This federal contract opportunity notice seeks proposals for an OPM Office Renovation design-build project located at the Fort Lauderdale Federal Building & Courthouse. The General Services Administration Public Buildings Service Region 4 is soliciting proposals for approximately 1646 square feet of office space renovation including architectural, access controls, intrusion detection system, intercom, door, electrical, and communications requirements. Interested vendors must pre-register by 15 April 2021 to attend the site visit on 21 April 2021 and submit questions by 26 April 2021. Proposals are due by 14 May 2021. This 100% set-aside acquisition for Service Disabled Veteran Owned Small Business concerns is estimated between $250,000 to $500,000. The total design and construction period of performance is 210 days from notice to proceed.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JO Series Video IntercomVVVVViiiiidddddeeeeeooooo IIIIInnnnndeodeo ttttteeeeerrrrrcccccooooorrrrrrr mmmmm
Slim Design ▪ 7" Screen
Door Entry Security
JO Series 7" Video Intercom
7" Screen Actual Size
• Touch Buttons A light touch is all that is required to control the system
• Improved Picture Quality New door station camera provides clear visitor images for reliable identifi cation
• Elegant Styling Sleek design matches home or business decors
• Cost Eff ective A quality solution at a reasonable price
• 2-Conductor Wiring Can be installed using existing doorbell wire
Screen images simulated
2 | JO Series
Control with Touch Buttons
3-Way Communication All stations can communicate simultaneously to assist visitors*
* The JO Series does not support internal communication. The JO-1MD and the JO-1FD can only converse together when they are both in active communication with the door station.
JO-1MD
JO-1FD
Perfect for
Offi ces
Stylish for
Homes
JOS-1V Box Set
Security, convenience, and style all rolled into one! The contemporary design complements today’s homes.
The JO Series helps to identify visitors, colleagues, appointments, or potential threats at an entrance.
| 3
Monitor Discreetly view entrances to view possible disturbances
Volume Select communication and door call-in volume
LCD Adjustment Select screen brightness
Secondary Device Control optional devices, such as exterior lights, gates, etc.
Door Release Easily unlock a door or an entrance
Hands-Free Communication Touch to activate hands-free
VOX communication or press and hold to switch to PTT mode
#91271 JO Series Brochure
03 / 2016
Printed in USA
Aiphone Co. Ltd.
Deming Prize
Aiphone Corp.
ISO 9001:2008
Certified
The information in this brochure is subject to change without notice. Aiphone Co. Ltd.
ISO-14001
Certified
Copyright © 2016. All Rights Reserved • T: (800) 692-0200 • F: (800) 525-3372 • www.aiphone.com |
Door Station* | JO-DVF: Video door station, stainless steel, flush mount
H: 8-1/4" W: 5-5/16" D: 1-7/8"
Master Station* | JO-1MD: Video intercom master station with touch buttons
H: 5-1/8" W: 9-1/16" D: 13/16"
Power Supply | PS-1820UL: Power supply
JOS-1F Box Set
AC-10S
Access control keypad, zinc die cast to match
JO-DV, surface mount
Master StationAdd-on Station
JO-DV
2 2
6 2
330’ 330’ Door Station
Secondary Output Control
JO DV
IER-2
2 2 2
Secondary Output Control
IER-2IER 2
JO-1MD
PS-1820UL
JO-1FD
PT
: PT-1210N TransformerPT
Door Station Master Station
JO-DV
330’ 2 2
JO DV
IER-2
PT
Start with a box set
WiringWiring
Begin by selecting a JO Series Box Set. To have a secondary station communicate and control the door station, install a JO-1FD.
Each set contains a JO-1MD master station, door station, and PS-1820UL power supply. Just add wire!
* Door stations and JO-1MD are not sold separately
Includes:
Door Station* | JO-DV: Video door station, zinc die cast, surface mount
H: 6-13/16"W: 3-7/8" D: 1-1/16"
Master Station* | JO-1MD: Video intercom master station with touch buttons
H: 5-1/8" W: 9-1/16" D: 13/16"
Power Supply | PS-1820UL: Power supply
JOS-1V Box Set
Door Station* | JO-DA: Video door station, plastic, surface mount
H: 5-1/16" W: 3-13/16" D: 1-3/8"
Master Station* | JO-1MD: Video intercom master station with touch buttons
H: 5-1/8" W: 9-1/16" D: 13/16"
Power Supply | PS-1820UL: Power supply
JOS-1A Box Set
Includes: Includes:
RY-ES
External signaling relay
Add-on Station 1 per system
Accessories
JO-1MD only
JO-1MD and JO-1FD
JO-1FD
Video intercom expansion station with touch buttons
H: 5-1/8" W: 9-1/16" D: 13/16"
IER-2
Call extension speaker
MCW-S/A
Inside station desk stand
Additional ComponentsWiring
JO Series Components
2 2
Secondary Output ControlPS-1820UL
JO-1MDJO 1MD
interlogix.com
High Security Surface Mount Magnetic Contacts 2700 Series
The 2700 Series High Security magnetic contacts with triple-biased reeds are highly resistant to defeat by external magnets. For added security, magnetic field tamper and pry tamper are standard features. Each 2700 contact and actuation magnet set is factory compensated for the effects of steel. All 2700 Series contacts are accepted by the Defense Intelligence Agency. They are listed in DIAM 50-3 for use in secure compartmented information facilities (SCIFs). 2700 Series High Security magnetic contacts are UL listed. Two models are listed for use on safes and vaults.
The 2700 Series can be used to protect doors in high security locations or where high value materials are stored. They have effectly been used at airports, biotechnology labs and other medical research settings, warehouses, manufacturing plants, jewelry stores, banks, data processing centers, military bases, ammunition depots and energy-generation facilities.
2707A/2707AD
The switches contains three independent Form C biased reed contacts, wired in SPDT configuration (model 2707A);
or six independent Form C biased reed contacts, wired in DPDT configuration (model 2707AD). A supervised loop with a magnetic tamper feature is included on both models. A pry tamper connection is also available for the 24-hour loop.
2706AP/2706AS
The switches contain three independent Form C biased reed contacts, wired in SPDT configuration. A supervised loop with a series magnetic tamper and pry tamper are also included. Both models conform to Class IV Preadjusted Balanced Magnetic Contacts specifications. A remote test feature is provided in the protective loop (AP models) or in the supervised loop (AS models).
