Technical Specification for HSR 49.2 MHz RF System Circulators
This is a technical specification document for RF system circulators to be procured by Brookhaven National Laboratory (BNL), managed by Brookhaven Science Associates (BSA), for use in the Electron-Ion Collider (EIC) project. The circulators are required for the Hadron Storage Ring (HSR) 49.2 MHz RF system and will protect RF system components during normal conducting RF cavity operations by handling reflected power during bunch-splitting of hadron beams. The specification establishes technical, mechanical, environmental, and safety requirements with detailed performance parameters.
The circulators must operate at 49.2 MHz (with a range of 44.2 to 54.2 MHz) and handle steady-state forward and reverse power of 120 kW each, with insertion loss not exceeding 0.1 dB at nominal frequency and 0.2 dB at minimum and maximum frequencies. Return loss and isolation specifications require minimum 26 dB at nominal frequency and 20 dB at minimum and maximum frequencies. Interface requirements include EIA 6 1/8" coaxial connections, 1" NPT male coolant connectors, and 2x FSMA arc detector viewport connectors. Mechanical specifications mandate aluminum and/or stainless steel construction with at least three crane-lifting holes compliant with ASME BTH-1-2023, forklift-capability design, vertical mounting capability, and exclusion of Teflon-based materials. Copper or stainless steel water-cooling piping is required. Optional active compensation units must comply with 19" rack standards, operate on single-phase 120 VAC at 60 Hz with IEC 600320 C14 connectors, and provide data logging via RJ45 connectivity. Verification involves factory acceptance testing with low-power RF measurements via vector network analyzer, and site acceptance testing at BNL including high-power RF testing up to 120 kW with steady-state thermal equilibrium validation, phase specifications at discrete 45° rotations, and pulsed RF testing according to specifications (0.001 to 100 ms pulse width, 1 to 50% duty cycle).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Electron-Ion Collider, Brookhaven National Laboratory
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
Specification: Technical Specification for the HSR 49.2 MHz RF System Circulators Revision: 01
TECHNICAL SPECIFICATION
for the
HSR 49.2 MHz RF System Circulators
Quality Classification: A-3
Prepared By:
_____________________________________________ Date: __________________
Mark Hoffmann Wallner, High Power RF Engineer
Reviewed By:
Daniel Lukach, Collider HPRF Systems Manager
Alexander Zaltsman, High Power RF Technical Lead
Mike Sowinski – High Power RF Engineer
Marcel Romero – Procurement Liaison Engineer
Charles Schaefer – ES&H Manager
Christina Sullivan – Quality Assurance
Approved By:
Silvia Verdu-Andres – RF Systems Group Leader
Docusign Envelope ID: 30757783-8DAA-81B6-8331-3821860B7402
6/29/2026
6/29/2026
6/30/2026
7/8/2026
6/30/2026
6/30/2026
6/30/2026
7/8/2026
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
This page intentionally left blank, to accommodate back-to-back printing.
Docusign Envelope ID: 30757783-8DAA-81B6-8331-3821860B7402
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
REVISION HISTORY
Revision # Effective Date Summary of Change
00 3/05/2026 Initial Release
01 6/29/2026 Revisions from FDR feedback.
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
Table of Contents
LIST OF ACRONYMS
1 SCOPE
1.1 Background
2 APPLICABLE DOCUMENTS
3 SPECIFICATIONS
3.1 Technical/Performance Characteristics
3.2 Mechanical Specifications
3.3 Active Compensation Unit
3.4 Environment, Safety and Health (ESH)
4 VERIFICATION
4.1 Classification of Inspections
4.2 Factory Acceptance Testing
4.2.1 Low-power RF test
4.3 Site Acceptance Testing at BNL
4.3.1 High-power RF test
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
LIST OF ACRONYMS
AC Alternating Current
ASME American Society of Mechanical Engineers
BNL Brookhaven National Laboratory
BSA Brookhaven Science Associates
EIA American Electronic Industries Alliance
EIC Electron-Ion Collider
ESH Environment, Safety and Health
FAT Factory Acceptance Testing
FPC Fundamental power coupler
HPRF High-Power Radiofrequency
HSR Hadron Storage Ring
IEC International Electrotechnical Commission
NCRF Normal Conducting Radiofrequency
NPT National Pipe Thread
NRTL Nationally Recognized Testing Laboratory
RF Radiofrequency
SAT Site Acceptance Testing
VAC Volts Alternating Current
VNA Vector network analyzer
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
Technical Specification for the HSR 49.2 MHz RF System Circulators
1 SCOPE
This document defines the technical specifications for the Hadron Storage Ring (HSR) 49.2 MHz
Radiofrequency (RF) System Circulators to be used at the Electron-Ion Collider (EIC) at
Brookhaven National Laboratory (BNL) managed by Brookhaven Science Associates (BSA).
