T02 47PE0721R0028 Description Sheets Combined.pdf

PDF 3 MB Posted

Attached to
OPM Office Renovation Design-Build - Fort Lauderdale Courthouse
Solicitation number
47PE0721R0028
Issued by

About this file

This federal contract opportunity notice seeks proposals for an OPM Office Renovation design-build project located at the Fort Lauderdale Federal Building & Courthouse. The General Services Administration Public Buildings Service Region 4 is soliciting proposals for approximately 1646 square feet of office space renovation including architectural, access controls, intrusion detection system, intercom, door, electrical, and communications requirements. Interested vendors must pre-register by 15 April 2021 to attend the site visit on 21 April 2021 and submit questions by 26 April 2021. Proposals are due by 14 May 2021. This 100% set-aside acquisition for Service Disabled Veteran Owned Small Business concerns is estimated between $250,000 to $500,000. The total design and construction period of performance is 210 days from notice to proceed.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JO Series Video IntercomVVVVViiiiidddddeeeeeooooo IIIIInnnnndeodeo ttttteeeeerrrrrcccccooooorrrrrrr mmmmm

Slim Design ▪ 7" Screen

Door Entry Security

JO Series 7" Video Intercom

7" Screen Actual Size

• Touch Buttons A light touch is all that is required to control the system

• Improved Picture Quality New door station camera provides clear visitor images for reliable identifi cation

• Elegant Styling Sleek design matches home or business decors

• Cost Eff ective A quality solution at a reasonable price

• 2-Conductor Wiring Can be installed using existing doorbell wire

Screen images simulated

2 | JO Series

Control with Touch Buttons

3-Way Communication All stations can communicate simultaneously to assist visitors*

* The JO Series does not support internal communication. The JO-1MD and the JO-1FD can only converse together when they are both in active communication with the door station.

JO-1MD

JO-1FD

Perfect for

Offi ces

Stylish for

Homes

JOS-1V Box Set

Security, convenience, and style all rolled into one! The contemporary design complements today’s homes.

The JO Series helps to identify visitors, colleagues, appointments, or potential threats at an entrance.

| 3

Monitor Discreetly view entrances to view possible disturbances

Volume Select communication and door call-in volume

LCD Adjustment Select screen brightness

Secondary Device Control optional devices, such as exterior lights, gates, etc.

Door Release Easily unlock a door or an entrance

Hands-Free Communication Touch to activate hands-free

VOX communication or press and hold to switch to PTT mode

#91271 JO Series Brochure

03 / 2016

Printed in USA

Aiphone Co. Ltd.

Deming Prize

Aiphone Corp.

ISO 9001:2008

Certified

The information in this brochure is subject to change without notice. Aiphone Co. Ltd.

ISO-14001

Certified

Copyright © 2016. All Rights Reserved • T: (800) 692-0200 • F: (800) 525-3372 • www.aiphone.com |

Door Station* | JO-DVF: Video door station, stainless steel, flush mount

H: 8-1/4" W: 5-5/16" D: 1-7/8"

Master Station* | JO-1MD: Video intercom master station with touch buttons

H: 5-1/8" W: 9-1/16" D: 13/16"

Power Supply | PS-1820UL: Power supply

JOS-1F Box Set

AC-10S

Access control keypad, zinc die cast to match

JO-DV, surface mount

Master StationAdd-on Station

JO-DV

2 2

6 2

330’ 330’ Door Station

Secondary Output Control

JO DV

IER-2

2 2 2

Secondary Output Control

IER-2IER 2

JO-1MD

PS-1820UL

JO-1FD

PT

: PT-1210N TransformerPT

Door Station Master Station

JO-DV

330’ 2 2

JO DV

IER-2

PT

Start with a box set

WiringWiring

Begin by selecting a JO Series Box Set. To have a secondary station communicate and control the door station, install a JO-1FD.

Each set contains a JO-1MD master station, door station, and PS-1820UL power supply. Just add wire!

* Door stations and JO-1MD are not sold separately

Includes:

Door Station* | JO-DV: Video door station, zinc die cast, surface mount

H: 6-13/16"W: 3-7/8" D: 1-1/16"

Master Station* | JO-1MD: Video intercom master station with touch buttons

H: 5-1/8" W: 9-1/16" D: 13/16"

Power Supply | PS-1820UL: Power supply

JOS-1V Box Set

Door Station* | JO-DA: Video door station, plastic, surface mount

H: 5-1/16" W: 3-13/16" D: 1-3/8"

Master Station* | JO-1MD: Video intercom master station with touch buttons

H: 5-1/8" W: 9-1/16" D: 13/16"

Power Supply | PS-1820UL: Power supply

JOS-1A Box Set

Includes: Includes:

RY-ES

External signaling relay

Add-on Station 1 per system

Accessories

JO-1MD only

JO-1MD and JO-1FD

JO-1FD

Video intercom expansion station with touch buttons

H: 5-1/8" W: 9-1/16" D: 13/16"

IER-2

Call extension speaker

MCW-S/A

Inside station desk stand

Additional ComponentsWiring

JO Series Components

2 2

Secondary Output ControlPS-1820UL

JO-1MDJO 1MD

interlogix.com

High Security Surface Mount Magnetic Contacts 2700 Series

The 2700 Series High Security magnetic contacts with triple-biased reeds are highly resistant to defeat by external magnets. For added security, magnetic field tamper and pry tamper are standard features. Each 2700 contact and actuation magnet set is factory compensated for the effects of steel. All 2700 Series contacts are accepted by the Defense Intelligence Agency. They are listed in DIAM 50-3 for use in secure compartmented information facilities (SCIFs). 2700 Series High Security magnetic contacts are UL listed. Two models are listed for use on safes and vaults.

The 2700 Series can be used to protect doors in high security locations or where high value materials are stored. They have effectly been used at airports, biotechnology labs and other medical research settings, warehouses, manufacturing plants, jewelry stores, banks, data processing centers, military bases, ammunition depots and energy-generation facilities.

2707A/2707AD

The switches contains three independent Form C biased reed contacts, wired in SPDT configuration (model 2707A);

or six independent Form C biased reed contacts, wired in DPDT configuration (model 2707AD). A supervised loop with a magnetic tamper feature is included on both models. A pry tamper connection is also available for the 24-hour loop.

2706AP/2706AS

The switches contain three independent Form C biased reed contacts, wired in SPDT configuration. A supervised loop with a series magnetic tamper and pry tamper are also included. Both models conform to Class IV Preadjusted Balanced Magnetic Contacts specifications. A remote test feature is provided in the protective loop (AP models) or in the supervised loop (AS models).

