TE 12 - Water Storage Tank.xlsx
XLSX spreadsheet 22 KB Posted
- Solicitation number
- W5168W23R0004
- Issued by
-
Department of the Army
About this file
The document contains a technical exhibit listing water storage tanks at Yuma Proving Ground. It includes details on 52 water tanks such as tank capacity, location, year built, and area served.
The related federal contract opportunity is a solicitation from the Department of the Army seeking base operation support services at Yuma Proving Ground. Services include maintenance and operation of water and wastewater systems. The solicitation does not provide response or award dates but appears to be an ongoing requirements contract for base operation services including management of the water storage tanks listed in the technical exhibit.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| TECHNICAL EXHIBIT 12 | ||||||
| WATER TANK STORAGE | ||||||
| Tank # | Tank Capacity (x 1000) | Ground/ Elevated | Year Built | Area Served | Well # | Remarks |
| 460 | 50 | Ground | 1983 | HCA WATER PLANT | W, Z | 24’D X 16’H |
| 461 | 50 | Ground | 1986 | HCA WATER PLANT | W, Z | 24’D X 16’H |
| 463 | 5 | Ground | 1986 | HCA WATER PLANT | W, Z | HYDRO TANK |
| 1098 | 250 | Ground | 1988 | HCA | W, Z | 36’D X 34’H |
| 1099 | 250 | Ground | 1988 | HCA | W, Z | 36’D X 34’H |
| 2350 | 150 | Elevated | 1954 | WCA | T, U | |
| 2957 | 150 | Ground | 1992 | AIR CARGO | T, U | BOTH DOMESTIC AND FIRE WATER 33’D X 24’H |
| 2964 | 1 | Ground | 1992 | AIR CARGO | T, U | HYDRO TANK |
| 3006 | 100 | Elevated | 1962 | LAAF | T, U | |
| 3028 | 100 | Ground | 1970 | LAAF | DELUDGE SYSTEMS | 24’D X 32’H |
| 3126 | 5 | Ground | 1997 | WETA | S | |
| 3480 | 500 | Ground | 1973 | KFR-N | H, J | 52’D X 32’H |
| 3526 | 75 | Elevated | 1954 | KFR-S | H, J | |
| 3563 | 50 | Ground | 1960 | KFR-N | H, J | 22’D X 18’H |
| 5104 | 1 | Ground | 1971 | WETA | S | |
| 6082 | 60 | Elevated | 1960 | CDH | H, J | |
| 6086 | 125 | Ground | 1960 | CDH | DELUDGE SYSTEMS | 30’D X 24’H |
| CSFR | 1 | Ground | 1995 | CSFR | HAULED WATER | TANK IS NOT RP |
| WR369 | 100 | Ground | 2000 | KFR | 3695, "K" | POND |
| WR397 | 100 | Ground | 1973 | T-22 KFR | WW397, "R" | POND |
| WR487 | 100 | Ground | 1972 | WM ROAD | WW487 "L" | POND |
| WR730 & WR731 | 100 | Ground | 2004 | IRCC | WW730 "F" | WR731 GAME WATER & WR730 POND |
| WT310 | 15 | Ground | 1995 | DYNO | G | 12’D X 18’H |
| WT378 | 15 | Ground | 2000 | C-MINE | H, J | |
| WT398 | 1.5 | Ground | 2000 | RED BLUF | HAULED WATER | |
| WT399 | 5 | Ground | 1995 | RED BLUF | HAULED WATER | |
| WT600 | 60 | Elevated | 1993 | CDA | H, J | |
| WT741 | 5 | Ground | 2004 | SITE 8A | HAULED WATER | CIBOLA |
| WT890 | 5 | Ground | 2002 | NORTH CIBOLA | HAULED WATER | UAV COMPLEX |
| Na | 12 | TOWER TANK | 2012 | KFR | I | NON-POT CONST. WATER |
| Na | 12 | TOWER TANK | 2012 | LAAF/WCA | B | NON-POT CONST. WATER |
| Na | (2) 12 | TOWER TANK | 2013 | NORTH CIBOLA | CIBOLA WELL | NON-POT CONST. WATER |
File details come from the government source that posted it. Updated .