This is a specification sheet and ordering guide for the TransPort PT900, a portable ultrasonic flowmeter manufactured by Panametrics, which is the subject of a brand name exemption request by the Idaho Department of Water Resources. The TransPort PT900 is a clamp-on portable flow measurement device designed for temporary or spot flow rate measurements across various pipe sizes, materials, and fluid types. The system includes a clamping fixture with transducers, a flow transmitter with electronics, a tablet-based user interface, and a carrying case. The device supports pipe sizes from 0.5 to 24 inches in standard configurations, with optional capability up to 300 inches, and accommodates pipe wall thicknesses up to 3 inches. The system offers measurement capabilities including velocity, volume, mass, totalizer, and energy flow rate measurements with accuracy of 1 percent of reading for pipes 2 inches or greater in diameter and 2 percent for smaller pipes. The device operates across temperature ranges from -40 to 150 degrees Celsius in standard configurations, with optional extended ranges available. The tablet-based user interface operates on Android version 4.4 or greater or iOS version 11.0 or greater with Bluetooth or wired communication capability, and the system includes 8 gigabytes of datalogging storage with multi-language support in 15 languages.
The TransPort PT900 is available in multiple configurations including one-channel or two-channel systems with various power cord options for different geographic regions and transducer kit combinations to suit specific application requirements. Optional accessories include thickness gauges, energy measurement kits, extended transducer cables up to 100 feet, spare batteries, external chargers, and both soft and hard carrying cases. The specification sheet provides detailed ordering codes and example configuration strings for customized system procurement. The document indicates Bluetooth certification across 41 countries and regions, including the United States, and compliance with CE, ANSI/UL, and RoHS directives. No pricing information, contract term, or specific quantities are provided in the specification sheet. The Idaho Department of Water Resources' brand name exemption request allows the agency to procure this specific brand without competitive bidding if approved by the Department of Purchasing Administrator, with suppliers invited to submit supporting or contradictory information prior to the decision.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IDWR - Ultrasonic flow meter 4-29-2026.pdf | ||
| Flow Meter Justification Memo.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TransPort® PT900 PT900 portable ultrasonic flowmeter for liquids The TransPort PT900 is the latest generation of portable clamp-on flow meters from Panametrics line of ultrasonic meters. It capitalizes on the ruggedness and superior performance of its predecessor, the TransPort PT878, but delivers a whole new level of intuitive and us-er-friendly capability based on today’s technology.
PANA033DS Rev. 15
Datasheet
TransPort® PT900 Datasheet । PANAMETRICS
TransPort PT900 makes your job so much easier The PT900 has undergone the most involved voice of the user effort to date for Panametrics flow products.
Several years of learning about how people use portable flow meters and what they want and need while making flow rate measurements have influenced the PT900’s design. Panametrics validated this learning and modified the design ap-proach by sharing initial concepts and early prototypes with users. The result? The best portable flow meter needs to be versatile, easy to install, intuitive to use and capable of making reliable measurements even in the most difficult applications.
What’s new about the TransPort PT900?
The PT900 maintains the same high performance as the PT878, but features a total redesign of the flow transmitter, clamping fixture and user interface. Key improve-ments include a redesigned fixture and a streamlined user interface on an Android tablet.
PT900 is designed to improve the user experience and deliver a measurement that inspires a high level of user confidence. All users, regardless of experience level with the meter, will be able to:
| • | Install the clamping fixture with minimal confusion or repositioning |
| • | Connect the transmitter and transducer cables correctly |
| • | Turn on the tablet and pair it via Bluetooth® with the transmitter |
| • | Start taking measurements within minutes |
Product details The TransPort PT900 system includes:
| • | Clamping fixture with transducers |
| • | Flow transmitter (the electronics) |
| • | Carrying case |
| • | Accessories |
Available options include:
| • | Tablet |
| • | Rechargeable battery pack or spare battery |
| • | Waygate Technologies DM5E thickness gauge |
| • | Energy measurement kit |
Advantages
• A wide selection of transducers suitable for most applications
• Wireless (Bluetooth®) or wired communication from tablet transmitter
• Easy programming with bright touch screen and multiple-language user interface
• Fast-responding, high-accuracy transmitter with green/red light health indication and 8 GB of datalogging storage
• Velocity, volume, mass, totalizer and energy flow rate measurements
• Easy-to-install clamping fixture
Applications
• Suitable for most pipe sizes and materials, both lined and unlined
• Suitable for virtually every industry that requires temporary or spot flow rate measurement
• Suitable for many fluids, including potable water, wastewater, cooling and heating water, ultrapure water and other liquids such as water/glycol solutions, crude oil, refined hydrocarbons, chemicals and beverages
Clamping fixture, transducers and transmitter mounted on pipe
Fluid types Liquids: Acoustically conductive fluids, including most clean liquids and many liquids with small amounts of entrained solids or gas bubbles
Flow measurement
Patented Correlation Transit-Time™ mode
| Pipe sizes • | Standard: 0.5 to 24 in. (15 to 600 mm) |
| • | Optional: up to 300 in. (7500 mm) available |
upon request
Pipe wall thickness
Up to 3 in. (76.2 mm)
Pipe material All metals and most plastics Consult Panametrics for concrete, composite materials and highly corroded or lined pipes.