Overview

• Triple biased for increased security

• No field adjustment

• Pry tamper included

• Supervision and remote test options available

• UL listed for safes and vaults – 2707A, 2707AD

Standard FeatureS

Intrusion

High Security Surface Mount Magnetic Contacts 2700 Series

North America T 855-286-8889

Asia T 852-2907-8108

Australia T 61-3-9239-1200

Europe T 32-2-725-11-20

Latin America T 561-998-6114 interlogix.com

Specifications subject to change without notice.

© 2013 Interlogix.

All rights reserved.

Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.

306-3687 2013/07 (75105)

Dimensional Diagram

Magnet

1.50 in.

38.1mm

.75 in.

19.1mm

4.25 in.

108mm

3.50 in.

88.9mm

1.50 in.

38.1mm

.75 in.

19.1mm

.16 in.

4.1mm dia.

.38 in.

9.7mm

.38 in.

9.7mm

UL®

LISTED

Specifications Voltage 30V AC/DC maximum Current 0.25A maximum Power 3.0W maximum Dimensions (LxWxH) 4.25 x 1.50 x .75 in. (10.80 x 3.81 x 1.91 cm) Material Brushed anodized aluminum Listing UL-634

Ordering Information

2706AP-L

High Security Contacts w/Armored Cable, Triple Biased, SPDT, Remote Test- Protective Loop, 3/16” to 5/8” Gap Size, Single Pole-Double Throw, 3’ Stainless Steel Armored Cable

2706AS-L

High Security Contacts w/Armored Cable, Triple Biased, SPDT, Remote Test- Supervised Loop, 3/16” to 5/8” Gap Size, Single Pole-Double Throw, 3’ Stainless Steel Armored Cable

2707AD-L High Security Contacts w/Armored Cable, Triple Biased, DPDT, 3/16” to 5/8” Gap Size, Double Pole-Double Throw, 3’ Stainless Steel Armored Cable

2707AD-L5 High Security Contacts w/Armored Cable, Triple Biased, DPDT, 3/16” to 5/8” Gap Size, Double Pole-Double Throw, 5’ Stainless Steel Armored Cable

2707A-L High Security Contacts w/Armored Cable, Triple Biased, SPDT, 3/16” to 5/8” Gap Size, Single Pole-Double Throw, 3’ Stainless Steel Armored Cable

Intrusion Alarm Systems | D1255 Series VFD Keypads

D1255 Series VFD Keypads www.boschsecurity.com u Easy to read vacuum fluorescent display (VFD) u Easy system control with menu keys u User controlled brightness and volume u Installer configured menus, text, and custom functions u Multiple or single area configurations

Each D1255 Series VFD Keypad model is an SDI bus compatible device that works with the G Series Control Panels and the D9124 Addressable Fire Alarm Panel. Each keypad model has an illuminated keypad, 16-character English language vacuum fluorescent display (VFD), and a sounder that emits eight tones.

System overview

Use D1255 Series Keypad models in applications for system controllers and annunciators:

• For commercial use, install the keypad in building entrances and areas with unrestricted access.

Mounting a keypad near exterior doors in hotel or business lobbies allows people to identify the type and location of the emergency.

• For residential use, install the keypad near the front and rear entrances to the home. Install additional keypads in a kitchen or in a bedroom.

• Use multiple keypads in a large building with many separate areas of security. Program multiple keypads to control multiple areas.

• Install the keypad in locations that are hidden from view. Audible tones from the keypad sounder alert personnel to fire events and assist fire fighters in locating the keypad.

Functions

Display Every D1255 Series Keypad model uses words, numbers, and symbols to show the status of the security system. When several events occur, each model shows each event in order of priority.

Keys Each D1255 Series Keypad model has 10 numeric keys and five function keys. Use the [COMMAND] key with the numeric keys to perform a function. Use the [ENT] key or [YES] key to enter your passcode. When pressed, each key emits light and a muted beep.

Audible Tones The sounder emits eight distinct warning tones. You can adjust the volume or use a passcode to silence the tone. The tones include:

• Burglary Signal: Steady high-pitched bell tone during alarm.

• Fire Signal: Pulsed high-pitched bell tone during fire alarm.

• Entrance Warning: Intermittent beep tones during entry delay periods.

• Exit Warning: Intermittent beep tones during exit delay periods.

• Invalid Key Buzz: Buzz tone when an invalid key is pressed.

• Keypad Encoding Tone: Muted beep tone as each key is pressed.

• Trouble Buzzer: Two-tone warble during a trouble event.

• Watch Tone: Intermittent beep tone when a watch point is faulted.

Certifications and approvals

Region Certification

USA UL D1255: AMCX: Central Station Alarm Units (UL1610, UL1635), AMCX7: Cen-tral Station Alarm Units Certified for Can-ada (cULus), AMTB: Control Panels, SIA False Alarm Reduction, AOTX: Local Alarm Units (UL464, UL609), AOTX7:

Local Alarm Units Certified for Canada (cULus), APAW: Police Station Alarm Units (UL365, UL464), APAW7: Police Station Alarm Units Certified for Canada (cULus), APOU: Proprietary Alarm Units (UL1076), APOU7: Proprietary Alarm Units Certified for Canada (cULus), NBSX: Household Burglar Alarm System Units (UL1023), NBSX7: Household Burglar Alarm System Units Certified for Canada (cULus), UTOU: Control Units and Accessories - Household System Type (UL985), UTOU7: Control Units and Accessories - Household System Type Certified for Canada (cULus)

UL D1255W: AMCX: Central Station Alarm Units (UL1610, UL1635), AMTB: Con-trol Panels, SIA False Alarm Reduction, AOTX: Local Alarm Units (UL464, UL609), APAW: Police Station Alarm Units (UL365, UL464), APOU: Propriet-ary Alarm Units (UL1076), NBSX:

Household Burglar Alarm System Units (UL1023), UTOU: Control Units and Ac-cessories - Household System Type

(UL985)

FM D1255

CSFM see our website

NYC-

MEA

D1255: 12-92-E, Vol. IV 12-92-E, Vol.

IV

NYC-

MEA

D1255: 12-92-E, Vol. 12 12-92-E, Vol.

NYC-

MEA

D1255: 12-92-E, Vol. 15 12-92-E, Vol.

