This is a blank Schedule B spreadsheet template containing detailed insulation specifications for the USCGC THETIS repair work. The file lists various types of insulation requirements for ducts, pipes, compartments, and machinery exhaust systems, including specific material standards like MIL-I-742, MIL-I-22023, and MIL-P-15280. It references multiple ship drawings and specifications for different systems including ventilation ducts, chill water, hot water, and machinery spaces.

The related solicitation is for repair work on the USCGC THETIS, issued as a total small business set-aside under NAICS 336611. Work is to be performed at 100 Trumbo Road, Key West FL between March 4-10, 2025. Quotes are due by March 3, 2025 at 12:00 PM EST. The contract will be awarded as firm-fixed price using simplified acquisition procedures to the lowest price technically acceptable offer. Vendors must be registered in SAM.gov and submit quotes via email to the listed contracting officers.

View the file

Other files

File Type Posted
THETIS Repairs - SOW.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG BOM REFs Duct Size Thermal (board), 1" THK, Type II, 3# Density, MIL-I-742 TY II (SQ-FT) tefrownfelter: For supply duct 9-1/2" and larger.

Thermal (blanket), 1" THK, Type I, 2# Density, MIL-I-22023 (SQ-FT) tefrownfelter: For supply duct 9" and smaller.

Vent Duct Insulation, Machinery Spaces8-1/2" - 12"901 WMEC 513-003, Rev. GVENT AUX MCHRY SP NO 2 - A&D
Machinery Spaces12-1/8" - 18"N/A
18-1/2" - 30"N/A
over 30"N/A
Non-Machinery Spaces901 WMEC 514-003, Rev. CINSULATION VENT DUCTS
Pipe Insulation
SYSTEMPipe Size, IPS (in)Thermal, Elastomeric/ Formed - 72" long, MIL-P-15280Closed-cell Nitrile/ PVC, UNSLIT Tubing - 72" long, MIL-P-15280
Chill Water & Hot Water - Machinery Space2"N/A618 WMEC 514-002, Rev. GARRGMT OF CHILL & HOT WATER SYSTEM INSIDE MS
3/4"
Pipe Insulation
SYSTEMPipe Size, IPS (in)Thermal, Fiberous Glass, MIL-C-20079 Type III GR "F"FIBERFRAX Ceramic Fiber Insulation

ELEX Cooling System All N/A 901 WMEC 508-001, Rev. D PIPE & MCHRY INSUL SCHEDULE

Potable Water System3/8N/A
1/2N/A
3/4N/A
1N/A
1-1/4N/A
1-1/2N/A
2N/A
3N/A
Sea Water and Foam Solution4N/A
Lube Oil System2-1/2N/A
Waste Heat Recovery1/2N/A
1N/A
1-1/4N/A
1-1/2N/A
3N/A
4N/A
6N/A
Chilled Water and Hot Water3/8N/A
1/2N/A
3/4N/A
1N/A
1-1/4N/A
1-1/2N/A
2N/A
2-1/2N/A
3N/A
3-1/2N/A
Comp Air Machinery Space3/4N/A
Diesel Exhaust8N/A
12N/A
20N/A
Sea Water Cooling1N/A
1-1/2N/A
2N/A
2-1/2N/A
3N/A
3-1/2N/A
4N/A
5N/A
6N/A
Firemain1/2N/A
3/4N/A
2-1/2N/A
3N/A
4N/A
6N/A
Distilling Plant (OBSOLETE??)1/2N/A
1-1/4N/A
3N/A
Compartment (Hull & Bulkhead) Insulation
Thermal Blanket Insulation, 1" THK,Fiberglass Felt, MIL-I-22023C, Type I, Class C901 WMEC 635-001, Rev. KHULL THERMAL & ACOUSTIC INSULATION A/DEng. Compt. - Depot Level
Thermal Blanket Insulation, 2" THK,Non-Eng. Compt. - Org. Level
Thermal Board Insulation, 1" THKFiberglass, Cloth Faced, MIL-I-742D, Type I
Thermal Board Insulation, 2" THK
Acoustic Blanket Insulation, 2" THK,Fiberglass Felt, SND Absorbing, MIL-I-22023C, Type II, Class 3
Acoustic Board Insulation, 1" THKFiberglass Felt, Cloth Faced, MIL-A-23054, Perforated
Acouostic Board Insulation, 2" THK
Machinery Exhaust Stack Insulation (Preformed, Hydrous Calcium Silicate, Molded, Split Round)6"618 WMEC 259-001, Rev. F (BOM)
8"
12"
18"
Machinery Exhaust Blankets

Datasheet

USCG NAVAL ENGINEERING MANUAL (NEM) INSULATION SPECIFICATIONS
(COMNDINST M9000.6E DTD 10/21/04)
Authorized Insulation Materials for Use Aboard Coast Guard Cutters **
ITEMDESCRIPTION / APPLICATIONSTD
1Thermal Insulation for Piping-
1.1Pre-formed Pipe Covering-
1.1.1Thermal InsulationMIL-I-2781
1.1.2Anti-Sweat InsulationEBC SPEC 4013
1.1.3Elastomeric Foam Plastic, Unicellular (Form T), TubularMIL-P-15280
1.1.4Preformed Fiberous Glass Pipe CoveringMIL-I-22344
1.2Thermal Insulation BlockMIL-I-2781
1.3Blanket, Sheets, and Felts-
1.3.1Thermal Glass Fiber Insulation FeltMIL-I-16411
1.3.2Insulation Blanket, Thermal Fiberous MineralMIL-I-2818
1.3.3Plastic Foam, Unicellular (Form S), Sheet Form, ElastomericMIL-P-15280
1.3.4Sheet Form Polyimide Foam InsulationDOD-I-24688
1.3.5Anti-Sweat Insulation, Sheet FormEBC SPEC 4013
1.3.6Polyphosphazene Elastomeric Foam InsulationMIL-I-24703
2Diesel Exhaust Insulation
3Thermal Insulation for Machinery-
3.1Blanket, Sheets, and Felts-
3.1.1Insulation Blanket, Thermal Fiberous MineralMIL-I-2818
3.1.2Anti-Sweat InsulationEBC SPEC 4013
3.1.3Insulation Felt, Thermal, Glass FiberMIL-I-16411
3.1.4Insulation Felt, Thermal and Sound Absorbing Felt, Fiberous Glass, 370 Deg. F MaximumMIL-I-22023
3.1.5Polyimide FoamDOD-I-24688, Type I
3.2Insulation Block, ThermalMIL-I-2819
4Thermal Insulation for Compartments-
4.1Fiberous Glass Faced Thermal Insulation BoardMIL-I-742, Type I
4.2Fiberous Glass Unfaced Thermal FeltMIL-I-22023, Type I, Class 6
4.3Fiberous Glass Faced Thermal and Sound Absorbing FeltMIL-I-22023, Type III
4.4Sheathing, Consisting of Perforated AluminumMIL-S-12875
4.5Elastomeric FoamMIL-P-15280, Form S
4.6Polyimide Foam Faced Thermal Insulation PanelDOD-I-24688, Type II, Class I
5Thermal Insulation for Ducts-
5.1Round or Flat Oval Ducts-
5.1.1Fiberous Glass Insulation Felt, 1" THKMIL-I-22023, Type I, Class 5
5.1.2Polyimide Foam, 1" THKDOD-I-24688
5.2Square or Rectangular Ducts-
5.2.1Fiberous Glass Insulation Board, 1" THKMIL-I-742, Type I or II
5.2.2Thermal and Acoustic Insulation with Vapor Barrier, 1" THKMIL-I-22023, Type III

** NOTE: NSTM Chapter 635, Rev. 2 lists MIL-STD-1623 and NSTM Chapter 635, Rev. 2 for insulation selection guidence. The above table is summary of these aforementioned reference documents.

