TDA_TBOC_Drawings_Advertise_W9127N20B0014.pdf
PDF 550 KB Posted
- Attached to
- The Dalles Thrust Bearing Oil Coolers
- Solicitation number
- W9127N20B0014
About this file
This document package includes an invitation for bid for thrust bearing oil coolers and related technical drawings. The U.S. Army Corps of Engineers Engineering District Portland seeks bids for the fabrication of nine main unit coolers and three station coolers for The Dalles Dam. Bidders must reverse engineer the coolers using an existing unit provided as a reference, and submit drawings of the fabricated coolers. The solicitation is a full and open competition under NAICS code 332410 with a 750 employee size standard. Bids are due by June 22, 2020. Offerors must register in the System for Award Management prior to bid submission to be considered for award. The acquisition is a firm-fixed-price contract resulting from an invitation for bid with definitive responsibility criteria.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A A
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N A
M E:
D R
AW
N
B Y:
C H
EC
K
ED
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
D
AT
E
S
IZ
E:
S U
BM
IT
TE
D
B Y:
PL
O
T
SC
AL
E:
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D
AT
E A
PP
R
D R
AW
IN
G N
U M
BE
R
US Army Corps of Engineers ®
PL
O
T D
AT
E:
54321
D
C
B
A
SHEET OF
BORDER VER SION UPDATE [06-2013]
DDP-9-3-7/14
1 3
TH
E
D
AL
LE
S
L O
C K
A N
D D
AM
C
O
LU
M
BI
A R
IV
ER
O R
E G
O N
-W
AS
H
IN
G
TO
N
S
TA
TI
O
N S
ER
VI
C E
T H
R U
S T
BE
AR
IN
G
O
IL
C O
O
LE
R O
VE
R
A
LL
V
IE
W
R
IC
K R
EI
N
E R
J
U
LY
R
IC
K R
EI
N
ER
M
.C O
LE
SA
R W
N
B0
M . C
O
LE
SA
R
O
N E
D D
P- 9-
3- 7/
A N
SI
D
D D
P- 9-
3- 7_
.d w g
PORTLAND DISTRICT
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S P
O R
TL
AN
D D
IS
TR
IC
T
PO
R
TL
AN
D , O
R
EG
O N
4"
CL
SECTION VIEW AA
SIDE VIEW
TOP VIEW
1" TYPICAL
STEEL BAFFLE
PLATE SHT 2
EXISTING MOUNTING PLATE
(TO BE REUSED)
STEEL ISOLATOR
BLOCK SHT 2
1/2" NOMINAL COPPER TUBING
STEEL THREAD ROD
ISOMETRIC VIEW
INNER COIL LOOP
OUTER COIL LOOP
STEEL HANGER BRACKETS
NIBCO 1 2" COPPER PIPE BULKHEAD, C x M, #750-4-1
2 TYP
SOLDER TO TUBES
32" FIBER GARLOCK GASKET
COUPLING AT SOLDER JOINT
(1 PLACE ONLY)
2''
8''1''
2''
2"-13 STEEL NUTS TYP
HANGER BRACKET BAR
2" X 2" STEEL TYP
16" BAFFLE PLATE
BETWEEN TUBE CLAMPS
SHEET 2
8" STEEL ROD
THREADED FOR LAST 2"
8"-16 NC NUTS
TYP AT 8 PLACES
1''
2'' 51
8''
16''
7 9 16"
(6 SPACES @ 11 4" +
BAFFLE PLATE @ 1 16")
8'
BEND COILS TO FIT APPLICATION
(ABOUT 13° FROM HORIZONTAL)
SYM
17''
24"
26 1 4"
NOTE: BEND INLET & OUTLET TUBES
AS NECESSARY TO ALIGN WITH
MOUNTING PLATE. NO KINKS ALLOWED.
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N A
M E:
D R
AW
N
B Y:
C H
EC
K
ED
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
D
AT
E
S
IZ
E:
S U
BM
IT
TE
D
B Y:
PL
O
T
SC
AL
E:
C O
N
TR
AC
T
N O
SHEET
IDENTIFICATION
D
AT
E A
PP
R
D R
AW
IN
G N
U M
BE
R
US Army Corps of Engineers ®
PL
O
T D
AT
E:
54321
D
C
B
A
SHEET OF
BORDER VER SION UPDATE [06-2013]
DDP-9-3-7/15
2 3
TH
E
D
AL
LE
S
L O
C K
A N
D D
AM
C
O
LU
M
BI
A R
IV
ER
O R
E G
O N
-W
AS
H
IN
G
TI
O
N S
ER
VI
C E
T H
R U
S T
BE
AR
IN
G
O
IL
C O
O
LE
R D
ET
AI
LS
R
IC
K R
EI
N
E R
J
U
LY
R
IC
K R
EI
N
ER
M
IK
E
C O
LE
SA
R W
N
B0
M . C
O
LE
SA
R
N E
D D
P- 9-
3- 7/
A N
SI
D
D D
P- 9-
3- 7_
.d w
S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S P
O R
TL
AN
D D
IS
TR
IC
T
PO
R
TL
AN
D , O
R
EG
O N
1' -1
2"
4"
8"
2" TYP
2"7 8" 65
8"
16" TYP
16" THICK STEEL PLATE
BAFFLE PLATE
2" RAD TYP
2'-11"'
EXISTING MOUNTING PLATE - SIDE VIEW
(FOR REFERENCE - TO BE REUSED)
1' -4
4"
1.32" DIA HOLE TYP
8"
8 1 2" TYP
1 1 2"
4"
ISOLATOR BLOCK
SIDE VIEW
1"'
4"
8"'
6"'
150 DEGREES
8"
8"
1 1 2"
1"
ISOLATOR BLOCK
FRONT VIEW
4"
8"
8"
64" DIA. HOLE
8"
8"
2"
1'-5"'
16"'
GROOVE IS 1 8" DEEP
AND HAS A 5 16" RADIUS
18" RADIUS
CL
SYM
2'-0"'
2" DIA STUDS TYP 4 PLACES
1" DIA TYP
32" FIBER GARLOCK GASKET
2"
4"
16"
8"
GASKET
3"
INNER LOOP SECTION A-A
NO SCALE
A A D
C
A
B
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N A
M E:
D R
A W
N B
Y:
C
H E
C
KE
D B
Y:
D E
SI
G
N E
D B
Y
D A
TE
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
P
LO
T S
C
AL
E
P
LO
T D
A
TE
C O
N
TR
A C
T N
O
SHEET
IDENTIFICATION
1 2 3 4 5 6
E
D
ES
C R
IP
TI
O N
M
AR
K D
A
TE
A
PP
R
US Army Corps of Engineers ®
SHEET OF
BORDER VERSION UPDAT E [06 -2013]
DDP-9-3-7/16
3 3
TH
E
D
AL
LE
S
LO
C
K
AN
D D
AM
C
O
LU
M
BI
A R
IV
ER
O R
EG
O
N -W
AS
H
IN
G
TI
O N
S
ER
V
IC
E T
H R
U S
T B
E
AR
IN
G
O
IL
C O
O
LE
R D
ET
A
IL
S
R
IC
K R
E
IN
ER
J U
LY
R
IC
K R
EI
N
ER
M
IK
E
C O
LE
SA
R W
N
B0
M . C
O
LE
AR
N E
D D
P- 9-
3- 7/
A N
S I
E D
D P
-9 -3
-7 _1
6.
dw
S
A R
M Y
C O
R P
S O
F
EN
G
IN
EE
R
S
PO
R
TL
A N
D D
IS
TR
IC
T
P O
R
TL
AN
D
, O R
2"
12" 12"
8" 8" 8"
6 SPACES @ 11
4" = 71
2"
DOESN'T INCLUDE
BAFFLE PLATE THICKNESS
INNER LOOP TOP VIEW
NO SCALE
8°
R23
8"
2"315
16"81 16"
13° 7 8"
R25
16" TYP
GASKET
NO SCALE
8"
4"
2"
16"
32" FIBER GARLOCK GASKET
1 5 16" DIA
3"
Main Unit Thrust Bearing Oil Cooler Half
FIO-001
For Reference Only 1 Cooler Requires 2 Halves per Unit Solicitation #W9127N20B0014
File details come from the government source that posted it. Updated .