1.1 Background
The EIC Project will design, build, and install the accelerator hardware for a new electron storage ring, an electron injector, and modifications to the hadron ring required to produce an electron-ion collider and infrastructure. It will include one interaction region, with an allowance for a second, and one detector. The facility is designed to meet requirements to ensure high reliability and availability for the user program.
The High-Power RF (HPRF) System for the HSR 49.2 MHz RF System will be used to provide power to the 49.2 MHz Normal Conducting RF (NCRF) Cavities. These cavities will be used for the bunch splitting of hadron beams in the HSR of the EIC. During operations of the cavity, the full RF can be reflected towards the RF system requiring a circulator to protect components.
2 APPLICABLE DOCUMENTS
The following specifications, standards and drawings form a part of this specification to the extent specified herein. Unless otherwise specified, the applicable revision level of these documents shall be that in effect on the date of the solicitation or contract. Exceptions must be approved in writing by BSA.
In the event of a conflict between the applicable documents and this specification, the Contractor shall immediately notify the BSA Contractual Representative who shall in each instance determine which document takes precedence and advise the Contractor accordingly. Failure to notify BSA of a document conflict shall not relieve the Contractor’s responsibility to ensure full compliance to all requirements.
Document Number Document Title
EIC-RFS-SOW-015 Statement of Work for the HSR 49.2 MHz RF System Circulators
ASME BTH-1-2023 Design of Below-the-Hook Lifting Devices
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
3 SPECIFICATIONS
3.1 Technical/Performance Characteristics
The Circulators shall meet the interface specifications presented in Table 1. Circulator environment specifications are in Table 2, and RF performance specifications may be found in
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
Table 3.
Table 1: Circulator interface specifications.
Parameter Min. Nominal Max. Unit
Coaxial line standard EIA 6 1/8″ N/A
Coolant connectors (inlet and outlet) 1″ NPT male connector N/A
Arc detector viewport connector 2x FSMA N/A
Table 2: Circulator environment specifications.
Parameter Min. Nominal Max. Unit
Magnetic stray field1 5 Gauss
Cooling system coolant Tap or demineralized water N/A
Tolerable coolant input temperature 20 25 35 ºC
Tolerable ambient temperature 15 40 ºC
Tolerable relative air humidity 65% N/A
Tolerable coolant input pressure 10 bar
Tolerable barometric pressure 29.50 inHg
1 Measured at 1 meter distance from the device in any direction.
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
Table 3: Circulator RF specifications.
Parameter Min. Nominal Max. Unit
Operating Frequency 44.2 49.2 54.2 MHz
Reference impedance 50 ohms
Steady-state forward power2 120 kW
Steady-state reverse power at any phase2 120 kW
Insertion loss at nominal frequency3 0.1 dB
Insertion loss at min. and max.
frequency3
0.2 dB
Return loss at nominal frequency3 26 dB
Return loss at min. and max. frequency3 20 dB
Isolation at nominal frequency3 26 dB
Isolation at min. and max. frequency3 20 dB
Phase over dynamic range2 10 º
Table 4: Circulator pulsed RF specifications.
Parameter Min. Nominal Max. Unit
RF pulse width 0.001 100 ms
RF duty cycle 1 50 %
2 Refer to Section 4.3.1.1 for additional information.
3 CW & Pulsed
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
3.2 Mechanical Specifications
The Circulator must have at least 3 mounting holes prepared for crane lifting with crane eye bolts, and it must comply with ASME BTH-1-2023 standard. Also, it must be structurally designed to allow lifting with a forklift. Instructions for crane and forklifting must be provided by the
Contractor. Information about the engineering process such as, but not limited to, load stability, shear and compressive stresses, center of mass annotations, etc., must be provided. No plastic deformation of any parts shall occur during the displacement or lifting of any devices.
The body material of the Circulator must be in aluminum and/or stainless steel. Internal pipes for the water-cooling system of the Circulator must be made of either copper or stainless steel. Hoses, if used, must be made of radiation-tolerant material. Teflon-based materials must not be used anywhere in the design.