Overview
• Triple biased for increased security
• No field adjustment
• Pry tamper included
• Supervision and remote test options available
• UL listed for safes and vaults – 2707A, 2707AD
Standard FeatureS
Intrusion
High Security Surface Mount Magnetic Contacts 2700 Series
North America T 855-286-8889
Asia T 852-2907-8108
Australia T 61-3-9239-1200
Europe T 32-2-725-11-20
Latin America T 561-998-6114 interlogix.com
Specifications subject to change without notice.
© 2013 Interlogix.
All rights reserved.
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.
306-3687 2013/07 (75105)
Dimensional Diagram
Magnet
1.50 in.
38.1mm
.75 in.
19.1mm
4.25 in.
108mm
3.50 in.
88.9mm
1.50 in.
38.1mm
.75 in.
19.1mm
.16 in.
4.1mm dia.
.38 in.
9.7mm
.38 in.
9.7mm
UL®
LISTED
Specifications Voltage 30V AC/DC maximum Current 0.25A maximum Power 3.0W maximum Dimensions (LxWxH) 4.25 x 1.50 x .75 in. (10.80 x 3.81 x 1.91 cm) Material Brushed anodized aluminum Listing UL-634
Ordering Information
2706AP-L
High Security Contacts w/Armored Cable, Triple Biased, SPDT, Remote Test- Protective Loop, 3/16” to 5/8” Gap Size, Single Pole-Double Throw, 3’ Stainless Steel Armored Cable
2706AS-L
High Security Contacts w/Armored Cable, Triple Biased, SPDT, Remote Test- Supervised Loop, 3/16” to 5/8” Gap Size, Single Pole-Double Throw, 3’ Stainless Steel Armored Cable
2707AD-L High Security Contacts w/Armored Cable, Triple Biased, DPDT, 3/16” to 5/8” Gap Size, Double Pole-Double Throw, 3’ Stainless Steel Armored Cable
2707AD-L5 High Security Contacts w/Armored Cable, Triple Biased, DPDT, 3/16” to 5/8” Gap Size, Double Pole-Double Throw, 5’ Stainless Steel Armored Cable
2707A-L High Security Contacts w/Armored Cable, Triple Biased, SPDT, 3/16” to 5/8” Gap Size, Single Pole-Double Throw, 3’ Stainless Steel Armored Cable
Intrusion Alarm Systems | D1255 Series VFD Keypads
D1255 Series VFD Keypads www.boschsecurity.com u Easy to read vacuum fluorescent display (VFD) u Easy system control with menu keys u User controlled brightness and volume u Installer configured menus, text, and custom functions u Multiple or single area configurations
Each D1255 Series VFD Keypad model is an SDI bus compatible device that works with the G Series Control Panels and the D9124 Addressable Fire Alarm Panel. Each keypad model has an illuminated keypad, 16-character English language vacuum fluorescent display (VFD), and a sounder that emits eight tones.
System overview
Use D1255 Series Keypad models in applications for system controllers and annunciators:
• For commercial use, install the keypad in building entrances and areas with unrestricted access.
Mounting a keypad near exterior doors in hotel or business lobbies allows people to identify the type and location of the emergency.
• For residential use, install the keypad near the front and rear entrances to the home. Install additional keypads in a kitchen or in a bedroom.
• Use multiple keypads in a large building with many separate areas of security. Program multiple keypads to control multiple areas.
• Install the keypad in locations that are hidden from view. Audible tones from the keypad sounder alert personnel to fire events and assist fire fighters in locating the keypad.
Functions
Display Every D1255 Series Keypad model uses words, numbers, and symbols to show the status of the security system. When several events occur, each model shows each event in order of priority.
Keys Each D1255 Series Keypad model has 10 numeric keys and five function keys. Use the [COMMAND] key with the numeric keys to perform a function. Use the [ENT] key or [YES] key to enter your passcode. When pressed, each key emits light and a muted beep.
Audible Tones The sounder emits eight distinct warning tones. You can adjust the volume or use a passcode to silence the tone. The tones include:
• Burglary Signal: Steady high-pitched bell tone during alarm.
• Fire Signal: Pulsed high-pitched bell tone during fire alarm.
• Entrance Warning: Intermittent beep tones during entry delay periods.
• Exit Warning: Intermittent beep tones during exit delay periods.
• Invalid Key Buzz: Buzz tone when an invalid key is pressed.
• Keypad Encoding Tone: Muted beep tone as each key is pressed.
• Trouble Buzzer: Two-tone warble during a trouble event.
• Watch Tone: Intermittent beep tone when a watch point is faulted.
Certifications and approvals
Region Certification
USA UL D1255: AMCX: Central Station Alarm Units (UL1610, UL1635), AMCX7: Cen-tral Station Alarm Units Certified for Can-ada (cULus), AMTB: Control Panels, SIA False Alarm Reduction, AOTX: Local Alarm Units (UL464, UL609), AOTX7:
Local Alarm Units Certified for Canada (cULus), APAW: Police Station Alarm Units (UL365, UL464), APAW7: Police Station Alarm Units Certified for Canada (cULus), APOU: Proprietary Alarm Units (UL1076), APOU7: Proprietary Alarm Units Certified for Canada (cULus), NBSX: Household Burglar Alarm System Units (UL1023), NBSX7: Household Burglar Alarm System Units Certified for Canada (cULus), UTOU: Control Units and Accessories - Household System Type (UL985), UTOU7: Control Units and Accessories - Household System Type Certified for Canada (cULus)
UL D1255W: AMCX: Central Station Alarm Units (UL1610, UL1635), AMTB: Con-trol Panels, SIA False Alarm Reduction, AOTX: Local Alarm Units (UL464, UL609), APAW: Police Station Alarm Units (UL365, UL464), APOU: Propriet-ary Alarm Units (UL1076), NBSX:
Household Burglar Alarm System Units (UL1023), UTOU: Control Units and Ac-cessories - Household System Type
(UL985)
FM D1255
CSFM see our website
NYC-
MEA
D1255: 12-92-E, Vol. IV 12-92-E, Vol.
IV
NYC-
MEA
D1255: 12-92-E, Vol. 12 12-92-E, Vol.
NYC-
MEA
D1255: 12-92-E, Vol. 15 12-92-E, Vol.
