Town of Fraser - Historic Church Kitchen Renovation - 100% CD Drawings - 2023-0428.pdf
PDF 12 MB Posted
- Attached to
- Historic Church Kitchen Renovation
- Solicitation number
- 2025 - Historic Church Kitchen Renovation
- Issued by
- Grand County, Colorado
About this file
The document is a comprehensive set of construction documents for the Town of Fraser's Historic Church Kitchen Renovation project located at 107 East Eisenhower Drive in Fraser, Colorado. Prepared by DAO Architecture with engineering support from JVA, DMA Engineering, and Kazin and Associates, the project involves a renovation of a former church and community center. The scope includes partial demolition of interior walls and fixtures, installation of new walls for a kitchen and restrooms, and updates to mechanical, plumbing, and electrical systems. The project documents are dated April 28, 2023, with the drawing set (DAO No.: 2022-018) containing detailed architectural, structural, mechanical, plumbing, and electrical plans.
The renovation will transform approximately 3,582 square feet of space, focusing on updating the kitchen, restrooms, and associated areas to continue supporting community activities. The project is designed to meet 2021 International Building Code requirements, with specific attention to occupancy classifications (A-3 Assembly and B Business spaces), fire protection, means of egress, and accessibility standards. The construction documents specify use of materials like luxury vinyl tile flooring, painted gypsum walls, wood cabinetry from Thomasville Artisan Cabinetry, and solid surface countertops. The renovation includes new appliances, fixtures, and modernization of building systems while maintaining the building's historical character and community function.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING INDEX
DAO No.: 2022-018
OWNER:
TOWN OF FRASER
153 FRASER AVENUE
FRASER, CO 80442
CONTACT: MONICA KOPF/MICHAEL BRACK
PHONE #: 970.531.1943/970.726.5491
ARCHITECT:
DAO ARCHITECTURE
7230 MEADE ST
WESTMINSTER, CO 80030
CONTACT: DAN ORECCHIO
PHONE #: 720.273.0431
STRUCTURAL ENGINEERS:
JVA, INCORPORATED
47 COOPER CREEK WAY, SUITE 328
WINTER PARK, CO 80482
JEFFREY BEAUREGARD
PHONE #: 303.565.4964
MECHANICAL AND PLUMBING ENGINEERS:
DMA ENGINEERING
1211 AVERY ST. SUITE 101
GOLDEN, CO 80403
CONTACT: STEVEN FORRESTER
PHONE #: 303.732.5559 EXT. 1
ELECTRICAL:
KAZIN AND ASSOCITES, INC
9364 TEDDY LANE, SUITE 101
LONE TREE, CO 80124
CONTACT: BRYAN KAZIN
PHONE #: 720.489.1609
GENERAL CONTRACTOR:
7230 Meade St.
Westminster, CO 80030
Phone: 720.273.0431
Email: dan@daoarch.com
Web: www.daoarch.com
Historic Church Kitchen Renovation
DAO No.:
C :\U se rs
\D ev in \D oc um en ts
\T ow n of
F ra se r
H is to ric C hu rc h
C on st ru ct io n D oc um en ts
_2 1C od es
R ev it de vi n9
H F
G J.
rv t
4/
/2
7:
:2
A
M
Cover
Town of Fraser
107 East Eisenhower Drive, Fraser, CO 80442
April 28, 2023 Construction Documents
Town of Fraser
107 East Eisenhower Drive, Fraser, CO 80442
April 28, 2023
Historic Church Kitchen
Renovation
2022-018
GENERAL
Cover Cover Sheet
G0.0 Standard Symbols, Abbreviations & General Notes
G0.1 Building Code Data
ARCHITECTURE
AD1.0 First Floor Demolition Plan
AD1.1 First Floor Demolition RCP
A1.0 First Floor Plan
A1.1 First Floor RCP
A6.0 Interior Elevations/Casework Sections/Toilet Accessories
A6.1 Typical Details/Door Schedule/Door Frames
A9.0 Finish Plan
STRUCTURAL
S0.0 General Notes
S1.0 Attic Level and Roof Framing Plans & Sections
CONSTRUCTION DOCUMENTS
South Elevation
MECHANICAL
M0.1 Mechanical Cover Sheet
M0.2 Schedules
M0.3 Thermal Zones
M0.4 Air Side Zones
M1.0 Mechanical Plan
M2.0 Equipment Laout Plan
M3.0 Details
PLUMBING
P0.1 Plumbing Cover Sheet
P0.2 Schedules
P1.0 Plumbing-Waste and Vent Plan
P2.0 Details
ELECTRICAL
E0.1 Electrical Specifications & Legend
E0.2 One-Line Diagram & Schedules
E0.3 Comcheck
E1.1 Power Plan and Lighting Plan
GENERAL NOTES
THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS
SHOWN ON PLANS PRIOR TO COMMENCEMENT OF THE WORK . IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO COORDINATE INSTALLATION OF NEW WORK WITHIN
THESE EXISTING CONDITIONS. ANY DEVIATIONS IN EXISTING CONDITIONS OR DIMENSIONS
INDICATED SHALL BE COORDINATED WITH THE ARCHITECT AND OWNER IN ORDER TO MODIFY
PLANS ACCORDINGLY .
ALL DISCIPLINES SHALL BE RESPONSIBLE FOR THEIR SCOPE OF WORK . THIS WORK IS TO BE
SCHEDULED AND COMPLETED WITH THE GENERAL CONTRACTOR'S FULL KNOWLEDGE.
THE PROJECT STAGING AREA / CONSTRUCTION ACTIVITIES SHALL NOT CAUSE THE
OBSTRUCTION OF PATHS OF EGRESS INSIDE THE BUILDING, BLOCK EXIT DISCHARGE FROM
THE BUILDING, OR IMPEDE EMERGENCY VEHICLE ACCESS TO THE BUILDING. CORRIDORS MAY
NOT BE USED AS STAGING AREAS OR AS AREAS FOR DEBRIS COLLECTION.
THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE DETECTION OR REMOVAL OF ANY
HAZARDOUS MATERIALS, INCLUDING, BUT NOT LIMITED TO, ASBESTOS IN ANY FORM. PARTIES
RESPONSIBLE FOR DEMOLITION SHALL NOTIFY THE OWNER IMMEDIATELY OF ANY
SUSPECTED MATERIALS.
1.
2.
3.
4.
MATERIALS SYMBOLS
EARTH
NON-COMPACTED
EARTH
COMPACT/FILL
GRAVEL/POROUS
FILL
CONCRETE PRECAST CONCRETE SAND/MORTAR/PLASTER
ALUMINUM BRASS/BRONZE STEEL
CONCRETE
BLOCK
COMMON/FACE
BLOCK
FIRE BRICK
BLUESTONE/SLATE/
SOAPSTONE/FLAGGING
LIMESTONE RUBBLE
FINISH ROUGH SHIM
GLASS STRUCTURAL GLASS BLOCK
BATT/LOOSE FILL RIGID SPRAY/FOAM
ACOUSTICAL TILE CARPET AND PAD CERAMIC TILE
TECTUM
CAST-IN-PLACE
CONCRETE
CONCRETE
MASONRY
METAL STUD
ELEVATION INDICATIONS
BRICK CERAMIC/
PORCELAIN TILE
CONCRETE/
PLASTER/GPDW
SHEET METAL SHINGLES/SIDING
PARTITION INDICATIONS
FINISHES
INSULATION
GLASS
WOOD
STONE
MASONRY
METAL
CONCRETE
EARTHWORKS
STRUCTURAL
FACING TILE
PLYWOOD
GYPSUM
WALLBOARD
WOOD STUD
CONCRETE MASONRY UNIT
REFERENCE SYMBOLS
No.
Sht.
DETAIL OR SECTION NUMBER
SHEET ON WHICH IT IS FOUND
SECTION REFERENCE
DETAIL REFERENCE
WALL SECTION REFERENCE
BUILDING SECTION REFERENCE
ROOM
NAME
101101
1t
1i
Level 100'-0"
1A101
No.
ELEVATION REFERENCE
ROOM IDENTIFIER
WINDOW/OPENING IDENTIFIER
DOOR/OPENING IDENTIFIER
EXISTING GRID LINE
ELEVATION REFERENCE
WALL TYPE REFERENCE
MATCH LINE
DEMOLITION INDICATOR
REVISION INDICATOR
A1.0
SIM
No.
Sht.
No.
Sht.
No.
Sht.
No.
Sht.
Sht.