Canada ULC D1255B: AMCX7: Central Station Alarm Units Certified for Canada (cUL), AOTX7: Local Alarm Units Certified for Canada (cUL), APAW7: Police Station Alarm Units Certified for Canada (cUL), APOU7: Proprietary Alarm Units Certi-fied for Canada (cUL), NBSX7: House-hold Burglar Alarm System Units Certi-fied for Canada (cUL), UTOU7: Control Units and Accessories - Household Sys-tem Type Certified for Canada (cUL)

ULC AMCX7.S1871 - Central Station Alarm Units Certified for Canada

Region Certification

ULC APOU7.S1871 Proprietary Alarm Units Certified for Canada

ULC AOTX7.S1871 Local Alarm Units Certi-fied for Canada

ULC APAW7.S1871 Police-station-connec-ted Alarm Units Certified for Canada

ULC NBSX7.S1871 Household Burglar Alarm System Units Certified for Canada

ULC AMCX.S1871, AMCX7.S1871,

AMTB.S1871, AOTX.S1871,

AOTX7.S1871, APAW.S1871,

APAW7.S1871, APOU.S1871,

APOU7.S1871, NBSX.S1871,

NBSX7.S1871, UTOU.S1871, [D1255

VFD]

Installation/configuration notes

Compatible Control Panels

• B9512G/B9512G-E

• B8512G/B8512G-E

• D9412GV4/D7412GV4/D7212GV41

• D9412GV3/D7412GV3/D7212GV31

• D9412GV2/D7412GV2/D7212GV21

• D9412G/D7412G/D7212G

• D9412, D7412, D7212, and D9112 with firmware versions 6.40 or higher

• D9124

1The D7212GV4, D7212GV3, D7212GV2, D7212G are not listed for commercial fire applications.

Mounting Considerations

• Do not mount any of the D1255 Series Keypad models in a location exposed to direct sunlight.

Direct sunlight can interfere with screen visibility and damage internal components.

• Do not mount any of the D1255 Series Keypad models in damp locations.

Power Supplies A compatible control panel supplies the power and data requirements to a D1255 Series Keypad model through a four-wire connection.

Wiring Considerations Use 0.8 mm (22 AWG) or 1.2 mm (18 AWG) wire.

Resistance cannot exceed 25 Ω. Each D1255 Series Keypad model includes a wiring assembly of four color-coded flying leads and one female four-pin connector.

Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.

Parts included

Quant. Component

1 Keypad

2 | D1255 Series VFD Keypads

1 Hardware pack (3 screws and 3 anchors)

1 Literature pack

• Pull-up Reference Card

• Users Guide

• Installation Guide

Technical specifications

Connections

Connections: 4-wire flying lead for data and power

Resistance: 25 Ω maximum

Environmental Considerations

Temperature (Operating): 0°C to +50°C (+32°F to +122°F)

Relative Humidity: 5% to 85% at +30°C (+86°F)

Keypad

Dimensions for D1255, D1255W, and D1255R:

11.7 cm x 21 cm x 2 cm (4.6 in. x 8.2 in. x 0.8 in.)

Dimensions for D1255B: 12.6 cm x 20 cm x 3.2 cm (5 in. x 7.9 in. x 1.3 in.)

Weight for All Models: 439 g (15.5 oz)

Material for All Models: CHI MEI POLYLAC PA757 ABS with UV Stabilizer. UL94-HB Fire Rated

Display Window: 16-character vacuum fluorescent display Each character is a 14-segment unit

Indicators: Illuminated keys Warning and indicating tones

Number of…

D1255 Series Keypad Models per Control Panel:

Eight supervised 32 unsupervised

Power Requirements

Voltage: Nominal 12 VDC

Current: Idle 104 mA, armed or disarmed;

Maximum 206 mA, with keypad lit and warning tone on

Ordering information

D1255 VFD Keypad Off-white classic case.

Order number D1255

D1255W VFD Keypad White classic case.

Order number D1255W

D1255B VFD Keypad White and gray modern case.

Order number D1255B

Accessories

D54B Brass Flush‑mount Kit Back box and polished brass faceplate.

Order number D54B

D54C Stainless Steel Flush‑mount Kit Back box and stainless steel faceplate.

Order number D54C

D55 Keypad Desk Stand Portable desk stand in smoke colored Plexiglas.

Order number D55

D56 Surface Mount Conduit Box White surface mount box.

Order number D56

D56R Red Surface Mount Conduit Box Red surface mount box.

Order number D56R

3 | D1255 Series VFD Keypads

4 | D1255 Series VFD Keypads

Represented by:

North America: Europe, Middle East, Africa: Asia-Pacific: China: Latin America and Caribbean:

Bosch Security Systems, Inc.

130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us

Bosch Security Systems B.V.

P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com

Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia

Bosch (Shanghai) Security Systems Ltd.

203 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn

Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98

CEP 13065-900

Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com

© Bosch Security Systems 2016 | Data subject to change without notice 2528705803 | en, V9, 18. Mar 2016

Intrusion Alarm Systems | D9412GV4 Control Panel

D9412GV4 Control Panel www.boschsecurity.com u Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three u Conettix IP‑based communication options provide high‑speed, secure alarm transport and control through connection of wired and/or cellular network interfaces u Up to 32 programmable areas, each supporting perimeter and interior points with your choice of touch screen, ATM style, or LED keypads u 246 hardwired, addressable or wireless points with flexible configuration options to meet multiple installation requirements u OPTIONAL GV4 version 2.xx firmware upgrade available

GV4 panels are the premier commercial control panel line from Bosch. GV4 panels integrate intrusion, fire and access control providing one simple user interface for all systems. With the ability to adapt to large and small applications, the D9412GV4 provides up to 246 individually identified points that can be split into 32 areas. The control panel includes a communicator that sends events to selected public switched telephone network (PSTN), IP network, or cellular network destinations through four programmable route groups.

With the D9412GV4 you can:

• Monitor alarm points for intruder or fire alarms while operating keypads and other outputs

• Program all system functions local or remote using Remote Programming Software (RPS) or by using basic programming through the keypad.

• Add up to eight doors of access control using the optional D9210C Access Control Interface Module.