NSTM

NSTM Chapter 635, Rev. 2 - July 1998
Section 2 - Thermal Insulation for PipingMIL-STD-769
Preformed Pipe Covering
1)Thermal InsulationMIL-I-27811/2" - 1-1/2"2" - 2-1/2"3" - 4-1/2"5" - 7"8" and larger
2)Anti-Sweat InsulationEBC Spec 40131/2"1/2" - 3/4"3/4" - 1"1"1-1/2"<Insulation Thickness
3)Elastomeric Foam Plastic, Unicellular (Form T), TubularMIL-P-15280
4)Preformed Fiberous Glass Pipe CoveringMIL-I-22344
5)Preformed Polyimide Foam Insulation for Hot Piping, Type I, Without Vapor BarrierDOD-I-246881/2"1/2" - 3/4"3/4" - 1"1"1-1/2"<Insulation Thickness
6)Polyphosphazene Elastomeric Foam InsulationMIL-I-24703

Thermal Insulation Block MIL-I-2819 1-1/2" 2" 2-1/2" 4" 5" 5-1/2" 6-1/2"

Blanket, Sheets, and Felts
1)Thermal Glass Fiber Insulation FeltMIL-I-164111"1-1/2"2"3"4"4-1/2"5"6"
2)Insulation Blanket, Thermal Fiberous MineralMIL-I-2818
3)Plastic Foam, Unicellular (Form S), Sheet Form, ElastomericMIL-P-15280
4)Sheet Form Polyimide Foam InsulationDOD-I-246881/2"3/4"1"1-1/2"<Thickness
5)Anti-Sweat Insulation, Sheet FormEBC Spec 40131/2"1/2" - 3/4"3/4" - 1"1"1-1/2"<Insulation Thickness
6)Polyphosphazene Elastomeric Foam InsulationMIL-I-24703

Diesel Exhaust Insulation MIL-STD-769

Section 3 - Thermal Insulation for Machinery

Blanket, Sheets, and Felts
1)Insulation Blanket, Thermal Fiberous MineralMIL-I-2818
2)Anti-Sweat InsulationEBC Spec 4013 (or can use MIL-I-22023, Class 6 for cold water piping)
3)Insulation Felt, Thermal, Glass FiberMIL-I-16411
4)Insulation Felt, Thermal and Sound Absorbing Felt, Fiberous Glass, 370 Deg. F MaximumMIL-I-22023
5)Polyimide FoamDOD-I-24688, Type I

Insulation Block, Thermal MIL-I-2819, Classes II and III.

Section 4 - Refrigerated Stores Spaces MIL-I-24172

Section 5 - Thermal Insulation for Compartments1" THK2" THK
1)Fiberous Glass Faced Thermal Insulation BoardMIL-I-742, Type 1
2)Fiberous Glass Unfaced Thermal FeltMIL-I-22023, Type I, Class 6
3)Fiberous Glass Faced Thermal and Sound Absorbing FeltMIL-I-22023, Type III
4)Sheathing, Consisting of Perforated AluminumMIL-S-12875, Type II, Class B
5)Elastomeric FoamMIL-P-15280, Form S
6)Polyimide Foam Faced Thermal Insulation PanelDOD-I-24688, Type II, Class I

Section 6 - Thermal Insulation for Ducts

Round or Flat Oval Ducts
1)Fiberous Glass Insulation Felt, 1" THKMIL-I-22023, Type I, Class 5
2)Polyimide Foam, 1" THKDOD-I-24688
Square or Rectangular Ducts
1)Fiberous Glass Insulation Board, 1" THKMIL-I-742, Type I or IIFaced vs. Unfaced??
2)Thermal and Acoustic Insulation with Vapor Barrier, 1" THKMIL-I-22023, Type IIIFaced vs. Unfaced??

Section 7 - Acoustic Absorption Treatment and Transmission Loss Treatment for Compartments

1)Fiberous Glass Acoustical Board, Perforated, Hard Surfaced, 2" THKMIL-A-23054
2)Fiberous Glass Acoustical Felt, FacedMIL-I-22023, TYPE III
3)Acoustic Fire InsulationNAVSEA Drawing 803-5184182
4)Vinyl Sheet, Barium Sulfate-LoadedMIL-A-24699
5)Polyimide Foam, Thermal and Acoustic InsulationDOD-I-24688
NOTES:a) For Machinery Spaces: Fiberous Glass Thermal and Sound Absorbing Felt conforming to MIL-I-22023, Type III.
b) For dry environments, outside of machinery spaces: Perforated acooustical board conforming to MIL-A-23054
or DOD-I-24688, Type II, Class 2.

Section 8 - Acoustic Lining and Lagging for Ducts

Round or Flat Oval Ducts
1)Fiberous Glass Blanket, Acoustic LiningMIL-I-22023
2)Polyimide Foam PanelDOD-I-24688
Square or Rectangular Ducts
1)Fiberous Glass BlanketMIL-I-22023
2)Fiberous Glass Acoustical Absorbtion Board, Perforated, Hard SurfaceMIL-A-23054
3)Polyimide Foam PanelDOD-I-24688
Section 9 - Fire Insulation for Compartments
1)Fire Insulation - Thermal Ceramics Structo-GardR FB, Imi-Tech SOLIMIDE TM Firesafe, or equal.
2)Thermal Fire Insulation - Fire Insulation w/ Fiberous Glass Cloth Facing in conformance with MIL-I-742, Type I.
3)Acoustic Absorptive Treatment - Fire insulation w/ a fiberous glass waffle sheet and a perforated glass cloth facing in
conformance w/ MIL-A-23054.
4)Fiberous Glass Insulation FeltMIL-I-22023, Type II, Class 6.
5)Transmission Loss TreatmentNAVSEA Drawing 803-5184182
6)Sheathing w/ Solid or Perforated AluminumMIL-S-12875, Type II, Class B.

MIL-STD-1623

MIL-STD-1623E (NAVY) w. CHANGE 1, 19 April 2010
(Authorized Matls. Per NEM Chapter 635 DTD 10/21/04)
1)Insulating BoardMIL-I-742 Type I (faced board)
Type I (core only)
Type II (unfaced board)
2)Pipe InsulationMIL-I-2781
MIL-PRF-22344
3)Anti-Sweat Pipe InsulationEB Corp Spec 4013
4)Block InsulationMIL-PRF-2819
5)Insulating FeltMIL-I-16411
6)Insulating BlanketSee Note 21. Std product not available.
7)On-deck InsulationSee Note 22. Std product not available.
8)Glass ClothMIL-C-20079
Type I, Classes 1,3,5,7, and 9
Type I, Class II
Type I, Classes 4,6,8, and 10
Type II, Classes 1,3, and 4
Type II, Class II
9)Cellular Foam (Reefer spaces only)MIL-PRF-24172
10)End SealerMIL-C-22395
11)Thermal/Sound Absorbing FeltMIL-I-22023, Type I and Type II
12)Thermal/Accoustic PanelDOD-I-24688, Type I
Type II, Class 1 and 2
13)High Temperature Fire/Thermal/Acoustic InsulationMIL-PRF-32161, Type I, II, and III
Type I
14)Thermal/Acoustic BarrierMIL-T-24708, Type I
Type I, Class 3
15)Acoustic BoardMIL-A-23054

DWG BOM

Duct Size Thermal (board), 1" THK, Type II, 3# Density, MIL-I-742 TY II (SQ-FT) Thermal (blanket), 1" THK, Type I, 2# Density, MIL-I-22023 (SQ-FT)

Vent Duct Insulation, Machinery Spaces8-1/2" - 12"901 WMEC 513-003, Rev. GVENT AUX MCHRY SP NO 2 - A&D
Machinery Spaces12-1/8" - 18"N/A
18-1/2" - 30"N/A
over 30"N/A
Non-Machinery Spaces901 WMEC 514-003, Rev. CINSULATION VENT DUCTS
Pipe Insulation
SYSTEMPipe Size, IPS (in)Thermal, Elastomeric/ Formed - 72" long, MIL-P-15280Closed-cell Nitrile/ PVC, UNSLIT Tubing - 72" long, MIL-P-15280

NOTE: Per NSTM MIL-P-15280 is NOT approved for new construction and is only listed because of it's presence on older ships. DO NOT USE FOR REPAIRS! See Electric Boat Corp. Spec 4013 for replacement material.

