Trower_Ave_Paving_-_Bid_Set_Plans.pdf
PDF 4 MB Posted
- Solicitation number
- 2026-IFB - PC-057
- Issued by
- Napa County, California
About this file
This is a Bid Set Plans document prepared by the City of Napa, California for the Trower Avenue Paving Project extending from Linda Vista Avenue to Solano Avenue. The project involves grinding and overlay paving operations, curb and gutter replacement, sidewalk reconstruction, and pavement markings and striping along Trower Avenue. Key construction activities include grinding three inches of existing asphalt concrete and placing two inches of new HMA over pavement fabric and a one-inch HMA leveling course, with six-inch HMA plugs at marked digout locations. The project requires removal of existing curb, gutter, and adjacent asphalt concrete, construction of new curb and gutter per City Standard S-1A, removal and reconstruction of sidewalk per City Standard S-4, installation of curb ramps per City Standard S-9, and adjustment of all utility manholes, valves, and boxes to grade. Sealed bids are due by Thursday, December 10, 2026, at 3:00 pm through electronic submission via the procurement portal at https://procurement.opengov.com/portal/cityofnapa. The bid set plans are dated November 10, 2026, and prepared under the direction of registered professional engineer Tam Duong, RCE 54927.
The plans include detailed specifications for pavement sections, construction notes, signing and striping details with thermoplastic markings per California MUTCD standards, and quantities for various curb, gutter, sidewalk, and striping elements throughout the project corridor. General notes specify that contractors must protect existing facilities not called out for removal, trim tree branches prior to grinding and paving, refrain from placing "No Parking" barricades more than 72 hours prior to construction, and allow paving and concrete removal limits to be laid out by the contractor, verified by City Inspector, and potentially adjusted by the City Engineer. The document indicates this is a Bid Set marked "NOT FOR CONSTRUCTION," establishing it as preliminary planning documentation for the bidding process.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
9'
N56° 25' 46"E 435.44'
±6 2'
4'
5'
LI
N
DA
V
IS
TA
A V
EN
UE
LL
O
YD
D
RI
V
E
LAP CT
TROWER AVENUE
2 2
1+37, 7.06' L
1+80, 7.38' L
1+80, 12.38' L 4+12, 14.12' L
4+12, 17.77' L
4+71, 8.26' L
4+71, 13.24' L
1+37, 15.71' L
L=45.99', R=500.00' D=005°16'
L=692.48', R=3650.00'
D=010°52'
±128SF
±32LF
5'
4'
15'
±6
2'TROWER AVENUE
O
XF
O
RD
ST
RE
ET
FA
IR
FA
X
D
RI
V E
6+45, 30.07' L 6+84, 29.18' L
6+74, 14.35' L
6+74, 9.36' L 7+81, 8.28' L
7+96, 12.51' L
L=692.48', R=3650.00' D=010°52' L=692.48', R=3650.00'D=010°52'
GENERAL NOTES
1. THE PROPERTY LINES, UTILITY INFORMATION & THE AERIAL
IMAGE AS SHOWN ON THESE PLANS ARE APPROXIMATE &
FOR REFERENCE ONLY.
2. CONTRACTOR SHALL NOT PLACE "NO PARKING"
BARRICADES MORE THAN 72 HOURS PRIOR TO
CONSTRUCTION WORK.
3. EXISTING FACILITIES, CONCRETE, LANDSCAPING, &
UTILITIES NOT CALLED OUT TO BE REMOVED SHALL BE
PROTECTED IN-PLACE.
4. CONTRACTOR SHALL TRIM TREE BRANCHES PER PROJECT
SPECIFICATIONS PRIOR TO GRINDING & PAVING.
DIGOUT & HMA PLUG
LEGEND
(N) CONCRETE SURFACE
SAWCUT LINE
EXISTING RIGHT-OF-WAY
(APPROXIMATE LOCATION)
REMOVE (2) TREES - 30" & 40"
EXISTING MANHOLE SEWER
EXISTING MANHOLE TELEPHONE
EXISITNG MANHOLE STORM DRAIN
EXISTING WATER VALVE(E) ELECTRICAL LINE
(E) GAS LINE
(E) STORM DRAIN LINE
(E) SANITARY SEWER LINE
(E) WATER LINE
EXISTING MONUMENT
CONSTRUCTION NOTES
1 GRIND 3" & PLACE 2" HMA OVER PAVEMENT FABRIC & 1" HMA LEVELING
COURSE. AT MARKED DIGOUT LOCATIONS, OVER EXCAVATE & PLACE 6"
HMA PLUG. SEE DETAIL 1, SHT C-3.00.
