Synopsis.pdf
PDF 179 KB Posted
- Solicitation number
- FA811726R0026
About this file
This is a Pre-award Synopsis for a sole source contract with Kearfott Corporation (CAGE 88818) for repair services of B-2 Attitude Motion Sensor Set (AMSS) and Inertial Measurement Unit (IMU) components. The solicitation number is FA8117-26-R-0026, with a purchase request number of FD2030-25-01609. The solicitation will be issued on or about April 1, 2026, and closes April 30, 2026. The contract is a Firm Fixed Price Requirements type, multi-year arrangement consisting of a base year plus four one-year options. The contractor must possess repair capabilities including appropriate technical data, repair documents, and license agreements to deliver quality serviceable products on schedule. The work involves repair services at various levels (Level 1-3) and No Fault Found (NFF) inspections for three primary NSN/part number combinations: 6605-01-380-3681 (K160A081-30), 6605-01-259-7094 (K160A081-20), and 6610-01-384-7512 (K150A022-52).
The purchase request includes 21 contract line item numbers (CLINs) for the base year and repeating CLINs 1001-1021, 2001-2021, 3001-3021, and 4001-4021 for each option year, with quantities ranging from 1 to 25 units per CLIN. Specific repair services include retrofit work, major/medium/minor repair levels, NFF inspections, and material lay-in items (gyros, HVPS, triad cables, isolators, and accelerometers) for the AMSS unit. Over & Above (O&A) and surge expedite fee CLINs are also included. If unit prices exceed $5,000, IUID requirements apply. The contracting officer is Kristen Carter at kristen.carter@us.af.mil, with the NAICS code 336413. The document specifies that only Kearfott Corporation may submit a bid as the sole source, though all responsible sources may submit capability statements that will be considered by the agency. An Ombudsman is available at (405) 736-3273 to address offeror concerns during the proposal development phase.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CDRL 25-01609.pdf | ||
| Transportation Data for Solicitation.pdf | ||
| GFP_25-01609.pdf | ||
| PWS PR 25-01609.pdf | ||
| Packaging Requirements.pdf | ||
| Exhibit_A.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pre-award Synopsis: Sole Source – Kearfott Corporation (CAGE: 88818)
1. Solicitation will be issued on or about: 01 April 2026 and closes 30 April 2026
2. Solicitation number: FA8117-26-R-0026
3. Purchase Request number: FD2030-25-01609
4. Nomenclature/Noun: Repair of the B-2 Attitude Motion Sensor Set (AMSS) and Inertial Measurement Unit
(IMU)
5. Input NSN: 6605-01-380-3681 / Input PN: K160A081-30
Output NSN: 6605-01-380-3681 / Output PN: K160A081-30 Input NSN: 6605-01-259-7094 / Input PN: K160A081-20 Output NSN: 6605-01-259-7094 / Input PN: K160A081-20 Input NSN: 6610-01-384-7512 / Input PN: K150A022-52 Output NSN: 6610-01-384-7512 / Output PN: K150A022-52
6. Application: See PWS Description: The Contractor is responsible for having the repair capabilities to include appropriate technical data repair documents, and license agreements, required to accomplish this Repair of the B-2 Attitude Motion Sensor Set (AMSS) and Inertial Measurement Unit (IMU) and the below NSNs. The Contractor is responsible for the scheduled delivery of a quality serviceable product. Please read PWS for contractor responsibility.
Purchase Request (CLIN Structure for Contract)
Year NOUN NSN CLIN Qty U/I
Base IMU Repair Level 1 – 3681 6605-01-380-3681 0001 3 EA Base IMU Repair Level 2 - 3681 6605-01-380-3681 0002 1 EA Base IMU Repair Level 3 - 3681 6605-01-380-3681 0003 1 EA