Canada ULC D1255B: AMCX7: Central Station Alarm Units Certified for Canada (cUL), AOTX7: Local Alarm Units Certified for Canada (cUL), APAW7: Police Station Alarm Units Certified for Canada (cUL), APOU7: Proprietary Alarm Units Certi-fied for Canada (cUL), NBSX7: House-hold Burglar Alarm System Units Certi-fied for Canada (cUL), UTOU7: Control Units and Accessories - Household Sys-tem Type Certified for Canada (cUL)
ULC AMCX7.S1871 - Central Station Alarm Units Certified for Canada
Region Certification
ULC APOU7.S1871 Proprietary Alarm Units Certified for Canada
ULC AOTX7.S1871 Local Alarm Units Certi-fied for Canada
ULC APAW7.S1871 Police-station-connec-ted Alarm Units Certified for Canada
ULC NBSX7.S1871 Household Burglar Alarm System Units Certified for Canada
ULC AMCX.S1871, AMCX7.S1871,
AMTB.S1871, AOTX.S1871,
AOTX7.S1871, APAW.S1871,
APAW7.S1871, APOU.S1871,
APOU7.S1871, NBSX.S1871,
NBSX7.S1871, UTOU.S1871, [D1255
VFD]
Installation/configuration notes
Compatible Control Panels
• B9512G/B9512G-E
• B8512G/B8512G-E
• D9412GV4/D7412GV4/D7212GV41
• D9412GV3/D7412GV3/D7212GV31
• D9412GV2/D7412GV2/D7212GV21
• D9412G/D7412G/D7212G
• D9412, D7412, D7212, and D9112 with firmware versions 6.40 or higher
• D9124
1The D7212GV4, D7212GV3, D7212GV2, D7212G are not listed for commercial fire applications.
Mounting Considerations
• Do not mount any of the D1255 Series Keypad models in a location exposed to direct sunlight.
Direct sunlight can interfere with screen visibility and damage internal components.
• Do not mount any of the D1255 Series Keypad models in damp locations.
Power Supplies A compatible control panel supplies the power and data requirements to a D1255 Series Keypad model through a four-wire connection.
Wiring Considerations Use 0.8 mm (22 AWG) or 1.2 mm (18 AWG) wire.
Resistance cannot exceed 25 Ω. Each D1255 Series Keypad model includes a wiring assembly of four color-coded flying leads and one female four-pin connector.
Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Parts included
Quant. Component
1 Keypad
2 | D1255 Series VFD Keypads
1 Hardware pack (3 screws and 3 anchors)
1 Literature pack
• Pull-up Reference Card
• Users Guide
• Installation Guide
Technical specifications
Connections
Connections: 4-wire flying lead for data and power
Resistance: 25 Ω maximum
Environmental Considerations
Temperature (Operating): 0°C to +50°C (+32°F to +122°F)
Relative Humidity: 5% to 85% at +30°C (+86°F)
Keypad
Dimensions for D1255, D1255W, and D1255R:
11.7 cm x 21 cm x 2 cm (4.6 in. x 8.2 in. x 0.8 in.)
Dimensions for D1255B: 12.6 cm x 20 cm x 3.2 cm (5 in. x 7.9 in. x 1.3 in.)
Weight for All Models: 439 g (15.5 oz)
Material for All Models: CHI MEI POLYLAC PA757 ABS with UV Stabilizer. UL94-HB Fire Rated
Display Window: 16-character vacuum fluorescent display Each character is a 14-segment unit
Indicators: Illuminated keys Warning and indicating tones
Number of…
D1255 Series Keypad Models per Control Panel:
Eight supervised 32 unsupervised
Power Requirements
Voltage: Nominal 12 VDC
Current: Idle 104 mA, armed or disarmed;
Maximum 206 mA, with keypad lit and warning tone on
Ordering information
D1255 VFD Keypad Off-white classic case.
Order number D1255
D1255W VFD Keypad White classic case.
Order number D1255W
D1255B VFD Keypad White and gray modern case.
Order number D1255B
Accessories
D54B Brass Flush‑mount Kit Back box and polished brass faceplate.
Order number D54B
D54C Stainless Steel Flush‑mount Kit Back box and stainless steel faceplate.
Order number D54C
D55 Keypad Desk Stand Portable desk stand in smoke colored Plexiglas.
Order number D55
D56 Surface Mount Conduit Box White surface mount box.
Order number D56
D56R Red Surface Mount Conduit Box Red surface mount box.
Order number D56R
3 | D1255 Series VFD Keypads
4 | D1255 Series VFD Keypads
Represented by:
North America: Europe, Middle East, Africa: Asia-Pacific: China: Latin America and Caribbean:
Bosch Security Systems, Inc.
130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
203 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com
© Bosch Security Systems 2016 | Data subject to change without notice 2528705803 | en, V9, 18. Mar 2016
Intrusion Alarm Systems | D9412GV4 Control Panel
D9412GV4 Control Panel www.boschsecurity.com u Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three u Conettix IP‑based communication options provide high‑speed, secure alarm transport and control through connection of wired and/or cellular network interfaces u Up to 32 programmable areas, each supporting perimeter and interior points with your choice of touch screen, ATM style, or LED keypads u 246 hardwired, addressable or wireless points with flexible configuration options to meet multiple installation requirements u OPTIONAL GV4 version 2.xx firmware upgrade available
GV4 panels are the premier commercial control panel line from Bosch. GV4 panels integrate intrusion, fire and access control providing one simple user interface for all systems. With the ability to adapt to large and small applications, the D9412GV4 provides up to 246 individually identified points that can be split into 32 areas. The control panel includes a communicator that sends events to selected public switched telephone network (PSTN), IP network, or cellular network destinations through four programmable route groups.
With the D9412GV4 you can:
• Monitor alarm points for intruder or fire alarms while operating keypads and other outputs
• Program all system functions local or remote using Remote Programming Software (RPS) or by using basic programming through the keypad.
• Add up to eight doors of access control using the optional D9210C Access Control Interface Module.
Functions
Programmable outputs
• 2 A alarm power at 12 VDC
• 1.4 A auxiliary power at 12 VDC
• Four alarm‑output patterns
• Programmable bell test
System response
• High-performance micro‑controller provides industry‑leading system response
• High-speed device bus
• 31 custom point indexes, including fire supervisory
• Selectable point response time
• Cross point capability
• Fire alarm verification
• Fire inspector’s local test
• Watch mode
• Scheduled events (SKEDS) arm, disarm, bypass and unbypass points, control relays, control authority levels, and control door access
User interface
• Supervision of up to 16 keypads (up to 32 unsupervised keypads can be used)
• Remote Programming Software (RPS) allows end users to perform control panel management tasks – Add/Delete/Change user passcodes and authorities, view and print the panel history event log
• Custom keypad text is fully programmable, including remote programming
• Full function command menu including Custom Functions
• Authority by area and 16‑character name for each user
• 14 custom authority levels control user’s authority to change, add, or delete passcodes or access control credentials; to disarm or bypass points; and to start system tests
Area configurations Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master or associate). Any area can be configured for perimeter and interior arming, not requiring a separate area for this function.