Chill Water & Hot Water - Machinery Space2"N/A618 WMEC 514-002, Rev. GARRGMT OF CHILL & HOT WATER SYSTEM INSIDE MS
3/4"
Pipe Insulation
SYSTEMPipe Size, IPS (in)Thermal, Fiberous Glass, MIL-C-20079 Type III GR "F"FIBERFRAX Ceramic Fiber Insulation???

ELEX Cooling System All N/A 901 WMEC 508-001, Rev. D PIPE & MCHRY INSUL SCHEDULE

Potable Water System3/8N/A
1/2N/A
3/4N/A
1N/A
1-1/4N/A
1-1/2N/A
2N/A
3N/A
Sea Water and Foam Solution4N/A
Lube Oil System2-1/2N/A
Waste Heat Recovery1/2N/A
1N/A
1-1/4N/A
1-1/2N/A
3N/A
4N/A
6N/A
Chilled Water and Hot Water3/8N/A
1/2N/A
3/4N/A
1N/A
1-1/4N/A
1-1/2N/A
2N/A
2-1/2N/A
3N/A
3-1/2N/A
Comp Air Machinery Space3/4N/A
Diesel Exhaust8N/A
12N/A
20N/A
Sea Water Cooling1N/A
1-1/2N/A
2N/A
2-1/2N/A
3N/A
3-1/2N/A
4N/A
5N/A
6N/A
Firemain1/2N/A
3/4N/A
2-1/2N/A
3N/A
4N/A
6N/A
Distilling Plant (OBSOLETE??)1/2N/A
1-1/4N/A
3N/A
Compartment (Hull & Bulkhead) Insulation
Thermal Blanket Insulation, 1" THKFiberglass Felt, MIL-I-22023C, Type I, Class C901 WMEC 635-001, Rev. KHULL THERMAL & ACOUSTIC INSULATION A/DEng. Compt. - Depot Level
Thermal Blanket Insulation, 2" THKNon-Eng. Compt. - Org. Level
Thermal Board Insulation, 1" THKFiberglass, Cloth Faced, MIL-I-742D, Type I
Thermal Board Insulation, 2" THK
Acoustic Blanket Insulation, 2" THK,Fiberglass Felt, SND Absorbing, MIL-I-22023C, Type II, Class 3
Acoustic Board Insulation, 1" THKFiberglass Felt, Cloth Faced, MIL-A-23054, Perforated
Acouostic Board Insulation, 2" THK
Machinery Exhaust Stack Insulation (Preformed, Hydrous Calcium Silicate, Molded, Split Round)6"618 WMEC 259-001, Rev. F (BOM)
8"
12"
18"
Machinery Exhaust Blankets
Fiberglass Felt, Cloth Faced, MIL-A-23054, Perforated

WMEC 210-270 Fleet

ACTIVE618Port AngelesWAA
ALERT630WarrentonORB
STEADFAST623WarrentonORB
CONFIDENCE619Cape CanaveralFLA
VIGILANT617Cape CanaveralFLA
RESOLUTE620St. PetersburgFLB
VENTUROUS625St. PetersburgFLB
VALIANT621Miami BeachFLB
MOHAWK913Key WestFLB
THETIS910Key WestFLB
DEPENDABLE626Cape MayNJB
VIROROUS627Cape MayNJB
DAUNTLESS624GalvestonTXB
DECISIVE629PascagoulaMSB
DILIGENCE616WilmingtonNCA
BEAR901PortsmouthVAA
FORWARD911PortsmouthVAB
HARRIET LANE903PortsmouthVAA
LEGARE912PortsmouthVAB
NORTHLAND904PortsmouthVAA
TAMPA912PortsmouthVAA
RELIANCE615PortsmouthNHA
CAMPBELL909KitteryMEB
TAHOMA908KitteryMEB
ESCANABA907BostonMAB
SENECA906BostonMAB
SPENCER905BostonMAB

Summary

SCHEDULE OF SUPPLIES & SERVICES (SOS&S)
US COAST GUARD WMEC 210 & 270 "A and B CLASS" MEDIUM ENDURANCE CUTTERS
IDIQ FOR INSULATION REPAIRS - PROJECT SUMMARY
ITEMDESCRIPTIONINSULATION SYSTEMINSTALLATION REF. DOC.INSULATION THICKNESS (in.)UNITYEAR 1 EST QTYLaborMatls.YEAR 2 EST QTYYEAR 3 EST QTYYEAR 4 EST QTYYEAR 5 EST QTY
1PIPING INSULATION, RENEW
1.1Air Conditioned Spaces
1.1.1Pre-formed Anti-Sweat Elastomeric Foam (Non-Halogen Only)6 LF / MHR$51 - $102 per 6 LFLabor Rate ($/HR)Labor + MatlsSet-Up / Misc

tefrownfelter: 25% add-in.

1.1.1.1 3/8" - 2" NPS EB Spec 4013 ASTM F683 tefrownfelter: ASTM F683 Refs. ASTM C534 Type II only.

1/2"6 LF1001$ 51$ 51$ 102.00$ 38.25100100100100
1.1.1.22-1/2" - 4" NPS""1/2"6 LF501$ 51$ 51$ 102.00$ 38.2550505050
1.1.1.34-1/2" - 6" NPS""1/2"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.1.46-1/2 " - 8" NPS""1/2"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.1.53/8" - 2" NPS""1"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.1.62-1/2" - 4" NPS""1"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.1.74-1/2" - 6" NPS""1"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.1.86-1/2 " - 8" NPS""1"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.2Pre-formed Fiberglass Pipe Insulation (1" Max. NPS applications only)$105 - $175 per 20 LF
1.1.2.13/8" NPSMIL-PRF-22344NAVSEA DWG 5959214 / ASTM F6831/2"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.2.21/2" NPS""1/2"6 LF101$ 51$ 51$ 102.00$ 38.2510101010
1.1.2.33/4" NPS""1/2"6 LF101$ 51$ 51$ 102.00$ 38.2510101010
1.1.2.41" NPS""1/2"6 LF101$ 51$ 51$ 102.00$ 38.2510101010
1.1.2.51" NPS""3/4"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.2.61" NPS""1"6 LF11$ 51$ 51$ 102.00$ 38.251111
1.1.3Sheet Form Anti-Sweat Insulation (Non-Halogen Only)Issue: 12 SQ FT

tefrownfelter: 1/2" = $25 / 1" = $42.

36" x 48" sheet.