Functions

Programmable outputs

• 2 A alarm power at 12 VDC

• 1.4 A auxiliary power at 12 VDC

• Four alarm‑output patterns

• Programmable bell test

System response

• High-performance micro‑controller provides industry‑leading system response

• High-speed device bus

• 31 custom point indexes, including fire supervisory

• Selectable point response time

• Cross point capability

• Fire alarm verification

• Fire inspector’s local test

• Watch mode

• Scheduled events (SKEDS) arm, disarm, bypass and unbypass points, control relays, control authority levels, and control door access

User interface

• Supervision of up to 16 keypads (up to 32 unsupervised keypads can be used)

• Remote Programming Software (RPS) allows end users to perform control panel management tasks – Add/Delete/Change user passcodes and authorities, view and print the panel history event log

• Custom keypad text is fully programmable, including remote programming

• Full function command menu including Custom Functions

• Authority by area and 16‑character name for each user

• 14 custom authority levels control user’s authority to change, add, or delete passcodes or access control credentials; to disarm or bypass points; and to start system tests

Area configurations Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master or associate). Any area can be configured for perimeter and interior arming, not requiring a separate area for this function.

Custom functions For added convenience, Custom Functions can be programmed to eliminate keystrokes for users allowing the installer to program an easy command for a complicate function. For example, a custom function can be written to bypass a group of points and arm the system, allowing the user to perform this function with one easy command. This can be used to control a particular room, or even a single door allowing customized access. In additions, Custom Functions can be activated with a token or card, or automatically as a scheduled event (SKED) providing further flexibility and ease of use.

Door-activated custom function A custom function activates when user credentials are presented to a B901 or D9210C access control module’s door controller's reader. The custom function behaves as though the user performed a function at the keypad associated with the door controller.

Passcode security For high security applications, GV4 can be configured for several different passcode options.

• Dual Authentication – requires a user to enter their passcode and also use a token or card.

• Two-Man Rule - Requires two people with two unique passcodes to be present at the time of opening.

• Early Ambush - Allows users to verify that the facility is safe by requiring two passcode entries at different keypads within the same area, sending a duress event if the user does not enter the passcode a second time after inspecting the premises.

Easy Exit control The control panel changes from one armed state to another armed state without disarming. For example, if you change the state from Perimeter Arm to Master Arm, the control panel complies and reports the change. Easy Exit Control reduces the number of keystrokes, simplifying system operation.

Programmable passcode-controlled Menu List The system prompts users to enter a passcode prior to viewing the keypad menu. The keypad display shows the user the menu options allowed according to the user’s authority level. Passcode-controlled menus provide users only with the options and information pertinent to them, simplifying system operation.

Flexible control The system provides the flexibility to select added convenience or high security. For example, you can restrict passcode arming and disarming to a keypad's immediate local area, even if the user has access to other areas. This is particularly useful for high security areas, where a user may have access to the area, but would prefer to only disarm the area individually rather than with the rest of the system. Another option is to program the system to disarm all areas the user can access from any keypad.

Invisible walk test A menu item allows the user to test invisible 24-hour points within the scope of the keypad without sending a report to the central station.

System users The system supports up to 1000 users, each can have a passcode, an access token and a wireless keyfob.

User passcodes contain three to six digits. Passcodes can be assigned to one of 14 customized authority levels in each area, and can be restricted to operate only during certain times.

Communication formats The control panel prioritizes and sends reports in Contact ID or Modem IIIa2 communications formats to four route groups. Each group has a programmable primary and backup destination.

The control panel provides flexible communications for most central stations with reporting capabilities such as:

• Individual point numbers

• Opening or closing reports by user and area number

• Remote programming attempts

• Diagnostic reports

IP communication The control panel uses the B426/B420 Connetix Ethernet Communication Module, DX4020 and/or the ITS‑DX4020‑G Cellular Communicator to communicate with the Conettix D6600 and D6100i Communications Receiver/Gateways. Using Conettix IP communication offers a secure path that includes anti-replay/anti-

2 | D9412GV4 Control Panel substitution features and provides enhanced security with encryption. The B420, DX4020 and ITS‑DX4020‑G can all be used for remote programming.

GV4 is the first Security Control panel to support DNS (Domain Name System) for both remote programming and central station communication. DNS provides ease of use, eliminating the need to use static IP addresses as your reporting destination and accommodates a simple solution for central station disaster recovery.

IP Setup is available via the installer keypad menus and the remote programming software, eliminating the need to use complicated internet programming tools such as ARP and Telnet.

Communication paths The control panel accommodates up to four separate destinations for primary, alternate, and backup receivers for automatic test reports.

When resetting alarms or arming or disarming a system, the user is identified by name and number.

Firmware updates Remote firmware updates using the RPS Firmware Update wizard through the IP connection (B426/B420 Connetix Ethernet Communication Module) as well as an on-site flash update key, provides for easy feature enhancements without replacing ROM chips.

*For GV4 version 2.00 firmware update information, refer to the, “GV4 version 2.00 firmware updates” datasheet to learn more about key enhancements, and supported products.

A wide variety of input options Each point:

• Accommodates normally‑open (NO) and normally‑closed (NC) devices with end‑of‑line (EOL) resistor supervision.

• Is programmable for fire, fire supervisory, or intrusion application.

• Can be hard-wired, addressable, or wireless.

Security and Fire detection The control panel provides eight on‑board points, and up to 238 additional off‑board points. You can program individual points to monitor all types of burglar alarms, fire alarms, and supervision devices.

Scheduled events (SKEDS) The internal clock and calendar start individually scheduled events (SKEDS). SKEDS perform functions such as arm or disarm, relay control, or point bypassing. The D9412GV4 Control Panel offers:

• 40 scheduled events with up to 25 different functions

• Eight opening windows and eight closing windows

• Eight user windows

• Day-of-week, date-of-month, or holiday only schedules

• Four holiday schedules of 366 days each (leap year)

Access control The control panel provides custom door strike, point shunt and auto disarming response by area. There are 14 panel-wide access levels with both manual and scheduled control.

Store, view, or print access events such as:

• Access granted

• No entry

• Request to enter

• Request to exit

Wireless interface The B820 SDI2 Inovonics Interface Module connects an Inovonics EN4200 Serial Receiver to the control panel SDI2 bus, allowing this UL Listed wireless system to be programmed locally via the panel keypad, as well as remotely through RPS.

Event log The event log stores up to 1,000 local and transmitted events. The event log includes time, date, event, area, point, user number, and transmission status. View the event log from a keypad or use RPS to remotely retrieve event information. RPS operators can retrieve events periodically using one call, rather than receiving several calls each day. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver.

Fire test When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. The keypad and annunciator show all testing data. An automatic sensor reset feature saves time; you do not need to reset the sensors manually. At the end of test, the keypad shows the number of untested points.

Programming, diagnostics and controls Installers can program locally or remotely through RPS as well as basic keypad programming. A programmable system passcode prevents unauthorized remote programming.