Base IMU No Fault Found (NFF) - 3681 6605-01-380-3681 0004 1 EA Base IMU Repair Level 1 – 7094 6605-01-259-7094 0005 1 EA Base IMU Repair Level 2 - 7094 6605-01-259-7094 0006 1 EA Base IMU Repair Level 3 - 7094 6605-01-259-7094 0007 1 EA Base IMU No Fault Found (NFF) - 7094 6605-01-259-7094 0008 1 EA Base AMSS Retrofit – 7512 6610-01-384-7512 0009 1 EA Base AMSS Major Repair Level 1 – 7512 6610-01-384-7512 0010 10 EA Base AMSS Medium Repair Level 2 – 7512 6610-01-384-7512 0011 1 EA Base AMSS Minor Repair Level 3 – 7512 6610-01-384-7512 0012 1 EA Base AMSS No Fault Found (NFF) - 7512 6610-01-384-7512 0013 1 EA Base AMSS Material Lay-In (Gyros) - 7512 6610-01-384-7512 0014 25 EA Base AMSS Material Lay-In (HVPS) – 7512 6610-01-384-7512 0015 5 EA Base AMSS Material Lay-In (Triad Cables) - 7512 6610-01-384-7512 0016 1 EA Base AMSS Material Lay-In (Isolators) – 7512 6610-01-384-7512 0017 15 EA Base AMSS Material Lay-In (Accelerometer) - 7512 6610-01-384-7512 0018 1 EA Base Over & Above (O&A) 0019 1 TBN Base Over & Above (O&A) – Surge Expedite Fee 0020 1 TBN Base Data 0021 1 NSP OYI IMU Repair Level 1 – 3681 6605-01-380-3681 1001 3 EA
OYI IMU Repair Level 2 - 3681 6605-01-380-3681 1002 1 EA
OYI IMU Repair Level 3 - 3681 6605-01-380-3681 1003 1 EA
OYI IMU No Fault Found (NFF) - 3681 6605-01-380-3681 1004 1 EA
OYI IMU Repair Level 1 – 7094 6605-01-259-7094 1005 1 EA
OYI IMU Repair Level 2 - 7094 6605-01-259-7094 1006 1 EA
OYI IMU Repair Level 3 - 7094 6605-01-259-7094 1007 1 EA
OYI IMU No Fault Found (NFF) - 7094 6605-01-259-7094 1008 1 EA
OYI AMSS Retrofit – 7512 6610-01-384-7512 1009 1 EA OYI AMSS Major Repair Level 1 – 7512 6610-01-384-7512 1010 10 EA OYI AMSS Medium Repair Level 2 – 7512 6610-01-384-7512 1011 1 EA OYI AMSS Minor Repair Level 3 – 7512 6610-01-384-7512 1012 1 EA OYI AMSS No Fault Found (NFF) - 7512 6610-01-384-7512 1013 1 EA OYI AMSS Material Lay-In (Gyros) - 7512 6610-01-384-7512 1014 25 EA OYI AMSS Material Lay-In (HVPS) – 7512 6610-01-384-7512 1015 5 EA OYI AMSS Material Lay-In (Triad Cables) - 7512 6610-01-384-7512 1016 1 EA OYI AMSS Material Lay-In (Isolators) – 7512 6610-01-384-7512 1017 15 EA OYI AMSS Material Lay-In (Accelerometer) - 7512 6610-01-384-7512 1018 1 EA OYI Over & Above (O&A) 1019 1 TBN OYI Over & Above (O&A) – Surge Expedite Fee 1020 1 TBN OYI Data 1021 1 NSP OYII IMU Repair Level 1 – 3681 6605-01-380-3681 2001 3 EA OYII IMU Repair Level 2 - 3681 6605-01-380-3681 2002 1 EA OYII IMU Repair Level 3 - 3681 6605-01-380-3681 2003 1 EA OYII IMU No Fault Found (NFF) - 3681 6605-01-380-3681 2004 1 EA OYII IMU Repair Level 1 – 7094 6605-01-259-7094 2005 1 EA OYII IMU Repair Level 2 - 7094 6605-01-259-7094 2006 1 EA OYII IMU Repair Level 3 - 7094 6605-01-259-7094 2007 1 EA OYII IMU No Fault Found (NFF) - 7094 6605-01-259-7094 2008 1 EA OYII AMSS Retrofit – 7512 6610-01-384-7512 2009 1 EA OYII AMSS Major Repair Level 1 – 7512 6610-01-384-7512 2010 10 EA OYII AMSS Medium Repair Level 2 – 7512 6610-01-384-7512 2011 1 EA OYII AMSS Minor Repair Level 3 – 7512 6610-01-384-7512 2012 1 EA OYII AMSS No Fault Found (NFF) - 7512 6610-01-384-7512 2013 1 EA OYII AMSS Material Lay-In (Gyros) - 7512 6610-01-384-7512 2014 25 EA OYII AMSS Material Lay-In (HVPS) – 7512 6610-01-384-7512 2015 5 EA OYII AMSS Material Lay-In (Triad Cables) - 7512 6610-01-384-7512 2016 1 EA OYII AMSS Material Lay-In (Isolators) – 7512 6610-01-384-7512 2017 15 EA OYII AMSS Material Lay-In (Accelerometer) - 7512 6610-01-384-7512 2018 1 EA OYII Over & Above (O&A) 2019 1 TBN OYII Over & Above (O&A) – Surge Expedite Fee 2020 1 TBN OYII Data 2021 1 NSP
