Techincal Exhibit 2 Specifications for Evaluation Submission Sheet 2.pdf

PDF 254 KB Posted

Attached to
Prefabrication Training Venues and Construction Supplies
Solicitation number
70LGLY26PREFABSUPP
Issued by

About this file

This document is a Technical Exhibit Submission Sheet for a construction materials procurement at the Federal Law Enforcement Training Centers (FLETC) Glynco Campus, detailing specific material requirements for three homes. The procurement includes 42 cubic yards of concrete, 2,040 linear feet of 5/8-inch reinforcing steel, 1,512 block units, mortar and sand, anchor bolts, and sill plate materials. Each material has precise specifications, such as concrete meeting ASTM and American Concrete Institute standards, reinforcing steel being Grade 60, and specific quantities and configurations for blocks, anchor bolts, and lumber.

The document emphasizes strict delivery and quality requirements, including that the delivery employee must be security-vetted, materials must be pre-cut and bundled by home, and the government reserves the right to reject and require redelivery of unacceptable materials at no cost. Delivery will be to Track 2 at FLETC Glynco Campus, located at 1131 Chapel Crossing Road, Glynco, GA 31524. The government will provide a 2-day notice for concrete delivery and will handle the concrete pouring, while the contractor is responsible for precise material delivery and staging.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Submission for Meet or Exceeds

(Required for Submission)

Technical Exhibit #2: Specifications for Evaluation and

Submission Sheet

Vendor must fill out Company’s name, POC, UEI, Date

Company Name:

POC:

Signature of Vendor:

Date:

UEI:

Failure to submit a complete submission sheet with vendor’s signature will be result in a not acceptable rating.

Quantity Unit of

Measure

IN EACH

Specifications salient characteristics. All specifications must be equal to the following specifications and/or salient characteristics presented

Offeror must reply to all areas in order to be evaluated by the government.

Any specification not addressed will be considered not acceptable.

Any areas deemed not acceptable will result in a overall rating of not acceptable and will not be eligible for award.

Technical Customer

Evaluation (Acceptable or Not Acceptable) na na Offeror must acknowledge all bullet points as an understanding of scope

• Furnish and deliver all listed supplies in the quantities and specifications described.

• Ensure all products meet or exceed

ASTM and

American

Concrete

Institute

(ACI)

standards for structural and finishing materials.

• Provide

Material

Safety Data

Sheets

(MSDS) for all sealants, adhesives, and other chemical products.

• Coordinate all delivery scheduling with the

FLETC

Training

Support

Division to prevent disruption to ongoing training operations.

• All materials shall be delivered and staged to Track 2, FLETC

Glynco

Campus, located at:

Chapel

Crossing

Road, Glynco, GA

31524

• Delivery employee must be able to be vetted to gain access to FLETC.

42 Cubic yards 14 cubic yards each venue. Total is 42 cubic yards for all 3. Concrete must be accepted by the government. All unacceptable concrete must be redelivered at no cost to the government. The government reserves the right to ask for rework with no extra charge to the government for concrete mix.

The government will provide a 2-day notice for the delivery of the concrete mix onsite to the build area. The government will pour the concrete.

Contractor/driver must be able to be vetted through security. Delays at the gate is at no fault of the Government.

2040 Linear feet Reinforcing Steel be 5/8-inch

(No. 5), Grade 60.

Per Home

Continuous horizontal reinforcement: approximately 680 linear feet

• Vertical dowels: 46 required per home

Total for three homes:

• Continuous rebar: 2,040 linear feet

• Vertical dowels: 138 pieces

All rebar shall be delivered pre-cut and bundled by home for ease of installation

1512 units Block Quantities

Per home:

• Standard split-face blocks (four courses): approximately 504 units

• Corner blocks: 16 units

Total for three homes:

• Standard split-face blocks: 1,512 units

• Corner blocks: 48 units

1 lot Mortar and Sand

Per home:

• Type S mortar: 1.5 cubic yards

• Masonry sand: 1.0 cubic yard

Total for three homes:

• Type S mortar: 4.5 cubic yards

• Masonry sand: 3.0 cubic yards

1 lot Anchor Bolts

Anchor bolts shall conform to manufacturer installation requirements.

Spacing requirements per home:

• Anchor bolts installed every 48 inches on center

• Anchor bolts installed 12 inches from each end of all wall runs

• Minimum number of anchor bolts per home: 46

Total anchor bolts for three homes:

• 138 anchor bolts

1 lot Sill Plate Materials Per home:

• Pressure-treated 2 x 8 x 16 lumber for 168 linear feet of sill plate

• Foam barrier for 168 linear feet Total for three homes:

• Pressure-treated lumber boards (2 x 8 x 16): 42 boards

• Foam barrier: 504 linear feet The Government will install the sill plate.

Footing Materials for all venues

File details come from the government source that posted it. Updated .