Two data buses GV4 provides 2 data buses which support a wide array of components. The SDI bus supports keypads, access, and communications modules and also allows connection of existing components in a retrofit application. The new SDI2 bus supports input and output devices as well as a new wireless interface module, and an Ethernet communicator. SDI2 allows these devices to be mounted up to 1000 ft (305 m) from the control panel, providing installation convenience and flexibility.

Commercial Fire Alarm support Suitable for Commercial Fire (UL 864, 9th Edition) applications.

Bosch Video Management System integration With Bosch Video Management System (Bosch VMS) and an intrusion system, the VMS operator has a single user interface to monitor and control the intrusion system combined with video surveillance. With Bosch VMS and a control panel, the operator can, for example:

• View videos triggered by intrusion events, including all relevant information such as areas, point, and user show in the display with the event

3 | D9412GV4 Control Panel

• View areas, points, outputs, and doors – with their statuses – on the Bosch VMS map, providing the exact location in the system.

• Turn on (arm) and turn off (disarm) areas.

• Bypass and unbypass points.

• Lock and unlock doors (Bosch VMS 6.0 and higher).

Requirements to integrate Bosch VMS with a control panel:

• A licensed Bosch VMS system using Professional Editions v5.5 or higher or Bosch VMS Enterprise

• Edition v5.5 or higher.

• Expansion license to integrate the intrusion control panel. One license needed per control panel. Order number MBX-XINT-xx for the expansion license added to a Bosch VMS base license. Refer to the Bosch Video Management Software product page on the Bosch website, www.boschsecurity.com.

• Access to Remote Programming Software (RPS).

• Control panel firmware v2.xx

Certifications and approvals

USA:

UL 365 Police Station Connected Burglar Alarm Units and Systems

UL 609 Local Burglar Alarm Units and Systems

UL 636 (NEW) Holdup Alarm Units and Systems

UL 864 Control Units and Accessories for Fire Alarm Systems (Commercial Fire)

UL 985 Household Fire Warning System Units

UL 1023 Household Burglar Alarm System Units

UL 1076 Proprietary Burglar Alarm Units and Systems

UL 1610 Central Station Burglar Alarm Units

ANSI/SIA

CP-01:2010

False Alarm Reduction

FM 3010 Fire Alarm Signaling Systems

CSFM California Office of The State Fire Marshall 7165-1615:0242 Control Unit (Commercial)

FCC Part 15 Class B, Part 68

Region Certification

USA UL 20130918-S1871, UL 864, ANSI/SIA

CP-01-2010, UL 1076, UL 1610, UL

1635, UL 365, UL 609, UL 985, UL

1023, UL 636

CSFM California State Fire Marshal (see our website)

FDNY-

CoA

Region Certification

Canada ULC 20140407-S1871; ULC/ORD-C1076-

M1986, CAN/ULC-S304-06, CAN/ULC-

S303-M91, CAN-ORD-C1023

Brazil ANATEL 1083-12-1855

Installation/configuration notes

Compatible Products

Keypads

D1265 Touch Screen Keypad

D1255 Series Keypads

D1260 Series Keypads

D1256RB Fire Keypad

D1257RB Remote Fire Alarm Annunciator

D720 Series Keypads

D279A Independent Zone Control

Detectors

D278S Four‑wire Addressable Detector Base, 12 VDC

D285/TH Photoelectric Smoke Detector Heads

D298S Addressable Detector Base, 24 VDC

D7050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads

F220‑B6PM/S 12/24 VDC Addressable Detector Bases with POPITs

FCC-380 Carbon Monoxide Detector

MX775i Addressable PIR Detector

MX794i Long Range Multiplex PIR Detector

MX934i Addressable PIR Detector

MX938i Addressable PIR Detector

ZX776Z PIR Detector

ZX794Z Long Range PIR Detector

ZX835 TriTech Microwave/PIR Detector

ZX935Z PIR Detector

ZX938Z PIR Detector

ZX970 PIR/Microwave Detector

Bosch conventional detectors, including Professional Series, Blue Line Gen2, Blue Line, Classic Line, Commercial Line, and Ceiling Mount motion detectors, as well as glass break, seismic, request-to-exit, photoelectric, heat, and smoke detectors.

Enclosures

D8103 Universal Enclosure

4 | D9412GV4 Control Panel

D8108A Attack‑resistant Enclosure

D8109 Fire Enclosure

Magnetic Contacts

Bosch magnetic contacts include recessed, terminal connection, miniature, overhead door, and surface mount.

Modules

Conettix B426 Ethernet Communication Module (NEW)

B208 Octo-input Module

B308 Octo-output Module

B520 Auxiliary Power Supply Module (NEW)

B820 SDI2 Inovonics Interface Module

Conettix B420 Ethernet Communication Module

Conettix ITS‑DX4020-G Cellular Integrated Communicator

Conettix DX4020 Network Interface Module

Conettix DX4010V2 USB/Serial Interface Module

Conettix C900V2 Dialer Capture Module

D113 Battery Lead Supervision Module

D125B Dual Class B Initiating Module

D126 Standby Battery (12V, 7 Ah)

D127 Reversing Relay Module

D129 Class A Initiating Module

D130 Auxiliary Relay Module

D185 Reverse Polarity Signaling Module

D161 Phone Cord

D162 Phone Cord

D192G Notification Appliance Circuit Module

D928 Phone Line Switcher

D5060 MUX Programmer

D8125 POPEX Point Expander

D8128D OctoPOPIT Eight‑point Expander

D8125MUX Point Expander

D8125INV Wireless Interface Module

D8129 Octo‑relay Module

D8130 Door Release Module

D9127 Series POPIT Modules

D9210C Access Control Interface Module

DS7432 Eight‑input Remote Module

DS7457i Series Single‑zone Multiplex Input Modules

DS7460i Two‑input Module

DS7461i Single‑input Multiplex Module

DS7465i Input and Output Module

ICP-SDI-9114 SDI Splitter

Transformers

D1640 Transformer

D1640-CA Transformer

Programming

RPS or RPS‑LITE Remote Programming Software

Readers

ARD‑R10 iCLASS Mullion Reader

ARD‑R40 iCLASS Switchplate Reader

ARD‑RK40‑09 iCLASS PIN Reader

ARD‑VSMART iCLASS Reader

D8223 Prox Pro Reader

D8224 Mullion Reader

D8224‑SP Switch Plate Reader

D8225 Mini Mullion Reader

D8301W Low‑profile Proximity Readers

Wireless

Inovonics wireless

B820 SDI2 Inovonics Interface Module

ENKIT-SDI2 Inovonics Interface and Receiver Kit. Includes B820 and

EN4200

EN1210 Universal Transmitter (Single-input)

