T14000_Spec_080720.pdf
PDF 3 MB Posted
- Solicitation number
- 300000295769557
- Issued by
- Missouri
About this file
This document is a technical specification sheet for Tubelite Inc.'s T14000 Series Storefront Framing system, provided in relation to the Missouri Department of Transportation's (MoDOT) FY27 Southeast Sikeston Office Window Replacement Project. The solicitation seeks qualified offerors to remove and replace all exterior storefront window frames and glass at MoDOT's Southeast District Office in Sikeston, Missouri. The contract period extends from the date of full execution through June 14, 2027. Pre-proposal attendance is mandatory for proposal acceptance. Proposals must be submitted electronically through MissouriBUYS, by mail via USPS, UPS, or FedEx, or in hard copy with five business days' advance notice to the buyer of record, Logan Wilbers. A proposal bond is required and must be submitted to the buyer at 830 MoDOT Drive, Jefferson City, Missouri 65109.
The T14000 Series specification details a 2" x 4-1/2" center set, flush-glazed storefront framing system designed for low-rise commercial applications including retail, office, healthcare, and schools. The system features a single cavity pour and debridge thermal barrier with standard features including a 2" sight-line on verticals and horizontals, EPDM wedge-type gaskets for 1" glass or panel thickness, and a U-Factor of 0.38 for thermally insulated frames or 0.33 for thermally broken frames. Optional features include screw-spline or shear block connections, steel reinforcing, and integration with standard or thermal doors and operable vent windows. The specification includes performance ratings: air infiltration of 0.06 CFM/Ft² at 6.24 PSF, water infiltration of 10 PSF static and dynamic with 30 PSF design and 45 PSF overload structural ratings, acoustic performance with STC 32 and OITC 26, and compatibility with glass up to 1-1/8" thick. Standard anodized and painted colors are available with warranted protection.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MODOT 0000000412SL_1_SUPPLIER.pdf | ||
| Amendment 01 - Sikeston Drawings.pdf | ||
| section 01300 and 01700.pdf | ||
| AWO 33.pdf | ||
| Sikeston Office Window Pictures.docx | DOCX document | |
| Tubelite_E-T-TU14000-Storefront_Guide-Spec.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
800-866-2227 / www.tubeliteinc.com
T14000 Series Storefront Single cavity pour and debridge thermal barrier
For optimal strength and thermal performance, use Tubelite’s 14000 Series Storefront Framing, a flush-glazed system for use on storefront and low-rise applications.
Framing is available in standard single cavity pour and debridge thermal barrier members with 2" x 4-1/2" profiles and a 1/2" bite for use with glass or panels up to 1-1/8" thick. Extra-heavy intermediate verticals are available for high performance against strong windloads.
Reduce project labor costs with the flexibility of inside or outside glazing. Members can be assembled using screw spline or clip joinery, and framing is compatible with Tubelite Narrow, Medium and Wide Stile Doors.
Our 14000 Series Storefront products are subjected to thorough testing by an independent laboratory, ensuring that you get the highest quality storefront framing products that the industry has to offer.
Standard Medium Stile Entrances
200 Series Curtainwall
ALSO
USED
WITH
Wendy’s, Cemetery Road, Hilliard, OH
3056 Walker Ridge Drive NW, Suite G, Walker, MI 49544
DISCLAIMER: Tubelite takes no responsibility for product selection or application, including, but not limited to, compliance with building codes, safety codes, laws, merchantability or fitness for a particular purpose; and further disclaims all liability for the use, in whole or in part, of this Technical Guide in preparation of project specifications and/or other documents.
Technical Guides are subject to change at any time, without notice, and at Tubelite’s sole discretion. ©2017 Tubelite Inc.
System Features:
• � Standard 2" (50.8mm) sight-line on verticals and horizontals
• � 4-1/2" (114.3mm) system depth
• �Single cavity pour and debridge thermal barrier with
Azon’s Lancer® mechanical lock
• � EPDM wedge type gaskets for 1" glass or panel thickness
• � Glass centered in the system depth
Optional Features:
• � Screw-spline or shear block connections
• � Steel reinforcing if required
• � Easily integrates with standard or thermal doors , operable vent windows & sun shades
• � A wide variety of standard anodized and painted colors are available to complement any project with warrantied protection, as well as street appeal.
• � Curved Headers
• � Non-thermal Framing
800-866-2227 / www.tubeliteinc.com
080720
T14000 Series Product Specifications
Application: Low-rise commercial buildings: retail, office, healthcare, schools, etc.
Description: 2" x 4-1/2" center set, outside or inside flush glazed storefront
Face Width:
System Depth: Glass: Air Infiltration: Water
Infiltration: Structural: CRF: U-Factor**: Acoustic:
2" 4-1/2" 1" std
(1/8" – 1-1/8")
0.06 CFM/Ft.2
@ 6.24 PSF
10 PSF – Static
10 PSF – Dynamic 30 PSF – Design
45 PSF – Overload T (Thermal) 62F
68G
0.38 - Thermally Insulated
0.33 - Thermally Broken
STC 32
OITC 26
4- 1/ 2"
2"
4- 1/ 2"
2"
2"
4- 1/
2"
** U-Factor per NFRC 100: COG = 0.24 with warm edge spacer, 1-3/4” x 4-1/2” non-thermal frame.
Refer to the U-Value table at: www.tubeliteinc.com/products/storefront/14000-series-storefront-framing/ for other glass makeups and configurations.
T14000 Series Storefront Single cavity pour and debridge thermal barrier
File details come from the government source that posted it. Updated .