1.1.3.13/8" - 2" NPSEB Spec 4013ASTM F6831/2"6 LF51$ 51.00$ 51$ 102.0038.255555
1.1.3.22-1/2" - 4" NPS""1/2"6 LF51$ 51.00$ 51$ 102.0038.255555
1.1.3.34-1/2" - 6" NPS""1/2"6 LF11$ 51.00$ 51$ 102.0038.251111
1.1.3.46-1/2 " - 8" NPS""1/2"6 LF11$ 51.00$ 51$ 102.0038.251111
1.1.3.53/8" - 2" NPS""1"6 LF11$ 51.00$ 51$ 102.0038.251111
1.1.3.62-1/2" - 4" NPS""1"6 LF11$ 51.00$ 51$ 102.0038.251111
1.1.3.74-1/2" - 6" NPS""1"6 LF11$ 51.00$ 51$ 102.0038.251111
1.1.3.86-1/2 " - 8" NPS""1"6 LF11$ 51.00$ 51$ 102.0038.251111
1.2Non-Air Conditioned Spaces
1.2.1Pre-formed Anti-Sweat Elastomeric Foam (Non-Halogen Only)
1.2.1.13/8" - 2" NPSEB Spec 4013ASTM F6833/4"6 LF1001$ 51.00$ 51$ 102.00$ 38.25100100100100
1.2.1.22-1/2" - 4" NPS""3/4"6 LF1001$ 51.00$ 51$ 102.00$ 38.25100100100100
1.2.1.34-1/2" - 6" NPS""3/4"6 LF501$ 51.00$ 51$ 102.00$ 38.2550505050
1.2.1.46-1/2 " - 8" NPS (8" Max. for application)""3/4"6 LF11$ 51.00$ 51$ 102.00$ 38.251111
1.2.1.53/8" - 2" NPS""2"6 LF201$ 51.00$ 51$ 102.00$ 38.2520202020
1.2.1.62-1/2" - 4" NPS""2"6 LF201$ 51.00$ 51$ 102.00$ 38.2520202020
1.2.1.74-1/2" - 6" NPS""2"6 LF11$ 51.00$ 51$ 102.00$ 38.251111
1.2.1.86-1/2 " - 8" NPS (8" Max. for application)""2"6 LF11$ 51.00$ 51$ 102.00$ 38.251111
1.2.2Pre-formed Fiberglass Pipe Insulation (1" Max. NPS applications only)up to 370 deg. F
1.2.2.13/8" NPSMIL-PRF-22344NAVSEA DWG 5959214 / ASTM F6831/2"6 LF10151$ 51$ 102.00$ 38.2510101010
1.2.2.21/2" NPS""3/4"6 LF10151$ 51$ 102.00$ 38.2510101010
1.2.2.33/4" NPS""3/4"6 LF10151$ 51$ 102.00$ 38.2510101010
1.2.2.41" NPS""3/4"6 LF10151$ 51$ 102.00$ 38.2510101010
1.2.2.51/2" NPS""1"6 LF10151$ 51$ 102.00$ 38.2510101010
1.2.2.63/4" NPS""1"6 LF10151$ 51$ 102.00$ 38.2510101010
1.2.2.71" NPS""1"6 LF10151$ 51$ 102.00$ 38.2510101010
1.2.3Sheet Form Anti-Sweat Insulation (Non-Halogen Only)
1.2.3.13/8" - 2" NPSEB Spec 4013ASTM F6833/4"6 LF201$ 51.00$ 51$ 102.00$ 38.2520202020
1.2.3.22-1/2" - 4" NPS""3/4"6 LF201$ 51.00$ 51$ 102.00$ 38.2520202020
1.2.3.34-1/2" - 6" NPS""3/4"6 LF101$ 51.00$ 51$ 102.00$ 38.2510101010
1.2.3.46-1/2 " - 8" NPS""3/4"6 LF101$ 51.00$ 51$ 102.00$ 38.2510101010
1.2.3.53/8" - 2" NPS""2"6 LF11$ 51.00$ 51$ 102.00$ 38.251111
1.2.3.62-1/2" - 4" NPS""2"6 LF11$ 51.00$ 51$ 102.00$ 38.251111
1.2.3.74-1/2" - 6" NPS""2"6 LF11$ 51.00$ 51$ 102.00$ 38.251111
1.2.3.86-1/2 " - 8" NPS""2"6 LF11$ 51.00$ 51$ 102.00$ 38.251111
2DIESEL EXHAUST INSULATION, RENEW
2.1Pre-formed Exhaust Pipe Insulation - Hard, Non-Removable
2.1.13" - 4-1/2" NPSMIL-I-2781FASTM F6834-1/2"6 LF1151$ 51$ 102.00$ 38.251111
2.1.25" - 7-1/2" NPS""5-/12"6 LF1151$ 51$ 102.00$ 38.251111
2.1.38" or Larger NPS""6"6 LF1151$ 51$ 102.00$ 38.251111
2.2Exhaust Pipe Insulation - Removable Blankets (pads)
2.2.11-1/2" - 2" NPSMIL-I-16411, Type IINAVSEA DWG 5959212 / ASTM F6833-1/2"10 SQ-FT1151$ 51$ 102.00$ 38.251111
2.2.23" NPS""4"10 SQ-FT5151$ 51$ 102.00$ 38.255555
2.2.34" - 5-1/2" NPS""4-1/2"10 SQ-FT5151$ 51$ 102.00$ 38.255555
2.2.46" - 8" NPS""5"10 SQ-FT5151$ 51$ 102.00$ 38.255555
2.2.5Larger than 8" NPS""5"10 SQ-FT5151$ 51$ 102.00$ 38.255555
3COMPARTMENT INSULATION, RENEW
3.1Air Conditioned Spaces
3.1.1Fiberous Glass Cloth-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type INAVSEA DWG 57739323/4"10 SQ-FT51515110238.255555
3.1.1.1"""1"10 SQ-FT51515110238.255555
3.1.1.2" - w/ lamination.""2"10 SQ-FT11515110238.251111
3.1.1.3" - without lamination.""2"10 SQ-FT11515110238.251111
3.1.2Fiberous Glass Un-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type IINAVSEA DWG 57739313/4"10 SQ-FT11515110238.251111
3.1.2.1"""1"10 SQ-FT101515110238.2510101010
3.1.2.2" - w/ lamination.""2"10 SQ-FT11515110238.251111
3.1.2.3" - without lamination.""2"10 SQ-FT51515110238.255555
3.1.3Fiberglass Thermal Insulation Blanket, Un-faced (Type I)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739311/210 SQ-FT51515110238.255555
3.1.3.1"""1"10 SQ-FT51515110238.255555
3.1.3.2"""1-1/2"10 SQ-FT51515110238.255555
3.1.3.3"""2"10 SQ-FT11515110238.251111
3.1.3.4"""2-1/2"10 SQ-FT11515110238.251111
3.1.3.5"""3"10 SQ-FT11515110238.251111
3.1.3.6"""3-1/2"10 SQ-FT11515110238.251111
3.1.3.7"""4"10 SQ-FT11515110238.251111
3.1.4Fiberglass Sound Absorbing Blanket, Unfaced (Type II)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739311/210 SQ-FT11515110238.251111
3.1.4.1"""1"10 SQ-FT11515110238.251111
3.1.4.2"""1-1/2"10 SQ-FT11515110238.251111
3.1.4.3"""2"10 SQ-FT11515110238.251111
3.1.4.4"""2-1/2"10 SQ-FT11515110238.251111
3.1.4.5"""3"10 SQ-FT11515110238.251111
3.1.4.6"""3-1/2"10 SQ-FT11515110238.251111
3.1.4.7"""4"10 SQ-FT11515110238.251111
3.1.5Fiberglass Thermal Insulation and Sound Absorbing Board (Type III)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739313/4"10 SQ-FT11515110238.251111
3.1.5.1"""1"10 SQ-FT51515110238.255555
3.1.5.2"""1-1/2"10 SQ-FT11515110238.251111
3.1.5.3"""2"10 SQ-FT51515110238.255555
3.1.6Fiberglass Acoustical Board, Perforated, Hard Surface (Hullboard)MIL-A-23054ANAVSEA DWG 57739311"10 SQ-FT101515110238.2510101010
3.1.6.1"""2"10 SQ-FT101515110238.2510101010
3.1.7Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6831/2"10 SQ-FT11515110238.251111
3.1.7.1"""1"10 SQ-FT11515110238.251111
3.2Non-Air Conditioned Spaces
3.2.1Fiberous Glass Cloth-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type INAVSEA DWG 57739323/4"10 SQ-FT51515110238.255555
3.2.1.1"""1"10 SQ-FT51515110238.255555
3.2.1.2" - w/ lamination.""2"10 SQ-FT51515110238.255555
3.2.1.3" - without lamination.""2"10 SQ-FT11515110238.251111
3.2.2Fiberous Glass Un-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type IINAVSEA DWG 57739313/4"10 SQ-FT11515110238.251111
3.2.2.1"""1"10 SQ-FT11515110238.251111
3.2.2.2" - w/ lamination.""2"10 SQ-FT11515110238.251111
3.2.2.3" - without lamination.""2"10 SQ-FT11515110238.251111
3.2.3Fiberglass Thermal Insulation Blanket, Unfaced (Type I)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739311/2"10 SQ-FT11515110238.251111
3.2.3.1"""1"10 SQ-FT51515110238.255555
3.2.3.2"""1-1/2"10 SQ-FT11515110238.251111
3.2.3.3"""2"10 SQ-FT51515110238.255555
3.2.3.4"""2-1/2"10 SQ-FT11515110238.251111
3.2.3.5"""3"10 SQ-FT51515110238.255555
3.2.3.6"""3-1/2"10 SQ-FT11515110238.251111
3.2.3.7"""4"10 SQ-FT11515110238.251111
3.2.4Fiberglass Sound Absorbing Blanket, Unfaced (Type II)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739311/2"10 SQ-FT11$ 51$ 51$ 102.00$ 38.251111
3.2.4.1"""1"10 SQ-FT51$ 51$ 51$ 102.00$ 38.255555
3.2.4.2"""1-1/2"10 SQ-FT11$ 51$ 51$ 102.00$ 38.251111
3.2.4.3"""2"10 SQ-FT51$ 51$ 51$ 102.00$ 38.255555
3.2.4.4"""2-1/2"10 SQ-FT11$ 51$ 51$ 102.00$ 38.251111
3.2.4.5"""3"10 SQ-FT51$ 51$ 51$ 102.00$ 38.255555
3.2.4.6"""3-1/2"10 SQ-FT11$ 51$ 51$ 102.00$ 38.251111
3.2.4.7"""4"10 SQ-FT11$ 51$ 51$ 102.00$ 38.251111
3.2.5Fiberglass Thermal Insulation and Sound Absorbing Board (Type III)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739313/4"10 SQ-FT11515110238.251111
3.2.5.1"""1"10 SQ-FT11515110238.251111
3.2.5.2"""1-1/2"10 SQ-FT11515110238.251111
3.2.5.6"""2"10 SQ-FT11515110238.251111
3.2.6Fiberglass Acoustical Board, Perforated, Hard Surface (Hullboard)MIL-A-23054ANAVSEA DWG 57739311"10 SQ-FT101515110238.2510101010
3.2.6.1"""2"10 SQ-FT101515110238.2510101010
3.2.7Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6833/4"10 SQ-FT11515110238.251111
3.2.7.1"""2"10 SQ-FT101515110238.251111
4VENTILATION DUCT INSULATION, RENEW
4.1Air Conditioned Spaces - Round or Flat Oval Ducts
4.1.1Fiberglass Thermal Insulation Blanket, Un-faced (Type I)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739321/2"10 SQ-FT11515110238.251111
4.1.1.1"""1"10 SQ-FT101515110238.2510101010
4.1.1.2"""1-1/2"10 SQ-FT11515110238.251111
4.1.1.3"""2"10 SQ-FT101515110238.2510101010
4.1.1.4"""2-1/2"10 SQ-FT11515110238.251111
4.1.1.5"""3"10 SQ-FT51515110238.255555
4.1.1.6"""3-1/2"10 SQ-FT11515110238.251111
4.1.1.7"""4"10 SQ-FT11515110238.251111
4.1.2Fiberglass Sound Absorbing Blanket, Unfaced (Type II)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 5773932-------
4.1.2.1"""1/2"10 SQ-FT11515110238.251111
4.1.2.2"""1"10 SQ-FT101515110238.2510101010
4.1.2.3"""1-1/2"10 SQ-FT11515110238.251111
4.1.2.4"""2"10 SQ-FT101515110238.2510101010
4.1.2.5"""2-1/2"10 SQ-FT11515110238.251111
4.1.2.6"""3"10 SQ-FT51515110238.255555
4.1.2.7"""3-1/2"10 SQ-FT11515110238.251111
4.1.2.8"""4"10 SQ-FT11515110238.251111
4.1.3Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6831/2"10 SQ-FT11515110238.251111
4.1.3.1"""1"10 SQ-FT11515110238.251111
4.2Air Conditioned Spaces - Square or Rectangular Ducts
4.2.1Fiberous Glass Cloth-Faced Board, Thermal InsulationMIL-I-742F, Type INAVSEA DWG 57739323/4"10 SQ-FT11515110238.251111
4.2.1.1"""1"10 SQ-FT101515110238.2510101010
4.2.1.2" - w/ lamination.""2"10 SQ-FT101515110238.2510101010
4.2.1.3" - without lamination.""2"10 SQ-FT11515110238.251111
4.2.2Fiberous Glass Un-Faced Board, Thermal InsulationMIL-I-742F, Type IINAVSEA DWG 57739313/4"10 SQ-FT11515110238.251111
4.2.2.1"""1"10 SQ-FT11515110238.251111
4.2.2.2" - w/ lamination.""2"10 SQ-FT11515110238.251111
4.2.2.3" - without lamination.""2"10 SQ-FT11515110238.251111
4.2.3Fiberglass Thermal Insulation and Sound Absorbing Board (Type III)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739323/4"10 SQ-FT11515110238.251111
4.2.3.1"""1"10 SQ-FT51515110238.255555
4.2.3.2"""1-1/2"10 SQ-FT11515110238.251111
4.2.3.3"""2"10 SQ-FT51515110238.255555
4.2.4Acoustic Absorptive Board, Fibrous Glass Perforated Fibrous Glass Cloth Faced (Perforated Hull Board)MIL-A-23054ANAVSEA DWG 57739321"10 SQ-FT201515110238.2520202020
4.2.4.1"""2"10 SQ-FT201515110238.2520202020
4.2.5Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6831/2"10 SQ-FT11515110238.251111
4.2.5.1"""1"10 SQ-FT11515110238.251111
4.3Non-Air Conditioned Spaces - Round or Flat Oval Ducts
4.3.1Fiberglass Thermal Insulation Blanket, Un-faced (Type I)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739321/2"10 SQ-FT11515110238.251111
4.3.1.1"""1"10 SQ-FT11515110238.251111
4.3.1.2"""1-1/2"10 SQ-FT201515110238.2520202020
4.3.1.3"""2"10 SQ-FT351515110238.2535353535
4.3.1.4"""2-1/2"10 SQ-FT201515110238.2520202020
4.3.1.5"""3"10 SQ-FT201515110238.2520202020
4.3.1.6"""3-1/2"10 SQ-FT11515110238.251111
4.3.1.7"""4"10 SQ-FT11515110238.251111
4.3.2Fiberglass Sound Absorbing Blanket, Unfaced (Type II)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739321/2"10 SQ-FT11515110238.251111
4.3.2.1"""1"10 SQ-FT11515110238.251111
4.3.2.2"""1-1/2"10 SQ-FT11515110238.251111
4.3.2.3"""2"10 SQ-FT51515110238.255555
4.3.2.4"""2-1/2"10 SQ-FT11515110238.251111
4.3.2.5"""3"10 SQ-FT51515110238.255555
4.3.2.6"""3-1/2"10 SQ-FT11515110238.251111
4.3.2.7"""4"10 SQ-FT11515110238.251111
4.3.3Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6833/4"10 SQ-FT11515110238.251111
4.3.3.1"""2"10 SQ-FT11515110238.251111
4.4Non-Air Conditioned Spaces - Square or Rectangular Ducts
4.4.1Fiberous Glass Cloth-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type INAVSEA DWG 57739323/4"10 SQ-FT11515110238.251111
4.4.1.1"""1"10 SQ-FT101515110238.2510101010
4.4.1.2" - w/ lamination.""2"10 SQ-FT201515110238.2520202020
4.4.1.3" - without lamination.""2"10 SQ-FT51515110238.255555
4.4.2Fiberous Glass Un-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type IINAVSEA DWG 57739313/4"10 SQ-FT11515110238.251111
4.4.2.1"""1"10 SQ-FT101515110238.2510101010
4.4.2.2" - w/ lamination.""2"10 SQ-FT201515110238.2520202020
4.4.2.3" - without lamination.""2"10 SQ-FT11515110238.251111