EN1210EOL Universal Transmitter with EOL Resistor

EN1210W Door-Window Transmitter with Reed Switch

EN1215EOL Universal Transmitter with Wall Tamper, Reed Switch, and EOL Resistor

EN1223D Water‑resistant Pendant Transmitter (Double‑button)

EN1223S Water‑resistant Pendant Transmitter (Single‑button)

EN1224-ON Multiple-Condition Pendant Transmitter

EN1233D Necklace Pendant Transmitter (Double-button)

EN1233S Necklace Pendant Transmitter (Single-button)

EN1235D Beltclip Pendant Transmitter (Double-button)

EN1235DF Fixed-location Transmitter (Double-button)

EN1235S Beltclip Pendant Transmitter (Single-button)

5 | D9412GV4 Control Panel

EN1235SF Fixed-location Transmitter (Single-button)

EN1247 Glass-break Detector Transmitter

EN1249 Bill Trap Transmitter

EN1242 Smoke Detector Transmitter

EN1260 Wall Mount Motion Detector

EN1261HT High Traffic Motion Detector

EN1262 Motion Detector with Pet Immunity

EM1265 360° Ceiling Mount Motion Detector

EN4200 Serial Receiver

EN5040-T High Power Repeater with Transformer

Parts included

The D9412GV4 includes the following parts:

Quant. Component

1 D9412GV4

1 Faceplate with D9412GV4 Label

1 Literature pack

• Installation Instructions

• Owners Manual

• Release Notes

1 Literature CD containing all product literature

The available kits come with the parts indicated in the following table:

Kits

Components ‑A ‑B ‑C

D9412GV4 1 1 1

D122 Dual Battery Harness 1

D161 Dual Modular Phone Cord 2

D928 Dual Phone Line Switcher 1

D1640 Transformer 1 1

D8103 Enclosure 1

D8108A Attack‑resistant Enclosure 1

D8109 Fire Enclosure 1

D101 Lock and Key Set 1 1

D101F Lock and Key Set 1

Technical specifications

Communications

Telephone Connection:

• One telephone line

• D928 Dual Phone Line Module required for two telephone lines

Environmental Considerations

Relative Humidity: 5% to 93% at +30°C (+86°F), non‑condensing

Temperature (Operating): 0°C to +50°C (+32°F to +122°F)

Number of…

Areas: 32

Card Readers (Doors): 8

Credentials (Tokens): 999

Custom Functions: 16

Events: Up to 1000

Passcode Users: 999, plus 1 service passcode

Parallel Printers: 3

Points: 246 (8 on‑board, up to 238 off‑board)

Programmable Relay Outputs: 131

RF Points: 238

SKEDs: 40

Power Requirements

Current Draw (Maximum): 300 mA

Output (Alarm): 2 A at 12 VDC

Output (Auxiliary, Continuous Power, and Switched Auxiliary combined):

1.4 A at 12 VDC nominal

Voltage (Operating): 12 VDC nominal

Voltage (AC): 16.5 VAC 40 VA plug‑in transformer (D1640)

Ordering information

D9412GV4 Control Panel The D9412GV4 is sold individually or in kits. It supports 246 points.

Order number D9412GV4

D9412GV4-A Attack-resistant Package Contains one PCB, one transformer, and one attack-resistant enclosure.

Order number D9412GV4-A

D9412GV4-B Fire/Burglar Package Contains one PCB, one dual battery harness, two telephone cords, one telephone line switcher, one transformer, and one fire enclosure.

Order number D9412GV4-B

6 | D9412GV4 Control Panel

D9412GV4-C Standard Burglar Package Contains one PCB, one lock and key set, one transformer, and one universal enclosure.

Order number D9412GV4-C

Accessories

B520 Auxiliary Power Supply Module Provides auxiliary power to 12 VDC devices or to SDI2 modules.

Order number B520

B208 Octo-input Module Provides 8 programmable inputs.

Order number B208

B308 Octo-output Module Provides 8 programmable relays.

Order number B308

SDI2 Inovonics Interface and Receiver Kit Kit containing B820 and EN4200 for use on SDI2 bus panels.

Order number ENKIT-SDI2

D122 Dual Battery Harness Harness with circuit breaker. Connects two batteries to a compatible control panel.

Order number D122

D122L Dual Battery Harness with Long Leads Color-coded harness with circuit breaker and leads measuring 89 cm (35 in.). Connects 12 V batteries to compatible control panels.

Order number D122L

D126 Standby Battery (12 V, 7 Ah) A rechargeable sealed lead‑acid power supply used as a secondary power supply or in auxiliary or ancillary functions.

Order number D126

D1218 Battery (12 V, 18 Ah) A 12 V sealed lead‑acid battery for standby and auxiliary power with two bolt‑fastened terminals.

Includes hardware for attaching battery leads or spade connectors Order number D1218

D137 Mounting Bracket Used to mount accessory modules in D8103, D8108A, and D8109 enclosures.

Order number D137

D138 Mounting Bracket, Right Angle Used to mount accessory modules in D8103, D8108A, and D8109 enclosures.

Order number D138

D1640 Transformer System transformer rated at 16.5 VAC, 40 VA.

Order number D1640

D8004 Transformer Enclosure For applications such as fire alarm that might require a transformer enclosure.

Order number D8004

D9002‑5 Mounting Skirt 5 pack of mounting skirts for B8103, D8103, D8108A, and D8109 enclosures. Each skirt can hold up to six standard 3-hole mounting modules.

Order number D9002-5

D101 Lock and Key Set Short-body lock set with one key supplied. Uses the D102 (#1358) replacement key.

Order number D101

D110 Tamper Switch Screw‑on tamper switch that fits all enclosures.

Shipped in packages of two.

Order number D110

ICP‑EZTS Dual Tamper Switch Combination tamper switch with a wire loop for additional tamper outputs.

Order number ICP-EZTS

D8108A Attack Resistant Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. Includes a lock and key set.

Order number D8108A

D8103 Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.).

Order number D8103

D8109 Fire Enclosure Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock and key set.

Order number D8109

BATB-40 Battery Box\Enclosure The BATB-40 Battery Box holds two dry or wet cell batteries. The box can be used with fire alarm systems or intrusion systems.