The Circulator design must allow for vertical mounting on a surface. The Circulator mounting surface may not house any one of its three main RF network connections. The Contractor must provide information regarding how much weight can be loaded and sustained by the RF connector located facing up, across the Circulator body and opposite to the mounting surface. The remaining three sides of the Circulator that are not used for mounting must each house one of the three main
RF network connections.
3.3 Active Compensation Unit
If the Contractor proposes any type of electronic mechanism to act on a parameter of the Circulator
(i.e. magnetic field) in order to comply with any specifications, this electronic mechanism must be enclosed in a 19″ rack-standard crate, and it must use a 1 Phase, 120 VAC supply with an IEC
600320 standard C14 (male) connector. It shall operate at a 60 Hz electric grid. It must also provide critical operational data via a RJ45 connector interface for data-logging purposes. A manual that describes the principles of operation and specifications of the compensation unit must be provided by the Contractor.
3.4 Environment, Safety and Health (ESH)
Identification of hazards, and their mitigation, shall occur during all stages of the life of the
Equipment including; installation, commissioning, operation, maintenance, and repair.
Identification of means to eliminate or manage each hazard shall be provided based on the following hierarchy:
• Eliminate the hazard, or manage the hazards in the following hierarchy;
• Substitute with something less hazardous, or
• Engineer – mitigate the severity of the hazard, or
• User Personal Protective Equipment (least desirable).
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
4 VERIFICATION
Appropriate inspection/tests shall be performed to ensure equipment conforms to all specifications in Section 3 of this document.
4.1 Classification of Inspections
Circulators and all accompanying equipment shall be subjected to the following inspections and testing to determine compliance with all applicable specifications:
• Factory Acceptance Testing (FAT).
• Incoming Inspection at BNL.
• Site Acceptance Testing (SAT) at BNL.
4.2 Factory Acceptance Testing
4.2.1 Low-power RF test
The Circulators shall be submitted to low-power (i.e. less than a watt entering any of its ports) RF tests. Conventional RF equipment, such as – but not limited to – a vector network analyzer (VNA), must be used. The VNA must be set up in the linear sweep frequency mode and the following setup data must be provided:
• Center frequency and frequency span;
• Output power;
• Intermediate frequency bandwidth;
• Number of data points;
• Average;
Measurements taken with the VNA in the frequency bandwidth stipulated on the requirement tables must have frequency steps not greater than 1 kHz. The calibration standard must be provided along with information about the calibration kit used. Data on the scattering parameters must be provided in the Touchstone (.sNp) file format using the magnitude [dB]/phase [º] data format.
The low-power tests must validate the following parameters of
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
Table 3:
• Insertion loss at center frequency;
• Insertion loss in bandwidth;
• Return loss at center frequency;
• Return loss in bandwidth;
• Isolation at center frequency;
• Isolation in bandwidth;
The low-power tests must be performed at the Contractor’s site, or at a Contractor’s subcontractor’s site.
4.3 Site Acceptance Testing at BNL
4.3.1 High-power RF test
The Circulator shall be submitted to high-power (i.e. up to 120 kW at the device interface ports)
RF tests. The high-power tests will be performed at BSA’s site. A test plan with the proposed setup for the high-power test will be formulated by BSA.
4.3.1.1 Phase over dynamic range
The phase over dynamic range specification defined in
Doc No. EIC-RFS-SPC-012 Author: Mark Hoffmann Wallner Effective Date: June 29, 2026 Review Frequency: N/A
Table 3 refers to how much the forward transmission phase is allowed to vary over input power.
4.3.1.2 Steady-state condition
The steady-state condition mentioned in the circulator requirement table is defined as follows: the device has been excited with a continuous-wave 120 kW RF signal and has reached thermal equilibrium. The point of thermal equilibrium will be determined by analyzing the readings from thermocouples positioned at different points of the circulator. The high-power test shall be performed in such a way as to ensure that the circulator can reliably operate in the steady-state condition.
4.3.1.3 Phase specifications of reverse power
The circulator shall be tested into an Open, Short, and Load with discrete 45◦ phase rotations at nominal frequency from 0◦ to 135◦.
4.3.1.4 Pulsed RF
The Circulator will be tested at full rated power over the pulse specifications in Table 4, verifying compliance to specifications in Table 3.