Accuracy • ±1% of reading (2 in./50 mm or greater pipe sizes)
• ±2% of reading (0.5 in./15 mm to <2 in./50 mm pipe sizes)
Installation assumes a fully developed, symmetrical flow profile (typically 10 pipe diameters upstream and 5 pipe diameters downstream of straight pipe run).
Final installation accuracy is a function of multiple factors including fluid, temperature range, pipe centricity among other factors.
Pipe layouts with obstructions (bends, tees, valves, etc.) will result in different levels of meter reading bias. Dual-path readings in opposite planes can be used to indicate the presence of bias (assymetrical flow profile).
Reasonable accuracy (±5% of reading) could be maintained in non-ideal conditions down to approximately 5D upstream and 1D downstream with accurate inputs, acceptible diafgnostic parameters, and dual plane readings in close agreement with a simple flow disturbance. Other piping layout resulting in a non-fully developed flow profile will deliver different biases. Computation fluid dynamics (CFD) corrections can also be used in non-ideal conditions.
Repeatability ±0.2% of reading
Range (Bidirectional)
0.1 to 40 ft/s (0.03 to 12.19 m/s)
Response time Up to 2 Hz
Measurement Parameters
Velocity, volume, mass, energy, total flow
Channels 1 or 2 channels
Enclosure IP65 rating
| Specifications • | Weight: 3 lb (1.4 kg) |
| • | Size (h x w x md): 7.9 x 4.3 x 1.5 in |
(200x109 x 38 mm)
• Mounting: Soft strap around pipe or magnetic clamp
Analog inputs 4-20 mA (qty 2)
Analog output 4-20 mA
Digital output Pulse (Totalizer), Frequency, Alarm (qty 1)
Digital communication
| • | Bluetooth® wireless* |
| • | Modbus via RS485 port |
| • | Micro-USB port |
*Bluetooth certification in specific countries or regions. See page #6 for list of Bluetooth locations.
Battery • Type: Lithium ion (high-energy, rechargeable) Life (continuous operation):
18-20 hours
• Life (power saver mode): >4 days Charger:
100 to 240 VAC (50/60/Hz)
• Charging time: Up to 3 hours (from 0% to 100%)
Operating temperature
| • | Charge: 0 to 45°C (32 to 113°F) |
| • | Discharge: -20 to 55°C (-4 to 131°F) |
Storage temperature
-20 to 60°C (-4 to 140°F)
Electronics classifications
• CE (EMC Directive) IEC 61326-1:2013, IEC 61326-2-3:2013, LVD 2006/95/EC, EN
61010-1 2010
• ANSI/UL STD. 61010-1, CAN/CSA STD. C22.2 NO.
61010-1
| • | WEEE compliant (Directive 2012/19/EU) |
| • | RoHS compliant (Directive 2011/65/EU) |
Operation and performance Flow transmitter
Technical Specifications
Transmitter electrical connections
Display Requires a tablet. Android operating system (version 4.4 or greater) or iOS operating system (iOS version 11.0 or greater, BLE 4.0 or greater, capacity of 16GB and greater).
Dimensions • 7 in. Tablet: 7.75 x 4.75 x 0.75 in.
(196 x 120 x 19 mm) typical
• 8 in. Tablet: 8.75 x 6.00 x 0.75 in.
(222 x 152 x 19 mm) typical
Battery life >12 hours of continuous use, function of final settings of tablet
Battery charger 100 to 250 VAC (50/60 Hz)
Communication with flow transmitter
Bluetooth® or wired (wired for Android only)
Intuitive, swipe screen interface
| • | Colorful, icon-driven design |
| • | Tutorial-style programming |
| • | Site parameter presets |
| • | Multiple display options |
| • | Extensive online help |
Languages English, Arabic, Chinese (Simplified), Dutch, French, German, Italian, Japanese, Korean, Por-tuguese, Russian, Spanish, Swedish, Turkish
Installing the
PT900 APP
Obtain the PT900 APP:
• File provided on SD card
(Android)
• Free download from
Google Play (Android)
• Free download from
App Store (Apple)
• Free download from
Panametrics website (Android)
User interface Software application (PT900 APP)
PT900 APP tablet display Measurement Screens
Temperature range*
| • | Standard: -40 to 302°F (-40 to 150°C) |
| • | Optional: -328 to 752°F (-200 to 400°C) |
*See individual transducer model specifications for exact temperature range.
Mounting • New PT clamping fixture for pipes ≥2 in.
(50 mm)
• CF-LP clamping fixture for 1/2 in. (15 mm) to 2 in. (50 mm) pipes
PT900
transducer cables
• Standard length: 25 ft (8 m) of RG316 coaxial cable (P/N: 101N0321)
• Maximum length: 100 ft (30 m) of RG316 coaxial cable (P/N: PT9-EXT)
• Temperature range: -40° to 302°F (-40° to 150°C)
Clamp-on transducers
The optional energy measurement kit calculates energy flow rate and totalized energy.
• Temperature transmitter: loop-powered, 4-wire PT1000 surface-mount RTDs, NIST-certified
| • | Accuracy: ± 0.12°C ( ± 0.22°F) of reading |
| • | Range: 0 to 149°C (32 to 300°F) standard |
Waygate Technologies DM5E thickness gauge
| • | Range from 1 to 200 mm (0.040 to 8”) |
| • | High-resolution graphical LCD |
| • | IP54 weatherproof rating |
| • | 5MHz probe, -20 to 70°C |
| • | Standard two AA batteries |
Spare battery • Battery pack: Lithium ion, high-energy, rechargeable
• Battery charger: 100 to 240 VAC (50/60/Hz)
Cable adapter TNC to BNC or UTXDR connectors
Energy measurement kit
Cases • Soft nylon carry bag with strap and dedicated equipment dividers (standard)
• Hard case with wheels and dedicated equipment compartments (optional)
| Cables • | Input and output cables: analog and digital |
| • | Cable adapters: TNC to BNC or UTDR |
connectors
Accessories
Tablet Android IP68 Tablet
Options
Clamp-on fixture with CRR transducers
Standard soft shell carrying case
Optional hard shell carrying case
How to order the Transport PT900 system PT9-SYS Base Model Number
Code 1C 2C
1CW
2CW
Channels One Channel PT900 (Bluetooth or Direct Wired - Android, Bluetooth - iOS) Two Channel PT900 (Bluetooth or Direct Wired - Android, Bluetooth - iOS) One Channel PT900 (Direct Wired Only - Android) Two Channel PT900 (Direct Wired Only - Android)
Code
Code Power Cord 110/120 VAC (NEMA 5-15P - typical North America) 230 VAC (Schuko CEE 7/7 2 poles and earth - typical European) 230 VAC (BS 1363 A, 3pin square - typical United Kingdom) 230V AC (GB 15934-2008 - typical Asia)
110VAC (JIS8308/3 JP)
230VAC (AS3112 - AUS/NZ)
Code A B C D E F G I J K L M N P
Transducer & Fixture Kit #1 None -40 to 150°C (-40 to 302°F), 50 mm to 600 mm (2” to 24”) typical pipe size -40 to 230°C (-40 to 446°F), 15 mm to 50 mm (0.5” to 2”) pipe size -40 to 150°C (-40 to 302°F), 150 mm (6”) or larger pipe size -40 to 210°C (-40 to 410°F) applications, 50 mm to 600 mm (2” to 24”) pipe size Combination of A and C Combination of A, B and C Combination of A and B -40 to 150°C (-40 to 302°F), 15 mm to 50 mm (0.5” to 2”) pipe size Combination of A and I Combination of A, C and I Combination of D and I -40 to 150oC (-40 to 302oF), 50mm to 150mm (2” to 6”) Combination of B and M Combination of A, B, and M
Code A B C D I
M
Transducer & Fixture Kit #2 None -40 to 150°C (-40 to 302°F), 50 mm to 600 mm (2” to 24”) typical pipe size -40 to 230°C (-40 to 446°F), 15 mm to 50 mm (0.5” to 2”) pipe size -40 to 150°C (-40 to 302°F), 150 mm (6”) or larger pipe size -40 to 210°C (-40 to 410°F) applications, 50 mm to 600 mm (2” to 24”) pipe size -40 to 150°C (-40 to 302°F), 15 mm to 50 mm (0.5” to 2”) pipe size -40 to 150°C (-40 to 302°F), 50mm to 150mm (2” to 6”)
Code
SC
HC
Carrying Case Standard soft shell carrying case; ideal for everyday user Optional hard shell carrying case; ideal for shipping and transportation
Code
TG2
E C48
2C48
AIO
DIO
BAT
CHG
EXT
EXT2
WUSB2
System Options Pipe wall thickness gauge (DM5E) Energy kit with matched pair PT1000 surface mounted RTDs with transmitter Additional chain assembly for mounting on pipe sizes up to 1200 mm (48”) Two additional chain assemblies for mounting on pipe sizes up to 1200 mm (48”) Analog input and output cable Digital and discrete input and output cable Spare rechargable battery External battery charger for spare battery Pair 100 ft extension cables (C-RR transducers) Two pairs of 100 ft extension cables (C-RR transducers) Cable for wired USB tablet connection
PT9-SYS 1C 2 A A HC TG (Example Configuration String)
Bluetooth Certification (PT900) Argentina, Brazil , Canada , Chile , China, Colombia Costa Rica , Egypt, European Union, Hong Kong , India , Indonesia, Japan , Malaysia, Mexico , Monaco, New Zealand, Nigeria , Oman, Pakistan, Peru, Philippines , Qatar, State of , Saudi Ara-bia , Singapore, South Africa, South Korea, Taiwan, Thailand, Turkey , Ukraine, United Arab Emirates, United States, Vietnam panametrics.com Copyright 2025 by Panametrics LLC. All rights reserved.
PANA033DS_R15 (06/2025)
Join the conversation and follow us on LinkedIn linkedin.com/company/panametricscompany
PT9-SYSI Base Model Number
Code 1C 2C
1CW
2CW
Channels One Channel PT900 (Bluetooth or Direct Wired - Android, Bluetooth - iOS) Two Channel PT900 (Bluetooth or Direct Wired - Android, Bluetooth - iOS) One Channel PT900 (Direct Wired Only - Android) Two Channel PT900 (Direct Wired Only - Android)
Code
Code Power Cord 110/120 VAC (NEMA 5-15P - typical North America) 230 VAC (Schuko CEE 7/7 2 poles and earth - typical European) 230 VAC (BS 1363 A, 3pin square - typical United Kingdom) 230V AC (GB 15934-2008 - typical Asia)
110VAC (JIS8308/3 JP)
230VAC (AS3112 - AUS/NZ)
Code A B C D E F G H I J K L
Transducer & Fixture Kit #1 None -40 to 150°C (-40 to 302°F), 50 mm to 600 mm (2” to 24”) typical pipe size (C-RS) -40 to 230°C (-40 to 446°F), 15 mm to 50 mm (0.5” to 2”) pipe size -40 to 150°C (-40 to 302°F), 150 mm (6”) or larger pipe size (C-RS) -40 to 210°C (-40 to 410°F) applications, 50 mm to 600 mm (2” to 24”) pipe size (C-RR) Combination of A and C Combination of A, B and C Combination of A and B Combination of B and D -40 to 150°C (-40 to 302°F), 15 mm to 50 mm (0.5” to 2”) pipe size Combination of A and I Combination of A, C and I Combination of D and I
Code A B C D I
Transducer & Fixture Kit #2 None -40 to 150°C (-40 to 302°F), 50 mm to 600 mm (2” to 24”) typical pipe size (C-RS) -40 to 230°C (-40 to 446°F), 15 mm to 50 mm (0.5” to 2”) pipe size -40 to 150°C (-40 to 302°F), 150 mm (6”) or larger pipe size (C-RS) -40 to 210°C (-40 to 410°F) applications, 50 mm to 600 mm (2” to 24”) pipe size (C-RR) -40 to 150°C (-40 to 302°F), 15 mm to 50 mm (0.5” to 2”) pipe size
Code
SC
HC
Carrying Case Standard soft shell carrying case; ideal for everyday user Optional hard shell carrying case; ideal for shipping and transportation
Code
TG2
E C48
2C48
AIO
DIO
BAT
CHG
EXT
EXT2
WUSB2
System Options Pipe wall thickness gauge (DM5E) Energy kit with matched pair PT1000 surface mounted RTDs with transmitter Additional chain assembly for mounting on pipe sizes up to 1200 mm (48”) Two additional chain assemblies for mounting on pipe sizes up to 1200 mm (48”) Analog input and output cable Digital and discrete input and output cable Spare rechargable battery External battery charger for spare battery Pair 100 ft extension cables (C-RR transducers) Two pairs of 100 ft extension cables (C-RR transducers) Cable for wired USB tablet connection
PT9-SYSI 1C 2 A A HC TG (Example Configuration String)
How to order the Transport PT900 system (PT9-SYSI)
File details come from the government source that posted it. Updated .