Custom functions For added convenience, Custom Functions can be programmed to eliminate keystrokes for users allowing the installer to program an easy command for a complicate function. For example, a custom function can be written to bypass a group of points and arm the system, allowing the user to perform this function with one easy command. This can be used to control a particular room, or even a single door allowing customized access. In additions, Custom Functions can be activated with a token or card, or automatically as a scheduled event (SKED) providing further flexibility and ease of use.
Door-activated custom function A custom function activates when user credentials are presented to a B901 or D9210C access control module’s door controller's reader. The custom function behaves as though the user performed a function at the keypad associated with the door controller.
Passcode security For high security applications, GV4 can be configured for several different passcode options.
• Dual Authentication – requires a user to enter their passcode and also use a token or card.
• Two-Man Rule - Requires two people with two unique passcodes to be present at the time of opening.
• Early Ambush - Allows users to verify that the facility is safe by requiring two passcode entries at different keypads within the same area, sending a duress event if the user does not enter the passcode a second time after inspecting the premises.
Easy Exit control The control panel changes from one armed state to another armed state without disarming. For example, if you change the state from Perimeter Arm to Master Arm, the control panel complies and reports the change. Easy Exit Control reduces the number of keystrokes, simplifying system operation.
Programmable passcode-controlled Menu List The system prompts users to enter a passcode prior to viewing the keypad menu. The keypad display shows the user the menu options allowed according to the user’s authority level. Passcode-controlled menus provide users only with the options and information pertinent to them, simplifying system operation.
Flexible control The system provides the flexibility to select added convenience or high security. For example, you can restrict passcode arming and disarming to a keypad's immediate local area, even if the user has access to other areas. This is particularly useful for high security areas, where a user may have access to the area, but would prefer to only disarm the area individually rather than with the rest of the system. Another option is to program the system to disarm all areas the user can access from any keypad.
Invisible walk test A menu item allows the user to test invisible 24-hour points within the scope of the keypad without sending a report to the central station.
System users The system supports up to 1000 users, each can have a passcode, an access token and a wireless keyfob.
User passcodes contain three to six digits. Passcodes can be assigned to one of 14 customized authority levels in each area, and can be restricted to operate only during certain times.
Communication formats The control panel prioritizes and sends reports in Contact ID or Modem IIIa2 communications formats to four route groups. Each group has a programmable primary and backup destination.
The control panel provides flexible communications for most central stations with reporting capabilities such as:
• Individual point numbers
• Opening or closing reports by user and area number
• Remote programming attempts
• Diagnostic reports
IP communication The control panel uses the B426/B420 Connetix Ethernet Communication Module, DX4020 and/or the ITS‑DX4020‑G Cellular Communicator to communicate with the Conettix D6600 and D6100i Communications Receiver/Gateways. Using Conettix IP communication offers a secure path that includes anti-replay/anti-
2 | D9412GV4 Control Panel substitution features and provides enhanced security with encryption. The B420, DX4020 and ITS‑DX4020‑G can all be used for remote programming.
GV4 is the first Security Control panel to support DNS (Domain Name System) for both remote programming and central station communication. DNS provides ease of use, eliminating the need to use static IP addresses as your reporting destination and accommodates a simple solution for central station disaster recovery.
IP Setup is available via the installer keypad menus and the remote programming software, eliminating the need to use complicated internet programming tools such as ARP and Telnet.
Communication paths The control panel accommodates up to four separate destinations for primary, alternate, and backup receivers for automatic test reports.
When resetting alarms or arming or disarming a system, the user is identified by name and number.
Firmware updates Remote firmware updates using the RPS Firmware Update wizard through the IP connection (B426/B420 Connetix Ethernet Communication Module) as well as an on-site flash update key, provides for easy feature enhancements without replacing ROM chips.
*For GV4 version 2.00 firmware update information, refer to the, “GV4 version 2.00 firmware updates” datasheet to learn more about key enhancements, and supported products.
A wide variety of input options Each point:
• Accommodates normally‑open (NO) and normally‑closed (NC) devices with end‑of‑line (EOL) resistor supervision.
• Is programmable for fire, fire supervisory, or intrusion application.
• Can be hard-wired, addressable, or wireless.
Security and Fire detection The control panel provides eight on‑board points, and up to 238 additional off‑board points. You can program individual points to monitor all types of burglar alarms, fire alarms, and supervision devices.
Scheduled events (SKEDS) The internal clock and calendar start individually scheduled events (SKEDS). SKEDS perform functions such as arm or disarm, relay control, or point bypassing. The D9412GV4 Control Panel offers:
• 40 scheduled events with up to 25 different functions
• Eight opening windows and eight closing windows
• Eight user windows
• Day-of-week, date-of-month, or holiday only schedules
• Four holiday schedules of 366 days each (leap year)
Access control The control panel provides custom door strike, point shunt and auto disarming response by area. There are 14 panel-wide access levels with both manual and scheduled control.
Store, view, or print access events such as:
• Access granted
• No entry
• Request to enter
• Request to exit
Wireless interface The B820 SDI2 Inovonics Interface Module connects an Inovonics EN4200 Serial Receiver to the control panel SDI2 bus, allowing this UL Listed wireless system to be programmed locally via the panel keypad, as well as remotely through RPS.
Event log The event log stores up to 1,000 local and transmitted events. The event log includes time, date, event, area, point, user number, and transmission status. View the event log from a keypad or use RPS to remotely retrieve event information. RPS operators can retrieve events periodically using one call, rather than receiving several calls each day. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver.
Fire test When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. The keypad and annunciator show all testing data. An automatic sensor reset feature saves time; you do not need to reset the sensors manually. At the end of test, the keypad shows the number of untested points.
Programming, diagnostics and controls Installers can program locally or remotely through RPS as well as basic keypad programming. A programmable system passcode prevents unauthorized remote programming.