4.4.3 Fiberglass Thermal Insulation and Sound Absorbing Board (Type III) MIL-I-22023 tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM F683 Refs. ASTM C534 Type II only.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: 25% add-in.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739323/4"10 SQ-FT11515110238.251111
4.4.3.1"""1"10 SQ-FT51515110238.255555
4.4.3.2"""1-1/2"10 SQ-FT31515110238.253333
4.4.3.3"""2"10 SQ-FT51515110238.255555
4.4.4Acoustic Absorptive Board, Fibrous Glass Perforated Fibrous Glass Cloth Faced (Perforated Hull Board)MIL-A-23054ANAVSEA DWG 57739321"10 SQ-FT51515110238.255555
4.4.4.1"""2"10 SQ-FT51515110238.255555
4.4.5Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6833/4"10 SQ-FT51515110238.255555
4.4.5.1"""2"10 SQ-FT101515110238.2510101010
5PERFORM ULTRASONIC THICKNESS MEASUREMENTS - STEEL PLATEN/AN/AN/A50 Shots501515110238.2550505050
A-OComposite Labor RateN/AN/AN/AHoursERROR:#REF!1515110238.25ERROR:#REF!ERROR:#REF!ERROR:#REF!ERROR:#REF!
B-OGFP ReportN/AN/AN/AEA541515110238.2554545454
C-OTravel and Per DiemN/AN/AN/AJob461515110238.2527344038
Total Price by Year$ - 0$ 1$ 51$ 51$ 102$ 38ERROR:#REF!ERROR:#REF!ERROR:#REF!ERROR:#REF!
Grand Total Price (5-Year Project Cost) =ERROR:#REF!

&F &A -- Page &P of &N

SOS&S

SCHEDULE OF SUPPLIES & SERVICES (SOS&S)

CGC THETIS - REPAIRS

ITEMDescriptionUNIT PRICEUNITQTYEXTENDED PRICE
1Repair Anemometer Foundation & Optical AlignmentEA2$ - 0
2Renew VLA Deck Line Up LightEA1$ - 0
3Travel & Per DiemEA1$ - 0
Total Price$ - 0

&F &A - Page &P of &N

QTYs

SCHEDULE OF SUPPLIES & SERVICES (SOS&S)
US COAST GUARD WMEC 210 & 270 "A and B CLASS" MEDIUM ENDURANCE CUTTERS
IDIQ FOR INSULATION REPAIRS - SUMMARY
ITEMDESCRIPTIONINSULATION SYSTEMINSTALLATION REF. DOC.INSULATION THICKNESS (in.)UNITYEAR 1 EST QTYLaborMatls.YEAR 2 EST QTYYEAR 3 EST QTYYEAR 4 EST QTYYEAR 5 EST QTY
1PIPING INSULATION, RENEW
1.1Air Conditioned Spaces
1.1.1Pre-formed Anti-Sweat Elastomeric Foam (Non-Halogen Only)6 LF / MHR$51 - $102 per 6 LFLabor Rate ($/HR)Labor + MatlsSet-Up / Misc

tefrownfelter: 25% add-in.

1.1.1.1 3/8" - 2" NPS EB Spec 4013 ASTM F683 tefrownfelter: ASTM F683 Refs. ASTM C534 Type II only.

1/2"6 LF100100100100100
1.1.1.22-1/2" - 4" NPS""1/2"6 LF5050505050
1.1.1.34-1/2" - 6" NPS""1/2"6 LF11111
1.1.1.46-1/2 " - 8" NPS""1/2"6 LF11111
1.1.1.53/8" - 2" NPS""1"6 LF11111
1.1.1.62-1/2" - 4" NPS""1"6 LF11111
1.1.1.74-1/2" - 6" NPS""1"6 LF11111
1.1.1.86-1/2 " - 8" NPS""1"6 LF11111
1.1.2Pre-formed Fiberglass Pipe Insulation (1" Max. NPS applications only)$105 - $175 per 20 LF
1.1.2.13/8" NPSMIL-PRF-22344NAVSEA DWG 5959214 / ASTM F6831/2"6 LF11111
1.1.2.21/2" NPS""1/2"6 LF1010101010
1.1.2.33/4" NPS""1/2"6 LF1010101010
1.1.2.41" NPS""1/2"6 LF1010101010
1.1.2.51" NPS""3/4"6 LF11111
1.1.2.61" NPS""1"6 LF11111
1.1.3Sheet Form Anti-Sweat Insulation (Non-Halogen Only)Issue: 12 SQ FT

tefrownfelter: 1/2" = $25 / 1" = $42.

36" x 48" sheet.

1.1.3.13/8" - 2" NPSEB Spec 4013ASTM F6831/2"6 LF55555
1.1.3.22-1/2" - 4" NPS""1/2"6 LF55555
1.1.3.34-1/2" - 6" NPS""1/2"6 LF11111
1.1.3.46-1/2 " - 8" NPS""1/2"6 LF11111
1.1.3.53/8" - 2" NPS""1"6 LF11111
1.1.3.62-1/2" - 4" NPS""1"6 LF11111
1.1.3.74-1/2" - 6" NPS""1"6 LF11111
1.1.3.86-1/2 " - 8" NPS""1"6 LF11111
1.2Non-Air Conditioned Spaces
1.2.1Pre-formed Anti-Sweat Elastomeric Foam (Non-Halogen Only)
1.2.1.13/8" - 2" NPSEB Spec 4013ASTM F6833/4"6 LF100100100100100
1.2.1.22-1/2" - 4" NPS""3/4"6 LF100100100100100
1.2.1.34-1/2" - 6" NPS""3/4"6 LF5050505050
1.2.1.46-1/2 " - 8" NPS (8" Max. for application)""3/4"6 LF11111
1.2.1.53/8" - 2" NPS""2"6 LF2020202020
1.2.1.62-1/2" - 4" NPS""2"6 LF2020202020
1.2.1.74-1/2" - 6" NPS""2"6 LF11111
1.2.1.86-1/2 " - 8" NPS (8" Max. for application)""2"6 LF11111
1.2.2Pre-formed Fiberglass Pipe Insulation (1" Max. NPS applications only)up to 370 deg. F
1.2.2.13/8" NPSMIL-PRF-22344NAVSEA DWG 5959214 / ASTM F6831/2"6 LF1010101010
1.2.2.21/2" NPS""3/4"6 LF1010101010
1.2.2.33/4" NPS""3/4"6 LF1010101010
1.2.2.41" NPS""3/4"6 LF1010101010
1.2.2.51/2" NPS""1"6 LF1010101010
1.2.2.63/4" NPS""1"6 LF1010101010
1.2.2.71" NPS""1"6 LF1010101010
1.2.3Sheet Form Anti-Sweat Insulation (Non-Halogen Only)
1.2.3.13/8" - 2" NPSEB Spec 4013ASTM F6833/4"6 LF2020202020
1.2.3.22-1/2" - 4" NPS""3/4"6 LF2020202020
1.2.3.34-1/2" - 6" NPS""3/4"6 LF1010101010
1.2.3.46-1/2 " - 8" NPS""3/4"6 LF1010101010
1.2.3.53/8" - 2" NPS""2"6 LF11111
1.2.3.62-1/2" - 4" NPS""2"6 LF11111
1.2.3.74-1/2" - 6" NPS""2"6 LF11111
1.2.3.86-1/2 " - 8" NPS""2"6 LF11111
2DIESEL EXHAUST INSULATION, RENEW
2.1Pre-formed Exhaust Pipe Insulation - Hard, Non-Removable
2.1.13" - 4-1/2" NPSMIL-I-2781FASTM F6834-1/2"6 LF11111
2.1.25" - 7-1/2" NPS""5-/12"6 LF11111
2.1.38" or Larger NPS""6"6 LF11111
2.2Exhaust Pipe Insulation - Removable Blankets (pads)
2.2.11-1/2" - 2" NPSMIL-I-16411, Type IINAVSEA DWG 5959212 / ASTM F6833-1/2"10 SQ-FT11111
2.2.23" NPS""4"10 SQ-FT55555
2.2.34" - 5-1/2" NPS""4-1/2"10 SQ-FT55555
2.2.46" - 8" NPS""5"10 SQ-FT55555
2.2.5Larger than 8" NPS""5"10 SQ-FT55555
3COMPARTMENT INSULATION, RENEW
3.1Air Conditioned Spaces
3.1.1Fiberous Glass Cloth-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type INAVSEA DWG 57739323/4"10 SQ-FT55555
3.1.1.1"""1"10 SQ-FT55555
3.1.1.2" - w/ lamination.""2"10 SQ-FT11111
3.1.1.3" - without lamination.""2"10 SQ-FT11111
3.1.2Fiberous Glass Un-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type IINAVSEA DWG 57739313/4"10 SQ-FT11111
3.1.2.1"""1"10 SQ-FT1010101010
3.1.2.2" - w/ lamination.""2"10 SQ-FT11111
3.1.2.3" - without lamination.""2"10 SQ-FT55555
3.1.3Fiberglass Thermal Insulation Blanket, Un-faced (Type I)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739311/210 SQ-FT55555
3.1.3.1"""1"10 SQ-FT55555
3.1.3.2"""1-1/2"10 SQ-FT55555
3.1.3.3"""2"10 SQ-FT11111
3.1.3.4"""2-1/2"10 SQ-FT11111
3.1.3.5"""3"10 SQ-FT11111
3.1.3.6"""3-1/2"10 SQ-FT11111
3.1.3.7"""4"10 SQ-FT11111
3.1.4Fiberglass Sound Absorbing Blanket, Unfaced (Type II)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739311/210 SQ-FT11111
3.1.4.1"""1"10 SQ-FT11111
3.1.4.2"""1-1/2"10 SQ-FT11111
3.1.4.3"""2"10 SQ-FT11111
3.1.4.4"""2-1/2"10 SQ-FT11111
3.1.4.5"""3"10 SQ-FT11111
3.1.4.6"""3-1/2"10 SQ-FT11111
3.1.4.7"""4"10 SQ-FT11111
3.1.5Fiberglass Thermal Insulation and Sound Absorbing Board (Type III)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739313/4"10 SQ-FT11111
3.1.5.1"""1"10 SQ-FT55555
3.1.5.2"""1-1/2"10 SQ-FT11111
3.1.5.3"""2"10 SQ-FT55555
3.1.6Fiberglass Acoustical Board, Perforated, Hard Surface (Hullboard)MIL-A-23054ANAVSEA DWG 57739311"10 SQ-FT1010101010
3.1.6.1"""2"10 SQ-FT1010101010
3.1.7Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6831/2"10 SQ-FT11111
3.1.7.1"""1"10 SQ-FT11111
3.2Non-Air Conditioned Spaces
3.2.1Fiberous Glass Cloth-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type INAVSEA DWG 57739323/4"10 SQ-FT55555
3.2.1.1"""1"10 SQ-FT55555
3.2.1.2" - w/ lamination.""2"10 SQ-FT55555
3.2.1.3" - without lamination.""2"10 SQ-FT11111
3.2.2Fiberous Glass Un-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type IINAVSEA DWG 57739313/4"10 SQ-FT11111
3.2.2.1"""1"10 SQ-FT11111
3.2.2.2" - w/ lamination.""2"10 SQ-FT11111
3.2.2.3" - without lamination.""2"10 SQ-FT11111
3.2.3Fiberglass Thermal Insulation Blanket, Unfaced (Type I)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739311/2"10 SQ-FT11111
3.2.3.1"""1"10 SQ-FT55555
3.2.3.2"""1-1/2"10 SQ-FT11111
3.2.3.3"""2"10 SQ-FT55555
3.2.3.4"""2-1/2"10 SQ-FT11111
3.2.3.5"""3"10 SQ-FT55555
3.2.3.6"""3-1/2"10 SQ-FT11111
3.2.3.7"""4"10 SQ-FT11111
3.2.4Fiberglass Sound Absorbing Blanket, Unfaced (Type II)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739311/2"10 SQ-FT11111
3.2.4.1"""1"10 SQ-FT55555
3.2.4.2"""1-1/2"10 SQ-FT11111
3.2.4.3"""2"10 SQ-FT55555
3.2.4.4"""2-1/2"10 SQ-FT11111
3.2.4.5"""3"10 SQ-FT55555
3.2.4.6"""3-1/2"10 SQ-FT11111
3.2.4.7"""4"10 SQ-FT11111
3.2.5Fiberglass Thermal Insulation and Sound Absorbing Board (Type III)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739313/4"10 SQ-FT11111
3.2.5.1"""1"10 SQ-FT11111
3.2.5.2"""1-1/2"10 SQ-FT11111
3.2.5.6"""2"10 SQ-FT11111
3.2.6Fiberglass Acoustical Board, Perforated, Hard Surface (Hullboard)MIL-A-23054ANAVSEA DWG 57739311"10 SQ-FT1010101010
3.2.6.1"""2"10 SQ-FT1010101010
3.2.7Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6833/4"10 SQ-FT11111
3.2.7.1"""2"10 SQ-FT101111
4VENTILATION DUCT INSULATION, RENEW
4.1Air Conditioned Spaces - Round or Flat Oval Ducts
4.1.1Fiberglass Thermal Insulation Blanket, Un-faced (Type I)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739321/2"10 SQ-FT11111
4.1.1.1"""1"10 SQ-FT1010101010
4.1.1.2"""1-1/2"10 SQ-FT11111
4.1.1.3"""2"10 SQ-FT1010101010
4.1.1.4"""2-1/2"10 SQ-FT11111
4.1.1.5"""3"10 SQ-FT55555
4.1.1.6"""3-1/2"10 SQ-FT11111
4.1.1.7"""4"10 SQ-FT11111
4.1.2Fiberglass Sound Absorbing Blanket, Unfaced (Type II)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 5773932-------
4.1.2.1"""1/2"10 SQ-FT11111
4.1.2.2"""1"10 SQ-FT1010101010
4.1.2.3"""1-1/2"10 SQ-FT11111
4.1.2.4"""2"10 SQ-FT1010101010
4.1.2.5"""2-1/2"10 SQ-FT11111
4.1.2.6"""3"10 SQ-FT55555
4.1.2.7"""3-1/2"10 SQ-FT11111
4.1.2.8"""4"10 SQ-FT11111
4.1.3Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6831/2"10 SQ-FT11111
4.1.3.1"""1"10 SQ-FT11111
4.2Air Conditioned Spaces - Square or Rectangular Ducts
4.2.1Fiberous Glass Cloth-Faced Board, Thermal InsulationMIL-I-742F, Type INAVSEA DWG 57739323/4"10 SQ-FT11111
4.2.1.1"""1"10 SQ-FT1010101010
4.2.1.2" - w/ lamination.""2"10 SQ-FT1010101010
4.2.1.3" - without lamination.""2"10 SQ-FT11111
4.2.2Fiberous Glass Un-Faced Board, Thermal InsulationMIL-I-742F, Type IINAVSEA DWG 57739313/4"10 SQ-FT11111
4.2.2.1"""1"10 SQ-FT11111
4.2.2.2" - w/ lamination.""2"10 SQ-FT11111
4.2.2.3" - without lamination.""2"10 SQ-FT11111
4.2.3Fiberglass Thermal Insulation and Sound Absorbing Board (Type III)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739323/4"10 SQ-FT11111
4.2.3.1"""1"10 SQ-FT55555
4.2.3.2"""1-1/2"10 SQ-FT11111
4.2.3.3"""2"10 SQ-FT55555
4.2.4Acoustic Absorptive Board, Fibrous Glass Perforated Fibrous Glass Cloth Faced (Perforated Hull Board)MIL-A-23054ANAVSEA DWG 57739321"10 SQ-FT2020202020
4.2.4.1"""2"10 SQ-FT2020202020
4.2.5Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6831/2"10 SQ-FT11111
4.2.5.1"""1"10 SQ-FT11111
4.3Non-Air Conditioned Spaces - Round or Flat Oval Ducts
4.3.1Fiberglass Thermal Insulation Blanket, Un-faced (Type I)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739321/2"10 SQ-FT11111
4.3.1.1"""1"10 SQ-FT11111
4.3.1.2"""1-1/2"10 SQ-FT2020202020
4.3.1.3"""2"10 SQ-FT3535353535
4.3.1.4"""2-1/2"10 SQ-FT2020202020
4.3.1.5"""3"10 SQ-FT2020202020
4.3.1.6"""3-1/2"10 SQ-FT11111
4.3.1.7"""4"10 SQ-FT11111
4.3.2Fiberglass Sound Absorbing Blanket, Unfaced (Type II)MIL-I-22023
tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739321/2"10 SQ-FT11111
4.3.2.1"""1"10 SQ-FT11111
4.3.2.2"""1-1/2"10 SQ-FT11111
4.3.2.3"""2"10 SQ-FT55555
4.3.2.4"""2-1/2"10 SQ-FT11111
4.3.2.5"""3"10 SQ-FT55555
4.3.2.6"""3-1/2"10 SQ-FT11111
4.3.2.7"""4"10 SQ-FT11111
4.3.3Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6833/4"10 SQ-FT11111
4.3.3.1"""2"10 SQ-FT11111
4.4Non-Air Conditioned Spaces - Square or Rectangular Ducts
4.4.1Fiberous Glass Cloth-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type INAVSEA DWG 57739323/4"10 SQ-FT11111
4.4.1.1"""1"10 SQ-FT1010101010
4.4.1.2" - w/ lamination.""2"10 SQ-FT2020202020
4.4.1.3" - without lamination.""2"10 SQ-FT55555
4.4.2Fiberous Glass Un-Faced Board, Thermal Insulation (Hullboard)MIL-I-742F, Type IINAVSEA DWG 57739313/4"10 SQ-FT11111
4.4.2.1"""1"10 SQ-FT1010101010
4.4.2.2" - w/ lamination.""2"10 SQ-FT2020202020
4.4.2.3" - without lamination.""2"10 SQ-FT11111