OYIII IMU Repair Level 1 – 3681 6605-01-380-3681 3001 3 EA OYIII IMU Repair Level 2 - 3681 6605-01-380-3681 3002 1 EA OYIII IMU Repair Level 3 - 3681 6605-01-380-3681 3003 1 EA OYIII IMU No Fault Found (NFF) - 3681 6605-01-380-3681 3004 1 EA OYIII IMU Repair Level 1 – 7094 6605-01-259-7094 3005 1 EA OYIII IMU Repair Level 2 - 7094 6605-01-259-7094 3006 1 EA OYIII IMU Repair Level 3 - 7094 6605-01-259-7094 3007 1 EA OYIII IMU No Fault Found (NFF) - 7094 6605-01-259-7094 3008 1 EA OYIII AMSS Retrofit – 7512 6610-01-384-7512 3009 1 EA OYIII AMSS Major Repair Level 1 – 7512 6610-01-384-7512 3010 10 EA OYIII AMSS Medium Repair Level 2 – 7512 6610-01-384-7512 3011 1 EA OYIII AMSS Minor Repair Level 3 – 7512 6610-01-384-7512 3012 1 EA OYIII AMSS No Fault Found (NFF) - 7512 6610-01-384-7512 3013 1 EA OYIII AMSS Material Lay-In (Gyros) - 7512 6610-01-384-7512 3014 25 EA OYIII AMSS Material Lay-In (HVPS) – 7512 6610-01-384-7512 3015 5 EA OYIII AMSS Material Lay-In (Triad Cables) - 7512 6610-01-384-7512 3016 1 EA OYIII AMSS Material Lay-In (Isolators) – 7512 6610-01-384-7512 3017 15 EA OYIII AMSS Material Lay-In (Accelerometer) - 7512 6610-01-384-7512 3018 1 EA OYIII Over & Above (O&A) 3019 1 TBN OYIII Over & Above (O&A) – Surge Expedite Fee 3020 1 TBN OYIII Data 3021 1 NSP OYIV IMU Repair Level 1 – 3681 6605-01-380-3681 4001 3 EA OYIV IMU Repair Level 2 - 3681 6605-01-380-3681 4002 1 EA OYIV IMU Repair Level 3 - 3681 6605-01-380-3681 4003 1 EA OYIV IMU No Fault Found (NFF) - 3681 6605-01-380-3681 4004 1 EA OYIV IMU Repair Level 1 – 7094 6605-01-259-7094 4005 1 EA OYIV IMU Repair Level 2 - 7094 6605-01-259-7094 4006 1 EA OYIV IMU Repair Level 3 - 7094 6605-01-259-7094 4007 1 EA OYIV IMU No Fault Found (NFF) - 7094 6605-01-259-7094 4008 1 EA OYIV AMSS Retrofit – 7512 6610-01-384-7512 4009 1 EA OYIV AMSS Major Repair Level 1 – 7512 6610-01-384-7512 4010 10 EA OYIV AMSS Medium Repair Level 2 – 7512 6610-01-384-7512 4011 1 EA OYIV AMSS Minor Repair Level 3 – 7512 6610-01-384-7512 4012 1 EA OYIV AMSS No Fault Found (NFF) - 7512 6610-01-384-7512 4013 1 EA OYIV AMSS Material Lay-In (Gyros) - 7512 6610-01-384-7512 4014 25 EA OYIV AMSS Material Lay-In (HVPS) – 7512 6610-01-384-7512 4015 5 EA OYIV AMSS Material Lay-In (Triad Cables) - 7512 6610-01-384-7512 4016 1 EA OYIV AMSS Material Lay-In (Isolators) – 7512 6610-01-384-7512 4017 15 EA OYIV AMSS Material Lay-In (Accelerometer) - 7512 6610-01-384-7512 4018 1 EA OYIV Over & Above (O&A) 4019 1 TBN OYIV Over & Above (O&A) – Surge Expedite Fee 4020 1 TBN OYIV Data 4021 1 NSP
7. Contract Type and Length: Firm Fixed Price Requirements type contract. Multi-year contract (Base plus four 1-Year Option) for the Repair of the B-2 Attitude Motion Sensor Set (AMSS) and Inertial Measurement Unit
(IMU).
8. IUID Note to Contractor: If unit price exceeds $5,000, then IUID requirements will apply.
9. Written procedures will be used for this solicitation. No telephone requests. Only electronic requests received directly from the requestor are acceptable. Only the responsible sole source solicited may submit a bid, proposal, or quotation, which shall be considered. Note: An Ombudsman has been appointed to hear concerns from offerors or potential offerors during the proposal development phase of this acquisition. The purpose of the Ombudsman is not to diminish the authority of the program director or contracting officer, but to communicate contractor concerns, issues, disagreements, and recommendations to the appropriate government personnel.
When requested, the Ombudsman will maintain strict confidentiality as to the source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call Ombudsman at (405) 736-3273. DO NOT CALL THIS NUMBER FOR
SOLICATION REQUESTS.
10. All responsible sources may submit a capability statement, proposal, or quotation, which shall be considered by the agency.
11. POC: Kristen Carter at kristen.carter@us.af.mil, NAICS: 336413
File details come from the government source that posted it. Updated .