Two data buses GV4 provides 2 data buses which support a wide array of components. The SDI bus supports keypads, access, and communications modules and also allows connection of existing components in a retrofit application. The new SDI2 bus supports input and output devices as well as a new wireless interface module, and an Ethernet communicator. SDI2 allows these devices to be mounted up to 1000 ft (305 m) from the control panel, providing installation convenience and flexibility.
Commercial Fire Alarm support Suitable for Commercial Fire (UL 864, 9th Edition) applications.
Bosch Video Management System integration With Bosch Video Management System (Bosch VMS) and an intrusion system, the VMS operator has a single user interface to monitor and control the intrusion system combined with video surveillance. With Bosch VMS and a control panel, the operator can, for example:
• View videos triggered by intrusion events, including all relevant information such as areas, point, and user show in the display with the event
3 | D9412GV4 Control Panel
• View areas, points, outputs, and doors – with their statuses – on the Bosch VMS map, providing the exact location in the system.
• Turn on (arm) and turn off (disarm) areas.
• Bypass and unbypass points.
• Lock and unlock doors (Bosch VMS 6.0 and higher).
Requirements to integrate Bosch VMS with a control panel:
• A licensed Bosch VMS system using Professional Editions v5.5 or higher or Bosch VMS Enterprise
• Edition v5.5 or higher.
• Expansion license to integrate the intrusion control panel. One license needed per control panel. Order number MBX-XINT-xx for the expansion license added to a Bosch VMS base license. Refer to the Bosch Video Management Software product page on the Bosch website, www.boschsecurity.com.
• Access to Remote Programming Software (RPS).
• Control panel firmware v2.xx
Certifications and approvals
USA:
UL 365 Police Station Connected Burglar Alarm Units and Systems
UL 609 Local Burglar Alarm Units and Systems
UL 636 (NEW) Holdup Alarm Units and Systems
UL 864 Control Units and Accessories for Fire Alarm Systems (Commercial Fire)
UL 985 Household Fire Warning System Units
UL 1023 Household Burglar Alarm System Units
UL 1076 Proprietary Burglar Alarm Units and Systems
UL 1610 Central Station Burglar Alarm Units
ANSI/SIA
CP-01:2010
False Alarm Reduction
FM 3010 Fire Alarm Signaling Systems
CSFM California Office of The State Fire Marshall 7165-1615:0242 Control Unit (Commercial)
FCC Part 15 Class B, Part 68
Region Certification
USA UL 20130918-S1871, UL 864, ANSI/SIA
CP-01-2010, UL 1076, UL 1610, UL
1635, UL 365, UL 609, UL 985, UL
1023, UL 636
CSFM California State Fire Marshal (see our website)
FDNY-
CoA
Region Certification
Canada ULC 20140407-S1871; ULC/ORD-C1076-
M1986, CAN/ULC-S304-06, CAN/ULC-
S303-M91, CAN-ORD-C1023
Brazil ANATEL 1083-12-1855
Installation/configuration notes
Compatible Products
Keypads
D1265 Touch Screen Keypad
D1255 Series Keypads
D1260 Series Keypads
D1256RB Fire Keypad
D1257RB Remote Fire Alarm Annunciator
D720 Series Keypads
D279A Independent Zone Control
Detectors
D278S Four‑wire Addressable Detector Base, 12 VDC
D285/TH Photoelectric Smoke Detector Heads
D298S Addressable Detector Base, 24 VDC
D7050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads
F220‑B6PM/S 12/24 VDC Addressable Detector Bases with POPITs
FCC-380 Carbon Monoxide Detector
MX775i Addressable PIR Detector
MX794i Long Range Multiplex PIR Detector
MX934i Addressable PIR Detector
MX938i Addressable PIR Detector
ZX776Z PIR Detector
ZX794Z Long Range PIR Detector
ZX835 TriTech Microwave/PIR Detector
ZX935Z PIR Detector
ZX938Z PIR Detector
ZX970 PIR/Microwave Detector
Bosch conventional detectors, including Professional Series, Blue Line Gen2, Blue Line, Classic Line, Commercial Line, and Ceiling Mount motion detectors, as well as glass break, seismic, request-to-exit, photoelectric, heat, and smoke detectors.
Enclosures
D8103 Universal Enclosure
4 | D9412GV4 Control Panel
D8108A Attack‑resistant Enclosure
D8109 Fire Enclosure
Magnetic Contacts
Bosch magnetic contacts include recessed, terminal connection, miniature, overhead door, and surface mount.
Modules
Conettix B426 Ethernet Communication Module (NEW)
B208 Octo-input Module
B308 Octo-output Module
B520 Auxiliary Power Supply Module (NEW)
B820 SDI2 Inovonics Interface Module
Conettix B420 Ethernet Communication Module
Conettix ITS‑DX4020-G Cellular Integrated Communicator
Conettix DX4020 Network Interface Module
Conettix DX4010V2 USB/Serial Interface Module
Conettix C900V2 Dialer Capture Module
D113 Battery Lead Supervision Module
D125B Dual Class B Initiating Module
D126 Standby Battery (12V, 7 Ah)
D127 Reversing Relay Module
D129 Class A Initiating Module
D130 Auxiliary Relay Module
D185 Reverse Polarity Signaling Module
D161 Phone Cord
D162 Phone Cord
D192G Notification Appliance Circuit Module
D928 Phone Line Switcher
D5060 MUX Programmer
D8125 POPEX Point Expander
D8128D OctoPOPIT Eight‑point Expander
D8125MUX Point Expander
D8125INV Wireless Interface Module
D8129 Octo‑relay Module
D8130 Door Release Module
D9127 Series POPIT Modules
D9210C Access Control Interface Module
DS7432 Eight‑input Remote Module
DS7457i Series Single‑zone Multiplex Input Modules
DS7460i Two‑input Module
DS7461i Single‑input Multiplex Module
DS7465i Input and Output Module
ICP-SDI-9114 SDI Splitter
Transformers
D1640 Transformer
D1640-CA Transformer
Programming
RPS or RPS‑LITE Remote Programming Software
Readers
ARD‑R10 iCLASS Mullion Reader
ARD‑R40 iCLASS Switchplate Reader
ARD‑RK40‑09 iCLASS PIN Reader
ARD‑VSMART iCLASS Reader
D8223 Prox Pro Reader
D8224 Mullion Reader
D8224‑SP Switch Plate Reader
D8225 Mini Mullion Reader
D8301W Low‑profile Proximity Readers
Wireless
Inovonics wireless
B820 SDI2 Inovonics Interface Module
ENKIT-SDI2 Inovonics Interface and Receiver Kit. Includes B820 and
EN4200
