THP_Dispatch_Consoles_Specifications.docx

DOCX document 40 KB Posted

Attached to
THP Dispatch Consoles
Solicitation number
Event 34901-14041
Issued by
Davidson County, Tennessee

About this file

This is a detailed specifications document for console furniture and ergonomic chairs procurement issued by the Tennessee Highway Patrol (THP) Dispatch Division. The project encompasses the procurement, design, delivery, installation, and commissioning of 32 complete dispatch workstations and 32 ergonomic dispatch chairs to be allocated across four THP dispatch centers: Jackson (10 workstations), Nashville (10 workstations), Chattanooga (6 workstations), and Knoxville (6 workstations). Each workstation must be designed for continuous 24/7 emergency communications operations and include a console with integrated cable and power management, motorized height-adjustable work surfaces, monitor support systems accommodating five 24-inch displays, integrated storage, and one ergonomic chair. The specifications establish minimum requirements for modular construction, ergonomic compliance with ANSI, BIFMA, ISO guidance and ADA accessibility standards, field verification and survey, design deliverables including to-scale floor plans and CAD drawings, mock-up capability, and final acceptance documentation.

The vendor must provide comprehensive cost proposals covering all 32 complete console workstations with specified components, 32 ergonomic dispatch chairs, design and engineering services including field surveys and CAD drawings, mock-ups if required, delivery and installation to all four centers, training and documentation, and an emergency parts kit. The vendor bears all shipping, storage, delivery, installation, and debris removal costs and must employ factory installers or authorized trained designees experienced in 911/emergency communications center installations. Warranty requirements include lifetime or longest available coverage for fixed structural frames, minimum 10-year warranties for static panels and work surfaces, minimum 10-year warranties for adjustable mechanisms including on-site service, and priority-based service with repairs beginning within 24 hours. No set-asides, funding sources, pricing terms, or contract term information is specified in this specifications document.

View the file

Other files

File Type Posted
34901-14041_Terms_and_Conditions.docx DOCX document
THP_Dispatch_Consoles.pdf PDF
34901-14041_Site_Visit_Information.docx DOCX document
Survey_Document.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THP Dispatch Division Detailed Specifications for Console Furniture and Ergonomic Chairs Procurement quantity: 32 complete dispatch workstations and 32 ergonomic dispatch chairs Prepared for the Tennessee Highway Patrol Dispatch Division 1 Purpose and Scope These specifications establish the minimum requirements for furnishing, delivering, installing, commissioning, and supporting 32 dispatch workstations for the Tennessee Highway Patrol. Each workstation shall include a 24/7 emergency communications console, equipment accommodations, cable and power management, monitor support, integrated storage, and one ergonomic chair.

2 Workstation Quantity and Center Allocation The controlling quantity is 32 workstations. The source document contains a conflicting reference to 40 workstations; that reference is superseded by this requirement. Room allocations shall be confirmed during the site survey and final design.

Dispatch center
Workstations
Room size provided in source
Jackson
10
60 ft 3 in × 20 ft
Nashville
10
48 ft × 24 ft
Chattanooga
6
28 ft × 21 ft
Knoxville
6
28 ft × 21 ft
Total
32
Verify by site survey

3 Vendor Submittals and Compliance Response The proposer shall provide a concise narrative and a completed compliance checklist for every requirement. Mark Yes only when the requirement is included, operational, and compliant at proposal submission. A No response shall identify the exception and its cost-sheet line item. No pricing shall appear in comments.

4 Console System Requirements

Item
Minimum requirement
Yes
No
Vendor comment / reference
4.1
Designed and warranted for continuous 24/7 operation in an emergency communications center.
☐
☐
4.2
Structural internal metal frame supports work surfaces, equipment storage, panels, valances, and cable management.
☐
☐
4.3
True modular construction; each module is stand-alone and supports future reconfiguration and expansion.
☐
☐
4.4
Supports single-sided and back-to-back configurations and reconfigurable angles.
☐
☐
4.5
Casework tolerance within 1/64 inch where specified; metal components within 0.020 inch.
☐
☐
4.6
Durable, uniform powder-coat finish over cleaned and rust-inhibitor-treated steel and aluminum; free of runs, wrinkles, grit, and roughness.
☐
☐
4.7
Smooth, radiused edges and transitions; no sharp edges, exposed hazards, or pinch points.
☐
☐
4.8
Meets applicable ANSI, BIFMA, ISO ergonomic guidance, ADA accessibility requirements, and applicable codes.
☐
☐
4.9
All equipment fits through 35-inch doors; vendor verifies delivery paths before fabrication.
☐
☐

