Area 1 Fire Skid Sprayer
Solicitation number
26-422DNR-RESCO-B-51924
Issued by
Illinois

About this file

This is a specification document from the Illinois Department of Natural Resources and Illinois Nature Preserves Commission detailing required specifications for a fire skid sprayer to be mounted on utility terrain vehicles. The skid must not exceed 51 inches wide by 32 inches deep and includes a 50-60 gallon baffled polypropylene tank with integrated fill tower, lift handles, and water level visibility features. The equipment must feature a high-pressure, low-volume diaphragm pump with a maximum flow of 9.6 gallons per minute and maximum pressure of 580 psi, powered by a minimum 5 horsepower gas engine with 163 cubic centimeter displacement. The hose system consists of 250 feet of 3/8-inch diameter hose with 500 psi burst rating mounted on a rear-facing electric reel with at least 275-foot capacity and four-sided roller guide. All components must be chemical resistant and compatible with water-based pesticides, with a pistol-style multiple spray pattern nozzle equipped with a quick disconnect.

The specifications document prescribes detailed equipment requirements including a high-pressure mounted plumbing system with inline water strainer/filter, pressure regulator with gauge and two outlets, cold weather recirculation connection, and hose reel lock. The engine must be gas-powered with transistorized magneto ignition and either recoil or electric start capability with low oil alert functionality. Hose and component placement is specified with the hose reel positioned on the driver side facing the vehicle's rear and the engine and pump located on the passenger side. The document explicitly prohibits inclusion of a foam reservoir and indicates preferences for yellow or red hose color and 3/8-inch hose diameter over the acceptable but less-preferred 1/2-inch alternative.

View the file

Other files

File Type Posted
standard terms-conditions~7.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Illinois Department of Natural Resources / Illinois Nature Preserves Commission Fire skid specifications 8/13/2025

General Specs:

· Skid must be a maximum of 51” wide x 32” deep

· Hose reel on driver side facing back of vehicle. Engine and pump on passenger side.

· All components chemical resistant and compatible with spraying water-based pesticides.

Tank:

· 50-60 gallon baffled tank with drain plug toward rear of UTV. Tank must fit within dimensions listed above.

· Includes sump to pump all water from tank

· ½” polypropylene integrated tank with fill tower

· Integrated lift handles

· Water level (e.g. sight glass, clear panel, or gauge) located at rear of tank

· Cold weather recirculate connection

· High pressure mounted plumbing

· Inline water strainer/filter

· Do NOT include a foam reservoir

Pump:

· High pressure low volume diaphragm pump

· Max flow: 9.6 gpm

· Max. Pressure: 580psi

· ¾” solid thru-shaft with gear reduction for 5 hp gas engine (minimum horsepower)

· Regulator with pressure gauge and two outlets

Hose, Reel & Nozzle:

· 250ft of 3/8” hose. 1/2” hose acceptable but not preferred. 500 psi burst rated. Abrasion, puncture, and heat resistant. Preferred color yellow or red.

· Hose with crimped swivels on both ends and a quick disconnect for spray nozzle.

· Rear facing electric reel with at least 275ft capacity of 3/8” high pressure hose (or 1/2" hose if used) with four-sided roller guide.

· Hose reel lock

· Electric reel pigtail for direct wire to vehicle

· Pistol style multiple spray pattern nozzle (direct to more open) with matching quick disconnect to hose.

Engine:

· Gas powered

· 4.8 hp (sometimes called 5hp)

· 163 cubic centimeter displacement

· 4 stroke air cooled

· Transistorized magneto ignition

· Recoil or electric start type

· Low oil alert

File details come from the government source that posted it. Updated .