Taunton, MA 02780 | | | | |
| Regional Lab | | | | |
| NC/W | Charles R. Jonas Courthouse | (1) instrument capable of no less than 400 tests per hour | 5,838 | 1 | Loading dock access request must be received by 2pm two business days prior to delivery. Maximum height for any vehicle entering through the security gate off 4th Street must not exceed 12FT 6 In height by physical measurement |
| 401 West Trade Street | Millipore H2O | | | |
| Room 500 | | | | |
| Charlotte, NC 28202 | | | | |
ATTACHMENT 2
Approved on-site laboratories requiring initial set-up post award USCA25R0183 - National ONSITE DRUG LAB Locations
&P