TE 3 - Inspection Form for KMC UICs.pdf
PDF 117 KB Posted
- Solicitation number
- W912CN22Q0022
About this file
This solicitation is seeking quotations for cesspool and septic tank pumping and disposal services at two Army installations on Hawaii's Big Island. The 413th Contracting Support Brigade, Regional Contracting Office Hawaii requires a contractor to provide all management, tools, transportation, supplies, equipment and labor necessary to perform waste water inspection, pumping, cleaning, treatment and disposal services for cesspools and septic tanks. Services must comply with local, state and federal laws and regulations, and meet the requirements outlined in the Performance Work Statement. Quotations are solicited on a firm-fixed price basis under solicitation number W912CN22Q0022 as a full and open competition set-aside for small businesses. The North American Industry Classification System code is 562219 with a small business size standard of $8 million. Offerors must register in the System for Award Management database and have a Commercial and Government Entity code and Data Universal Numbering System number.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TE 2A - PTA Cesspools-Septic-UIC Wells.pdf | ||
| TE 1 A - PTA Cantonment Map.pdf | ||
| TE 2B - KMC Cesspools-Septic-UIC Wells.pdf | ||
| TE 1 B - KMC Map.pdf | ||
| W912CN22Q0022 (SF-1449) Solicitation.pdf | ||
| Attachment 1 Work Experience.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TE 3
FACILITY: PAGE:_________of_________ LOCATION: *NOTE: Permit UH-2519 will expire 14-FEB-2023
Date Time Person Well No.
Thickness of Floating Material
Thickness of Sediment
Total Fluid Depth
REQUIRED INSPECTION FREQUENCY: Monthly Observations (by numbers):
1. Foul Odor 2. Sediment Build-Up 3. Losing Depth 4. Oily Sheen 5. Standing Water
6. Overflowing Well 7. Poor Drainage 8. Prohibited Discharge 9. Safety Concern 10.
Collapsed Well 11. Not Accessible 12. Satisfactory Operation 13. No Concern Seen
14. Broken/Leaky Parts 15.
KMC ID No. 8-2616.02
Wastewater Type:
Underground Injection Control (UIC) UIC (regular) Injection Well Periodic Recorded Inspection
PERMIT NO: UH-2519
Inspection Observations (use numbers) Notes on condition/level
Crater Rim Drive HVNP
Aquaculture
Sewage
Cooling
Recharge
Vehicle Wash
Industrial Runoff
Equipment Wash
A/C Condensate
Commercial Dewatering
Floor Drain
Laundry
Food Prep Seawater
Sheet1
File details come from the government source that posted it. Updated .