This Statement of Work (SOW) details a security enhancement project for DLA Distribution in Corpus Christi, TX, focusing on Building 15. The project involves installing three interior fence lengths from floor to ceiling, with specifications including a 6-foot tall fence, 2-foot top guard, and triple strand facing away, ultimately creating an 8-foot tall secured area. Additional requirements include installing an Emergency Exit Panic Gate that meets UFC standards and a speed door on the existing roll-up door.
Specific technical requirements mandate that chain link fences and gates comply with UFGS 32 31 13 and UFGS 32 31 13.53 standards, referencing ASTM F2611 and ASTM F1712 for material specifications. The fencing is intended to provide physical security functions such as defining legal boundaries, controlling access points, supporting surveillance, deterring intruders, and delaying unauthorized entry. The project's end goal is to upgrade existing fencing and create a new storage lot adjacent to Building 1846 for equipment and materials relocation in preparation for a future Disposition Warehouse.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Tab 4-DDCT_Bldg15_Upgrade.pptx | PPTX presentation | |
| Tab 11 - CSS SP330025Q0110.pdf | ||
| Tab 9-Wage Determination.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement-of-Work (SOW) for AT/FP/Industrial Security: FENCE(s) BLDG 15
• Name of site where work is to be performed;
DLA Distribution Corpus Christi, TX
• Scope of work to be accomplished/Justification/End result to be achieved
Requesting the addition of fencing of current storage Bldg. 15. The physical security barrier provided by a security fence provides one or more of the following functions:
• Gives notice of legal boundary of the outermost limits of the protected area.
• Assists in controlling and screening authorized entries into secured/protected areas by channeling vehicles and personnel to access control points.
• Supports surveillance, detection, assessment, and other security functions by providing a platform for installing intrusion detection equipment.
• Deters casual intruders from penetrating a secured/protected area by presenting a barrier that requires an overt action to enter.
• Causes a delay to obtain access to a installation/facility, thereby increasing the probability of detection. The end result is to give an upgrade to the existing fencing and create a new storage lot adjacent to Bldg. 1846 for the placement of the Lot K equipment/materials, which is going away to build a Disposition Warehouse for
DLA.
• A requested speed door on the interior of the only electrical roll up door to meet AIE standards in UFC 4-022- 01 Entry Control Facilities. Speed door has no specific standards except for AIE criteria.
• A Emergency Exit Panic Gate that meets UFC guidance and has a way to lock from outside and still have egress from inside. (See designs)
• IT Requirements
N/A
• Total number of buildings to have work performed, to include building numbers/bays
Total Number of Buildings = Bldg. 15 x 3 Interior Fence Section w/topguard, One Emergency Exit Panic Gate, One Speed Door to meet AIE standards
• Location of work in the buildings (office, warehouse, restrooms, roof, interior, exterior, street lights, etc.)
Interior of Warehouse where no walls exist have 3 fences installed, have one speed door installed on only roll up door, One Emergency Exit Panic Gate that meets the UFC standards with egress and outside locking capability
• Quantity/Size of items required This information can be found in the pdf.
• Recommended sources for unusual or specialty item building materials
N/A
• Special requirements for project work (codes, regulations, etc.)
Requirements for all Fences are to meet UFC 4-022-03, Speed Door and emergency Exit Panic Gate need to meet all UFC Fire Regulations and OSHA standards.
• Specific makes, models, colors, etc., if applicable Shall be:
Chain link fences and gates must comply with specification requirements in UFGS 32 31 13, Chain Link Fences and Gates and UFGS 32 31 13.53, High-Security Chain Link Fences and Gates. Consult with ASTM F2611 and ASTM F1712 for additional guidance (fabric, post, framework, fittings, and other accessories) regarding chain link fencing. Refer also to the Chain Link Manufacturers Institute’s Security Fencing Recommendations (CLF-SFR0111) and Product Manual (CLF0PM0610) for additional information.
• Indicate whether to Remove/Replace/Repair/Install/Construct/Provide
Project will consist of installing 3 fence lengths from floor to ceiling with topguard as ceiling cannot be reached due to pipes, electric, etc., the fence will have, top guard, and triple strand installed. Bldg. 15 will be from 3ft to 12ft in height to include the topguard. The fence is to be 6ft tall with a top guard to be 2ft tall with triple strand facing away, which will make the fence 8ft. tall per. UFC regulatory guidance for a Controlled area. As this is inside it can reach a height of 12 feet and no greater to meet UFC criteria. All materials left over from the build need to be removed by the Contractor. You will be installing an Emergency Exit Panic Gate, 3 fenced in areas, and installing a Speed Door on the Roll Up Door.