Order number BATB-40

BATB-80 Battery Box\Enclosure with Shelf The BATB-80 Battery Box holds up to four dry or wet cell batteries. The box can be used with fire alarm systems or with intrusion systems.

Order number BATB-80

D928 Dual Phone Line Switcher Allows the control panel to operate over and supervise two separate phone lines. Only one D162 phone cord is supplied. Two additional D161 or D162 phone cords are required.

Order number D928

7 | D9412GV4 Control Panel

Software Options

RPS Kit (DVD-ROM and USB Security Block) Account management and control panel programming software with USB security key (dongle).

Order number D5500C-USB

8 | D9412GV4 Control Panel

Represented by:

Europe, Middle East, Africa: North America: Asia-Pacific:

Bosch Security Systems B.V.

P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com

Bosch Security Systems, Inc.

130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us

Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia

© Bosch Security Systems 2016 | Data subject to change without notice 2495537803 | en, V19, 21. Jul 2016

The 1006 series is the strongest and most versatile electric strike available. The dual interlocking plunger design and heavy duty stainless steel construction, enables it to exceed every standard developed for electric strikes. With multiple faceplate options, the 1006 will fully accommodate every lock designed to work within an ANSI 4-7/8" strike plate. Tested to exceed 3,000 lbs. of static strength, 350 ft-lbs. of dynamic strength and factory tested to exceed 1,000,000 cycles of operation, the 1006 is in a class of its own.

Specifications

• UL 10C fire-rated, 3 hour single door (fail secure only)

• UL 10C fire-rated, 1-1/2 hour double door (fail secure only)

• CAN4-S104(ULC-S104)

fire door conformant

• ANSI A250.13-2003

windstorm listed

• UL 1034, burglary-resistant listed and suitable for outdoor use

• UL 294 (6th Edition) listed

• ANSI/BHMA A156.31,

Grade 1

• NFPA-252 fire door conformant

• ASTM-E152 fire door conformant

• MEA New York City accepted

• Florida Building Code approved FL#4776

• RoHS compliant

• Environmental

Product Declaration

• Patents: 6,021,038

& 6,595,564

Frame Application

• Metal

• Wood

Electrical (continuous duty)

• .45 Amps at 12 VDC

• .25 Amps at 24 VDC

Shown with KM Option

Series The strongest, most versatile electric strike available

The 1006 Series is also available in a Complete One Box Solution

1006 Models 1006 Universal electric strike Faceplate options ordered separately, see pages 12-16

1006CS Complete electric strike

Includes the SMART Pac II and J, KD, KM, HM, and AD faceplates

1006CLB Complete electric strike Includes the J, K, KD, and KM faceplates

1006CDB Complete electric strike Includes the HM and AD faceplates

RF1016 Integrated Prox

Includes the strike body, Prox reader and door position switch

IC1026 Integrated iCLASS®

Includes the strike body, iCLASS reader and door position switch

8 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions

IN

TE

G

RA

TE

D

PR

O D

U

CT

S

CA

BI

N

ET

L

O

CK

S

AC

CE

SS

O

RI

ES

G

EN

ER

AL

IN

FO

RM

AT

IO

N

FO

LG

ER

A

D A

M H

ES

G

EN

RM

AT

IO

N

AC

CE

SS

O

RI

ES

CA

BI

N

ET

L O

CK

S

IN

TE

G

RA

D

U

CT

S

FO

LG

ER

A D

A M

H

ES

TEG

RATED

PRO

U

CTS

CABIN

ET LO

CKS

ACCESSO

RIES

G

EN

ERAL

IN

FO

RM

ATIO

N

FO

LG

ER AD

A M

H

ES

Diagram shown with N Option

Standard Features

• Stainless steel construction

• Tamper-resistant

• Static strength 3,070 lbs.

(fail secure)

• Dynamic strength 350 ft-lbs.

(fail secure)

• Endurance 1,000,000 cycles

• Fail secure

• Dual-voltage 12 VDC or 24 VDC continuous duty

• Non-handed

• Internally mounted solenoid

• Accommodates up to 1" deadbolt

• Plug-in connector

• Full keeper shims for horizontal adjustment

• Trim enhancer

• Five-year limited warranty

Optional Features LBM » Latchbolt monitor LBSM » Latchbolt strike monitor

• Fail safe

• Interchangeable faceplates Monitor Switches may not work with all faceplate options (see pages 12-16)

Accessories 1000-102 » Rain guard 1006-103 » Full keeper shims 1000-104 » Lip extension trim adapter 1006-105 » Trim enhancer BLK (goof plate) 1006-109 » Trim adapter 1000-110 » Replacement strike plate 1000-130 » KD filler plate

150 » Strike latch guard 154-MTK » Metal template kit 2004M » ElectroLynx® adapter 2005M3 » SMART Pac® III 2006M » Plug-in buzzer

Finishes 630 » Satin stainless steel 605 » Bright brass 606 » Satin brass 612 » Satin bronze 613 » Bronze toned 629 » Bright stainless steel BLK » Black *Complete Pacs are only available in the 630 finish

[104.8] 4-1/8"

[85] 3-3/8"

[123.4] 4-7/8"

[42.7] 1-11/16"

[85] 3-3/8"

[52.4] 2-1/16" [44.5]

1-3/4"

Customer Support 800.626.7590 9© 2016, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.

FO

LG

ER AD

A

M

IN

U

CTS

CABIN

ET LO

CKS

ACCESSO

RIES

G

EN

ERAL

IN

FO

RM

ATIO

N

1006 C LB F 630 LBM

Strike Series Complete Lock Type Fail Safe/Secure Finishes Optional Features

Choose the electric strike series number

Specify a “C” to include select faceplates and hardware in the box

“LB” for Latchbolt “S” for

SMART Pac III “DB” for Deadbolt

Specify an “F” for Fail Safe and leave blank for

Fail Secure (standard)

All Complete Pacs are only available in the 630 finish

This item refers to options such as latchbolt monitor or latchbolt strike monitor

Series HES raises the bar again with a Complete line of One Box Solutions

How to Order Part Number Examples

The following is an example describing how to order the new 1006 Complete One Box Solutions.

1006CLB-630-LBM

Is the part number for a 1006 Series electric strike with select option faceplates included in the box, and a stainless steel finish.

If you’re unsure of what lockset you’ll encounter in the field or just want to simplify what you carry, choose an HES Complete electric strike system.

You'll be sure to have a Grade 1 solution to release any cylindrical or mortise lockset that works with an ANSI 4-7/8" strike plate.

Everything is included in the box.

10 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions

IN

TE

G

RA

D

U

CT

S

CA

BI

N

ET

L

O

CK

S

AC

CE

SS

O

RI

ES

G

EN

RM

AT

IO

N

FO

LG

ER

A

D A

M H

ES

G

EN

RM

AT

IO

N

AC

CE

SS

O

RI

ES

CA

BI

N

ET

L O

CK

S

IN

TE

G

RA

D

U

CT

S

FO

LG

ER

A D

A M

U

CTS

CABIN

ET LO

CKS

ACCESSO

RIES

G

EN

ERAL

IN

FO

RM

ATIO

N

FO

LG

ER AD

A M

H

ES

The 1006CS Smart Strike includes a 1006 electric strike body and SMART Pac® III plus faceplates and brackets that can provide the same function as any of the following options:

J Option K Option KD Option KM Option A Option AD Option

AM Option H Option HD Option HM Option HT Option HTD Option

N Option ND Option NM Option T Option TD Option

1006CS

Smart Strike™

The Complete One Box Solution for all cylindrical and mortise locksets, with or without a 1" deadbolt

Compatible Locksets:

Compatible Locksets:

Compatible Locksets:

1006CLB

Complete for Latchbolt Locks The Complete One Box Solution for all cylindrical and mortise locksets The 1006CLB includes the 1006 electric strike body plus faceplates and brackets that provide the same function as any of the following options:

J Option K Option

KD Option KM Option

1006CDB

Complete for Deadbolt Locks The Complete One Box Solution for all locksets with a 1" deadbolt The 1006CDB includes the 1006 electricstrike body plus faceplates and brackets that provide the same function as any of the following options:

A Option AD Option AM Option H Option HD Option

HM Option HT Option HTD Option N Option ND Option

NM Option T Option TD Option

*Complete Pacs are only available in the 630 finish

10 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions Customer Support 800.626.7590 11© 2016, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.

FO

LG

ER AD

A

M

IN

U

CTS

CABIN

ET LO

CKS

ACCESSO

RIES

G

EN

ERAL

IN

FO

RM

ATIO

N

1006 Series Faceplate Options

Operation: After releasing the latchbolt, the keeper returns to the locked position

4-7/8" × 1-1/4"

LB Option The Latchbolt Solution: Includes all hardware to accommodate every cylindrical and mortise lock up to a 3/4" latchbolt.

Replaces function of the J, K, KM and KD Options

» ANSI/BHMA Numbers: E09321, E09322, E09323

Operation: This deadbolt solution offers three modes of functionality; night latch, lockout, and normally extended deadbolt. (Functional operation modes described below.)

DB Option The Deadbolt Solution: Includes all hardware to retain, release and recapture all mortise locks, and tubular deadbolts up to a 1" latchbolt Mode 1: Night latch function. The deadbolt is retracted during traffic hours.

The latchbolt is released by the keeper and keeper returns to the locked position.

Mode 2: Lockout function. The electric strike will not release if the deadbolt is extended.

Mode 3: Normally extended deadbolt. Latchbolt and deadbolt are released by a single keeper. The keeper is held open to recapture the latchbolt and deadbolt when the door is closed.

Replaces function of the N, ND, NM, A, AM, AD, T, TD, H, HD, HM, HT, and HTD options

» ANSI/BHMA Numbers: E09391, E09392, E09393, E09331, E09332, E09333

SPECIALTY Operation: After releasing the latchbolt or deadbolt the keeper returns to the locked position

4-7/8" × 1-1/4"

E Option For use with: Corbin Russwin Security Bolt, Weiserbolt and normally extended 1" tubular deadbolts

» ANSI/BHMA Numbers: E09391, E09392, E09393

“For use with” information is offered as a recommendation only. Reference should be made to the lockset manufacturer for proper installation instructions necessary to meet compatibility requirements.

12 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions

IN

TE

G

RA

D

U

CT

S

CA

BI

N

ET

L

O

CK

S

AC

CE

SS

O

RI

ES

G

EN

RM

AT

IO

N

FO

LG

ER

A

D A

M H

ES

FO

LG

ER

A D

A M

IN

TE

G

RA

D

U

CT

S

CA

BI

N

ET

L

O

CK

S

AC

CE

SS

O

RI

ES

G

EN

RM

AT

IO

N

U

CTS

CABIN

ET LO

CKS

ACCESSO

RIES

G

EN

ERAL

IN

FO

RM

ATIO

N

FO

LG

ER AD

A M

H

ES

1006 Series Faceplate Options

SPECIALTY

Operation: The hookbolt is released by a single keeper. The keeper is held open to recapture the latchbolt and hookbolt when the door is closed.

4-7/8" × 1-1/4"

R Option For use with: Adams Rite style hookbolt up to 1" throw

» ANSI/BHMA Numbers: E09391, E09392, E09393, E09332, E09333

SPECIALTY Operation: After releasing the latchbolt, the keeper returns to the locked position

4-7/8" × 1-1/4"

Z Option For use with: Unit and Mono locks

» ANSI/BHMA Numbers: E09321, E09322, E09323

Operation: After releasing the latchbolt, the keeper returns to the locked position

9" × 1-3/8"

J-2 Option For use with: All cylindrical locks up to a 3/4" latchbolt

» ANSI/BHMA Numbers: E09321, E09322, E09323

Operation: After releasing the latchbolt, the keeper returns to the locked position

9" × 1-3/8"

KM-2 Option For use with: Mortise locksets up to a 3/4" latchbolt

» ANSI/BHMA Numbers: E09321, E09322, E09323

Continued on next page »“For use with” information is offered as a recommendation only. Reference should be made to the lockset manufacturer for proper installation instructions necessary to meet compatibility requirements.

12 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions Customer Support 800.626.7590 13© 2016, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.

G

EN

ERAL

IN

FO

RM

ATIO

N

ACCESSO

RIES

CABIN

ET LO

CKS

IN

U

CTS

FO

LG

ER AD

A M

1006 Series Faceplate Options

Operation: This deadbolt solution offers three modes of functionality; night latch, lockout, and normally extended deadbolt. (Functional operation modes described below.)

9" × 1-3/8"

DB-2 Option The Deadbolt Solution: Includes all hardware to retain, release and recapture all mortise locks, and tubular deadbolts up to a 1" latchbolt Mode 1: Night latch function. The deadbolt is retracted during traffic hours.

The latchbolt is released by the keeper and keeper returns to the locked…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .