Telfair L_E_E_S_ Bldg Construction Drawings 1.pdf

PDF 290 KB Posted

Attached to
RFP-2025-10-01
Solicitation number
PE-77001-NONST-2026-000000015
Issued by
Union County, Georgia

About this file

This file contains construction drawings for a building addition to the Telfair County Fire Department facility in McRae-Helena, Georgia, prepared by the Telfair County Board of Commissioners. The project involves a building addition to the existing pre-engineered metal building structure, featuring the addition of multiple rooms including four bedrooms, a multi-use room, closets, storage areas, and shower facilities. The building addition measures 60 feet by 30 feet in exterior dimensions, with interior wall framing utilizing 2x4 wood studs and exterior walls constructed of 2x6 wood studs. The addition includes a gable roof with a 4:12 pitch, constructed using engineered wood trusses, OSB decking, and 26-gauge Galvalume R-panel roof sheets with an 18-inch overhang. The project is documented across four sheets including a cover sheet, floor plan, roof framing plan, and construction details. The drawings are dated October 2025 and require approval signatures from the contractor, owner, and engineering representatives.

The construction specifications include 5/8-inch sheetrock wall finishes with primer and two coats of finish paint, 2x12 floor joists with span lengths to be determined based on anticipated loads, Advantek floor decking with owner-determined flooring surface, spray foam insulation, and 8x8x16-inch CMU block foundation piers. The exterior walls are finished with 26-gauge colored R-panel metal sheets, and the project incorporates 4040 white insulated windows. The contractor is responsible for locating all underground utilities before beginning construction, with the note that utility locations shown on the drawings are approximate and certification is withheld. All contractors must call 811 or 800-282-7411 before digging and coordinate with engineering regarding any utility conflicts.

View the file

Other files

File Type Posted
RFP 2025_10_01 _ L_E_E_S_ Addition.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONSTRUCTION DRAWINGS

FOR

TELFAIR COUNTY FIRE DEPARTMENT

BY

TELFAIR COUNTY BOARD OF COMMISSIONERS

R

IT IS THE CONTRACTORS RESPONSIBILITY TO LOCATE ALL UNDERGROUND

UTILITIES BEFORE BEGINNING CONSTRUCTION AND ADVISE ENGINEERING OF

ANY CONFLICTS. ALL LOCATION OF UTILITIES SHOWN ON THESE DRAWINGS IS

APPROXIMATE AND MAY NOT BE A COMPLETE LOCATION OF ALL UTILITIES.

CERTIFICATION TO THE LOCATION OF ALL UTILITIES IS WITHHELD.

Know what's below.

Call before you dig.

Dial 811.

or call 800-282-7411

91 TELFAIR AVE, SUITE A

MCRAE-HELENA, GA 31055

OCTOBER 2025

APPROVED FOR CONSTRUCTION BY:

CONTRACTOR:______________ DATE:______

OWNER:____________________ DATE:______

BUILDING ADDITION

AutoCAD SHX Text

TELFAIR COUNTY FIRE DEPARTMENT BUILDING ADDITION

AutoCAD SHX Text

SHEET NUMBER:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BMS

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

AutoCAD SHX Text

FOR

AutoCAD SHX Text

COVER SHEET

REFRAME AND REMOVE EXISTING 12X12 ROLL UP DOOR

AutoCAD SHX Text

EXISTING PRE-ENGINEERED METAL BUILDING

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

MULTI-USE ROOM

AutoCAD SHX Text 60'-0"

AutoCAD SHX Text 30'-0"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 7'-4"

AutoCAD SHX Text 4'-4"

AutoCAD SHX Text 32'-0"

AutoCAD SHX Text 29'-8"

AutoCAD SHX Text

CLST

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 7'-4"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text

CLST

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text 4'-8"

AutoCAD SHX Text 28'-4"

AutoCAD SHX Text

48" SHOWER

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

48" SHOWER

AutoCAD SHX Text

TELFAIR COUNTY FIRE DEPARTMENT BUILDING ADDITION

AutoCAD SHX Text

SHEET NUMBER:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 10/2025

AutoCAD SHX Text

FOR

AutoCAD SHX Text FlOOR PLAN

AutoCAD SHX Text FINISHES: A. ALL WALLS TO BE 5/8" SHEETROCK WITH 1 ALL WALLS TO BE 5/8" SHEETROCK WITH 1 COAT OF PRIMER AND 2 COATS OF FINISH PAINT B. ALL INTERIOR MEASUREMENTS ARE O.C. ALL INTERIOR MEASUREMENTS ARE O.C. FROM STUD WALLS C. ALL INTERIOR WALLS ARE 2X4 WOOD STUDS ALL INTERIOR WALLS ARE 2X4 WOOD STUDS AND EXTEIOR WALLS ARE 2X6 WOOD STUDS D. ALL EXTERIOR MEASUREMENTS ARE FROM ALL EXTERIOR MEASUREMENTS ARE FROM EDGE OF BUILDING

AutoCAD SHX Text

FLOOR PLAN

SCALE: 3/8" = 1'-0"

RIDGE

AutoCAD SHX Text

TELFAIR COUNTY FIRE DEPARTMENT BUILDING ADDITION

AutoCAD SHX Text

SHEET NUMBER:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 10/2025

AutoCAD SHX Text

FOR

AutoCAD SHX Text

ROOF FRAMING PLAN

AutoCAD SHX Text NOTES: A. GABLE ROOF GABLE ROOF B. PITCHED ROOF 412 PITCHED ROOF C. 26 GAUGE GALVALUME R-PANEL ROOF SHEETS 26 GAUGE GALVALUME R-PANEL ROOF SHEETS D. 18 INCH OVERHANG18 INCH OVERHANG

AutoCAD SHX Text

ROOF FRAMING PLAN

SCALE: 3/8" = 1'-0"

10'-0" FRAMING

AutoCAD SHX Text

FINISHED FLOOR

AutoCAD SHX Text

DRYWALL CEILING AND WALLS

AutoCAD SHX Text

METAL WALL SHEET EXTERIOR

AutoCAD SHX Text

SPRAY FOAM INSULATION

AutoCAD SHX Text

WOOD STUD WALL

AutoCAD SHX Text

ADVANTEK FLOOR DECKING & FLOORING SURFACE (DETERMINED BY OWNER)

AutoCAD SHX Text 2X12 FLOOR JOISTS.FLOOR JOISTS SPAN LENGTH TO BE DETERMINED BASED OF ANTICIPATED LOADS AND SPAN CHARTS.

AutoCAD SHX Text

ENGINEERED WOOD TRUSSES (BY OTHERS)

AutoCAD SHX Text

OSB DECKING AND 26 GAUGE GALVALUME R-PANEL ROOF SHEETS

AutoCAD SHX Text 8"X8"X16" CMU BLOCK FOUNDATION PIERS. LOCATION OF PIERS TO BE DETERMINED BY LOCATION OF FLOOR JOISTS

AutoCAD SHX Text

26 GAUGE GALVALUME R PANEL METAL SHEETS

AutoCAD SHX Text

26 GAUGE COLORED WALL R PANEL METAL SHEETS

AutoCAD SHX Text

4040 WHITE INSULATED WINDOWS

AutoCAD SHX Text

TIE INTO EXISTING BUILDING

AutoCAD SHX Text

TELFAIR COUNTY FIRE DEPARTMENT BUILDING ADDITION

AutoCAD SHX Text

SHEET NUMBER:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 10/2025

AutoCAD SHX Text

FOR

AutoCAD SHX Text

CONSTRUCTION DETIALS

AutoCAD SHX Text

EXTERIOR WALL

AutoCAD SHX Text

SCALE: 1/2" = 1'-0"

AutoCAD SHX Text

FRONT ELEVATION

SCALE: NOT TO SCALE

Sheets and Views
COVER SHEET
Sheets and Views
FLOOR PLAN
Sheets and Views
ROOF FRAMING PLAN
Sheets and Views
CONSTRUCTION DETAILS

File details come from the government source that posted it. Updated .