5 Work Surface and Ergonomics

Item
Minimum requirement
Yes
No
Vendor comment / reference
5.1
Continuous seamless curved work surface with a dedicated contoured operator position.
☐
☐
5.2
Smooth edges and transitions without sharp corners, exposed seams, or pinch points.
☐
☐
5.3
Structural metal support and motorized height adjustment for seated and standing operation.
☐
☐
5.4
Height adjustment includes safety stop or anti-collision protection and a status indicator light per console.
☐
☐
5.5
Unobstructed knee and leg clearance for side-to-side movement and foot-pedal use.
☐
☐
5.6
One task light or desk lamp per console.
☐
☐
5.7
Minimum two mounted headset jacks per console with protected cable routing; final type and location approved in design.
☐
☐

6 Monitor Support and Equipment Accommodation

Item
Minimum requirement
Yes
No
Vendor comment / reference
6.1
One adjustable monitor tree per console supports at least five 24-inch monitors; preferred arrangement is two upper and three lower.
☐
☐
6.2
Displays are within comfortable reach and viewing angles and adjustable for operator height and posture.
☐
☐
6.3
Mounts provide at least three articulating movements and allow lift, rotation, raising, and lowering.
☐
☐
6.4
Pneumatic counterbalance adjustable for 7 to 22 pounds; VESA 75 mm and 100 mm patterns.
☐
☐
6.5
Vendor installs and adjusts all monitor mounts per approved configuration.
☐
☐
6.6
Each console accommodates five monitors, one desk phone, three keyboards, three mice, seven speakers, three CPUs, one Motorola console transmitter box or radio consolette, radio foot pedals, one Genovation keypad, and related hardware.
☐
☐

7 Structural Panels, Cable Management, and Storage

Item
Minimum requirement
Yes
No
Vendor comment / reference
7.1
Minimum three integrated horizontal and vertical cable channels through connected walls and bases.
☐
☐
7.2
Accessible front and rear cable-management panels; cables pass into base without drilling work-surface grommets.
☐
☐
7.3
Work-surface cable management permits independent equipment movement, protects travel cables, and passes finished connectors.
☐
☐
7.4
Protected, concealed, accessible vertical cable management and minimum one lateral raceway with option for more.
☐
☐
7.5
Durable finished panels and doors; quick-release or tool-less access where practical; concealed hinges or clips where feasible.
☐
☐
7.6
Integrated CPU and rack storage with front and rear access, ventilation, supplemental low-noise fan provisions, and airflow-promoting trays.
☐
☐
7.7
Fixed or slide-out rack shelves; full-extension trays/drawers support 250 pounds where specified and include interlock or counterbalance.
☐
☐
7.8
Front or rear access to electronic reset/power controls without crawling beneath console; hinged CPU doors.
☐
☐
7.9
One integrated personal storage compartment per console with at least two drawers; submit size options.
☐
☐
7.10
Full-extension precision ball-bearing drawer hardware rated at least 100 pounds per drawer.
☐
☐

8 Electrical and Data Requirements

Item
Minimum requirement
Yes
No
Vendor comment / reference
8.1
One dedicated critical-operations power bar per console, CSA or UL approved, 15-amp breaker, minimum seven outlets, and capacity for three transformer plugs per outlet.
☐
☐
8.2
Each bar includes minimum 10-foot cord, wiring-fault and protection-status indicators, catastrophic-event protection, and lightning/surge protection; locate near CPU cabinet.
☐
☐
8.3
Two dedicated workspace power bars per console, one on each side of monitor array, with the same approval, outlet, cord, indicator, and protection requirements.
☐
☐
8.4
Two separate double standard-power receptacles at wall locations approved in final design.
☐
☐
8.5
Minimum CAT6 eight-port patch panel at each console near CPU cabinet.
☐
☐
8.6
UL-approved wiring materials and workstation wiring diagram/equipment schematic for each configuration.
☐
☐
8.7
Protected radio foot-pedal and device cable routing that does not interfere with chair movement, height adjustment, or egress.
☐
☐