STANDARD ABBREVIATIONS
A/E
AB
ABBR
ABV
AC
ACID RES
ACOUS
ACOUS INSUL
ACOUS PNL
ACOUS PLAS
ACOUS TILE
ACT
AD
ADC
ADDL
ADDM
ADJ
ADJC
AF
AFF
AFG
AFS
AGGR
AHR
AHU
ALD
ALM
ALT
ALUM
AMB
AMPL
AMT
ANN
ANOD
ANT
AP
APPX
ARCH
ASB
ASC
ASPH
ASYM
AV
AVE
AWC
AWP
B&B
BAF
BAL
BB
BC
BD
BEV
BF
BFF
BFP
BITUM
BJT
BL
BLDG
BLK
BLKG
BLKHD
BLST
BM
BO
BOC
BOW
BP
BRCG
BRDG JST
BRG
BRG PL
BRK
BRKT
BRS
BRZ
BS
BSMT
BTM
BUR
BW
BOW
C/C C&G
CAB
CARP
CAV
CB
CCTV
CEM
CEM PLAS
CER
CER TILE
C FLG
CH BD
CG
CHAN
CHFR
CHK
CI
CIP
CIR
CJ
CL
CLG
CLG DIFF
CLG HT
CLL
CLOS
CLR
CLSR
CMPST
CMU
CNR
CNTR
CO
COL
COMM
COMPL
CONC
CONC FL
CONF
ARCHITECT/ENGINEER
ANCHOR BOLT
ABBREVIATE
ABOVE
AIR CONDITIONING
ACID RESISTANT
ACOUSTICAL
ACOUSTICAL INSULATION
ACOUSTICAL PANEL
ACOUSTICAL PLASTER
ACOUSTICAL TILE
ACTUAL
AREA DRAIN
AUTOMATIC DOOR CLOSER
ADDITIONAL
ADDENDUM
ADJUSTABLE
ADJACENT
ACCESS FLOOR
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ABOVE FINISHED SLAB
AGGREGATE
ANCHOR
AIR HANDLING UNIT
ALUMINUM DOOR
ALARM
ALTERNATE
ALUMINUM
AMBIENT
AMPLIFIER
AMOUNT
ANNUNCIATOR
ANODIZED
ANTENNA
ACCESS PANEL
APPENDIX
ARCHITECT(URAL)
ASBESTOS
ABOVE SUSPENDED CEILING
ASPHALT
ASYMMETRICAL
AUDIO VISUAL
AVENUE
ACOUSTICAL WALL COVERING
ACOUSTICAL WALL PANEL
BALLED AND BURLAPPED
BAFFLE
BALANCE
BULLETIN BOARD
BOTTOM OF CURB
BOARD
BEVEL
BOTH FACES
BELOW FINISH FLOOR
BACKFLOW PREVENTER
BITUMINOUS
BED JOINT
BASE LINE
BUILDING
BLOCK
BLOCKING
BULKHEAD
BALLAST
BEAM
BOTTOM OF
BACK OF CURB
BOTTOM OF WALL
BASE PLATE
BRACING
BRIDGING JOIST
BEARING
BEARING PLATE
BRICK
BRACKET
BRASS
BRONZE
BOTH SIDES
BASEMENT
BOTTOM
BUILT-UP ROOF
BOTH WAYS
BOTTOM OF WALL
CENTER TO CENTER
CURB AND GUTTER
CABINET
CARPET
CAVITY
CATCH BASIN
CLOSED CIRCUIT TELEVISION
CEMENT
CEMENT PLASTER
CERAMIC
CERAMIC TILE
COUNTER FLASHING
CHALKBOARD
CORNER GUARD
CHANNEL
CHAMFER
CHECK
CAST IRON
CAST IN PLACE
CIRCLE
CONTROL JOINT
CENTER LINE
CEILING
CEILING DIFFUSER
CEILING HEIGHT
CONTRACT LIMIT LINE
CLOSET
CLEAR
CLOSURE
COMPOSITE
CONCRETE MASONRY UNIT
CORNER
COUNTER
CLEANOUT
COLUMN
COMMERCIAL
COMPLETE
CONCRETE
CONCRETE FLOOR
CONFERENCE
CONN
CONSTR
CONT
CONTR
COORD
CORR
COV PL
CPRS
CPT
CRCMF
CRS
CSG
CSK
CSMT
CSWK
CT
C TV
CUB
CUR
CW
DBL GLZ
DEPT
DET
DF
DF
DFR
DH
DIA
DIM
DIST
DIV
DIW
DJ
DL
DMPF
DN
DO
DR
DR CLSR
DS
DST
DT
DUPL
DVTL
DW
DWG
DWL
DWR
DWTR
E
EA
EF
EJ
EL
ELEC
ELEV
EMER
EMER SHR
ENAM
ENCL
ENGR
ENTR
EO
EP
EPS
EPX
EQL SP
EQ
EQUIP
EQUIV
ERECT
ESCAL
ESMT
EST
EW
EXC
EXG
EXH HD
EXH FN
EXP
EXSP
EXST
EXST GR
EXT
EXTN
EIFS
F BRK
F/F
FBD
FC
FD
FDN
FEC
FF
FFE
FGL
FIN GR
FIN FL
FIN
FL
FLDG
FLG
FLR
FLR SK
FLR PL
FLR FIN
FLT GL
FLOUR
FOC
FOM
FOS
FPL
FPRF
FRM
FRNT
FS
FSP
FSTNR
FTG
FURR
FUT
FXTR
GA
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
COORDINATE
CORRIDOR
COVER PLATE
COMPRESSIBLE
CARPET
CIRCUMFERENCE
COLD ROLLED STEEL
CASING
COUNTERSUNK
CASEMENT
CASEWORK
CERAMIC TILE
CABLE TELEVISION
CUBICLE
CURRENT
COLD WATER
DOUBLE GLAZING
DEPARTMENT
DETAIL
DRINKING FOUNTAIN
DRAPERY FABRIC
DOOR FRAME
DOUBLE HUNG
DIAMETER
DIMENSION
DISTANCE
DIVIDER
DEIONIZED WATER
DOUBLE JOIST
DRAPERY LINER
DAMPPROOFING
DOWN
DITTO
DOOR
DOOR CLOSURE
DOWNSPOUT
DOOR STOP
DRAIN TILE
DUPLICATE
DOVETAIL
DISHWASHER
DRAWING
DOWEL
DRAWER
DUMBWAITER
EAST
EACH
EACH FACE
EXPANSION JOINT
ELEVATION
ELECTRICAL
ELEVATOR
EMERGENCY
EMERGENCY SHOWER
ENAMEL
ENCLOSURE
ENGINEER
ENTRANCE
ELECTRICAL OUTLET
ELECTRICAL PANEL
EXPANDED POLYSTYRENE
EPOXY FLOOR
EQUALLY SPACED
EQUAL
EQUIPMENT
EQUIVALENT
ERECTION
ESCALATOR
EASEMENT
ESTIMATE
EACH WAY
EXCAVATE
EXISTING
EXHAUST HOOD
EXHAUST FAN
EXPANSION
EXPOSED
EXISTING
EXISTING GRADE
EXTERIOR
EXTENSION
EXTERIOR INSULATION & FINISH SYSTEM
FIRE BRICK
FACE TO FACE
FIBERBOARD
FIRE COATED
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER CABINET
FACTORY FINISH
FINISH FLOOR ELEVATION
FIBERGLASS
FINISH GRADE
FINISH FLOOR
FINISH
FLOWLINE
FOLDING
FLANGE
FLOOR
FLOOR SINK
FLOOR PLATE
FLOOR FINISH
FLOAT GLASS
FLUORESCENT
FACE OF CONCRETE
FACE OF MASONRY
FACE OF STUD
FIREPLACE
FIREPROOFING
FRAME
FRONT
FULL SIZE
FIRE STANDPIPE
FASTENER
FOOTING
FURRING
FUTURE
FIXTURE
GYPSUM ASSOCIATION
GALV
GB
GDRL
GENL
GENL CONTR
GFI
GL
GL BLK
GLU LAM
GLZ
GLZ CMU
GND
GPDW
GR BM
GR
GRTG
GUT
GYP
GYP PLAS
H
H&CW
HB
HC
HC
HCMU
HD
HDJT
HDBD
HDR
HDWD
HGT
HLB
HM
HMD
HMF
HNDRL
HO
HORIZ
HR
HS
HSB
HTG
HVAC
HW
HYD
ID
IF
INCAND
INL
INSTL
INSUL
INTR
INV
INV EL
JAN
JC
JST
JT
KB
KO
KOP
KPL
KWY
L
LAB
LAT
LAV
LB
LBR
LCMU
LD BRG
LDG
LF
LG
LH
LHR
LIN
LIQ
LKR
LKR RM
LL
LNTL
LOC
LONG
LRG
LS
LT
LT WT
LTG
LVL
LVR
LW PLAS
LWC
M
MAINT
MARB
MAS
MATL
MAX
MB
MBR
MC
MDF
MDO
ME
ME
MECH
MED
MEMB
MEZZ
MFG
MFR
MH
MIL
MIN
MIR
MISC
MK
MKRBD
ML
MLC
MLDG
MLWK
GALVANIZED
GRAB BAR
GUARD RAIL
GENERAL
GENERAL CONTRACTOR
GROUND FAULT INTERRUPTER
GLASS
GLASS BLOCK
GLUE LAMINATED
GLAZING
GLAZED CONCRETE MASONRY UNIT
GROUND
GYPSUM DRY WALL
GRADE BEAM
GRADE
GRATING
GUTTER
GYPSUM
GYPSUM PLASTER
HIGH
HOT & COLD WATER
HOSE BIBB
HOLLOW CORE
HANDICAP
HOLLOW CONCRETE MASONRY UNIT
HEAVY DUTY
HEAD JOINT
HARDBOARD
HEADER
HARDWOOD
HEIGHT
HORIZONTAL LOUVER BLINDS
HOLLOW METAL
HOLLOW METAL DOOR
HOLLOW METAL FRAME
HAND RAIL
HOLD-OPEN
HORIZONTAL
HOUR
HIGH STRENGTH