EN1210 Universal Transmitter (Single-input)
EN1210EOL Universal Transmitter with EOL Resistor
EN1210W Door-Window Transmitter with Reed Switch
EN1215EOL Universal Transmitter with Wall Tamper, Reed Switch, and EOL Resistor
EN1223D Water‑resistant Pendant Transmitter (Double‑button)
EN1223S Water‑resistant Pendant Transmitter (Single‑button)
EN1224-ON Multiple-Condition Pendant Transmitter
EN1233D Necklace Pendant Transmitter (Double-button)
EN1233S Necklace Pendant Transmitter (Single-button)
EN1235D Beltclip Pendant Transmitter (Double-button)
EN1235DF Fixed-location Transmitter (Double-button)
EN1235S Beltclip Pendant Transmitter (Single-button)
5 | D9412GV4 Control Panel
EN1235SF Fixed-location Transmitter (Single-button)
EN1247 Glass-break Detector Transmitter
EN1249 Bill Trap Transmitter
EN1242 Smoke Detector Transmitter
EN1260 Wall Mount Motion Detector
EN1261HT High Traffic Motion Detector
EN1262 Motion Detector with Pet Immunity
EM1265 360° Ceiling Mount Motion Detector
EN4200 Serial Receiver
EN5040-T High Power Repeater with Transformer
Parts included
The D9412GV4 includes the following parts:
Quant. Component
1 D9412GV4
1 Faceplate with D9412GV4 Label
1 Literature pack
• Installation Instructions
• Owners Manual
• Release Notes
1 Literature CD containing all product literature
The available kits come with the parts indicated in the following table:
Kits
Components ‑A ‑B ‑C
D9412GV4 1 1 1
D122 Dual Battery Harness 1
D161 Dual Modular Phone Cord 2
D928 Dual Phone Line Switcher 1
D1640 Transformer 1 1
D8103 Enclosure 1
D8108A Attack‑resistant Enclosure 1
D8109 Fire Enclosure 1
D101 Lock and Key Set 1 1
D101F Lock and Key Set 1
Technical specifications
Communications
Telephone Connection:
• One telephone line
• D928 Dual Phone Line Module required for two telephone lines
Environmental Considerations
Relative Humidity: 5% to 93% at +30°C (+86°F), non‑condensing
Temperature (Operating): 0°C to +50°C (+32°F to +122°F)
Number of…
Areas: 32
Card Readers (Doors): 8
Credentials (Tokens): 999
Custom Functions: 16
Events: Up to 1000
Passcode Users: 999, plus 1 service passcode
Parallel Printers: 3
Points: 246 (8 on‑board, up to 238 off‑board)
Programmable Relay Outputs: 131
RF Points: 238
SKEDs: 40
Power Requirements
Current Draw (Maximum): 300 mA
Output (Alarm): 2 A at 12 VDC
Output (Auxiliary, Continuous Power, and Switched Auxiliary combined):
1.4 A at 12 VDC nominal
Voltage (Operating): 12 VDC nominal
Voltage (AC): 16.5 VAC 40 VA plug‑in transformer (D1640)
Ordering information
D9412GV4 Control Panel The D9412GV4 is sold individually or in kits. It supports 246 points.
Order number D9412GV4
D9412GV4-A Attack-resistant Package Contains one PCB, one transformer, and one attack-resistant enclosure.
Order number D9412GV4-A
D9412GV4-B Fire/Burglar Package Contains one PCB, one dual battery harness, two telephone cords, one telephone line switcher, one transformer, and one fire enclosure.
Order number D9412GV4-B
6 | D9412GV4 Control Panel
D9412GV4-C Standard Burglar Package Contains one PCB, one lock and key set, one transformer, and one universal enclosure.
Order number D9412GV4-C
Accessories
B520 Auxiliary Power Supply Module Provides auxiliary power to 12 VDC devices or to SDI2 modules.
Order number B520
B208 Octo-input Module Provides 8 programmable inputs.
Order number B208
B308 Octo-output Module Provides 8 programmable relays.
Order number B308
SDI2 Inovonics Interface and Receiver Kit Kit containing B820 and EN4200 for use on SDI2 bus panels.
Order number ENKIT-SDI2
D122 Dual Battery Harness Harness with circuit breaker. Connects two batteries to a compatible control panel.
Order number D122
D122L Dual Battery Harness with Long Leads Color-coded harness with circuit breaker and leads measuring 89 cm (35 in.). Connects 12 V batteries to compatible control panels.
Order number D122L
D126 Standby Battery (12 V, 7 Ah) A rechargeable sealed lead‑acid power supply used as a secondary power supply or in auxiliary or ancillary functions.
Order number D126
D1218 Battery (12 V, 18 Ah) A 12 V sealed lead‑acid battery for standby and auxiliary power with two bolt‑fastened terminals.
Includes hardware for attaching battery leads or spade connectors Order number D1218
D137 Mounting Bracket Used to mount accessory modules in D8103, D8108A, and D8109 enclosures.
Order number D137
D138 Mounting Bracket, Right Angle Used to mount accessory modules in D8103, D8108A, and D8109 enclosures.
Order number D138
D1640 Transformer System transformer rated at 16.5 VAC, 40 VA.
Order number D1640
D8004 Transformer Enclosure For applications such as fire alarm that might require a transformer enclosure.
Order number D8004
D9002‑5 Mounting Skirt 5 pack of mounting skirts for B8103, D8103, D8108A, and D8109 enclosures. Each skirt can hold up to six standard 3-hole mounting modules.
Order number D9002-5
D101 Lock and Key Set Short-body lock set with one key supplied. Uses the D102 (#1358) replacement key.
Order number D101
D110 Tamper Switch Screw‑on tamper switch that fits all enclosures.
Shipped in packages of two.
Order number D110
ICP‑EZTS Dual Tamper Switch Combination tamper switch with a wire loop for additional tamper outputs.
Order number ICP-EZTS
D8108A Attack Resistant Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. Includes a lock and key set.
Order number D8108A
D8103 Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.).
Order number D8103
D8109 Fire Enclosure Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock and key set.
Order number D8109
BATB-40 Battery Box\Enclosure The BATB-40 Battery Box holds two dry or wet cell batteries. The box can be used with fire alarm systems or intrusion systems.
Order number BATB-40
BATB-80 Battery Box\Enclosure with Shelf The BATB-80 Battery Box holds up to four dry or wet cell batteries. The box can be used with fire alarm systems or with intrusion systems.