9 Ergonomic Chair Requirements

Item
Minimum requirement
Yes
No
Vendor comment / reference
9.1
Provide 32 heavy-duty ergonomic chairs designed for continuous dispatch-center use and compatible with console height range.
☐
☐
9.2
Each chair includes articulating headrest, fabric or cloth upholstery, pivoting arm, and partial ring or equivalent support feature.
☐
☐
9.3
Chair reclines, locks in place, and rocks; controls are accessible while seated.
☐
☐
9.4
Adjustable seat height, seat depth or equivalent, back support, arm height, and durable casters suitable for installed floor.
☐
☐
9.5
No sharp edges or pinch hazards; upholstery is cleanable and serviceable through warranty program.
☐
☐

10 Space Planning and Design Deliverables

Item
Minimum requirement
Yes
No
Vendor comment / reference
10.1
Field-verify each center, including dimensions, doors, columns, power, data, HVAC, life-safety equipment, pathways, and obstructions.
☐
☐
10.2
To-scale floor plan for each center showing all 32 consoles, chairs, equipment, aisles, clearances, access, wiring termination, and service zones.
☐
☐
10.3
To-scale perspectives and elevations for each console type with accessories and all height, width, and depth dimensions.
☐
☐
10.4
Photographs, CAD files, technical drawings, equipment elevations, and finish information verifying fit and compliance.
☐
☐
10.5
Measurements and storage plan for shipment materials associated with eight consoles.
☐
☐
10.6
State-approved final layouts, console configurations, wiring locations, aisles, equipment placement, and materials before fabrication.
☐
☐
10.7
Color and material board using standard manufacturer offerings for State review and approval.
☐
☐

11 Delivery, Mock-Up, Installation, and Acceptance

Item
Minimum requirement
Yes
No
Vendor comment / reference
11.1
State best lead time for design, approval, fabrication, shipping, delivery, and installation; deliver on time to each center.
☐
☐
11.2
Vendor bears shipping, storage, delivery, installation, debris removal, and related costs.
☐
☐
11.3
Provide a fully functional mock-up if requested; State may approve, reject, or require corrections before full fabrication.
☐
☐
11.4
Written implementation plan and one project manager as single point of contact; attend coordination meetings as requested.
☐
☐
11.5
Meet approved schedule and provide sufficient trained manpower, including extended hours when needed.
☐
☐
11.6
Factory installers or trained authorized designees experienced in 911/emergency communications centers perform installation.
☐
☐
11.7
Protect building and contents, maintain safe work area, remove trash daily, and leave area broom-clean or vacuumed.
☐
☐
11.8
Conduct final walk-through; correct discrepancies from approved drawings, specifications, materials, or workmanship before acceptance.
☐
☐

12 Warranty, Maintenance, and Service

Item
Minimum requirement
Yes
No
Vendor comment / reference
12.1
State warranty period for every console component, chair component, mechanism, finish, and accessory.
☐
☐
12.2
Lifetime or longest available warranty for fixed structural frames; minimum 10 years for static panels and work surfaces.
☐
☐
12.3
Minimum 10 years for adjustable, sliding, hinged, and height-adjustment mechanisms, including on-site service.
☐
☐
12.4
Priority-based service plan; begin warranty repairs within 24 hours and continue until workstation is functional.
☐
☐
12.5
On-site emergency parts kit for major components with delivery exceeding 24 hours; identify contents and replenishment.
☐
☐
12.6
Single point of contact; provide service program, escalation procedure, preventive maintenance guidance, and service records.
☐
☐

13 Cost Proposal Line Items

Item
Minimum requirement
Yes
No
Vendor comment / reference
13.1
32 complete console workstations with all specified frames, surfaces, monitor trees, panels, cable management, storage, power, data, lights, and accessories.
☐
☐
13.2
32 ergonomic dispatch chairs.
☐
☐
13.3
Design, field survey, CAD drawings, floor plans, perspectives, schematics, and as-builts.
☐
☐
13.4
Mock-up, if required.
☐
☐
13.5
Shipping, delivery, storage, installation, commissioning, testing, and acceptance walk-through.
☐
☐
13.6
Training, manuals, warranty documents, spare parts, and emergency parts kit.
☐
☐
13.7
Removal/recycling of packaging and separately priced exceptions or options.
☐
☐

14 Final Acceptance Documentation At final acceptance, provide as-built floor plans, elevations, equipment and wiring schematics, product data sheets, approved finish selections, serial-number inventory, warranty certificates, maintenance contacts, service procedures, training records, and a list of approved deviations.