2 GRIND & OVERLAY LIMITS SHALL BE AS SHOWN & FROM LIP OF GUTTER TO
LIP OF GUTTER. CONFORM WITH (E) PAVEMENT. SEE DETAIL 2, SHT C-3.00.
3 REMOVE (E) CURB, GUTTER & ADJACENT AC (MIN. 2-FT FROM LIP OF
GUTTER). CONSTRUCT NEW CURB & GUTTER PER CITY STD S-1A.
LF AS SHOWN.
4 REMOVE (E) SIDEWALK. CONSTRUCT NEW SIDEWALK PER CITY STD S-4.
SF AS SHOWN.
REMOVE (E) SIDEWALK, CURB, GUTTER & ADJACENT AC (MIN. 2-FT FROM
#SPECIFICATIONS PRIOR TO GRINDING & PAVING.
5. ALL EXISTING UTILITY MANHOLES, VALVES & BOXES SHALL
BE ADJUSTED TO GRADE WITHIN THE PAVING &
CONCRETE WORK LIMITS.
6. PAVING & CONCRETE REMOVAL LIMITS AND AC DIGOUT
SHALL BE LAID OUT BY CONTRACTOR, VERIFIED BY CITY
INSPECTOR & MAY BE ADJUSTED BY CITY ENGINEER.
7. WHERE NEW CONCRETE CONFORMS TO EXISTING
CONCRETE, PROVIDE CONCRETE CONNECTION PER CITY
STD S-4B.
DATE
PLANS PREPARED
UNDER THE DIRECTION OF
SHEETS:
DWG LOG #
DATE: NOVEMBER 10, 2026
S 26-024
TAM DUONG, RCE 54927
A B C D E F G H I J K L
DRAWN BY: LM
CHECKED BY: RC
OF 6 -
TROWER AVENUE PAVING
LINDA VISTA AVE TO SOLANO AVE
BYDATEDESCRIPTIONNO.
REVISIONS BID SET
NOT FOR CONSTRUCTION
RE
GI
ST
ER
ED
PROFESSI NOO AL ENGINEER
STAT
A
A
E O OF FC LI
IRN
M
TA
D
C I IV L
U
C 54927
ONG
11/10/26
M A
TC
H
LI
N
E
LO
W
ER
L
EF
T
M A
TC
H
LI
N
E
U
PP
ER
R
IG
HT
PAVING PLAN
2 C 2.00
M A
TC
H
LI
N
E
SH
EE
T C -2
.0
0' 20' 40'
SCALE: 1" = 20'
REFERENCE CONTROL POINTS TABLE
POINT # NORTHING
1880991.04
EASTING
6468561.07
ELEVATION
91.68
DESCRIPTION
FND MON NO TAG
15'
84'
±6 4'N56° 09' 47"E 1330.42'
5'
43' 8'
SO
LA
N O
A V
E
TROWER AVENUE
BRIARWOOD
STREET
5 5
19+04, 15.94' L
19+81, 12.11' L
20+65, 27.74' L
22+20, 22.32' L
22+62, 27.68' L
79'
7'
29'
N56° 09' 47"E 1330.42'
10'
±33 SF
8'
M A
HE
R
ST
TR
EE
T
RA
LE
IG
H
ST
RE
ET
TROWER AVENUE
14+24, 7.79' L
15+03, 15.04' L
16+26, 7.97' L
16+46, 8.97' R
16+75, 18.89' R
CONSTRUCTION NOTES
1 GRIND 3" & PLACE 2" HMA OVER PAVEMENT FABRIC & 1" HMA LEVELING
COURSE. AT MARKED DIGOUT LOCATIONS, OVER EXCAVATE & PLACE 6"
HMA PLUG. SEE DETAIL 1, SHT C-3.00.
2 GRIND & OVERLAY LIMITS SHALL BE AS SHOWN & FROM LIP OF GUTTER TO
LIP OF GUTTER. CONFORM WITH (E) PAVEMENT. SEE DETAIL 2, SHT C-3.00.