4.4.3 Fiberglass Thermal Insulation and Sound Absorbing Board (Type III) MIL-I-22023 tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM F683 Refs. ASTM C534 Type II only.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: 25% add-in.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.

tefrownfelter: ASTM C1139 replaces MIL-I-22023.NAVSEA DWG 57739323/4"10 SQ-FT11111
4.4.3.1"""1"10 SQ-FT55555
4.4.3.2"""1-1/2"10 SQ-FT33333
4.4.3.3"""2"10 SQ-FT55555
4.4.4Acoustic Absorptive Board, Fibrous Glass Perforated Fibrous Glass Cloth Faced (Perforated Hull Board)MIL-A-23054ANAVSEA DWG 57739321"10 SQ-FT55555
4.4.4.1"""2"10 SQ-FT55555
4.4.5Anti-Sweat Insulation, Sheet FormASTM C534 Type II GR 3ASTM F6833/4"10 SQ-FT55555
4.4.5.1"""2"10 SQ-FT1010101010
5PERFORM ULTRASONIC THICKNESS MEASUREMENTS - STEEL PLATEN/AN/AN/A50 Shots5050505050
A-OComposite Labor RateN/AN/AN/AHours-----
B-OGFP ReportN/AN/AN/AEA5454545454
C-OTravel and Per DiemN/AN/AN/AJob4627344038

Schedule B

SCHEDULE OF SUPPLIES & SERVICES (SOS&S)
US COAST GUARD WMEC 210 & 270 "A and B CLASS" MEDIUM ENDURANCE CUTTERS
IDIQ FOR INSULATION REPAIRS
ITEMDESCRIPTIONINSULATION SYSTEMINSTALLATION REF. DOC.INSULATION THICKNESS (in.)UNIT PRICEUNITEST QTYEXTENDED PRICELaborMatls.
1PIPING INSULATION, RENEW
1.1Air Conditioned Spaces
1.1.1Pre-formed Anti-Sweat Elastomeric Foam (Non-Halogen Only)6 LF / MHR$51 - $102 per 6 LFLabor Rate ($/HR)Labor + MatlsSet-Up / Misc

tefrownfelter: 25% add-in.

1.1.1.13/8" - 2" NPSEB Spec 4013ASTM F6831/2"$ 140.256 LF1$ 140.251$ 51$ 51$ 102.00$ 38.25
1.1.1.22-1/2" - 4" NPS""1/2"$ 146.256 LF1$ 146.251$ 55$ 51$ 106.00$ 40.25
1.1.1.34-1/2" - 6" NPS""1/2"$ 153.756 LF1$ 153.751$ 60$ 51$ 111.00$ 42.75
1.1.1.46-1/2 " - 8" NPS""1/2"$ 161.256 LF1$ 161.251$ 65$ 51$ 116.00$ 45.25
1.1.1.53/8" - 2" NPS""1"$ 168.756 LF1$ 168.751$ 70$ 51$ 121.00$ 47.75
1.1.1.62-1/2" - 4" NPS""1"$ 176.256 LF1$ 176.251$ 75$ 51$ 126.00$ 50.25
1.1.1.74-1/2" - 6" NPS""1"$ 186.756 LF1$ 186.751$ 82$ 51$ 133.00$ 53.75
1.1.1.86-1/2 " - 8" NPS""1"$ 216.756 LF1$ 216.751$ 102$ 51$ 153.00$ 63.75
1.1.2Pre-formed Fiberglass Pipe Insulation (1" Max. NPS applications only)$105 - $175 per 20 LF
1.1.2.13/8" NPSMIL-PRF-22344NAVSEA DWG 5959214 / ASTM F6831/2"$ 98.136 LF1$ 98.131$ 55$ 51$ 67.50$ 30.63
1.1.2.21/2" NPS""1/2"$ 98.136 LF1$ 98.131$ 55$ 51$ 67.50$ 30.63
1.1.2.33/4" NPS""1/2"$ 98.136 LF1$ 98.131$ 55$ 51$ 67.50$ 30.63
1.1.2.41" NPS""1/2"$ 98.136 LF1$ 98.131$ 55$ 51$ 67.50$ 30.63
1.1.2.51" NPS""3/4"$ 104.386 LF1$ 104.381$ 65$ 51$ 70.50$ 33.88
1.1.2.61" NPS""1"$ 104.386 LF1$ 104.381$ 65$ 51$ 70.50$ 33.88
1.1.3Sheet Form Anti-Sweat Insulation (Non-Halogen Only)Issue: 12 SQ FT

tefrownfelter: 1/2" = $25 / 1" = $42.

36" x 48" sheet.

tefrownfelter: 25% add-in.

1.1.3.13/8" - 2" NPSEB Spec 4013ASTM F6831/2"$ 75.096 LF175.091$ 4.50$ 51$ 52.3522.74
1.1.3.22-1/2" - 4" NPS""1/2"$ 78.786 LF178.781$ 9.00$ 51$ 53.7025.08
1.1.3.34-1/2" - 6" NPS""1/2"$ 81.656 LF181.651$ 12.50$ 51$ 54.7526.9
1.1.3.46-1/2 " - 8" NPS""1/2"$ 85.346 LF185.341$ 17.00$ 51$ 56.1029.24
1.1.3.53/8" - 2" NPS""1"$ 78.376 LF178.371$ 8.50$ 51$ 53.5524.82
1.1.3.62-1/2" - 4" NPS""1"$ 84.526 LF184.521$ 16.00$ 51$ 55.8028.72
1.1.3.74-1/2" - 6" NPS""1"$ 87.806 LF187.81$ 20.00$ 51$ 57.0030.80
1.1.3.86-1/2 " - 8" NPS""1"$ 91.086 LF191.081$ 24.00$ 51$ 58.2032.88
1.2Non-Air Conditioned Spaces
1.2.1Pre-formed Anti-Sweat Elastomeric Foam (Non-Halogen Only)
1.2.1.13/8" - 2" NPSEB Spec 4013ASTM F6833/4"$ 159.386 LF1$ 159.381$ 63.75$ 51$ 114.75$ 44.63

This is the start of the file's text. The full file is on GovTribe.