Order number BATB-80
D928 Dual Phone Line Switcher Allows the control panel to operate over and supervise two separate phone lines. Only one D162 phone cord is supplied. Two additional D161 or D162 phone cords are required.
Order number D928
7 | D9412GV4 Control Panel
Software Options
RPS Kit (DVD-ROM and USB Security Block) Account management and control panel programming software with USB security key (dongle).
Order number D5500C-USB
8 | D9412GV4 Control Panel
Represented by:
Europe, Middle East, Africa: North America: Asia-Pacific:
Bosch Security Systems B.V.
P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com
Bosch Security Systems, Inc.
130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us
Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia
© Bosch Security Systems 2016 | Data subject to change without notice 2495537803 | en, V19, 21. Jul 2016
The 1006 series is the strongest and most versatile electric strike available. The dual interlocking plunger design and heavy duty stainless steel construction, enables it to exceed every standard developed for electric strikes. With multiple faceplate options, the 1006 will fully accommodate every lock designed to work within an ANSI 4-7/8" strike plate. Tested to exceed 3,000 lbs. of static strength, 350 ft-lbs. of dynamic strength and factory tested to exceed 1,000,000 cycles of operation, the 1006 is in a class of its own.
Specifications
• UL 10C fire-rated, 3 hour single door (fail secure only)
• UL 10C fire-rated, 1-1/2 hour double door (fail secure only)
• CAN4-S104(ULC-S104)
fire door conformant
• ANSI A250.13-2003
windstorm listed
• UL 1034, burglary-resistant listed and suitable for outdoor use
• UL 294 (6th Edition) listed
• ANSI/BHMA A156.31,
Grade 1
• NFPA-252 fire door conformant
• ASTM-E152 fire door conformant
• MEA New York City accepted
• Florida Building Code approved FL#4776
• RoHS compliant
• Environmental
Product Declaration
• Patents: 6,021,038
& 6,595,564
Frame Application
• Metal
• Wood
Electrical (continuous duty)
• .45 Amps at 12 VDC
• .25 Amps at 24 VDC
Shown with KM Option
Series The strongest, most versatile electric strike available
The 1006 Series is also available in a Complete One Box Solution
1006 Models 1006 Universal electric strike Faceplate options ordered separately, see pages 12-16
1006CS Complete electric strike
Includes the SMART Pac II and J, KD, KM, HM, and AD faceplates
1006CLB Complete electric strike Includes the J, K, KD, and KM faceplates
1006CDB Complete electric strike Includes the HM and AD faceplates
RF1016 Integrated Prox
Includes the strike body, Prox reader and door position switch
IC1026 Integrated iCLASS®
Includes the strike body, iCLASS reader and door position switch
8 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions
IN
TE
G
RA
TE
D
PR
O D
U
CT
S
CA
BI
N
ET
L
O
CK
S
AC
CE
SS
O
RI
ES
G
EN
ER
AL
IN
FO
RM
AT
IO
N
FO
LG
ER
A
D A
M H
ES
G
EN
RM
AT
IO
N
AC
CE
SS
O
RI
ES
CA
BI
N
ET
L O
CK
S
IN
TE
G
RA
D
U
CT
S
FO
LG
ER
A D
A M
H
ES
TEG
RATED
PRO
U
CTS
CABIN
ET LO
CKS
ACCESSO
RIES
G
EN
ERAL
IN
FO
RM
ATIO
N
FO
LG
ER AD
A M
H
ES
Diagram shown with N Option
Standard Features
• Stainless steel construction
• Tamper-resistant
• Static strength 3,070 lbs.
(fail secure)
• Dynamic strength 350 ft-lbs.
(fail secure)
• Endurance 1,000,000 cycles
• Fail secure
• Dual-voltage 12 VDC or 24 VDC continuous duty
• Non-handed
• Internally mounted solenoid
• Accommodates up to 1" deadbolt
• Plug-in connector
• Full keeper shims for horizontal adjustment
• Trim enhancer
• Five-year limited warranty
Optional Features LBM » Latchbolt monitor LBSM » Latchbolt strike monitor
• Fail safe
• Interchangeable faceplates Monitor Switches may not work with all faceplate options (see pages 12-16)
Accessories 1000-102 » Rain guard 1006-103 » Full keeper shims 1000-104 » Lip extension trim adapter 1006-105 » Trim enhancer BLK (goof plate) 1006-109 » Trim adapter 1000-110 » Replacement strike plate 1000-130 » KD filler plate
150 » Strike latch guard 154-MTK » Metal template kit 2004M » ElectroLynx® adapter 2005M3 » SMART Pac® III 2006M » Plug-in buzzer
Finishes 630 » Satin stainless steel 605 » Bright brass 606 » Satin brass 612 » Satin bronze 613 » Bronze toned 629 » Bright stainless steel BLK » Black *Complete Pacs are only available in the 630 finish
[104.8] 4-1/8"
[85] 3-3/8"
[123.4] 4-7/8"
[42.7] 1-11/16"
[85] 3-3/8"
[52.4] 2-1/16" [44.5]
1-3/4"
Customer Support 800.626.7590 9© 2016, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
FO
LG
ER AD
A
M
IN
U
CTS
CABIN
ET LO
CKS
ACCESSO
RIES
G
EN
ERAL
IN
FO
RM
ATIO
N
1006 C LB F 630 LBM
Strike Series Complete Lock Type Fail Safe/Secure Finishes Optional Features
Choose the electric strike series number
Specify a “C” to include select faceplates and hardware in the box
“LB” for Latchbolt “S” for
SMART Pac III “DB” for Deadbolt
Specify an “F” for Fail Safe and leave blank for
Fail Secure (standard)
All Complete Pacs are only available in the 630 finish
This item refers to options such as latchbolt monitor or latchbolt strike monitor
Series HES raises the bar again with a Complete line of One Box Solutions
How to Order Part Number Examples
The following is an example describing how to order the new 1006 Complete One Box Solutions.
1006CLB-630-LBM
Is the part number for a 1006 Series electric strike with select option faceplates included in the box, and a stainless steel finish.
If you’re unsure of what lockset you’ll encounter in the field or just want to simplify what you carry, choose an HES Complete electric strike system.
You'll be sure to have a Grade 1 solution to release any cylindrical or mortise lockset that works with an ANSI 4-7/8" strike plate.
Everything is included in the box.
10 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions
IN
TE
G
RA
D
U
CT
S
CA
BI
N
ET
L
O
CK
S
AC
CE
SS
O
RI
ES
G
EN
RM
AT
IO
N
FO
LG
ER
A
D A
M H
ES
G
EN
RM
AT
IO
N
AC
CE
SS
O
RI
ES
CA
BI
N
ET
L O
CK
S
IN
TE
G
RA
D
U
CT
S
FO
LG
ER
A D
A M
U
CTS
CABIN
ET LO
CKS
ACCESSO
RIES
G
EN
ERAL
IN
FO
RM
ATIO
N
FO
LG
ER AD
A M
H
ES
The 1006CS Smart Strike includes a 1006 electric strike body and SMART Pac® III plus faceplates and brackets that can provide the same function as any of the following options:
J Option K Option KD Option KM Option A Option AD Option
AM Option H Option HD Option HM Option HT Option HTD Option
N Option ND Option NM Option T Option TD Option
1006CS
Smart Strike™
The Complete One Box Solution for all cylindrical and mortise locksets, with or without a 1" deadbolt
Compatible Locksets:
Compatible Locksets:
Compatible Locksets:
1006CLB
Complete for Latchbolt Locks The Complete One Box Solution for all cylindrical and mortise locksets The 1006CLB includes the 1006 electric strike body plus faceplates and brackets that provide the same function as any of the following options:
J Option K Option
KD Option KM Option
1006CDB
Complete for Deadbolt Locks The Complete One Box Solution for all locksets with a 1" deadbolt The 1006CDB includes the 1006 electricstrike body plus faceplates and brackets that provide the same function as any of the following options:
A Option AD Option AM Option H Option HD Option
HM Option HT Option HTD Option N Option ND Option
NM Option T Option TD Option
*Complete Pacs are only available in the 630 finish
10 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions Customer Support 800.626.7590 11© 2016, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
FO
LG
ER AD
A
M
IN
U
CTS
CABIN
ET LO
CKS
ACCESSO
RIES
G
EN
ERAL
IN
FO
RM
ATIO
N
1006 Series Faceplate Options
Operation: After releasing the latchbolt, the keeper returns to the locked position
4-7/8" × 1-1/4"
LB Option The Latchbolt Solution: Includes all hardware to accommodate every cylindrical and mortise lock up to a 3/4" latchbolt.
Replaces function of the J, K, KM and KD Options
» ANSI/BHMA Numbers: E09321, E09322, E09323
Operation: This deadbolt solution offers three modes of functionality; night latch, lockout, and normally extended deadbolt. (Functional operation modes described below.)
DB Option The Deadbolt Solution: Includes all hardware to retain, release and recapture all mortise locks, and tubular deadbolts up to a 1" latchbolt Mode 1: Night latch function. The deadbolt is retracted during traffic hours.
The latchbolt is released by the keeper and keeper returns to the locked position.
Mode 2: Lockout function. The electric strike will not release if the deadbolt is extended.
Mode 3: Normally extended deadbolt. Latchbolt and deadbolt are released by a single keeper. The keeper is held open to recapture the latchbolt and deadbolt when the door is closed.
Replaces function of the N, ND, NM, A, AM, AD, T, TD, H, HD, HM, HT, and HTD options
» ANSI/BHMA Numbers: E09391, E09392, E09393, E09331, E09332, E09333
SPECIALTY Operation: After releasing the latchbolt or deadbolt the keeper returns to the locked position
4-7/8" × 1-1/4"
E Option For use with: Corbin Russwin Security Bolt, Weiserbolt and normally extended 1" tubular deadbolts
» ANSI/BHMA Numbers: E09391, E09392, E09393
“For use with” information is offered as a recommendation only. Reference should be made to the lockset manufacturer for proper installation instructions necessary to meet compatibility requirements.
12 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions
IN
TE
G
RA
D
U
CT
S
CA
BI
N
ET
L
O
CK
S
AC
CE
SS
O
RI
ES
G
EN
RM
AT
IO
N
FO
LG
ER
A
D A
M H
ES
FO
LG
ER
A D
A M
IN
TE
G
RA
D
U
CT
S
CA
BI
N
ET
L
O
CK
S
AC
CE
SS
O
RI
ES
G
EN
RM
AT
IO
N
U
CTS
CABIN
ET LO
CKS
ACCESSO
RIES
G
EN
ERAL
IN
FO
RM
ATIO
N
FO
LG
ER AD
A M
H
ES
1006 Series Faceplate Options
SPECIALTY
Operation: The hookbolt is released by a single keeper. The keeper is held open to recapture the latchbolt and hookbolt when the door is closed.
4-7/8" × 1-1/4"
R Option For use with: Adams Rite style hookbolt up to 1" throw
» ANSI/BHMA Numbers: E09391, E09392, E09393, E09332, E09333
SPECIALTY Operation: After releasing the latchbolt, the keeper returns to the locked position
4-7/8" × 1-1/4"
Z Option For use with: Unit and Mono locks
» ANSI/BHMA Numbers: E09321, E09322, E09323
Operation: After releasing the latchbolt, the keeper returns to the locked position
9" × 1-3/8"
J-2 Option For use with: All cylindrical locks up to a 3/4" latchbolt
» ANSI/BHMA Numbers: E09321, E09322, E09323
Operation: After releasing the latchbolt, the keeper returns to the locked position
9" × 1-3/8"
KM-2 Option For use with: Mortise locksets up to a 3/4" latchbolt
» ANSI/BHMA Numbers: E09321, E09322, E09323
Continued on next page »“For use with” information is offered as a recommendation only. Reference should be made to the lockset manufacturer for proper installation instructions necessary to meet compatibility requirements.
12 www.hesinnovations.com ASSA ABLOY, the global leader in door opening solutions Customer Support 800.626.7590 13© 2016, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
G
EN
ERAL
IN
FO
RM
ATIO
N
ACCESSO
RIES
CABIN
ET LO
CKS
IN
U
CTS
FO
LG
ER AD
A M
1006 Series Faceplate Options
Operation: This deadbolt solution offers three modes of functionality; night latch, lockout, and normally extended deadbolt. (Functional operation modes described below.)
9" × 1-3/8"
DB-2 Option The Deadbolt Solution: Includes all hardware to retain, release and recapture all mortise locks, and tubular deadbolts up to a 1" latchbolt Mode 1: Night latch function. The deadbolt is retracted during traffic hours.
The latchbolt is released by the keeper and keeper returns to the locked…