HIGH STRENGTH BOLT
HEATING
HEATING, VENTILATION, AIR CONDITIONING
HOT WATER
HYDRANT
INSIDE DIAMETER
INSIDE FACE
INCANDESCENT
INLET
INSTALLATION
INSULATION
INTERIOR
INVERT
INVERT ELEVATION
JANITOR
JANITOR'S CLOSET
JOIST
JOINT
KNEE BRACE
KNOCKOUT
KNOCKOUT PANEL
KICK PLATE
KEYWAY
LEFT
LABORATORY
LAY-IN ACOUSTICAL TILE
LAVATORY
POUND
LUMBER
LIGHTWEIGHT CONCRETE MASONRY UNIT
LOAD BEARING
LANDING
LINEAR FOOT
LENGTH
LEFT HAND
LEFT HAND REVERSE
LINOLEUM
LIQUID
LOCKER
LOCKER ROOM
LIVE LOAD
LINTEL
LOCATION
LONGITUDINAL
LARGE
LUMP SUM
LIGHT
LIGHTWEIGHT
LIGHTING
LEVEL
LOUVER
LIGHTWEIGHT PLASTER
LIGHTWEIGHT CONCRETE
METER
MAINTENANCE
MARBLE
MASONRY
MATERIAL
MAXIMUM
MARKERBOARD
MEMBER
METAL CLAD
MEDIUM DENSITY FIBERBOARD
MEDIUM DENSITY OVERLOAD
MATCH EXISTING
MISCELLANEOUS EQUIPMENT
MECHANICAL
MEDIUM
MEMBRANE
MEZZANINE
MANUFACTURING
MANUFACTURER
MANHOLE
MILLIMETER
MINIMUM
MIRROR
MISCELLANEOUS
MARK
MARKERBOARD
MATCH LINE
METAL LABORATORY CASEWORK
MOLDING
MILLWORK
MO
MOD
MTD
MTG
MTL
MTR
MULL
MULT
MVBL
N N/A
NEG
NF
NIC
NO
NOM
NS
NTS
O/O
OA
OC
OD
OD
OF
OFCI
OFF
OFOI
OH
OHD
OPER
OPNG
OPP
OPT
ORIG
OVHD
OXY
OZ
P/C
PAR
PARG
PB
PBD
PC
PCPLAS
PED
PERF
PERIM
PERM
PERP
PF
PFP
PGBD
PH
PL
PLAM
PLAS
PLAT
PLBG
PLYWD
POL
POLY
POLYISO
POS
PR
PREFAB
PRELIM
PRKG
PROJ
PS
PT
PT
PTN
PVC
PVG
PVMT
PWR
QT
QTY
QUAL
R
RAD
RB
RBR
RC
RCP
RD
REC
RECD
RECPT
RECT
REF
REINF
REM
REQD
RESIL
RFM
RFG
RH
RHR
RND
RO
RST
RT
RV
RVS
S S
SALV
SB
SC
SCH
SCMU
SCRN
SD
SECT
SF
SGL
SHR
SHTHG
SHVL
SIM
SJ
SK
MASONRY OPENING
MODULE
MOUNTED
MEETING
METAL
MORTAR
MULLION
MULTIPLE
MOVABLE
NORTH
NOT APPLICABLE
NEGATIVE
NEAR FACE
NOT IN CONTRACT
NUMBER
NOMINAL
NEAR SIDE
NOT TO SCALE
OUT TO OUT
OVERALL
ON CENTER
OUTSIDE DIAMETER
OVERFLOW DRAIN
OUTSIDE FACE
OWNER FURNISHED CONTRACTOR INSTALL
OFFICE
OWNER FURNISHED OWNER INSTALLED
OVERHEAD
OVERHEAD DOOR
OPERABLE
OPENING
OPPOSITE
OPTIONAL
ORIGINAL
OVERHEAD
OXYGEN
OUNCE
PRECAST
PARALLEL
PARGING
PANIC BAR
PARTICLE BOARD
PORTLAND CEMENT
PORTLAND CEMENT PLASTER
PEDESTAL
PERFORATED
PERIMETER
PERMANENT
PERPENDICULAR
PANEL FABRIC
PRE-FINISHED PANELS
PEGBOARD
PHASE
PLASTIC LAMINATE
PLASTIC LAMINATE
PLASTER
PLATFORM
PLUMBING
PLYWOOD
POLISHED
POLYSTYRENE
POLYISOCYANURATE
POSITIVE
PAIR
PREFABRICATED
PRELIMINARY
PARKING
PROJECT
PROJECTION SCREEN
PAINT
PORCELAIN TILE
PARTITION
POLYVINYL CHLORIDE
PAVING
PAVEMENT
POWER
QUARRY TILE
QUANTITY
QUALITY
RISER
RADIUS
RUBBER BASE
RUBBER
REINFORCED CONCRETE
REINFORCED CONCRETE PIPE
ROOF DRAIN
RECESSED
RECEIVED
RECEPTACLE
RECTANGULAR
REFERENCE
REINFORCEMENT
REMOVABLE
REQUIRED
RESILIENT
RECESSED FLOOR MAT
ROOFING
RIGHT HAND
RIGHT HAND REVERSE
ROUND
ROUGH OPENING
RUBBER STAIR TREAD
RUBBER TILE
ROOF VENT
REVERSE
SOUTH
SEATING
SALVAGE
SPLASH BLOCK
SOLID CORE
SCHEDULE
SOLID CONCRETE MASONRY UNIT
SCREEN
STORM DRAIN
SECTION
SYSTEMS FURNITURE
SINGLE
SHOWER
SHEATHING
SHELVES
SIMILAR
SLIP JOINT
SINK
SLA
SLP
SLS
SLV
SM
SMLS
SP
SPCL
SPEC
SPKLR
SPKR
SPRT
SQFT
SQ
SQIN
SQYD
SSK
SS
SSM
ST
ST
STAG
STC
STD
STIR
STL JST
STL PL
STL
STN
STOR
STRUCT
STRUCT STL
SUPPL
SURF
SUSP
SUSP CLG
SVB
SVF
SYM
SYMM
SYST
T&B T&G T
TB
TB-xx
TC
TD
TE
TECH
TEMP
TER
THK
THRES
THRU
TKBD
TLT
TMPD
TMPD GL
TNL
TO
TOF
TOFF
TOJ
TOL
TOS
TOT
TOW
TRNBKL
TS
TV
TYP
UF
UFD
UG
UL
ULT
UNEX
UNFIN
UNO
UPS
UR
UTIL
V
VAC
VAV
VB
VB
VCT
VDB
VERT
VEST
VIB
VNR
VOL
VR
VT
VWC
W/ W/W W/O W
WC
WC
WCPT
WD
WDD
WDW
WF
WF
WGL
WH
WHSE
WL
WLD
WR
WS
WSCT
WT
WTR
WTRPRF
WWM
X SECT
SLATE
SLOPE
SUB-FLOOR LEVELING SYSTEM
SLEEVE
SHEET METAL
SEAMLESS
SPACING
SPECIAL
SPECIFICATION
SPRINKLER
SPEAKER
SUPPORT
SQUARE FOOT
SQUARE
SQUARE INCH
SQUARE YARD
SERVICE SINK
STAINLESS STEEL
SOLID SURFACING MATERIAL
STAIN
STREET
STAGGERED
SOUND TRANSMISSION CLASS
STANDARD
STIRRUP
STEEL JOIST
STEEL PLATE
STEEL
STONE
STORAGE
STRUCTURAL
STRUCTURAL STEEL
SUPPLEMENT
SURFACE
SUSPENDED
SUSPENDED CEILING
SHEET VINYL BASE
SHEET VINYL FLOOR
SYMBOL
SYMMETRICAL
SYSTEM
TOP & BOTTOM
TONGUE & GROOVE
TABLE
TACKBOARD
TEST BORING-xx (E.G. TB-1)
TOP OF CURB
TRENCH DRAIN
TRANSITION EDGE
TECHNICAL
TEMPORARY
TERRAZZO
THICK
THRESHOLD
THROUGH
TACKBOARD
TOILET
TEMPERED
TEMPERED GLASS
TUNNEL
TOP OF
TOP OF FLANGE
TOP OF FINISH FLOOR
TOP OF JOIST
TOLERANCE
TOP OF STEEL
TOTAL
TOP OF WALL
TURNBUCKLE
TUBE STEEL
TELEVISION
TYPICAL
UPHOLSTERY FABRIC
UNDER FLOOR DUCT
UNDERGROUND
UNDERWRITERS LABORATORY
ULTIMATE
UNEXCAVATED
UNFINISHED
UNLESS NOTED OTHERWISE
UNITERRUPTIBLE POWER SUPPLY
URINAL
UTILITY
VOLT
VACUUM
VARIABLE AIR VOLUME
VAPOR BARRIER
VINYL BASE
VINYL COMPOSITION TILE
VISUAL DISPLAY BOARD
VERTICAL
VESTIBULE
VIBRATION
VENEER
VOLUME
VAPOR RETARDER
VINYL TILE
VINYL WALL COVERING
WITH
WALL TO WALL
WITHOUT
WEST
WATER CLOSET
WALL COVERING
WALL CARPET
WOOD
WOOD DOOR
WINDOW
WOOD FLOORING
WIDE FLANGE
WIRE GLASS
WALL HUNG
WAREHOUSE
WIND LOAD
WELDED
WATER RESISTANT
WEATHERSTRIPPING
WAINSCOT
WEIGHT
WATER
WATERPROOFING
WELDED WIRE MESH
CROSS SECTION
PROJECT DESCRIPTION
THIS PROJECT ENTAILS THE RENOVATION OF A KITCHEN AND RESTROOM AREA WITHIN A FORMER
CHURCH AND COMMUNITY CENTER IN THE TOWN OF FRASER. THE BUILDING WILL CONTINUE TO
SUPPORT THE ACTIVITIES OF THE COMMUNITY AND PROVIDE SPACE FOR VARIOUS LOCAL
GROUPS.
THE SCOPE OF WORK WILL ENTAIL THE PARTIAL DEMOLITION OF INTERIOR WALLS AND FIXTURES.
NEW WALLS WILL BE INSTALLED TO ALLOW FOR THE ACCOMMODATION OF NEW RESTROOM AND
KITCHEN SPACE. RESTROOMS LOCATED IN SEPARATE PARTS OF THE BUILDING WILL RECEIVE
NEW FINISHES. MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS WITHIN THE AREA OF WORK
WILL BE ADJUSTED ACCORDINGLY.
DESCRIBING ALL OF THE ARCHITECTURAL DESIGN CONCEPT IS THE GOAL OF THESE DOCUMENTS
VICINITY MAP
PROJECT LOCATION
U S
(Z
E R
E X
S T
EISENHOWER DR
DAO No.:
7230 Meade St.
Westminster, CO 80030
Phone: 720.273.0431
Email: dan@daoarch.com
Web: www.daoarch.com
C :\U se rs
\D ev in \D oc um en ts
\T ow n of
F ra se r
H is to ric C hu rc h
C on st ru ct io n D oc um en ts
_2 1C od es
R ev it de vi n9
H F
G J.
rv t
4/
/2
4:
:0
P
M
G0.0
Standard Symbols, Abbreviations & General
Notes
Town of Fraser
Historic Church Kitchen
Renovation
107 East Eisenhower Drive, Fraser, CO 80442
2022-018
April 28, 2023
DW
LIFE SAFETY SYMBOLS
PROJECT BOUNDARY
XXX FIRE EXTINGUISHER FE
XX PATH OF TRAVEL
(FOR CUMULATIVE DISTANCES REFER TO SCHEDULE)
EXIT DISCHARGE
WIDTH PROVIDED
P: XX"
R: XX" WIDTH REQUIRED
PORTION OF EXISTING BUILDING NOT
INCLUDED WITH THIS PROJECT
APPLICABLE BUILDING CODES
All new work shall comply with the requirements of the codes and standards adopted by the Town of Fraser.
The primary Applicable Codes and Standards are:
The 2021 International Code Series:
The 2021 International Existing Building Code (IEBC) The 2021 International Building Code (IBC) The 2021 International Fire Code (IFC) The 2021 International Mechanical Code (IMC) The 2021 International Energy Conservation Code (IECC) The 2021 International Plumbing Code (IPC)
The 2017 National Electrical Code
Local Amendments as promulgated and adopted by Winter Park, Fraser and Granby
CODE REVIEW
2021 IBC
Chapter 3 - Use and Occupancy Classification 303 - Assembly Group A
303.4 Assembly Group A-3 - Group A-3 occupancy includes assembly uses intended for worship, recreation or amusement and other assembly uses not classified elsewhere in Group A including, but not limited to: Community Halls.
304 - Business Group B
304.1 Business Group B - Business Group B occupancy includes, among others, the use of a building or structure, or a portion thereof, for office, professional or service-type transactions, including storage of records and accounts. Business occupancies shall include, but not be limited to, the following: Training and skill development not in a school or academic program
Chapter 4 - Special Detailed Requirements Based on Occupancy and Use 410 - Stages, Platforms, and Technical Construction Areas
410.2.1 Sage Construction - Stages shall be constructed of materials as required for floors for the type of construction of the building in which such stages are located.
410.2.1.1. Stage Height and Area - Stage areas shall be measured to include the entire performance area and adjacent backstage and support areas not separated from the performance area by fire-resistance-rated construction. Stage height shall be measured from the lowest point on the stage floor to the highest point of the roof or floor deck above the stage.
Chapter 5 - General Building Heights and Areas 504 - Building Height and Number of Stories
504.3and 4 - Allowable building height (A,B Occupancy, Non-sprinklered) - 40' - 1 story.
Building height is existing and will not be altered by this scope of work.
506 - Building Area
506.2.2 - Mixed-occupancy, one-story buildings - The allowable area of a mixed-occupancy building with no more than one story above grade plane shall be determined in accordance with the applicable provisions of Section 508.1 based on equation 5-1 for each applicable occupancy.
A-3 Occupancy is the most restrictive.
Allowable Tabular Area = 6,000 SF, Existing Building Area to Remain = 4,741 SF
Building area is existing and will not be altered by this project.
508 - Mixed Use and Occupancy
508.3 Nonseparated Occupancies - Buildings or portions of buildings that comply with the provisions of this section shall be considered as nonseparated occupancies.
508.3.1 Occupancy Classification - Nonseparated occupancies shall be individually classified in accordance with Section 302.1. The requirements of this code shall apply to each portion of the building based on the occupancy classification of that space. In addition, the most restrictive provisions of Chapter 9 that apply to the nonseparated occupancies shall apply to the total nonseparated occupancy area.
508.3.2 Allowable Building Area and Height - The allowable building area and height of the building or portion thereof shall be based on the most restrictive allowances for the occupancy groups under consideration for the type of construction of the building in accordance with Section 503.1.
508.3.3 Separation - No separation is required between nonseparated occupancies.
Chapter 6 - Types of Construction 602 - Construction Classification
Fire-Resistance Rating Requirements - Per Table 601 Type VB - Primary Structural Frame - 0 hours
Bearing walls exterior and interior - 0 hours Nonbearing walls and partitions - Interior - 0 hours Floor construction and secondary members - 0 hours Roof construction and associated secondary members - 0 hours
Chapter 7 - Fire and Smoke Protection Features 705 - Exterior Walls - Exterior Walls will not be affected by the scope of this project
Chapter 8 - Interior Finishes 803 - Wall and Ceiling Finishes
803.1 - Interior wall and ceiling finish materials shall be classified for fire performance and smoke development in accordance with Section 803.1.1 or 803.1.2, except as shown in Sections 803.1.3 through 803.15. Materials tested in accordance with Section 803.1.1 shall notbe required to be tested in accordance with Section 803.1.2.
803.13 - Interior finish requirements based on Occupancy. - Per Table 803.13 A-3 - Exit enclosures and exit passageways - Class A; Corridors - Class A; Rooms and Enclosed Spaces - Class C B - Exit enclosures and exit passageways - Class A; Corridors - Class B; Rooms and Enclosed Spaces - Class C
Chapter 9 - Fire Protection Systems 901 - General
901.2 - Fire Protection Systems - Fire protection systems shall installed, repaired, operated and maintained in accordance with this code and the International Fire Code.
Fire alarm and detection systems 906 - Portable Fire Extinguishers
906.1 - Portable fire extinguishers shall be installed in the following locations:
1. In group A, and B occupancies.
906.3 - Size and Distribution Low Hazard Occupancy - Minimum 2-A Rating, Max 3,000 Square feet per unit A, 11,250 square feet max., 75 feet max. travel distance.
Chapter 10 - Means of Egress
1003.2 - Ceiling Height - The means of egress shall have a ceiling height of not less than 7'-6".
1004.1 - Design occupant load - See Occupant Load Table.
1005.1 - Minimum required egress width - See Occupant Load Table.
1007 - Exit and Exit Access Doorway Configuration
1007.1.1 - 2 exits are required as the occupant load exceeds 49 per table 1006.3.2(2) -Maximum common path of travel is 75'
1009 - Accessible Means of Egress shall be required. 2 accessible means of egress are required , 2 have been provided in all areas.
1010 - Doors, Gates and Turnstiles
1010.1 - General. Means of egress doors shall meet the requirements of this section.
1010.1.1 - Size of Doors - Doors shall have a minimum clear opening width of 32".
1010.1.2.1 - Door Swing - Doors shall swing in the direction of egress where serving an occupant load of 50 or more, or in an H Occupancy.
1008.1.10 - Panic and Fire Exit Hardware - Doors serving a group A occupancy with an occupant load of 50 or more, shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware.
1013.1 - Exit Signs - Where Required - Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel.
1016 - Exit Access
1016.2 - Egress through intervening spaces.
1016.2.2 - Egress from a room or space shall not pass through adjoining or intervening rooms or areas, except where such adjoining rooms or areas and the area served are accessory to one or the other, are not a Group H occupancy and provide a discernible path of egress travel to an exit.
1017 - Exit Access Travel Distance
1017.2 - Limitations A, B (Unsprinklered) Occupancy - 200'
Chapter 11 - Accessibility 1104 - Accessible Route
1104.1 - Site Arrival Points. Accessible routes within the site shall be provided from public transportation stops; accessible parking; accessible passenger loading zones; and public streets or sidewalks to the accessible building entrance served.
1105 - Accessible Entrances
1105.1 - Public Entrances. In addition to accessible entrances required by sections 1105.1.1 through 1105.1.6, at least 60 percent of all public entrances shall be accessible.
1106 - Parking and Passenger Loading Facilities
1106.1 - Required per table 1106.1 - 1-25 spaces require a minimum of 1 accessible spaces - 1 accessible spaces have been provided.
Chapter 29 - Plumbing Systems Section 2902 - Minimum Plumbing Facilities
Classification Occupancy Description
Water Closets Lavatories Drinking Fountains OtherFemale
Bathtubs/ Showers
Total Required
Total Provided
Table 2902.1
3 12
3 13
N/A
N/A
Male
This project entails the renovation of the kitchen and existing restrooms, and the replacement with two existing restrooms with one new accessible restroom, in the Fraser Historic Church. "Historic" is a moniker for the building and not an official designation.
This project consists of A-3 and B occupancies. Total allowable building area is calculated based off this occupancy.
2021 IEBC
Chapter 3 - Provisions for All Compliance Methods 301 - Administration
301.3.2 Work area compliance method - Repairs, alterations, additions, changes in occupancy and relocated buildings complying with the applicable requirements of Chapters 6 through 12 of this code shall be considered in compliance with the provisions of this code.
302 - General Provisions
302.2 Additional Codes - Alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall comply with the provisions for alterations, repairs, additions and changes of occupancy or relocation, respectively, in this code and the International Energy Conservation Code, International Fire Code, International Fuel Gas Code, International Mechanical Code, International Plumbing Code, International Property Maintenance Code, International Private Sewage Disposal Code, International Residential Code and NFPA 70. Where provisions of the other codes conflict with provisions of this code, the provisions of this code shall take precedence.
302.3 Existing Materials - Materials already in use in a building in compliance with requirements or approvals in effect at the time of their erection or installation shall be permitted to remain in use unless determined by the building official to be unsafe.
302.4 New and Replacement Materials - Except as otherwise required or permitted by this code, materials permitted by the applicable code for new construction shall be used. Like materials shall be permitted for repairs and alterations, provided no unsafe condition is created. Hazardous materials shall not be used where the code for new construction would not permit their use in buildings of similar occupancy, purpose and location.
302.5 Occupancy and Use - Occupancy and use shall be determined in accordance with Chapter 3 of the International Building Code.
Chapter 6 - Classification of Work 601 - General
601.2 Work Area - The work area shall be identified on the construction documents.
603 - Alteration -- Level 2
603.1 Scope - Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipmentand shall apply where the work area is equal to or less than 50 percent of the building area.
603.2 Application - Level 2 alterations shall comply with the provisions of Chapter 7 for Level 1 alterations as well as the provisions of Chapter 8.
Chapter 7 - Alterations -- Level 1 701 - General
701.2 Conformance - An existing building or portion thereof shall not be altered such that the building becomes less safe than its existing condition.
702 - Building Elements and Materials
702.1 Interior Finishes - All newly installed interior wall and ceiling finishes shall comply with Chapter 8 of the International Building Code.
702.2 Interior Floor Finish - New interior floor finish, including new carpeting used as an interior floor finish material, shall comply with Section 804 of the International Building Code.
702.3 Interior Trim - All newly installed interior trim materials shall comply with Section 806 of the International Building Code.
702.7 Materials and Methods - All new work shall comply with the materials and methods requirements in the International Building Code, International Energy Conservation Code, International Mechanical Code, and International Plumbing Code, as applicable, that specify material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building.
[FG] 702.6.1 International Fuel Gas Code - The following sections of the International Fuel Gas Code shall constitute the fuel gas materials and methods requirements for Level 1 alterations.
1. All of Chapter 3, entitled “General Regulations,” except Sections 303.7 and 306.
2. All of Chapter 4, entitled “Gas Piping Installations,” except Sections 401.8 and 402.3.
2.1. Sections 401.8 and 402.3 shall apply when the work being performed increases the load on the system such that the existing pipe does not meet the size required by code.
Existing systems that are modified shall not require resizing as long as the load on the system is not increased and the system length is not increased even if the altered system does not meet code minimums.
3. All of Chapter 5, entitled "Chimneys and Vents"
4. All of Chapter 6, entitled " Specific Appliances"
703 - Fire Protection
703.1 General - Alterations shall be done in a manner that maintains the level of fire protection provided.
704 - Means of Egress
704.1 General - Alterations shall be done in a manner that maintains the level of protection provided for the means of egress.
708 - Energy Conservation
708.1 Minimum Requirements - Level 1 alterations to existing buildings or structures are permitted without requiring the entire building or structure to comply with the energy requirements of the
International Energy Conservation Code or International Residential Code. The alterations shall conform to the energy requirements of the International Energy Conservation Code or International Residential Code as they relate to new construction only.
Chapter 8 - Alterations -- Level 2 801 - General
801.2 Alteration Level 1 Compliance - In addition to the requirements of this chapter, all work shall comply with the requirements of Chapter 7.
801.4 Compliance - All new construction elements, components, systems, and spaces shall comply with the requirements of the International Building Code.
Exception 2 - Newly installed electrical equipment shall comply with the requirements of Section 808.
Exception 4 - The minimum ceiling height of the newly created habitable and occupiable spaces and corridors shall be 7 feet.
802 - Building Elements and Materials
802.4 Interior Finish - The interior finish of walls and ceilings in exits and corridors in any work area shall comply with the requirements of the International Building Code.
803 - Fire Protection
803.1 Scope - The requirements of this section shall be limited to work areas in which Level 2 alterations are being performed, and where specified they shall apply throughout the floor on which the work areas are located or otherwise beyond the work area.
805 - Structural
[BS] 805.2 Existing Structural Elements Carrying Gravity Loads - Any existing gravity load-carrying structural element for which an alteration causes an increase in design dead, live or snow load, including snow drift effects, of more than 5 percent shall be replaced or altered as needed to carry the gravity loads required by the International Building Code for new structures. Any existing gravity load-carrying structural element whose gravity load-carrying capacity is decreased as part of the alteration shall be shown to have the capacity to resist the applicable design dead, live and snow loads, including snow drift effects, required by the International Building Code for new structures.
806 - Electrical
806.1 New Installations - All newly installed electrical equipment and wiring relating to work done in any work area shall comply with all applicable requirements of NFPA 70 except as provided for in Section 808.3.
806.2 Existing Installations - Existing Wiring in all work areas in Group A-1, A-2, A-5 H and I occupancies shall be upgraded to meet the materials and methods requirements of chapter 7.
807 - Mechanical
807.1 Reconfigured or Converted Spaces - All reconfigured spaces intended for occupancy and all spaces converted to habitable or occupiable space in any work area shall be provided with natural or mechanical ventilation in accordance with the International Mechanical Code.
807.3 Local Exhaust - All newly introduced devices, equipment, or operations that produce airborne particulate matter, odors, fumes, vapor, combustion products, gaseous contaminants, pathogenic and allergenic organisms, and microbial contaminants in such quantities as to affect adversely or impair health or cause discomfort to occupants shall be provided with local exhaust.
809 - Energy Conservation
809.1 Minimum Requirements - Level 2 alterations to existing buildings or structures are permitted without requiring the entire building or structure to comply with the energy requirements of the International Energy Conservation Code or International Residential Code. The alterations shall conform to the energy requirements of the International Energy Conservation Code or International Residential Code as they relate to new construction only.
ASSEMBLY A-3 Auditoriums without permanent seating, art galleries, exhibition halls, museums, lecture halls, libraries, arcades and gymnasiums
N/A 1 per 500
151.25/500 =.303
BUSINESS B Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, light industrial and similar uses
N/A 1 Service Sink
1 Service Sink
.919 1.478 .574 .574 .46
1 per 125
75.625/125 =.605
Occupant load:
151.25 (151.25/2=75.625)
Occupant load:
15.67 (15.67/2=7.835)
1 per 65
75.625/65 =1.164
1 per 25
7.835/25= .314
1 per 25
7.835/25= .314
FemaleMale
1 per 40 for the first 80 and 1 per 80 for remainder
7.835/40 =.196
7.835/40 =.196
1 per 200
75.625/200 =.378
1 per 200
75.625/200 =.378
1 per 100
15.67/100 =.157
A-3
691 SF
A-3
1045 SF
B
651 SF
B
652 SF
A-3
279 SF
B
61 SFB
203 SF
1A 1B
P: 36 R: 4.16
P: 72 R: 4.16
P: 36 R: 4.16
P: 36 R: 4.16
P: 36 R: 4.16
FE
DAO No.:
7230 Meade St.
Westminster, CO 80030
Phone: 720.273.0431
Email: dan@daoarch.com
Web: www.daoarch.com
C :\U se rs
\D ev in \D oc um en ts
\T ow n of
F ra se r
H is to ric C hu rc h
C on st ru ct io n D oc um en ts
_2 1C od es
R ev it de vi n9
H F
G J.
rv t
4/
/2
4:
:0
P
M
G0.1
Building Code Data
Town of Fraser
Historic Church Kitchen
Renovation
107 East Eisenhower Drive, Fraser, CO 80442
2022-018
April 28, 2023
EGRESS TRAVEL DISTANCES
PATH NAME DISTANCE
1A 44' - 10"
1B 76' - 2 11/32"
Occupant Load Table
Number Name Occupancy
Classification Area Area Function SF Per
Occupant Occupant
Load Required
Exiting Width
101 Office (IBC) B 61 SF IBC_Business areas 100 SF 0.61 0.1
102 Performance Room (IBC) A-3 691 SF IBC_Assembly: with fixed seats 0.00 0
102a Platform (IBC) A-3 279 SF IBC_Stages and Platforms 15 SF 18.61 3.7
103 Multi-Purpose Room (IBC) A-3 1045 SF IBC_Assembly: without fixed seats - Unconcentrated (tables and chairs) 15 SF 69.64 13.9
104 Kitchen (IBC) B 203 SF IBC_Business areas 100 SF 2.03 0.4
110 Pottery Studio (IBC) B 652 SF IBC_Business areas 100 SF 6.52 1.3
113 Classroom (IBC) B 651 SF IBC_Business areas 100 SF 6.51 1.3
Grand total: 7 3582 SF 103.92 20.8
SCALE: 1/8" = 1'-0"
LIFE SAFETY PLAN
166.92
DW
R e fr ig e ra to r
DN THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND
CONDITIONS SHOWN ON THE PLANS PRIOR TO COMMENCEMENT OF THE WORK.
IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO COORDINATE
INSTALLATION OF NEW WORK WITHIN THESE EXISTING CONDITIONS. ANY
DEVIATIONS IN EXISTING CONDITIONS OR DIMENSIONS INDICATED SHALL BE
COORDINATED WITH THE ARCHITECT/ENGINEER AND OWNER IN ORDER TO
MODIFY THE PLANS ACCORDINGLY.
THE EXISTING BUILDING SHALL BE PROTECTED FROM WEATHER AT ALL TIMES.
OPENINGS AND PENETRATIONS SHALL BE PROTECTED WITH DURABLE,
INSULATED TEMPORARY CONSTRUCTION. COORDINATE SECURITY
REQUIREMENTS WITH THE OWNER.
ALL WORK IS TO BE PERFORMED IN SUCH A MANNER AS TO MINIMIZE THE
IMPACT ON AREAS ADJACENT TO THE AREAS OF CONSTRUCTION.
REMOVE EXISTING FLOORS, WALLS AND CEILINGS AS REQUIRED FOR NEW
CONSTRUCTION. PATCH, REPAIR AND PREPARE ADJACENT SURFACES AS
REQUIRED FOR NEW CONSTRUCTION AND FINISHES.
REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR
ADDITIONAL INFORMATION PERTAINING TO DEMOLITION.
REMOVE EXISTING FURNITURE, FIXTURES AND EQUIPMENT (INCLUDING
ARTWORK AND MARKER/TACK BOARDS AS REQUIRED FOR NEW CONSTRUCTION.
COORDINATE SALVAGE AND STORAGE OF EQUIPMENT WITH OWNER AS
REQUIRED. PROTECT AND STORE ALL ITEMS DESIGNATED TO BE SALVAGED
FOR REINSTALLATION.
ALL OPENINGS AND VOIDS LEFT BY THE REMOVAL OF EXISTING CONSTRUCTION,
EQUIPMENT, PIPING, DUCTS, ETC. SHALL BE PROPERLY PATCHED AND CLOSED
OFF TO MAINTAIN PROPER FIRE RATING IN WALLS, IF APPLICABLE. PATCH AND
PREPARE ANY AREAS TO RECEIVE NEW FINISHES AS REQUIRED.
THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE DETECTION OR
REMOVAL OF ANY HAZARDOUS MATERIALS, INCLUDING, BUT NOT LIMITED TO,
ASBESTOS IN ANY FORM. PARTIES RESPONSIBLE FOR DEMOLITION SHALL
NOTIFY THE OWNER IMMEDIATELY OF ANY SUSPECTED MATERIALS.
OWNER HAS RIGHT TO CLAIM ANY MATERIALS AND/OR EQUIPMENT THAT IS
SCHEDULED TO BE DEMOLISHED OR REMOVED FROM THE SITE.
ALL EXISTING BUILDING ELEMENTS TO REMAIN SHALL BE PROTECTED DURING
CONSTRUCTION.
REMOVE EXISTING FLOOR FINISHES WHERE INDICATED. DEMOLITION INCLUDES
REMOVAL OF EXISTING ADHESIVES, GROUTING BED, ETC. PATCH AND PREPARE
FLOOR AND WALL SURFACES AS REQUIRED FOR NEW CONSTRUCTION AND
FINISHES. WHERE FLOOR FINISH IS REMOVED, BASE WILL BE REMOVED. SEE
FINISH PLAN FOR ADDITIONAL INFORMATION.
PREPARE EXISTING SUBSTRATES TO REMAIN AS REQUIRED TO RECEIVE NEW
FINISHES.
GENERAL DEMOLITION NOTES
1.
2.
5.
6.
7.
8.
10.
11.
12.
3.
4.
9.
REMOVE EXISTING WALL ASSEMBLY IN ITS ENTIRETY OR AS REQUIRED FOR
NEW CONSTRUCTION. PATCH AND PREPARE ADJACENT SURFACES AS
REQUIRED FOR NEW CONSTRUCTION.
REMOVE EXISTING DOOR AND FRAME ASSEMBLY IN ITS ENTIRETY. PATCH AND
PREPARE ADJACENT SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
REMOVE EXISTING CASEWORK AND ASSOCIATED COUNTERTOP IN ITS
ENTIRETY. PATCH AND PREPARE ADJACENT SURFACES AS REQUIRED FOR
NEW CONSTRUCTION.
REMOVE EXISTING FLOOR FINISH MATERIAL IN ITS ENTIRETY. PATCH AND
PREPARE ADJACENT SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
REMOVE EXISTING APPLIANCES AND EQUIPMENT AS REQUIRED FOR NEW
CONSTRUCTION. COORDINATE SALVAGE AND STORAGE OF EQUIPMENT WITH
OWNER.
REMOVE EXISTING SINK IN ITS ENTIRETY. PATCH AND PREPARE ADJACENT
SURFACES AS REQUIRED FOR NEW CONSTRUCTION. SEE PLUMBING
DRAWINGS FOR ADDITIONAL INFORMATION.
REMOVE EXISTING TOILET FIXTURE IN ITS ENTIRETY. PATCH AND PREPARE
ADJACENT SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
REMOVE EXISTING GAS FIRED WATER HEATER IN ITS ENTIRETY. PATCH AND
PREPARE ADJACENT SURFACES AS REQUIRED FOR NEW CONSTRUCTION. SEE
MECHANICAL FOR ADDITIONAL INFORMATION
REMOVE EXISTING GAS FIRED HEATER IN ITS ENTIRETY AND CAP GAS LINE.
PATCH AND PREPARE ADJACENT SURFACES AS REQUIRED FOR NEW
CONSTRUCTION. SEE MECHANICAL FOR ADDITIONAL INFORMATION.
REMOVE PORTION OF EXISTING WALL ASSEMBLY AS REQUIRED FOR
INSTALLATION OF NEW DOOR. PATCH AND PREPARE SURFACES AS REQUIRED
FOR NEW CONSTRUCTION.
REMOVE PORTION OF EXISTING WALL ASSEMBLY AS REQUIRED FOR
INSTALLATION OF A NEW CASED OPENING. PATCH AND PREPARE ADJACENT
SURFACES AS REQUIRED FOR NEW CONSTRUCTION
REMOVE EXISTING FRAMED OPENING IN ITS ENTIRETY. PARCH AND PREPARE
ADJACENT SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
REMOVE EXISTING STAIR ASSEMBLY IN ITS ENTIRETY. PATCH AND PREPARE
ADJACENT SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
DEMOLITION KEY NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
9.10.
11.
12.
13.
AREA OF WORK
3 3
3 3
6 6
AREA OF WORK. PROVIDE
ALTERNATE PRICING IN THIS AREA
AD1.0 2
7 7
HATCHED AREA NOT IN SCOPE
HATCHED AREA NOT IN SCOPE
HATCHED AREA NOT IN SCOPE
4' -0
/4
3'
-1
1' -8
/4
UP
107'-6 1/2"
(E) CEILING
(E) FIN. FLOOR
100'-0"
6' -8
1'-8 3/4"
DAO No.:
7230 Meade St.
Westminster, CO 80030
Phone: 720.273.0431
Email: dan@daoarch.com
Web: www.daoarch.com
C :\U se rs
\D ev in \D oc um en ts
\T ow n of
F ra se r
H is to ric C hu rc h
C on st ru ct io n D oc um en ts
_2 1C od es
R ev it de vi n9
H F
G J.
rv t
4/
/2
4:
:0
P
M
AD1.0
First Floor Demolition Plan
Town of Fraser
Historic Church Kitchen
Renovation
107 East Eisenhower Drive, Fraser, CO 80442
2022-018
April 28, 2023
SCALE: 1/4" = 1'-0"
Demolition Plan1
SCALE: 1/4" = 1'-0"
AD1.01
Community Room Demo. Elevation2
THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND
CONDITIONS SHOWN ON THE PLANS PRIOR TO COMMENCEMENT OF THE WORK. IT
SHALL BE THE CONTRACTORS RESPONSIBILITY TO COORDINATE INSTALLATION OF
NEW WORK WITHIN THESE EXISTING CONDITIONS. ANY DEVIATIONS IN EXISTING
CONDITIONS OR DIMENSIONS INDICATED SHALL BE COORDINATED WITH THE
ARCHITECT/ENGINEER AND OWNER IN ORDER TO MODIFY THE PLANS
ACCORDINGLY.
ALL WORK IS TO BE PERFORMED IN SUCH A MANNER AS TO MINIMIZE THE IMPACT
ON AREAS ABOVE, BELOW AND ADJACENT TO THE AREAS OF CONSTRUCTION.
REMOVE EXISTING FLOORS, WALLS AND CEILINGS AS REQUIRED FOR NEW
CONSTRUCTION. PATCH, REPAIR AND PREPARE ADJACENT SURFACES AS
REQUIRED FOR NEW CONSTRUCTION AND FINISHES.
REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION PERTAINING TO DEMOLITION.
ALL OPENINGS AND VOIDS LEFT BY THE REMOVAL OF EXISTING CONSTRUCTION,
EQUIPMENT, PIPING, DUCTS, ETC. SHALL BE PROPERLY PATCHED AND CLOSED OFF
TO MAINTAIN PROPER FIRE RATING IN WALLS. PATCH AND PREPARE ANY AREAS TO
RECEIVE NEW FINISHES AS REQUIRED.
THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE DETECTION OR REMOVAL
OF ANY HAZARDOUS MATERIALS, INCLUDING, BUT NOT LIMITED TO, ASBESTOS IN
ANY FORM. PARTIES RESPONSIBLE FOR DEMOLITION SHALL NOTIFY THE OWNER
IMMEDIATELY OF ANY SUSPECTED MATERIALS.
THE OWNER HAS RIGHT TO CLAIM ANY MATERIALS AND/OR EQUIPMENT THAT IS
SCHEDULED TO BE DEMOLISHED OR REMOVED FROM THE SITE.
ALL EXISTING BUILDING ELEMENTS TO REMAIN SHALL BE PROTECTED DURING
CONSTRUCTION.
PREPARE EXISTING SUBSTRATES TO REMAIN AS REQUIRED TO RECEIVE NEW
FINISHES.
GENERAL DEMOLITION RCP NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
REMOVE EXISTING LIGHT FIXTURE IN ITS ENTIRETY. PATCH AND PREPARE ADJACENT
SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
DEMOLITION RCP KEY NOTES
1.
2.
3.
4.
REMOVE MECHANICAL FLUE IN ITS ENTIRETY. PATCH AND PREPARE ADJACENT
SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
REMOVE EXISTING PLYWOOD CEILING FINISH IN ITS ENTIRETY. PATCH AND PREPARE
ADJACENT SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
REMOVE EXISTING GPDW CEILING AS REQUIRED FOR NEW CONSTRUCTION. PATCH
AND PREPARE ADJACENT SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
5.
REMOVE EXISTING VENT LOUVERS IN THEIR ENTIRETY. COORDINATE WITH
MECHANICAL. PATCH AND PREPARE ADJACENT SURFACES AS REQUIRED FOR NEW
CONSTRUCTION.
REMOVE EXISTING SOFFIT IN ITS ENTIRETY. PATCH AND PREPARE ADJACENT
SURFACES AS REQUIRED FOR NEW CONSTRUCTION.
6.
TOWER ACCESS HATCH
(E) CEILING FAN, TYP
/2
/2
12" / 12" 12" / 12"
14'-2 1/2"
10'-5"
10'-6 1/2"
8'-2" 8'-6"
8'-4 1/4"
8'-5"
/2
(E) PENDANT LIGHT, TYP
(E) TROFFER LIGHT, TYP
(E) EXIT SIGNAGE, TYP
(E) SKYLIGHT
AREA OF WORK
1 1
3 3
HATCHED AREA NOT IN SCOPE
HATCHED AREA NOT IN SCOPE
DEMOLITION LEGEND
EXTENTS OF DEMOLITION AREA
DAO No.:
7230 Meade St.
Westminster, CO 80030
Phone: 720.273.0431
Email: dan@daoarch.com
Web: www.daoarch.com
C :\U se rs
\D ev in \D oc um en ts
\T ow n of
F ra se r
H is to ric C hu rc h
C on st ru ct io n D oc um en ts
_2 1C od es
R ev it de vi n9
H F
G J.
rv t
4/
/2
4:
:0
P
M
AD1.1
First Floor Demolition RCP
Town of Fraser
Historic Church Kitchen
Renovation
107 East Eisenhower Drive, Fraser, CO 80442
2022-018
April 28, 2023
SCALE: 1/4" = 1'-0"
Demolition Reflected Ceiling Plan1
DN
E
F
DW
15'-8 1/2"
15'-0 1/2"
10'-7"
4'-8"33'-9"
9' -1
1/
2"
1 1/2"3'-3"
4' -2
Sanctuary (E) 102102
Community Room (E)
103103
Vestibule (E)
103A103A
Link (E) 108108
Hallway (E) 109109
Pottery Studio (E)
110110
Mech (E) 110A110A
Stor. (E) 110B110B
Women's Restroom
(E) 111111
Men's Restroom
(E) 112112
Stor. (E) 113B113B
Mech (E) 113A113A
Classroom (E) 113113
Vestibule (E)
102A102A
WH
KILN
KILN
(E) ELECTRICAL PANELS
0'-8"
0'-0"
0'-8"
0'-1 3/4"
0'-8"
(E) WASH BASIN
(E) FIREPLACE WITH GAS INSET
AREA OF WORK
A3.0
A3.0
13'-2 1/4"
6 3/4"
AREA OF WORK. PROVIDE
ALTERNATE PRICING IN THIS AREA
A3 A6
A
A3
A3
A
A6.0 1
A6.02 A6.0 11
A6.0 14
A6.06 A6.015
Entry (E) 100100
Storage/Office 101101
Kitchen 104104
Stor.
100A100A
Restroom 105105
12 13
A6.0
A6.0
17 20
A3.0
A3.0
4'-3 3/8" 3'-0" 6" 4 7/8" 6 1/2" 6'-0" 6 1/4"
8' -8
/2
6" 3'
-0
1' -0
3/
4"
1' -0
/8
3'
-0
4'-8"
1 7
104a
104b
5a
1a
100aa
1'-6"
3' -0
5'
-8
HATCHED AREA NOT IN SCOPE
HATCHED AREA NOT IN SCOPE
HATCHED AREA NOT IN SCOPE
Sanctuary Platform
(E) 102a102a
DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE
CONTRACT DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR
THE COMPLETE SCOPE OF WORK. NOTIFY ARCHITECT IMMEDIATELY FOR
CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE
DISCOVERED.
DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED &
NOT FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION.
ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED
WALLS OR SURFACES UNLESS NOTED OTHERWISE.
REFER TO DEMOLITION DRAWINGS FOR WORK REQUIRED IN ADVANCE OF
CONSTRUCTION AND COORDINATE ACCORDINGLY.
ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT
PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
REFER TO STRUCTURAL, MECHANICAL, ELECTRICAL, DRAWINGS FOR
ADDITIONAL INFORMATION.
CODE REQUIRED SIGNAGE TO BE PROVIDED BY THE CONTRACTOR, OTHER
INTERIOR SIGNAGE TO BE PROVIDED BY OWNER.
FURNITURE AND EQUIPMENT PROVIDED BY OWNER.
GENERAL PLAN NOTES
1.
2.
3.
4.
5.
6.
7.
8.
NEW CASEWORK. SEE INTERIOR ELEVATIONS FOR EXTENTS
NEW SELF-RIMMING SINGLE BASIN SINK, STAINLESS STEEL. PROVIDE
GARBAGE DISPOSAL.
NEW DISHWASHER, FINGER PRINT RESISTANT STAINLESS STEEL. OFOI
NEW ELECTRIC RANGE, FINGER PRINT RESISTANT STAINLESS STEEL. OFOI
NEW REFRIGERATOR, FINGER PRINT RESISTANT STAINLESS STEEL. OFOI
NEW RANGE HOOD OFOI/OFCI
NEW MOP BASIN CFCI. BASIS OF DESIGN ACORN TRH-242410
NEW SELF-RIMMING LAVATORY SINK
NEW WALL FLOOR MOUNTED WATER CLOSET
NEW HAND DRIER. SEE INTERIOR ELEVATIONS
NEW GRAB BAR. SEE INTERIOR ELEVATIONS
NEW CHANGING STATION. SEE INTERIOR ELEVATIONS
KEY NOTES
WALL PARTITION TYPES
5/8" TYPE 'X' GPDW, 2x6 STUDS AT 16" O.C., 5/8" TYPE 'X' GPDW. FROM
FINISHED FLOOR TO 6" ABOVE FINISHED CEILING. BRACE AS REQUIRED.
A6
5/8" TYPE 'X' GPDW, 2x4 STUDS AT 16" O.C., 5/8" TYPE 'X' GPDW. FROM FINISHED
FLOOR TO FINISHED CEILING.
A3
DAO No.:
7230 Meade St.
Westminster, CO 80030
Phone: 720.273.0431
Email: dan@daoarch.com
Web: www.daoarch.com
C :\U se rs
\D ev in \D oc um en ts
\T ow n of
F ra se r
H is to ric C hu rc h
C on st ru ct io n D oc um en ts
_2 1C od es
R ev it de vi n9
H F
G J.
rv t
4/
/2
4:
:0
P
M
A1.0
First Floor Plan
Town of Fraser
Historic Church Kitchen
Renovation
107 East Eisenhower Drive, Fraser, CO 80442
2022-018
April 28, 2023
First Floor Plan1
RCP GENERAL NOTES:
DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF
THE CONTRACT DOCUMENTS, REVIEW ALL DRAWINGS AND
SPECIFICATIONS FOR THE COMPLETE SCOPE OF WORK. NOTIFY
ARCHITECT IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES,
CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.
DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS
REQUIRED & NOT FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR
CLARIFICATION.
ALL DIMENSIONS ARE TO COLUMN CENTERLINES, CENTER OF
SUSPENDED CEILING GRIDS OR FACE OF FINISHED WALLS/SOFFITS
UNLESS NOTED OTHERWISE.
REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHT FIXTURE
SPECIFIC INFORMATION.
ABOVE CASEWORK SOFFITS ARE 1" DEEPER AND 1" LONGER THAN THE
CASEWORK BELOW.
1.
2.
3.
4.
5.
ATTIC ACCESS LADDER. BASIS OF DESIGN WERNER AH2210.
COORDINATE LOCATION WITH JOISTS. RE: STRUCTURAL
RCP KEY NOTES
1.
GPDW SOFFIT ABOVE CASEWORK2.