REMOVE (E) CURB, GUTTER & ADJACENT AC (MIN. 2-FT FROM LIP OF
4 REMOVE (E) SIDEWALK. CONSTRUCT NEW SIDEWALK PER CITY STD S-4.
SF AS SHOWN.
5 REMOVE (E) SIDEWALK, CURB, GUTTER & ADJACENT AC (MIN. 2-FT FROM
LIP OF GUTTER). CONSTRUCT "CASE C" CURB RAMP PER CITY STD S-9. FIELD
FIT TO EXISTING SITE CONDITIONS & VERIFY EXISTING ELEVATIONS &
DIMENSIONS PRIOR TO CONSTRUCTION. SIDEWALK SECTION SHALL BE PER
CITY STD. S-4 & CURB/GUTTER SECTION SHALL BE PER CITY STD. S-1A.
REPLACE REMOVED ADJACENT AC SECTION WITH 6" HMA PLUG.
DIGOUT & HMA PLUG
LEGEND
(N) CONCRETE SURFACE
SAWCUT LINE
EXISTING RIGHT-OF-WAY
(APPROXIMATE LOCATION)
REMOVE (2) TREES - 30" & 40"
EXISTING MANHOLE SEWER
EXISTING MANHOLE TELEPHONE
EXISITNG MANHOLE STORM DRAIN
EXISTING WATER VALVE(E) ELECTRICAL LINE
(E) GAS LINE
(E) STORM DRAIN LINE
(E) SANITARY SEWER LINE
(E) WATER LINE
EXISTING MONUMENT
GENERAL NOTES
1. THE PROPERTY LINES, UTILITY INFORMATION & THE AERIAL
IMAGE AS SHOWN ON THESE PLANS ARE APPROXIMATE &
FOR REFERENCE ONLY.
2. CONTRACTOR SHALL NOT PLACE "NO PARKING"
BARRICADES MORE THAN 72 HOURS PRIOR TO
CONSTRUCTION WORK.
3. EXISTING FACILITIES, CONCRETE, LANDSCAPING, &
UTILITIES NOT CALLED OUT TO BE REMOVED SHALL BE
PROTECTED IN-PLACE.
4. CONTRACTOR SHALL TRIM TREE BRANCHES PER PROJECT
SPECIFICATIONS PRIOR TO GRINDING & PAVING.
SPECIFICATIONS PRIOR TO GRINDING & PAVING.
5. ALL EXISTING UTILITY MANHOLES, VALVES & BOXES SHALL
BE ADJUSTED TO GRADE WITHIN THE PAVING &
CONCRETE WORK LIMITS.
6. PAVING & CONCRETE REMOVAL LIMITS AND AC DIGOUT
SHALL BE LAID OUT BY CONTRACTOR, VERIFIED BY CITY
INSPECTOR & MAY BE ADJUSTED BY CITY ENGINEER.
7. WHERE NEW CONCRETE CONFORMS TO EXISTING
CONCRETE, PROVIDE CONCRETE CONNECTION PER CITY
STD S-4B.
DATE
PLANS PREPARED
UNDER THE DIRECTION OF
SHEETS:
DWG LOG #
DATE: NOVEMBER 10, 2026
S 26-024
TAM DUONG, RCE 54927
A B C D E F G H I J K L
DRAWN BY: LM
CHECKED BY: RC
OF 6 -
TROWER AVENUE PAVING
LINDA VISTA AVE TO SOLANO AVE
BYDATEDESCRIPTIONNO.
REVISIONS BID SET
NOT FOR CONSTRUCTION
RE
GI
ST
ER
ED
PROFESSI NOO AL ENGINEER
STAT
A
A
E O OF FC LI
IRN
M
TA
D
C I IV L
U
C 54927
ONG
11/10/26
M A
TC
H
LI
N
E
LO
W
ER
L
EF
T
M A
TC
H
LI
N
E
U
PP
ER
R
IG
HT
PAVING PLAN
3 C 2.01
M A
TC
H
LI
N
E
SH
EE
T C -2
.0
0' 20' 40'
SCALE: 1" = 20'
DATE
PLANS PREPARED
UNDER THE DIRECTION OF
SHEETS:
DWG LOG #
DATE: NOVEMBER 10, 2026
S 26-024
TAM DUONG, RCE 54927
A B C D E F G H I J K L
DRAWN BY: LM
CHECKED BY: RC
OF 6 -
TROWER AVENUE PAVING
LINDA VISTA AVE TO SOLANO AVE
BYDATEDESCRIPTIONNO.
REVISIONS BID SET
NOT FOR CONSTRUCTION
RE
GI
ST
ER
ED
PROFESSI NOO AL ENGINEER
STAT
A
A
E O OF FC LI
IRN
M
TA
D
C I IV L
U
C 54927
ONG
11/10/26
DETAILS
4 C 3.00
(E) AB
COMPACTED SOIL
(E) AC LAYER
MORE THAN 3"
(E) AB VARIES
(E) AC
(N) PAVEMENT
FABRIC
(E) FG = (N) FG
PROVIDE A STRAIGHT LINE AT
THE CONFORM (NO JAGGED
EDGES). SAW CUT IF NECESSARY
ADD TACK COAT ALONG
ENTIRE EDGE AND TOP
SURFACE OF (E) AC PVMT
1 PAVEMENT SECTION
NOT TO SCALE
COMPACTED SOIL
2 TYPICAL SECTION CONFORM WITH (E) PAVEMENT
NOT TO SCALE
(E) AC PVMT
SECTION
PAVEMENT SECTION
PER PLAN
2" HMA TO MATCH (E)
1" THICK LAYER OF 3 8"
HMA LEVELING COURSE
6" HMA PLUG,
4" AGGREGATE,
SEE PLAN VIEW
FOR LOCATIONS
PAVEMENT SECTION.
TAC COAT BETWEEN
HMA LAYERS
3 CURB RAMP PAY LIMIT
NOT TO SCALE
CURB RAMP PAY LIMIT
CURB & GUTTER
RAMP RAMP
(E) AC LAYER
LESS THAN 3"
(E) AB VARIES
COMPACTED SOIL
(E) AC PVMT
SECTION
PAVEMENT SECTION
PER PLAN
PAVEMENT SECTION.
TAC COAT BETWEEN
HMA LAYERS
(E) FG = (N) FG
PROVIDE A STRAIGHT LINE AT
THE CONFORM (NO JAGGED
EDGES). SAW CUT IF NECESSARY
ADD TACK COAT ALONG
ENTIRE EDGE AND TOP
SURFACE OF (E) AC PVMT
TROWER AVENUE
LL
O
YD
D
RI
V
E
LA
P
C T
LI
N
D A
V
IS
TA
A
VE
N
UE
32 - 80± LF
27B - 75± LF
27B - 510± LF
32 - 98± LF 32 - 423± LF
39A - 216± LF
DB
±1 2'
±1 2'
6'
8'
8'
8' 6'
8'
±1 2'
2'
39 - 1020± LF 6'
2'8'
6'
39 - 150± LF
±1 2'
2'
8'
8'
8'
39A - 88± LF
8' 2'
27B HATCH - 102± LF
12' SPACING
39A - 284± LF
27B HATCH - 18± LF
12' SPACING
27B
27B HATCH - 21± LF
12' SPACING
39A - 136± LF 39A - 136± LF39A - 40± LF
22 - 48± LF
22 - 48± LF
22 - 48± LF
22 - 48± LF
DB
38 - 76± LF
27B - 62± LF
39A - 108± LF
39A - 108± LF
39 - 124± LF
22 - 122± LF
27B - 18± LF
39 - 18± LF
22 - 18± LF
38 - 18± LF
39A - 18± LF
FA
IR
FA
X
D
RI
V E
TROWER AVENUE
O
XF
O
RD
ST
RE
ET
38 - 80± LF
39A - 216± LF
DB
DB
32 - 136± LF
39A - 216± LF
27B - 258± LF
39 - 516± LF
8'
8'
6'
6'
6'
2'
8'
39A - 132± LF
8'
±1
8'
±1 2'
2'
8'
6'
'29 - 90± LF
39A - 112± LF
27B - 238± LF
39 - 632± LF
39A - 112± LF 39A - 40± LF
39A - 40± LF
27B
27B
27B HATCH 27B HATCH
27B HATCH - 63± LF
12' SPACING
39A - 40± LF
22 - 48± LF
22 - 83± LF
22 - 48± LF
REMOVE "NO
PARKING" SIGN
REPLACE WITH R81(CA)
REMOVE "NO
PARKING" SIGN
REPLACE WITH R81(CA)
REMOVE "NO
PARKING" SIGN
REPLACE WITH
R81(CA)
39 27B
27B HATCH
DB
DATE
PLANS PREPARED
UNDER THE DIRECTION OF
SHEETS:
DWG LOG #
DATE: NOVEMBER 10, 2026
S 26-024
TAM DUONG, RCE 54927
A B C D E F G H I J K L
DRAWN BY: LM
CHECKED BY: RC
OF 6 -
TROWER AVENUE PAVING
LINDA VISTA AVE TO SOLANO AVE
BYDATEDESCRIPTIONNO.
REVISIONS BID SET
NOT FOR CONSTRUCTION
RE
GI
ST
ER
ED
PROFESSI NOO AL ENGINEER
STAT
A
A
E O OF FC LI
IRN
M
TA
D
C I IV L
U
C 54927
ONG
11/10/26
M A
TC
H
LI
N
E
LO
W
ER
L
EF
T
M A
TC
H
LI
N
E
U
PP
ER
R
IG
HT
M A
TC
H
LI
N
E
SH
EE
T C
-4 .0
SIGNING & STRIPING PLAN
5 C 4.00
STRIPING NOTES
INSTALL "STOP" MARKING & STOP LINE
PER STOP APPROACH DETAIL.
LEGEND
39 - 186 ± LF
CA MUTCD DETAIL NUMBER
ESTIMATED QUANTITY
LADDER CROSSWALK - A24F
4'
10'
2' 1'
INSTALL PAVEMENT MARKINGS
WORDS PER CALTRANS A24D (TYP)
DOUBLE SIDED BLUE REFLECTOR (TYP)
INSTALL TYPE IV ARROW (TYP)
INSTALL "BIKE LANE
SYMBOL" AND BIKE
LANE ARROW
INSTALL GREEN
PAVEMENT
WHITE
GREEN
DETAIL 39A
4' x 5' to 8' GREEN
PAVEMENT
DIRECTION OF
TRAFFIC FLOW
WHITE
6'
6'
6'
15'
5' MIN
6' MAX
DETAIL 39A
WHEN NOT
AGAINST GUTTER
GENERAL NOTES
1. ALL STRIPING AND MARKINGS SHALL BE THERMOPLASTIC
AND PLACED PER CURRENT CA MUTCD STANDARDS.
2. CONTRACTOR SHALL CAT-TRACK A MINIMUM OF 2 DAYS
AFTER PAVING OPERATIONS. CONTRACTOR SHALL ALLOW
3 DAYS FOR ENGINEER REVIEW AND APPROVAL.
3. CAT-TRACK MUST APPROVED BY ENGINEER PRIOR TO FINAL
STRIPING.
DB
BASIC CROSSWALK - A24F
6' MIN1'
INSTALL WHITE "STOP" LETTERING
4'
8'
8'
INSTALL 1' WIDE WHITE STOP BAR
INSTALL 1' WHITE CROSSWALK BAR
C
EN
TERLIN
E
PER PLA
NINSTALL BASIC OR LADDER CROSSWALK
PER MARKING DETAILS.
0' 20' 40'
SCALE: 1" = 20'
YIELD MARKINGS-ROADWAY
24" 12"
YIELD MARKINGS-BIKE LANE
12" 6"
STOP APPROACH
PAVEMENT MARKINGS CROSSWALK
BR
IA
RW
O
O D
ST
RE
ET
TROWER AVENUE
32 - 256± LF
39 - 392± LF
37B - 135± LF
6'
6'
SO
LA
N O
A
VE
39A - 108± LF
39A - 108± LF
9A - 304± LF
39 - 202± LF
8'
6'
6'
±1
1'
38 - 96± LF
8'
8'
27B - 196± LF
27B HATCH - 45± LF
12' SPACING
39A - 40± LF 39A - 40± LF
2' 27B
39 39
22 - 155± LF
22 - 48± LF
DB
DB
RA
LE
IG
H
ST
RE
ET
M A
HE
R
ST
TR
EE
T
32 - 322± LF
39 - 306± LF
27B - 306± LF
39A - 216± LF
32 - 195± LF
39 - 109± LF
8'
8'
DB
TROWER AVENUE
39 - 65± LF
8' 6'
2'
8'
±1 1'
6'
2'8' 8' 6'
2'
6'
27B - 54± LF
39A - 40± LF 39A - 112± LF 39A - 112± LF
39A - 216± LF
±1 1'
6'
8'
39 - 921± LF
27B (HATCH) 71± LF
12' SPACING
27B
27B HATCH27B HATCH - 66± LF
12' SPACING
27B HATCH - 15± LF
12' SPACING
22 - 48± LF
22 - 48± LF
REMOVE "NO
PARKING" SIGN
REPLACE WITH R81(CA)
DB
DATE
PLANS PREPARED
UNDER THE DIRECTION OF
SHEETS:
DWG LOG #
DATE: NOVEMBER 10, 2026
S 26-024
TAM DUONG, RCE 54927
A B C D E F G H I J K L
DRAWN BY: LM
CHECKED BY: RC
OF 6 -
TROWER AVENUE PAVING
LINDA VISTA AVE TO SOLANO AVE
BYDATEDESCRIPTIONNO.
REVISIONS BID SET
NOT FOR CONSTRUCTION
RE
GI
ST
ER
ED
PROFESSI NOO AL ENGINEER
STAT
A
A
E O OF FC LI
IRN
M
TA
D
C I IV L
U
C 54927
ONG
11/10/26
M A
TC
H
LI
N
E
LO
W
ER
L
EF
T
M A
TC
H
LI
N
E
U
PP
ER
R
IG
HT
SIGNING & STRIPING PLAN
6 C 4.01
M A
TC
H
LI
N
E
SH
EE
T C -4
.0
STRIPING NOTES
INSTALL "STOP" MARKING & STOP LINE
PER STOP APPROACH DETAIL.
LEGEND
39 - 186 ± LF
CA MUTCD DETAIL NUMBER
ESTIMATED QUANTITY
INSTALL PAVEMENT MARKINGS
WORDS PER CALTRANS A24D (TYP)
DOUBLE SIDED BLUE REFLECTOR (TYP)
INSTALL TYPE IV ARROW A24A (TYP)
INSTALL "BIKE LANE
SYMBOL" AND BIKE
LANE ARROW
INSTALL GREEN
PAVEMENT
WHITE
GREEN
DETAIL 39A
4' x 5' to 8' GREEN
PAVEMENT
DIRECTION OF
TRAFFIC FLOW
WHITE
6' 6'
6'
5' MIN
6' MAX
DETAIL 39A
WHEN NOT
AGAINST GUTTER
GENERAL NOTES
1. ALL STRIPING AND MARKINGS SHALL BE THERMOPLASTIC
AND PLACED PER CURRENT CA MUTCD STANDARDS.
2. CONTRACTOR SHALL CAT-TRACK A MINIMUM OF 2 DAYS
AFTER PAVING OPERATIONS. CONTRACTOR SHALL
ALLOW 3 DAYS FOR ENGINEER REVIEW AND APPROVAL.
3. CAT-TRACK MUST APPROVED BY ENGINEER PRIOR TO
FINAL STRIPING.
DB
BASIC CROSSWALK - A24F
6' M
IN
1'
INSTALL BASIC OR LADDER CROSSWALK
PER MARKING DETAILS.
INSTALL TYPE VI ARROW A24A (TYP)
INSTALL RAILROAD CROSSING
SYMBOL - A24B (TYP)
INSTALL TYPE I ARROW A24A (TYP)
INSTALL TYPE VII ARROW A24A (TYP)
0' 20' 40'
SCALE: 1" = 20'
INSTALL WHITE "STOP" LETTERING
4'
8'
8'
INSTALL 1' WIDE WHITE STOP BAR
INSTALL 1' WHITE CROSSWALK BAR
STOP APPROACH
PAVEMENT MARKINGS CROSSWALK
C
EN
TERLIN
E
PER PLA
N
| Trower Ave Paving Bid Set |
| Sheets and Views |
| 01-G1-TrowerPaving-01 G1.00-Index & Cover |
| 02-03-C2-Paving-02-C2.00-Paving |
| 02-03-C2-Paving-03-C2.01-Paving |
| 04-C3-Details-06 C3.00-Details |
| 05-06-C4-Striping-05-C4.00-Striping |
| 05-06-C4-Striping-06-C4.01-Striping |