This document is a detailed equipment specification sheet for a Peripheral Vascular Diagnostic System for a VA (Veterans Affairs) project located in Tulsa. The UNETIXS MultiLab Series 2-CP ultrasound system is a comprehensive vascular diagnostic device with advanced features including composite ergonomic Doppler probes, dual-channel pulse-volume recording, photoplethysmography, an 8.5" color touch screen, and a wireless remote. The system weighs 18 lbs, operates on Windows XP, includes three USB ports, and has DICOM compatibility.

The equipment will be installed in the Radiology Service, specifically in Ultrasound Room-1A124, with installation to be performed by the government. The cart specifications include dimensions of 21" x 24" x 40", weighing 38 lbs, with 4" swivel and locking casters, and storage for cuffs and probes. Electrical requirements are 120 VOLT with a special outlet, and no third-party installation is planned. The specification sheet is dated April 24, 2025, and is part of the Concourse Federal Group's project documentation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Name:

Project Location:

Cat Code:

TULSA

VV April 24, 2025Date Prepared:

JSN: X2100A

VAProject Type:

Project Continent:Project Area:

Model Name: Peripheral vascular diagnostic systemManufacturer: UNETIXS

Dealer:

Phone:

Nomenclature: Scanner, Ultrasound, Vascular

Model Number: MultiLab Series 2-CP

Email: Room Nbr(s): See Attached

Model URL:Manuf URL:

Dimensions

D 45.00 in W 27.00 in H 64.00 in D 685.80 mm W 1,143.00 mm H 1,625.60 mm

Image

All Images are for representation only, may not reflect final product.

Cat Code:

TULSA

VV April 24, 2025Date Prepared:

JSN: X2100A

VAProject Type:

Project Continent:Project Area:

Salient Characteristics Vascular ultrasound with a cart.

General Specifications Instrument Features:

• Composite Ergonomic TruDop® Doppler Probes

• Calibrated Dual-Channel Pulse-Volume Recording (C-PVR)

• Dual-Channel UltraSense Photoplethysmography (PPG)

• Soft-Touch Dual PPG Digit Clips

• 8.5” Diagonal T.F.T Color Touch Screen

• Full-Function Wireless Remote

• Weight-Complete: 18 lbs.

• Built-in CPU, Hard Disk Drive

• Three USB Ports

• Windows XP Operating Platform

• Available DICOM

• Raynaud Study Capability

• Rear Panel Outputs for:

– Color Printer, VGA Color Monitor

– External Keyboard, Serial Port

– Network-Compliant Optional Software:

• MultiLab® and Revo® Rep Accreditation Software Standard Accessories:

• Color Page Printing (HP usually supplied)

• Multi-port Electronic Cuff Selector

• Full-Function External Remote Keyboard

• Complete Set of Pressure Cuffs to Perform All Studies

• Bilateral Testing Capabilities

• Custom Software-Configurable Protocols

• Custom Software-Configurable Test Reports Electronic Cuff Manifold Features:

• 10-Cuff Simultaneous Hookup

• Full-Function Remote Control for Automatic Inflation, Deflation, Capture, Forward, Back, Scrolling and more Cart Specifications:

• 21” x 24” x 40”

• 38 lbs. Total Weight

• 4” Swivel and Locking Casters

• Cuff and Probe Storage

• Miniature Full-Function Keyboard

• Printer Compartment

• Ultrasound Gel Holder

NEMA Type:

Data: Yes

Wall Blocking:

Warranty:

Training:

N/A N/A

No No

DC: No Amps: N/A

EP: No

Plumbing: N/A

Electrical:

Medical Gas:

120 VOLT, SPECIAL OUTLET

N/A Misc Gas: N/A

Drops: 1

N/ANonMed Gas:

N/AMisc:

1:

2:

3:

4:

5:

6:

8:

9:

10:

11:

12:

Addl Outlets: N/A

Utilities 7: Drain

Size:

N/AUtility Len(FT):

Utility Len(FT): N/A Utility Len(FT): N/A

N/A

N/AUtility Len(FT):

N/AUtility Len(FT):

N/AUtility Len(FT):

N/AUtility Len(FT):

Utility Len(FT): N/A Utility Len(FT): N/A

Cat Code:

TULSA

VV April 24, 2025Date Prepared:

JSN: X2100A

VAProject Type:

Project Continent:Project Area:

Sub Trade Required: N/A

Elevator Available

Loading Dock Available

Origin: N/A

Installed By: GOVT

Origin:

3rd Party Field Survey Required:

N/A

N/A

Building Protection Req: N/A N/AVerified Equip Fit through all

Hallways/Doorways:

N/AWeight lbs:

Destination: N/A

Sub Trades:

Installation Date: N/A

Shop Drawings Required: N/A

Equip Cost Includes Installation:

3rd Party Install Cost:

No N/A

3rd Party Install Start Date: N/A 3rd Party Install End Date: N/A

3rd Party POC Name: N/A 3rd Party POC Cell Phone: N/A

3rd Party POC Email: N/A

Installation/Logistics

N/A

N/A

Destination:

3rd Party Vendor Name: N/A

N/ACalibration and Testing:

Installation Note:

Shop Drawings Date Received: N/A

1Qty:

Department, Room, Quantity

ULTRASOUND ROOM-1A124(1)

RADIOLOGY SERVICE (276)

File details come from the government source that posted it. Updated .