RCP SYMBOL LEGEND
EXISTING GPDW CEILING
NEW GPDW CEILING
NEW HVAC SUPPLY DIFFUSER
NEW HVAC RETURN DIFFUSER
NEW RECESSED CAN DOWNLIGHT
NEW SURFACE LIGHT FIXTURE
NEW CEILING MOUNTED OCCUPANCY
SENSOR
NEW STRIP SURFACE LIGHT FIXTURE
NEW WALL MOUNTED OCCUPANCY
SENSOR
1" / 12"
(E) EXIT SIGNAGE, TYP
AREA OF WORK
Kitchen 104104
Restroom 105105
Storage/Office 101101
Entry (E) 100100
Stor.
100A100A
8'-3"
8'-3"
8'-3"
8'-3"
8'-3"
GPDW
GPDW
GPDW
GPDW
GPDW
F.V.
2'-3 1/2"F.V.
3'-11"
3' -0
4'
-6
DAO No.:
7230 Meade St.
Westminster, CO 80030
Phone: 720.273.0431
Email: dan@daoarch.com
Web: www.daoarch.com
C :\U se rs
\D ev in \D oc um en ts
\T ow n of
F ra se r
H is to ric C hu rc h
C on st ru ct io n D oc um en ts
_2 1C od es
R ev it de vi n9
H F
G J.
rv t
4/
/2
4:
:0
P
M
A1.1
First Floor RCP
Town of Fraser
Historic Church Kitchen
Renovation
107 East Eisenhower Drive, Fraser, CO 80442
2022-018
April 28, 2023
Partial First Floor RCP1
107'-7"
100'-0"
CEILING
(E) FIN. FLOOR
NEW TACK BOARD
(E) BASE
(E) TRIM
NEW 4" TRIM. PT TO MATCH EXISTING
NEW 4" TRIM. PT TO MATCH EXISTING
OPEN TO
BEYOND
F.V.
1'-4 3/4"
A6.1
A6.1
A6.1
A6.1 (E) WINDOW
107'-7"
100'-0"
FIN. FLOOR
FIN CEILING
NEW 4" TRIM, TYP. PT
NEW 4" BASE
4"
1/ 2"
2' -1
1/
2"
3'-0" 3'-0"
106'-8"
T.O. OPENING
NEW COUNTER WITH BACKSPLASH
NEW WOOD CABINETS
OPEN TO
BEYOND GPDW, PAINT23
A6.0
(E) WINDOW
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
RANGE HOOD OFCI
NEW COUNTER WITH BACKSPLASH
NEW WOOD CABINETS
DISHWASHER OFOI
NEW WOOD CABINETS
4" TRIM, PT
GPDW, PAINT
2'-0"1'-11 3/4"2'-9"2'-3"
4"
1/ 2"
2' -7
1/ 2"
2' -6
1'
-6
A6.0
A6.0
GPDW SOFFIT, PAINT
1'-1 1/2"
2'-0"2'-0"
ACCESSIBLE SINK SHROUD
A6.0
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
RANGE HOOD OFOINEW COUNTER WITH
BACKSPLASH
NEW WOOD CABINETS
NEW WOOD CABINETS
4" TRIM, PT
GPDW, PAINT
ELECTRIC RANGE OFOI
REFRIGERATOR OFOI
(E) BOXOUT
4" BASE
2'-9" 2'-6"
1'-9" 2'-6"
1' -6
2'
-6 " 1'
-6
A6.0
GPDW SOFFIT, PAINT
107'-7"
100'-0"
FIN. FLOOR
FIN. FLOOR
NEW WOOD CABINETS
GPDW, PAINT
(E) BOXOUT, PAINT
4" BASE
2' -1
1/
2" F
V
1/
2" 2'
-6
1' -6
NEW COUNTER
3'-0" 2'-0" 3'-0"
A6.0
GPDW SOFFIT, PAINT
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
GPDW, PAINT
4" TRIM, PT
4" BASE
(E) GPDW, PAINT
(E) TRIM, PAINT
107'-7"
100'-0"
GPDW, PAINT
4" TRIM, PT
4" BASE
107'-7"
100'-0"
FIN. FLOOR
FIN. FLOOR
(E) GPDW, PAINT
(E) TRIM, PT
4" BASE
(E) SIGN
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
3'-0" 6" MAX
3' -4
B
O M
IR
R
O R
GPDW, PAINT
4" BASE
MIRROR OFOI
LAVATORY
HAND DRIER CFCI
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
3'-6"
MAX
1'-0"
3'-4"
1'
M
IN
5"
2' -1
0"
GPDW, PAINT
4" BASE
WATER CLOSET
SANITARY NAPKIN DISPOSAL CFCI
TOILET PAPER DISPENSER CFCI
CHANGING STATION KB310 CFCI
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
GPDW, PAINT
4" BASE
CHANGING STATION KB310 CFCI
T O
S U
R F
A C
E 2'
-6
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
GPDW, PAINT
4" BASE
LAVATORY
4" TRIM, PT
WOOD VANITY CABINET
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
GPDW, PAINT
4" BASE
4" TRIM, PT
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
(E) GPDW, PAINT
(E) TRIM, PT
4" BASE
107'-7"
100'-0"
FIN. FLOOR
FIN. CEILING
ACCROVIN FRP
WASH BASIN ACORN TRH-242410
4" BASE
107'-5 1/4"
99'-5 3/4"
(E) FLOOR
(E) CEILING
(E) PANEL, PAINT
(E) FIXTURES
4" BASE
(E) TRIM, PAINT
107'-5 1/4"
99'-5 3/4"
(E) FLOOR
(E) CEILING
(E) FIXTURES
4" BASE
(E) PANEL, PAINT
NEW WATER CLOSET
107'-5 1/4"
99'-5 3/4"
(E) CEILING
(E) FLOOR
(E) PANEL, PAINT
(E) FIXTURES
4" BASE
NEW WATER CLOSET
107'-5 1/4"
99'-5 3/4"
(E) FLOOR
(E) CEILING
(E) PANEL, PAINT
(E) FIXTURES
4" BASE
107'-5 1/4"
99'-5 3/4"
(E) FLOOR
(E) CEILING
(E) PANEL, PAINT
(E) FIXTURES
4" BASE
(E) TRIM, PAINT
107'-5 1/4"
99'-5 3/4"
(E) FLOOR
(E) CEILING
FRP OVER (E) PANEL
(E) FIXTURES
4" BASE
NEW WATER CLOSET
RECESSED KV STANDARDS W/
ADJUSTABLE METAL SHELF
CLIPS
3/4" WOOD VENEERED
PLYWOOD ADJUSTABLE SHELF
3/4" WOOD VENEERED PLYWOOD
UPPER CABINET AND DOOR
2' -6
1'
-6
1/
2"
1/ 2"
1' -1
1" 4"
SOLID SURFACE COUNTER
TOP W/ 4" BACKSPLASH
3/4" WOOD VENEERED PLYWOOD
BASE CABINET AND DOOR
BASE, RE: ROOM FINISH
SCHEDULE
RECESSED KV
STANDARDS
3/4" MAPLE VENEERED
PLYWOOD SHELF
2'-0"
GPDW CEILING
5/8" TYPE 'X' GPDW, PAINT
BRACE TO WALL AT 48" O.C.
2X4 WOOD SOFFIT
FRAMING AT 16" O.C.
1'-0"
1"
2' -1
0"
2' -6
4"
1/
2"
1/
2" 1'
-1 1"
2'-1 1/2"
1 1/2"
SOLID SURFACE
COUNTERTOP AND 4"
BACKSPLASH
3/4" FLUSH OVERLAY WOOD
VENEERED PLYWOOD BASE
CABINET AND DOOR
4" RUBBER BASE
2' -1
0" 3/4" WOOD VENEER PLYWOOD
ADJUSTABLE SHELF
3"
2' -6
4"
1/
2"
1/
2" 1'
-1 1"
2'-1 1/2" 1'-6"
1 1/2"
SOLID SURFACE
COUNTERTOP
3/4" FLUSH OVERLAY WOOD
VENEERED PLYWOOD BASE
CABINET AND DOOR
4" RUBBER BASE
2' -1
0" 3/4" WOOD VENEER PLYWOOD
ADJUSTABLE SHELF
3"
3'-7 1/2"
EXISTING WALL
1' -3
5'
-7
UNDERMOUNT RANGE HOOD
ELECTRIC RANGE OFOI
GPDW CEILING
5/8" TYPE 'X' GPDW, PAINT
BRACE TO WALL AT 48" O.C.
2X4 SOFFIT FRAMING
AT16" O.C.
1"
3/4" WOOD VENEERED
PLYWOOD UPPER CABINET
AND DOOR
1'-0"
RECESSED KV STANDARDS W/
ADJUSTABLE METAL SHELF
CLIPS
3/4" WOOD VENEERED
PLYWOOD ADJUSTABLE SHELF
3/4" WOOD VENEERED
PLYWOOD CABINET AND DOOR
BASE, RE: ROOM FINISH
SCHEDULE
GPDW CEILING
5/8" TYPE 'X' GPDW, PAINT
BRACE TO WALL AT 48" O.C.
2X4 SOFFIT FRAMING AT
16" O.C.
3/4" WOOD VENEERED
PLYWOOD CABINET AND DOOR
EXISTING BOX-OUT
SOLID SURFACE COUNTER
1'-2 1/2"
2' -1
1/
2"
1/ 2"
2' -6
1'
-3
2X…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .